PI734B - Technical Data Sheet



Similar documents
PI734D - Technical Data Sheet

UCI274C - Technical Data Sheet

UCI274H - Technical Data Sheet

PM734F - Technical Data Sheet Winding 28

BCI184E - Technical Data Sheet

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

3790 en / d. Alternators LSA Pole. Electrical and mechanical data

STAMFORD Product Guide

IGSA POWER GENERATION SYSTEMS

CUKUROVA GENERATOR SYSTEMS

SYNCHRONOUS MACHINES

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Effective: September 10, 2006 Vermont Attachment 1 to Rule Public Service Board Page 1 of 6

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

AC-Synchronous Generator

Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Automatic Voltage Regulator User s Manual

Verification of Short Circuit Test Results of Salient Poles Synchronous Generator

Basics of Electricity

R438 A.V.R. Installation and maintenance R 438. This manual is to be given to. the end user T10. Armature 6- Field X2 Z1 X1 Z2 E+ E- 0V

R448 & R448 V50 A.V.R.

Physical Address: City: State: Zip Code:

Synchronous motor. Type. Non-excited motors

CUMMINS SERIE 6B. Definiciónes. Potencia Prime. Potencia Stand by. Estos valores son aplicables para el suministro de energía eléctrica continua

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Rules for Classification and Construction Additional Rules and Guidelines

DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION

DIESEL GENERATOR SETS

Application Information

FAULT FINDING MANUAL. For Stamford AC Generators

WIND TURBINE TECHNOLOGY

Generators TEM. for small hydroelectric power stations. Electric Machines

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

C Standard AC Motors

Torque motors. direct drive technology

Paralleling Power Sources Which Share a Common Neutral

Diesel Generator Set Model DFHC 60 Hz

Keywords: synchronous generator, synchronous motor, automatic voltage regulator, V- curves, synchronizing power, hunting, excitation system

FIT TIER 2 Application

Diesel Generator Set Model DFMB 60 Hz

FAULT FINDING MANUAL For Self Excited and Separately Excited Generators

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

Installation, Service & Maintenance Manual for AC generators with prefix MV734

Lab 8: DC generators: shunt, series, and compounded.

High Efficiency Motor Protection. Industry White Paper

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

Spark-ignited generator set

CUKUROVA GENERATOR SYSTEMS

Installation, Service & Maintenance Manual

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

Installation, Service & Maintenance Manual

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP

SX460. Generator Automatic Voltage Regulator Operation Manual

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

FREQUENCY CONTROLLED AC MOTOR DRIVE

Unit 33 Three-Phase Motors

SUNON SPECIFICATION FOR APPROVAL

Annex-A TECHNICAL SPECIFICATION

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Diesel Engine Driven Generators Page 1 of 6

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Harmonics in your electrical system

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Installation, Service & Maintenance Manual for HC 4, 5 & 6 AC Generators

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

Induction Motor Theory

Motor Fundamentals. DC Motor

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR

Type SA-1 Generator Differential Relay

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Diesel Generating Set

CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR

Principles of Adjustable Frequency Drives

How To Control A Power Command Powerplant

Welcome to Linear Controls Quarterly Training

Mounting Instructions. Torque Transducer. A en

Diesel Generator Set Model DGDK 60 Hz

Excitation.

Offshore Platform Powered With New Electrical Motor Drive System

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

How the efficiency of induction motor is measured?

Atlas Copco Generators

Understanding the Alternator

Motors and Generators

Mathematical Modeling and Dynamic Simulation of a Class of Drive Systems with Permanent Magnet Synchronous Motors

Transcription:

