Flow Injection Analysis

Similar documents
LACHAT METHOD NUMBER D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately g CN/L g CN/L. 09e

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

HS 1003 Part 2 HS 1003 Heavy Metals Test

Chapter 1 The Atomic Nature of Matter

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Cyanide Analysis Guide

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

Building Electrochemical Cells

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

B) atomic number C) both the solid and the liquid phase D) Au C) Sn, Si, C A) metal C) O, S, Se C) In D) tin D) methane D) bismuth B) Group 2 metal

CNSolution TM 9310 On-line Cyanide Analyzer. Product Release Synopsis. I Product Description/Function. 1 3 Cyanide Recycle

Lab #11: Determination of a Chemical Equilibrium Constant

EXPERIMENT 8: Activity Series (Single Displacement Reactions)

KINETIC DETERMINATION OF SELENIUM BY VISIBLE SPECTROSCOPY (VERSION 1.8)

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Periodic Table, Valency and Formula

100% ionic compounds do not exist but predominantly ionic compounds are formed when metals combine with non-metals.

FMA-80 Fluorescence Mercury Analyzer

Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method)

12. REDOX EQUILIBRIA

X-RAY FLUORESCENCE SPECTROSCOPY IN PLASTICS RECYCLING

One problem often faced in qualitative analysis is to test for one ion in a

Chemistry Unit 2 Acids and Bases

This experiment involves the separation and identification of ions using

SODIUM CARBOXYMETHYL CELLULOSE

AMD Analysis & Technology AG

Optimize Your Process Operations by Improving Process Monitoring

Chapter 16: Tests for ions and gases

Continuous-Flow Analyzers

Chem 115 POGIL Worksheet - Week 4 Moles & Stoichiometry

Determination of Metals in a 3% Sodium Chloride (NaCl) Matrix by Axially-Viewed ICP-OES

Chem 1A Exam 2 Review Problems

Find a pair of elements in the periodic table with atomic numbers less than 20 that are an exception to the original periodic law.

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

Molecular Spectroscopy

Chem101: General Chemistry Lecture 9 Acids and Bases

Complexometric Titrations

Ion Selective Electrodes

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

OLIVÉR BÁNHIDI 1. Introduction

Properties of Acids and Bases

Nomenclature of Ionic Compounds

Name Electrochemical Cells Practice Exam Date:

KEY for Unit 1 Your Chemical Toolbox: Scientific Concepts, Fundamentals of Typical Calculations, the Atom and Much More

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

APPLICATION OF ICP-MS TECHNOLOGY FOR TRACE METALS ANALYSIS

Experiment 5. Chemical Reactions A + X AX AX A + X A + BX AX + B AZ + BX AX + BZ

DMA-80 Direct Mercury Analyzer

Notes Chapter 9 Limiting Reagent Sample Problems Page 1

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

Ch 20 Electrochemistry: the study of the relationships between electricity and chemical reactions.

Chem 115 POGIL Worksheet - Week 4 Moles & Stoichiometry Answers

3 - Atomic Absorption Spectroscopy

Experiment 8 - Double Displacement Reactions

Focus XC. Ultimate Fully Automated Peptide Synthesizer with Sonication and Heating Options

Chapter 1: Moles and equations. Learning outcomes. you should be able to:

Santa Monica College Chemistry 11

EXPERIMENT 7 Electrochemical Cells: A Discovery Exercise 1. Introduction. Discussion

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Redox and Electrochemistry

The Sievers 900 Series TOC Analyzers

Qualitative Analysis

MODERN ATOMIC THEORY AND THE PERIODIC TABLE

The Empirical Formula of a Compound

Corrosion of Copper in Water

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

This value, called the ionic product of water, Kw, is related to the equilibrium constant of water

CLASS TEST GRADE 11. PHYSICAL SCIENCES: CHEMISTRY Test 6: Chemical change

RECOMMENDED SPECIFICATION. Cogent Environmental OVA-5000 Heavy Metal Analyzer. to Monitor Total Dissolved Arsenic. for

Balancing Chemical Equations

IB Chemistry 1 Mole. One atom of C-12 has a mass of 12 amu. One mole of C-12 has a mass of 12 g. Grams we can use more easily.

neutrons are present?

