OCS-XZ-C Series User s Guide. OCS-XZ Series Electronic Crane Scale. User s Guide - 1 -



Similar documents
OCSM Series. High Resolution Digital Crane Scale. User Guide

OCS-S High Resolution Digital Crane Scale

ACS-3S/NEW SU ELECTRONIC SINGLE/DUAL DISPLAY WEIGHING/COUNTING SCALE USER MANUAL

High precision counting scale. Operation Manual. l RCZ-A Series

Ron 3025 Crane Scale with 1"/25mm Display

CASTON. Crane Scale. OWNER S MANUAL (BT Ver.) 9007-CT3-BT

HIGH PRECISION WEIGHING SCALE. Operation Manual. l RCZ-B Series

ELECTRONIC COUNTING SCALE. Operation Manual. l JCS- A SERIES

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Instruction Manual Crane Scales PCE-HS Series

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

CONTIENTS. 1. SPECIFICATIONS (mm) CAUTIONS INSTALLATION INSTRUCTION

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

GSM Alarm System User Manual

BW-500 BED WEIGHER USER MANUAL

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

PowerGem Pro Uninterruptible Power Supply

INSTRUCTION. The smallest GPS watch locator in the country

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

My Weigh Ultraship Series User Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

ANALYTICAL BALANCE OPERATION MANUAL. (FA/JA Series)

MicroLite II Release Notes

4-Channel Thermometer / Datalogger

Thermistor Thermometer MODEL NO

Professional Thermohygrometer

OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

Operating Manual Electronic Wheelchair Scale with cable display M50610

MSI3460. User Guide. Measurement Systems International. Challenger 3 Crane Scales

XP Series Balances Operation Manual

INDUSTRIAL INSTRUMENTATION

Model 349KLX Remote Display Digital Scale User Instructions

BODY FAT & HYDRATION % MONITOR SCALE

User s Manual Before using the inverter, you need to read and save the safety instructions.

T Sentry 4 Multi-Point Digital Alarm Instruction Manual

Product Information Sheet UH28CS-12kV Hi Pot Tester

Part 1 Product introduction 2. Part 2 Features 3. Part 3 Safety notes 4. Part 4 Quick user s guide 5. Part 5 Operation notes 7

Point of view HDMI Smart TV dongle Mini RF Keyboard

MANUAL TR-110 TR-110

TECHANGLE November 30, 2005 TECHNICAL PAGE

Digital indicator 3011

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

OSMO Release Notes Major Updates. Notes

12 Volt 30 Amp Digital Solar Charge Controller

GPS Vehicle and personal location tracker. User manual

Mobile Data Power Model: MDP-25

Phoenix Body Fat Scale Manual

EX 2000/EX 2000 C/ GD 2000/GDP

Keep it Simple Timing

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Model SRMD Setra Remote Monitoring Display

e s p i o n s.com. V680 GPS Watch User s Manual

Sensing element Polymer humidity capacitor Operating range humidity 0-100%RH; temperature -40~80Celsius Accuracy

Operating instructions Platform/floor scales

DC Electronic Loads 8500 series

Digital Air Pressure Gauge Users Manual

Instruction Manual FL

User s Manual AURORA 1.2K/2.2K

GSM HOME SECURITY SYSTEM

INSTALLATION & SERVICE MANUAL. Display Panel

Virtual Measurements & Control. Flip/Flop Filler

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

SATEX SA Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg DA Zeewolde HOLLAND

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Thank you for choosing Huwei E589 4G Mobile WiFi

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Temp. & humidity Transmitter Instructions

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

User's Guide. Pinless Moisture Meter. Model MO257

SMS Alarm. User Manual

DAB+ / FM Tuner Model: TU-201

3NNet KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19

ELECTRIC FENCE ENERGISER

CS Digital Microscope User Manual

MVS - Mini Video Speaker

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

CPS-3 Pallet Jack Scale

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

VIVA 4G LTE Mini Router. Quick Start Guide

Ground Resistance Clamp On Tester

Microwave Meter. Instruction Manual

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Dyeing Programmer DP - 01

2» 10» 18» 26» PD »

