Technical Information Software Version 7.1.3.12 Box Camera DF4620HD-DN Module Camera MDF4220HD Dome Cameras DDF4220HDV Picodome DDF4320HD-DN DDF4520HDV-DN DDF4620HDV-DN English Version 1.0 / 2016-03-08
1 Abstract This document contains information on new features and changes that are introduced with the latest software version. In addition, it includes descriptions for a correct update process. Finally, this document provides an overview of the tested and supported features of the different software versions. 2 Validity This document applies to the following devices: Box Camera DF4620HD-DN Module Camera MDF4220HD Dome Cameras DDF4220HDV Picodome DDF4320HD-DN DDF4520HDV-DN DDF4620HDV-DN The descriptions in this document are based on the software version 7.1.3.12. 3 Compatibility The software version 7.1.3.12 is compatible with the following hard- and software: Dallmeier Live Video ActiveX control as of version 1.3.1.16 SMAVIA Viewing Client as of version 1.0.2.16 SMAVIA Viewer as of version 1.0.2.16 SMAVIA Appliances as of version 8.x.3 Recording systems gen. 4 (DMS, DLS, VNS, VNB) as of version 7.1.4 Recording systems gen. 4 (DMX) as of version 7.3.5 ActiveX is a trademark or registered trademark of Microsoft Corporation headquartered in Redmond, Washington, USA. 4 General Notes Note that the software update to version 7.1.3.12 is free of charge. new features and changes are only generally described in this document. the Dallmeier support hotline is always available for further questions. some features may be subject to costs. due to dynamic development and constant improvement, some functions may not be provided in all software versions. www.dallmeier.com 2
5 Update Procedure The software update to version 7.1.3.12 can be downloaded from the corresponding product pages on www.dallmeier.com. The update is performed over the network using the PService3 software which is also available for download on www.dallmeier.com. You only need to download and install PService3 once. Updating your IP device is only possible via TCP/IP. Therefore, your IP device must be available in your local area network (LAN) in order for data to be transferred successfully. Performing Update 1. Download the required zip files. 2. Unzip the downloaded zip files into a local directory on your hard disk (using WinZip or a similar program). 3. Run PService3. 4. Follow the update instructions in the corresponding PService3 documentation. WinZip is a trademark or registered trademark of WinZip International LLC headquartered in Storrs Mansfield, Connecticut, USA. NOTICE: Only files with the ending *.sh can be opened. Leave the Update code field blank. 5. Once all required information has been entered, click OK. The update process is then started. NOTICE: Do not disconnect the device from the power supply during the update process (up to 5 minutes). The device will automatically reboot after the update process is completed. www.dallmeier.com 3
6 New Features and Changes Dallmeier Live Video ActiveX control version 1.3.1.16 Description With this update, the version 1.3.1.16 of the Dallmeier Live Video ActiveX control is available for downloading directly from the device ( Service > Download ). Always install the latest version of the Dallmeier Live Video ActiveX control on your client PC after the connection to the device is established in order to obtain the optimal system performance. Availability X Update X Reinstallation Hardware Necessary X Not necessary Requirements ActiveX is a trademark or registered trademark of Microsoft Corporation headquartered in Redmond, Washington, USA. Download URL for Dallmeier Live Video ActiveX control Description With this update, the URL for downloading the Dallmeier Live Video ActiveX control via Internet has been changed on the device. Once a connection to the WebConfig user interface of the device is established using the Microsoft Internet Explorer and the client PC has an active Internet connection, the currently published Dallmeier Live Video ActiveX control can be automatically downloaded from the Internet (if it is not already installed on the client PC). If no Internet connection is available on the client PC, the Dallmeier Live Video ActiveX control that is provided with this update can be directly downloaded