EIB/KNX IP Interface with Power over Ethernet (PoE)



Similar documents
KNX IP INTERFACE IN00A02IPI. Operating and installation manual

KNX IP Interface. Operating and installation manual

IN00A01IPI. Hardware specification KNX IP INTERFACE IN00A02IPISH IN00A02IPISH Specifica N. Progetto N. Titolo del progetto

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

Application program usage. Functional description. Note. Note. instabus EIB Application Program Description. August CO IP-Interface

Application software. IP/KNX Interface Electrical / Mechanical characteristics : see product information. Order number. TP device RF devices

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

ABB i-bus KNX IP Router IPR/S 2.1

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

HWg-STE HWg-STE PoE MANUAL

instabus EIB Manual February 2004 Table of Contents

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Ha-VIS FTS 3000 Introduction and features

Application Program Description

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

PCS0100en Persy Control Services B.V. Netherlands

IntesisBox KNX Modbus TCP master

SHEET. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

UPS Network Interface. Quick InstallationGuide

Computer Networks I Laboratory Exercise 1

Product and functional description

P Quick Start Guide. VoIP Analog Telephone Adaptor DEFAULT LOGIN. IP Address Password Version /2007 Edition 1

connecdim Gateway G1 Ethernet TCP/IP to DALI

Portable BACnet /IP to MS/TP Router

Quick Installation Guide. Overview. GULFSIP ATA-G1S Quick Installation Guide

HARTING econ 3000 Introduction and features

SOHO 6 Wireless Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0

KNX Interface. User Manual PM00A00IRI

KNX IP only A New Class of KNX Devices. WEINZIERL ENGINEERING GmbH. Dr.-Ing. Th. Weinzierl D Tyrlaching

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

ebridge1spr - EoC Receiver ebridge4spt - 4 Port PoE/PoE+ EoC Transceiver Switch

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

MicroLink dlan ADSL Modem Router

HARTING mcon 3000 Introduction and features

SBG3300-N Series. Wireless N VDSL2 Combo WAN Small Business Security Gateway DEFAULT LOGIN DETAILS. Firmware Version 1.20 Edition 3, 3/2015

GUIDE. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

HARTING econ 4000 Introduction and features

HARTING mcon 1000 Introduction and features

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG

User Manual. EtherUSB

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

DSL Installation Guide

Multi-Homing Dual WAN Firewall Router

Operating Instructions. Sophos Access Points

ADSL Modem Installation Guide. Model # 36R515 Part # Rev. D Revision Date 12/2000. ADSL Modem Installation Guide

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Firewall VPN Router. Quick Installation Guide M73-APO09-380

IntesisBox Modbus Server SAMSUNG Air Conditioners

ORION TELECOM NETWORKS INC. T1

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

TX OPEN RS232/485 module

C24-CAMANL Video Server/Encoder

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Quick-Start Guide 007-SE Gigaset. Residential Wireless Gateway SE567/SE568. Gigaset Communications GmbH is a trademark licensee of Siemens AG

Windows 7. Basic Network Connection Setup

IntesisBox KNX Mitsubishi Heavy Industries AC

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

Setting Up the Cisco IP Phone

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

NeoGate TA Series Installation Guide

Check Your Package Contents. CD-ROM containing Manual and Warranty

Information about IP Proprietary Telephones KX-TDA50/KX-TDA100 KX-TDA200/KX-TDA600. Hybrid IP-PBX. Model No.

GPS NTP Time Server for Intranet Networks DIN RAIL Version

HP-1000E v2. User s Manual. Powerline Ethernet Adapter. HP1000E v2 User s Manual

SNMP Web Management. User s Manual For SNMP Web Card/Box

R70 Ethernet to CAN interface Manual (1.4 EN)

(IR) Bullet LPR/ANPR Network Camera

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

DRO-210i LOAD BALANCING ROUTER. Review Package Contents

WS 2000 Wireless Switch. System Reference

Powerline 1200 User Manual

User guide for NANOSTATION 2

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

DOCSIS/EuroDOCSIS 3.0 Cable Modems

SHEET. BASautomation. BAS Router BACnet Multi-Network Router. BAS Router

IFS SP-PoE Splitter User Manual

Digi Connect WAN Application Guide Using the Digi Connect WAN and Digi Connect VPN with a Wireless Router/Access Point

Job Aid Pre-Installation Information S8500 Media Server

Quick Start Guide. Cisco Small Business. 200 Series 8-Port Smart Switches

KNX Panasonic Air Conditioners

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Welcome. Unleash Your Phone

CANOPY TM AP C A N O P Y C A N O P Y. Getting Started with Motorola REV 12/18/01. Specifications

3.5 EXTERNAL NETWORK HDD. User s Manual

OUTDOOR IR NETWORK CAMERA Series

Product and Application Description

C9 HD Video Conference Terminal

What is VLAN Routing?