DC-8706K Auto Dial Alarm System

DAB1001. Wireless Digital Radio Interface. Installation & User Guide

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

Operating Instructions. Coating Thickness Gauges MINITEST 1001 MINITEST 2000

Installation and Operation Back-UPS 1250, 1300, 1500

Relative Humidity Calibration Kit

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Deluxe Electronic Body Fat Analyzer Body Weight Scale

Connecting your Victron product to a computer with VE Configure

ADVANCED USER S GUIDE

LCD Monitor User Manual

TS1200 Intelligent Lead Free Soldering Station. Operation Manual

Transcription:

OCS-XZ Series Electronic Crane Scale User s Guide - 1 -

Table of Contents 1. Brief Introduction 2. Features & Specifications 3. Functions of Key Pad & Indicators 4. Basic Operations Power ON Initial on Zeroing Manual Addition Display of Total Weight Set Parameters Initial on Zero Range Setup Clear Weighing Power OFF 5. Battery Charging 6. scale care 7. Calibration 8. Dimensioned Drawing of Scale 9. Instruction of Remote Control - 2 -

1. Overview OCS-XZ series crane scale is a high-tech scale. The digital crane scale employs both the advanced hardware and sophisticated software. It uses AT-89 series single-chip micro-processor and highly precision A/D converter. In addition, the crane scale is equipped with specially designed compensating circuitry for rocking loads. With its quick stabilization and strong interference-rejection, it can be widely used in weighing applications in commerce, industrial and mining industries, and warehousing wharf, etc. 2. Features & Specifications Accuracy Class Initial on Zero Range Time to Stable Static Reading Maximum Safe Load Display Screen Operating Temperature Operating Humidity LOB Indicator Auto-OFF Recharging Protective Circuitry Cast Aluminum Housing National Standard Accuracy Class III Selectable 0% 5% 10% 20% 50% 100% F.S 10 seconds 150% F.S. Super bright 1.2 5-digit LED display -10 C ~ +40 C 85%RH When the power is low, the indicator will be on The scale will shut off automatically once the power is severely low. To prolong the performing life of the battery Rust protection, antistatic & light weight Model Weigh Capacity (Kg) Division Resolutions OCS-XZ-06 600 0.2 3000 OCS-XZ-1 1000 0.5 2000 OCS-XZ-2 2000 1 2000 OCS-XZ-3 3000 1 3000 OCS-XZ-5 5000 2 2500 OCS-XZ-10 10000 5 2000 3. Functions of Key Pad & Indicators - 3 -

Presented below is the scale panel: As presented on the panel, [ADD/INPUT], [DIV.SHI/<], [HOLD/^], [ZERO] are operating keys, of whose functions are in the following: a) [ADD/INPUT] Use this key to add the load weight. It is only usable when the scale is in manual mode of operation. b) [DIV.SHI/<] Use this key to select the resolution. Except the resolution listed in the table above, we can select the required resolution smaller than the listed ones. If the set value is the minimum resolution of the scale, the [DIV.SHI] indicator will be ON. c) [HOLD/^] Press this key to keep the current displaying weight and the [HOLD] indicator will be on. Press the key again to turn off temporarily holding function. d) [ZERO] Press this key to zero the current displaying value. On the panel, AUTO, LOB, DIV.SHI, HOLD and STAB are indicators e) Auto This indicator is on when the scale is in Auto-Add mode. f) LOB - This indicator is ON when the voltage is less than 6V. g) DIV.SHI - When it is ON, it indicates that the current division value is at or less than the minimum resolution of the scale. h) HOLD - When it is ON, it indicates that the scale is in temporarily holding mode. i) STAB When it is ON, it indicates that the acquired weight data is stable. 4. Basic Operations 4.1 Power On Turn on the power switch at the back of scale to the ON position. The scale will display the version number and then the maximum weight capacity individually for one second. Then the nixie light will display 99999, 88888. 00000 in turn. Then scale will undergo selfcheck of reset sequence and indicators with LED indicators on and off alternatively and finally come into weighing mode. 4.2 Initial on zeroing After power on, the scale enters into weighing mode and then displays 0 kg. If it is not 0 kg, it s normally caused by overloading the permitted value of the initial on zero range. In this - 4 -