from the device ( Service > Download ) and installed on the client PC. Always install the latest version of the Dallmeier Live Video ActiveX control on your client PC after the connection to the device is established in order to obtain the optimal system performance. Availability X Update X Reinstallation Hardware Necessary X Not necessary Requirements Microsoft, ActiveX and Internet Explorer are trademarks or registered trademarks of Microsoft Corporation headquartered in Redmond, Washington, USA. Dropbear SSH2 server Description With this update, the integrated Dropbear SSH2 server has been updated from version 0.52 to version 2015.68 in order to fix potential security vulnerabilities (reported and tested on Security Lists ) when accessing the device via SSH (Secure Shell). Availability X Update X Reinstallation Hardware Necessary X Not necessary Requirements www.dallmeier.com 4
Watchdog for shutdown Description With the current version, the internal monitoring function (Watchdog) has been optimized to ensure that all running processes are properly terminated before a system shutdown or a system reboot. In previous versions, a system update, system restart or system shutdown may have caused data inconsistencies under certain circumstances. This issue has been resolved with the current version. Availability X Update X Reinstallation Hardware Necessary X Not necessary Requirements www.dallmeier.com 5
7 Functional Range The described general functional range of the software may possibly not be relevant for all devices. Always observe the corresponding specifications of the respective device. Version Function 7.1.0.8 7.1.0.11 7.1.1.8 7.1.2.7 7.1.3.6 7.1.3.7 7.1.3.8 7.1.3.12 Privacy zones in any order O X X X X X X X Casino Preset O O X X X X X X ESMTP support O O X X X X X X Watchdog for boot procedure O O X X X X X X SNMP extensions Firmware update directly from WebConfig user interface Optimization of slider rendering in Microsoft Internet Explorer 10 & 11 Microsoft and Internet Explorer are trademarks or registered trademarks of Microsoft Corporation headquartered in Redmond, Washington, USA. Dallmeier Live Video ActiveX control version 1.3.1.5 ActiveX is a trademark or registered trademark of Microsoft Corporation headquartered in Redmond, Washington, USA. Super low light mode Manual setting of shutter speed and signal amplification (gain) Performance optimization when drawing privacy zones Selective system shutdown or system restart EdgeStorage for Emergency Recording with SmartBackfill Display of Date/Time in the encoded video Support of ONVIF Profile S Optimization of the analog video output (CVBS) Turkish language Maximum Transmission Unit (MTU) Optimization MJPEG transmission over HTTP RTSP Multicast Streaming Audio IN for 4620 series O O O O X X X X Default (exposure time = 1/50 sec. + WDR = off) O O O O X X X X Display individual numbers and letters as camera name O O O O O X X X Permanent winter time (Russia) O O O O O O X X www.dallmeier.com 6
Version Function 7.1.0.8 7.1.0.11 7.1.1.8 7.1.2.7 7.1.3.6 7.1.3.7 7.1.3.8 7.1.3.12 Dallmeier Live Video ActiveX control version 1.3.1.16 added ActiveX is a trademark or registered trademark of Microsoft Corporation headquartered in Redmond, Washington, USA. Download URL for Dallmeier Live Video ActiveX control changed ActiveX is a trademark or registered trademark of Microsoft Corporation headquartered in Redmond, Washington, USA. Dropbear SSH2 server updated from version 0.52 to version 2015.68 Watchdog for shutdown procedures optimized O O O O O O O X O O O O O O O X O O O O O O O X O O O O O O O X X = Function is available in version O = Function is not available in version Furthermore, note that the functional range is subject to a dynamic development and determined by the requirements of the market and the product policy. Some functions are designated for implementation in a later version or may not be implemented at all. www.dallmeier.com 7
All trademarks identified by are registered trademarks of Dallmeier electronic. Specifications subject to change without notice. Errors and misprints excepted. 2016 Dallmeier electronic Dallmeier electronic GmbH & Co.KG Cranachweg 1 93051 Regensburg Germany Phone: +49 (0) 941 87 00-0 Fax: +49 (0) 941 87 00-180 www.dallmeier.com