PI734B - Technical Data Sheet

PI734B SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC60034, CSA C22.2-100, AS1359. Other standards and certifications can be considered on request. DESCRIPTION The STAMFORD PI range of synchronous ac generators are brushless with a rotating field. They are separately excited by the STAMFORD Permanent Magnet Generator (PMG). This is a shaft mounted, high frequency, pilot exciter which provides a constant supply of clean power via the Automatic Voltage Regulator (AVR) to the main exciter. The main exciter output is fed to the main rotor, through a full wave bridge rectifier, protected by surge suppression. VOLTAGE REGULATORS The PI range generators, complete with a PMG, are available with one of two AVRs. Each AVR has soft start voltage build up and built in protection against sustained over-excitation, which will de-excite the generator after a minimum of 8 seconds. Underspeed protection (UFRO) is also provided on both AVRs. The UFRO will reduce the generator output voltage proportional to the speed of the generator below a presettable level. The MX341 AVR is two phase sensed with a voltage regulation of ± 1 %. (see the note on regulation). The MX321 AVR is 3 phase rms sensed with a voltage regulation of 0.5% rms (see the note on regulation). The UFRO circuit has adjustable slope and dwell for controlled recovery from step loads. An over voltage protection circuit will shutdown the output device of the AVR, it can also trip an optional excitation circuit breaker if required. As an option, short circuit current limiting is available with the addition of current transformers. Both the MX341 and the MX321 need a generator mounted current transformer to provide quadrature droop characteristics for load sharing during parallel operation. Provision is also made for the connection of the STAMFORD power factor controller, for embedded applications, and a remote voltage trimmer. WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th ) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low levels of voltage waveform distortion. TERMINALS & TERMINAL BOX Standard generators feature a main stator with 6 ends brought out to the terminals, which are mounted on the frame at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access. SHAFT & KEYS All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. INSULATION/IMPREGNATION The insulation system is class 'H', and meets the requirements of UL1446. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. QUALITY ASSURANCE Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001. NOTE ON REGULATION The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 61000-6-2:2001. At no time will the steady-state voltage regulation exceed 2%. Note: Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing is typical of the product range. 2

CONTROL SYSTEM PI734B WINDING 312 SEPARATELY EXCITED BY P.M.G. A.V.R. MX341 MX321 VOLTAGE REGULATION ± 1% ± 0.5 % With 4% ENGINE GOVERNING SUSTAINED SHORT CIRCUIT REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7) INSULATION SYSTEM PROTECTION RATED POWER FACTOR STATOR WINDING WINDING PITCH WINDING LEADS MAIN STATOR RESISTANCE MAIN ROTOR RESISTANCE EXCITER STATOR RESISTANCE EXCITER ROTOR RESISTANCE R.F.I. SUPPRESSION CLASS H IP23 0.8 DOUBLE LAYER LAP TWO THIRDS 6 0.0016 Ohms PER PHASE AT 22 C STAR CONNECTED 1.67 Ohms at 22 C 17.5 Ohms at 22 C 0.048 Ohms PER PHASE AT 22 C BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% MAXIMUM OVERSPEED BEARING DRIVE END BEARING NON-DRIVE END 2250 Rev/Min BALL. 6228 C3 BALL. 6319 C3 1 BEARING 2 BEARING WEIGHT COMP. GENERATOR WEIGHT WOUND STATOR WEIGHT WOUND ROTOR 2760 kg 1306 kg 1139 kg 2710 kg 1306 kg 1077 kg WR² INERTIA SHIPPING WEIGHTS in a crate PACKING CRATE SIZE 32.7498 kgm 2 31.7489 kgm 2 2833kg 2779kg 194 x 105 x 154(cm) 194 x 105 x 154(cm) 50 60 TELEPHONE INTERFERENCE COOLING AIR VOLTAGE STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277 kva BASE RATING FOR REACTANCE VALUES 1360 1400 1400 1375 1525 1625 1655 1690 Xd DIR. AXIS SYNCHRONOUS 3.50 3.26 3.02 2.64 4.25 4.04 3.77 3.53 X'd DIR. AXIS TRANSIENT 0.21 0.20 0.18 0.16 0.26 0.25 0.23 0.22 X''d DIR. AXIS SUBTRANSIENT 0.16 0.15 0.14 0.12 0.19 0.18 0.17 0.16 Xq QUAD. AXIS REACTANCE 2.26 2.10 1.95 1.70 2.74 2.61 2.43 2.28 X''q QUAD. AXIS SUBTRANSIENT 0.32 0.29 0.27 0.24 0.38 0.37 0.34 0.32 XL LEAKAGE REACTANCE 0.04 0.04 0.03 0.03 0.05 0.05 0.04 0.04 X2 NEGATIVE SEQUENCE 0.22 0.21 0.19 0.17 0.27 0.26 0.24 0.23 X0 ZERO SEQUENCE 0.03 0.03 0.02 0.02 0.03 0.03 0.03 0.03 REACTANCES ARE SATURATED T'd TRANSIENT TIME CONST. 0.13s T''d SUB-TRANSTIME CONST. 0.01s T'do O.C. FIELD TIME CONST. 2.14s Ta ARMATURE TIME CONST. 0.02s SHORT CIRCUIT RATIO THF<2% 2.69 m³/sec 5700 cfm 3.45 m³/sec 7300 cfm VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED 3 1/Xd TIF<50