case, please switch off the scale and re-start it and choose the desired parameter. (Please see initial on zero Range below.) 4.3 Manual Addition When the displaying value is over zero, with weight on the scale, pressing [ADD/INPUT] key, the current weighing value will be added to the total weight if with valid parameter. (Please see 4.5 Set Parameters.) The scale will show bxxxx for about one second. Here, b means the total number of loads and XXXX indicates the total number of adding. Note: No matter manual add or atuo-add, please zero the displaying value before another manual adding. Here, the zeroing range includes 20 division value of the capacity. When the number of adding reaches 9999, it will display FULL which indicates full memory. In this case, please clear the memory according to 4.7 Clear in the following. 4.4 Display of Total Weight When the displaying value is within the zeroing range, press key [ADD/INPUT] to see the total number of adding and the total weight of loads. It will firstly display the total number of loads. For example, the scale shows b0327 indicating 327 loads weighed so far. Press [ADD/INPUT] again, it will display the four left-hand number of the added value. For instance, H 108 indicates the left-hand number of the total weight is 108. Press [ADD/INPUT] for the third times, it will show the four right-hand number of the total weight. For your reference, L 2896 indicates the right-hand number of the total weight is 2896. Accordingly, the total weight of the loads is 1082896 kg. 4.5 Set Parameters Press key [Zero] during self-checking and it will display PAXYZ. Here, XYZ is decimal number which can be revised by pressing key [HOLD/^] or [DIV.SHI/<] (Please see 7. Calibration ). The valid range of the three numbers is between 0 and 255. If inputting a number from 256 to 999, the data recognized by the scale is equal to the remainder after division by 256. XYZ can be represented by 8 binary digits described as follows: D0: Selection between Manual Adding and Auto-Adding, digit 1 indicates Auto-Adding. D1: Non-Beeper and Beeper when the weighing value becoming stable, digit 1 means you selecting beeper. D2: Selecting Close or Activate Zero point drift, digit 1 is to activate the Zero point drift. D3.D4: To switch off the scale. When D4=0, the scale will keep displaying no matter what D3 is. When D4=1, D3=1the scale will keep working for 30 minutes with stable weighing value displayed and then power-off automatically. When D3=0, the displaying window will go into sleeping mode with stable weighing value for 30 minutes. It will be activated when the displaying value is unstable or press the key [DIV.SHI/<]. D5: Digit 1 means that pressing [ADD/INPUT] with stable displaying value is valid when manual adding selected. Digit 0 means [ADD/INPUT] is valid with unstable displaying value. D6-D7: Any digit is valid but 0 is recommended. D0-D7 mentioned above respectively represents the 8 binary digits, with valid value 0 or 1. XYZ= 128*D7+64*D6+32*D5+16*D4+8*D3+4*D2+2*D1+D0. For example, XYZ=62 indicates: D7=0, D6=0,D5=1,D4=1,D3=1,D2=1,D1=1,D0-0, this is the default values set during manufacturing in the factory. - 5 -