How To Use A Power Supply On A Powerline 2.2 (Ai)

Configuring a customer owned router to function as a switch with Ultra TV

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Transcription:

EIB/KNX IP Interface with Power over Ethernet (PoE) IP Interface between LAN and EIB/KNX bus (Quelle: EIBMARKT GmbH, Reference No.: N000401) Page 1

Application area The KNXnet/IP-Interface is used to connect a PC to the KNX/EIB network. The connection is made through LAN (IP). The IP address can be obtained by a DHCP server or by manual configuration (ETS) respectively. This device works according to the KNXnet/IP specification using the core, the device management und the tunnelling part. Page 2

Note: The Power over Ethernet supply is standardized acc. to Standard PoE (IEEE) and integrated via RJ45.As an alternative, power supply can be provided by means of screw connecting terminals at the upper side using a separate power supply unit (12-24V DC) or transformer (12-24V AC). Parallel power must be avoided! Page 3

Technical data Electrical safety Protection (EN 60529): IP 20 Safety extra low voltage SELV DC 24 V EMC requirements Complies with EN 61000-6-2, EN 61000-6-3 and EN 50090-2-2 Environmental requirements Ambient temp. operating: - 5... + 45 C Ambient temp. Non-op.: - 25... + 70 C Rel. humidity (non-condensing): 5 % 93 % Certification EIB/KNX CE norm Complies with the EMC regulations (residential and functional buildings) and low voltage directive Physical specifications Housing: Plastic Rail mounted device Width: 36 mm Weight: approx. 100 g Fire load: approx. 1000 kj Operating controls Learning key for EIB/KNX Indicators Learning-LED (red) Signal-LED (green) for EIB/KNX Signal-LED (green) for LAN Ethernet 10BaseT (10Mbit/s) Supported internet protocols ARP, ICMP, IGMP, UDP/IP and DHCP Power supply External supply 12-24V Alternative: Power-over-Ethernet Power consumption: < 800 mw Connectors EIB/KNX connection terminal LAN RJ-45 socket Screw connector for power supply Page 4

Operating and installation manual ETS database The following parameters can be set on the ETS: General: Device name: The KNX IP Interface can be assigned a name of your choice. The device name should be descriptive (e.g. Line TF). It is used to search for and recognize a device. IP address assignment: Automatic (DHCP): The IP address is automatically assigned on the DHCP, i.e. additional settings are not required. To be able to use this function, there must be a DHCP server in the LAN (many DSL routers have an integrated DHCP server). Manual: In this case, the IP address, the subnet and the gateway IP address must be entered manually. Page 5

IP configuration: IP address: This is the IP address of the EIB/KNX IP Interface. Page 6

IP subnet: Enter the subnet mask here. The device uses the values entered in this mask to determine whether there is a communications partner in the local network. If there is no partner in the local network, the device will not send the telegrams directly to the partner but to the gateway that routes the telegram. IP gateway address: Enter the IP address of the gateway here. Note: If the KNX IP Interface will only used in the local LAN, the entry of 0.0.0.0 can remain unchanged. Example of assigning IP addresses: A PC is to be used to access the EIB/KNX IP Interface. IP address of the PC: 192.168.1.30 Subnet of the PC: 255.255.255.0 The EIB/KNX IP Interface is located in the same local LAN, i.e. it uses the same subnet. The subnet constrains the IP addresses that can be assigned. In this example, the IP address of the IP interface must be 192.168.1.xx, where xx can be a number from 1 to 254 (with the exception of 30, which is already in use). It must be ensured that no numbers are assigned twice. IP address of the IP interface: 192.168.1.31 Subnet of the IP interface: 255.255.255.0 ETS Connection Manager If the IP configuration of the EIB/KNX IP Interface is valid, the interface can be used as an interface to KNX/EIB. To use this function, select the Communication tab under Extras -> Options in the ETS (version 3.0c and higher): Click Configure interfaces to open the ETS Connection Manager. Page 7

Create a new connection by selecting EIBnet/IP under Type. The ETS automatically begins searching for all KNXnet/IP devices. All devices found are displayed. Select the required device. To be able to access KNX/EIB, the EIB/KNX IP Interface requires an additional physical address. This second physical address is only used for bus access and must be set up separately: Select the Communication tab under Extras -> Options in the ETS. The communications interface is the connection that is currently configured. Click on Settings to open the following window: Enter a physical address of your choice. A dummy device may have to be added to the ETS project to reserve this address. Page 8

Installation and connection The EIB/KNX IP Interface is designed for installation in a rack with a depth of 2 units. It contains the following display and control elements: 1: Connector for external power supply (12 V to 24 V AC/DC) 2: Connector for KNX/EIB with a bus terminal 3: Learn key 4: Learn LED (red) 5: LED (green): - Lights up to indicate bus voltage on KNX/EIB - Flashes to indicate telegram traffic 6: LED (green): - Lights up to indicate an Ethernet connection - Flashes to indicate telegram traffic 7: RJ 45 socket for connecting an Ethernet patch cable An external power supply only needs to be connected if the switch in use does not support Power-over-Ethernet. EIBMARKT GmbH Friedensstraße 54 08523 Plauen Germany 2010 EIBMARKT GmbH www.eibmarkt.com Alle Rechte vorbehalten. All rights reserved. Page 9