Volumetric Analysis. Lecture 5 Experiment 9 in Beran page 109 Prelab = Page 115

2.02 DETERMINATION OF THE FORMULA OF A COMPLEX BY SPECTROPHOTOMETRY

ROSE ANTHOCYANINS AS ACID BASE INDICATORS

A Visual Method for the Detection of Arsenic 0 to 500 µg/l By Dan Kroll R&D Chemist. Hach Co., Loveland Colorado

EXPERIMENT 4 The Periodic Table - Atoms and Elements

Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC

Fundamentals of Mass Flow Control

4.1 Stoichiometry. 3 Basic Steps. 4. Stoichiometry. Stoichiometry. Butane Lighter 2C 4 H O 2 10H 2 O + 8CO 2

Chapter 17. How are acids different from bases? Acid Physical properties. Base. Explaining the difference in properties of acids and bases

Name period AP chemistry Unit 2 worksheet Practice problems

Experiment 1 Chemical Reactions and Net Ionic Equations

Lab 2 Biochemistry. Learning Objectives. Introduction. Lipid Structure and Role in Food. The lab has the following learning objectives.

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

23 The Thermal Conductivity Detector

Balancing Chemical Equations

Unit 2: Quantities in Chemistry

MILESTONE H E L P I N G C H E M I S T S

Solutions and Dilutions

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Enzymes: Amylase Activity in Starch-degrading Soil Isolates

Dissolved and precipitated oxalate

Part One: Mass and Moles of Substance. Molecular Mass = sum of the Atomic Masses in a molecule

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

Transcription:

Flow Injection Analysis Almost all reagent based assays can be downscaled and automated by Flow Injection Analysis. FIA was first described in a patent filed in Denmark by Ruzicka and Hansen in 1974. Since then the technique has grown into a discipline covered by 22 monographs and over 20,000 research papers. The scope of the method grew from a tool for automation of serial assays to a method for enhancing the performance of spectroscopic and electrochemical instruments. The conventional FIA methodology, the Flow Injection (FI) is based on continuous flow, while its most recent variant, the Programmable Flow Injection uses different flow rates during individual steps of the assay protocol with aim to optimize the analytical readout. The second generation of FI techniques, the Sequential Injection (SI) also utilizes flow programming to optimize the assay protocol, but in contrast to FI it uses discontinuous flow generated by a syringe pump, and operates at microliter scale. The Conventional Flow Injection Method The conventional FI technique is based on injection of sample solution into a carrier solution that is continuously moving at a constant flow rate. The carrier stream transports the analyzed species through the reactor and into the detector. The assay protocol comprises the following steps: A) Sample injection is designed to meter an exact volume of analyte solution into a flowing stream of reagent. B) As the sample zone (red) moves downstream, the dispersion process mixes sample with reagent forming a reaction product (yellow). The extent of mixing and the length of reaction time is controlled by the flow rate, by channel volume, and by channel geometry. C) The reaction mixture flows through the detector yielding an analytical readout. Since all standards and samples to be analyzed are individually processed in exactly the same way, the calibration curve is valid for unknown samples to be assayed 1 www.flowinjection.com

The peak height recorded by the detector is proportional to the analyte concentration. Single Line System: Chloride Assay Flow diagram for colorimetric assay of chloride. Colorimetric Assay of Chloride. Each sample injected four times. In this, the simplest configuration, a chloride sample is injected, by means of a two position valve, into a continuously flowing carrier stream of reagent. As the injected zone moves downstream, the sample solution disperses within the reagent, forming a reaction product. A flow through detector placed downstream records absorbance, yielding readout within 15 seconds after sample (S1) injection. Three Line Systems: Nitrate Assay FI manifold for automated assay of nitrate with integrated cadmium column using sulfanilamide reagent.. The calibration record of 0, 2, 5 and 8 ppm nitrate is followed by a routine run of nitrate assay extracted from soil samples. 2 www.flowinjection.com