When displaying PAXYZ, if press [ADD/INPUT], the selected data will be saved (The data will still be saved even the scale is powered off.) The scale will come into weighing mode after self-checking. Press [ZERO] to enter into the state of setting zeroing range. 4.6 Initial on zero range Setup During the process of self-check at Power ON, press [ZERO] to show PAXYZ. Press [ZERO] again to show O UUU. Here, O indicates the function of initial on zero range. If UUU equals to 20, it means the present zeroing range is 20% which is default values set during manufacturing in the factory. Use key [HOLD/^] to change the initial on zero range. After selection, press [ADD/INPUT] to save the selected parameters of PAXYZ and the zeroing range and confirm the operation. The scale will go into weighing mode after self-checking. If you press [ZERO], it will go to clearing mode. 4.7 Clear During the self-checking at Power on, press [ZERO] and it will display PAXYZ. Press [ZERO] twice after PAXYZ, it will display CLEAr. Press [ADD/INPUT] to save the parameters and the zeroing range. Meanwhile, the total number of loads and the total weight will be cleared during this operation. The scale will change into weighing mode after self-check. If you press [ZERO] instead of [ADD/INPUT], the set parameters in the previous operation will not be kept and used. The scale then will go into mode of limiting weight/ calibration. 4.8 Weighing During the weighing process, the weight is ready to be recorded when the stable weight result is shown and the STAB indicator is on. If there is tare involved, such as rope or container, weigh them first. Press [ZERO] to apply tare. The display should now be 0.0kg, the net weight. With no change to the tare, the loads weighed afterwards will be their net weights until the change of tare value or the scale is turned off. 4.9 Power Off After the weighing operation, turn off the scale by using the power switch on the back of the scale. 5. Battery Charging 5.1 It adopts maintenance-free rechargeable battery (6V/4Ah) and smart charger (DC6V/1Ah). 5.2 Then LOB indicator will be on if there is low power. The battery needs to be charged now. The scale, however, can continue to operate for about 5hours without charging. 5.3 After the LOB indicator is ON for several hours without charging or there is no more power in the battery, the scale will be powered off automatically. It will take about 5 hours to fully charge the battery. 5.4 After battery charging, if there is no display, it indicates that either there is difficulty in battery charging or a damaged battery. Please contact supplier for repair or replacement. 5.5 To prolong the battery life, we suggest you charge the battery no less than once per week. If the scale needs not to be charged for long time, you should charge it no less than once per week. To avoid any damage to the battery, please charge it correctly. Additionally, we suggest you switch off the scale to short the charging time. - 6 -

6. Scale Care 6.1 Do not overload the scale to prevent the damage to the force transducer inside the scale. It will alarm you with buzzer and display OVErl if overloaded. 6.2 If display Err01 after power on the scale,indicaters that it will influence the accuracy or the important parameters lost. 6.3 Please check the scale frequently to insure the safe use. The basic checking list is: 6.3.1 Whether the screw has come loose 6.3.2 Whether the hook or shackle or any other component is cracked or distorted 6.3.3 If the mechanical components showing sign of metal fatigue or defects 6.3.4 Whether the pin is off or the components are lost. If there is any sign of the mentioned condition, please send the scale or components back to the manufacturer for repair or exchange before using the scale again. 6.4 Avoid any impact to the display panel. 6.5 6.5 Do not use the scale under wet or heavily polluted conditions. 7. Calibration Steps Operation Display Remarks 1 During self-check, press 1 st step of calibration. [ZERO]. After PAXYZ, 00000 Password is required. press [ZERO] three times. 2 Press [HOLD/^] to select the desired number, press ****** ****** is the password [DIV.SHI/<] to shift digit 3 After entering password, There should be no load SPEN press [ADD/INPUT] on the scale 4 Press [ADD/INPUT] 4112 4112 is the encode at 5 press [ADD/INPUT] 00000 6 7 Press [HOLD/^] to change to the desired number for the standard weight, press [DIV.SHI/<] to shift digits After the standard weight is loaded, press [ADD/INPUT] 03000 34683 8 Press [ADD/INPUT] 3000 zeroing loading Wait until the codes become stabilized and press [ADD/INPUT] 03000 is the standard weight of 3000kg to be loaded. 34683 is the encode number of standard weight - 3000kg. Calibration is completed. The scale is in weighing mode. The current weight load is displayed. Note: 1.Please make sure to wait until the encode is stabilized then press [ADD/INPUT]. Or it will lead incorrect weighing results. 2. Do not calibrate the scale without standard weight. 8. Dimensioned Drawing of Scale - 7 -

Mode Maximum Capacity (ton) d A D F OCS-XZ-06 0.6 Φ21 34 Φ76 517 OCS-XZ-1 1 Φ21 34 Φ76 517 OCS-XZ-2 2 Φ21 34 Φ76 522 OCS-XZ-3 3 Φ23 40 Φ76 543 OCS-XZ-5 5 Φ26 48 Φ80 692 OCS-XZ-10 10 Φ36 52 Φ90 710 9. Instruction of Remote Controller Remote Control & Usage - 8 -

i. SW: to perform division change as [DIV.SHI/<] key on the display panel. ii. Press Hold: to Hold the settled values. iii. Press Zero: to zero out the current displayed value as [ZERO] on the display panel. iv. Press BL: to perform ADD/INPUT function as [ADD/INPUT] on the display panel. The products are subject to change without notice. - 9 -