50 PI734B Winding 312 THREE PHASE EFFICIENCY CURVES 4

PI734B Winding 312 THREE PHASE EFFICIENCY CURVES 60 5

30 50 PI734B Winding 312 Locked Rotor Motor Starting Curve 346V 380V 400V 415V 440V 25 PER CENT TRANSIENT VOLTAGE DIP. 20 15 10 5 0 0 500 1000 1500 2000 2500 3000 3500 LOCKED ROTOR kva 30 60 380V 416V 440V 460V 480V 25 PER CENT TRANSIENT VOLTAGE DIP. 20 15 10 5 0 0 500 1000 1500 2000 2500 3000 3500 LOCKED ROTOR kva 6

50 PI734B Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated Speed Based on star (wye) connection. 100000 SYMMETRICAL ASYMMETRICAL CURRENT (Amps) 10000 1000 0.001 0.01 0.1 1 10 TIME (secs) Sustained Short Circuit = 4,400 Amps 60 100000 SYMMETRICAL ASYMMETRICAL CURRENT (Amps) 10000 1000 0.001 0.01 0.1 TIME (secs) 1 10 Sustained Short Circuit = 4,650 Amps Note 1 The following multiplication factors should be used to adjust the values from curve between time 0.001 seconds and the minimum current Note 2 The following multiplication factor should be used to convert the values calculated in accordance with NOTE 1 to those applicable to the various types of short circuit : point in respect of nominal operating voltage : 50 60 3-phase 2-phase L-L 1-phase L-N Voltage Factor Voltage Factor Instantaneous x 1.00 x 0.87 x 1.30 380v x 1.00 416v x 1.00 Minimum x 1.00 x 1.80 x 3.20 400v x 1.05 440v x 1.06 Sustained x 1.00 x 1.50 x 2.50 415v x 1.09 460v x 1.10 Max. sustained duration 10 sec. 5 sec. 2 sec. 440v x 1.16 480v x 1.15 All other times are unchanged The sustained current value is constant irrespective Note 3 of voltage level Curves are drawn for Star (Wye) connected machines. 7

PI734B Winding 312 / 0.8 Power Factor RATINGS Class - Temp Rise Cont. F - 105/40 C Cont. H - 125/40 C Standby - 150/40 C Standby - 163/27 C 50 Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440 kva 1265 1305 1305 1280 1360 1400 1400 1375 1415 1460 1460 1430 1455 1500 1500 1470 kw 1012 1044 1044 1024 1088 1120 1120 1100 1132 1168 1168 1144 1164 1200 1200 1176 Efficiency (%) 95.4 95.5 95.6 95.7 95.2 95.3 95.4 95.6 95.1 95.2 95.3 95.5 95.0 95.1 95.2 95.4 kw Input 1061 1093 1092 1070 1143 1175 1174 1151 1190 1227 1226 1198 1225 1262 1261 1233 60 Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480 kva 1415 1510 1540 1575 1525 1625 1655 1690 1590 1690 1725 1760 1630 1740 1775 1810 kw 1132 1208 1232 1260 1220 1300 1324 1352 1272 1352 1380 1408 1304 1392 1420 1448 Efficiency (%) 95.4 95.5 95.6 95.6 95.3 95.3 95.4 95.5 95.2 95.2 95.3 95.4 95.1 95.2 95.3 95.3 kw Input 1187 1265 1289 1318 1280 1364 1388 1416 1336 1420 1448 1476 1371 1462 1490 1519 DIMENSIONS 2004 Newage International Limited. Reprinted with permission of N.I. only. Printed in England. Barnack Road Stamford Lincolnshire PE9 2NB Tel: 00 44 (0)1780 484000 Fax: 00 44 (0)1780 484100 Website: www.newage-avkseg.com TD_PI734B.GB_05.04_02_GB