Hydride Generation for Atomic Spectroscopies (AA and ICP) This method is routinely used for trace analysis of As, Bi, Ge, Hg, Pb, Se, Sn and Te. In addition, assay of volatile compounds of Ag, Co, Cu, Ni, and Zn has been reported. Separation of the trace metals from complex matrices, analyte enrichment, fast reaction speed, and ease of automation were first demonstrated by Astrom (1982) in his pioneering work on the FI-based hydride AA assay of bismuth. By combining an acidified sample stream with a strong reducing agent (sodium borohydride), hydrogen and metal hydride are rapidly released, and the gaseous phase is separated with the aid of purging gas (air or argon) and swept into AA or ICP for detection. The Programmable Flow Injection Method Advances in hardware and computer control, recently allowed a further refinement of FI technique, by applying the principle of flow programming, originally designed for Sequential Injection. Each step of an assay protocol, sample injection, mixing, incubation, product monitoring and instrument washout is best performed at an different flow rate. Thus instrument washout is most efficiently performed at a maximum flow rate, while for a slow chemical reaction a low flow rate is preferable, and data collection is favored by moderate flow rates. Conventional assay protocols, based on constant flow rate are therefore necessarily compromised, as they operate at averaged flow rates, or use excessively long reaction coils to gain reaction time for slower chemical reactions. In contrast, flow programming saves reagents, by applying very low 3 www.flowinjection.com

flow rates for sample incubation and fast flow rates of short duration for washout of the system. The unprecedented advantage of flow programming is the increased sensitivity and detection limit of most reagent based assays, achieved by adjusting the flow rate and incubation time from the computer keyboard, without need for system reconfiguration. High Sensitivity Assay of o- Phosphate This assay is based on a fast reaction of o-phosphate with ammonium molybdate forming molybdenum yellow, which is in turn reduced at a much slower rate to molybdenum blue, which is monitored at 880nm. The flow rate for this assay is programmed to 100% for startup and sample injection, to 2% for incubation time, to 50% for monitoring and 100% for system washout. During the selected dwell period the combined flow rate of 2% was 600 microiters per minute. By adjusting the duration of the dwell period the sensitivity and the detection limit can be selected to cover the range of 0.5 ppb P to 1000 ppb P (10 cm light path flow cell, flow rate at 100% 4mL/min per channel). For details see Programmable Flow Injection for o-phosphate assay Ammonia Assay by Gas Diffusion This assay is based on conversion of ammonium ion into ammonia gas that diffuses through a gas permeable membrane into a receptor stream of an acid/base indicator. The indicator, bromothymol blue is converted from acid (yellow) form into a basic ( blue) form that is monitored at 620nm. Since acid /base reaction in both donor and acceptor 4 www.flowinjection.com

stream are very fast, the rate limiting step is ammonia diffusion across the membrane. Therefore the flow rate of the donor stream is decreased when the sample zone is in contact with the diffusion membrane during the dwell time. The flow rate for this assay is programmed to 100% for startup and sample injection, and mixing, to 2% for incubation time, 50% for monitoring and 100% for system washout. During the selected dwell period the combined flow rate was only 600 microiters per minute. By adjusting the duration of the dwell flow period from 0 seconds (continuous flow) to 120 seconds the sensitivity and the detection limit improved 10 times. The method covers the range 0.1 to 1 ppm N. 10 cm light path flow cell, 2 cm long diffusion path, flow rate at 100% 4mL/min per channel). For details see Gas Diffusion Methods and Protocols (Ammonia) Flow Injection or Air Segmented (Auto Analyzer) Technique? Both techniques automate a wide range of wet chemical assays, by replacing manual solution handling with flow based methodology. While Air Segmentation (originally marketed as AutoAnalyzer ) has served well for over 60 years, it has become a legacy technique, and is being replaced by Flow Injection in both routine as well as research laboratories. This, is because FIA techniques offer: Higher sampling frequency: 2 samples/minute - or even up to 6 samples/minute. Short residence time: readout within less than 30 seconds after sample injection. Low sample consumption: typically 50 to 200 microliters Low reagent consumption: typically 1ml per assay Small instrument footprint: about 1/5 of a typical Auto Analyzer bench space. Transparency: the entire flow path and cell can be visually inspected during the assay Enclosed system: no air segmentation. Processed solutions isolated from ambient air. 5 www.flowinjection.com

Low cost replaceable components: No glass coils, no de bubblers, only tubing. Short startup and close down Times: internal volume of system is less that 1/10th that of a typical Auto Analyzer system. 6 www.flowinjection.com