Install the DeviceNet Module using the following procedure:



Similar documents
DeviceNet Communication Manual

CMC-DN01 DeviceNet Slave Communication Card Operation Manual

L5354 ControlNet Communications Interface

4469 en / c. Ready. Run Start. Stop LCL RMT. Reset USB MODULE. Communications module. User Guide

DeviceNet Bus Software Help for Programming an Allen Bradley Control System

Modular I/O System Analog and Digital Interface Modules

DeviceNet Motor Control

Number 1 in efficiency

DCREG INTERFACE VIA DEVICENET

PCS0100en Persy Control Services B.V. Netherlands

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

1 Application Description Objective Goals... 3

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

ZC-24DO CANopen I/O Module: 24 Digital Outputs

User Manual. AS-Interface Programmer

How to make a diagnostic on TeSysT to start the network?

G3 Series PROFIBUS DP Technical Manual

MBP_MSTR: Modbus Plus Master 12

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

DeviceNet Configurator User Guide

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

RS - SPM. Serial parallel translator module

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

Talon and Talon SR User Manual

M-series Virtual I/O Module 2

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April SFC132089M0201 1

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Combi switchbox with integrated 3/2 way pilot valve

Soft-Starter SSW-06 V1.6X - Profibus DP, DeviceNet and EtherNet/IP

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

with Electronic Assistant

CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

User Manual. DeviceNet Network Configuration

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface

R60 USB to CAN interface Manual (1.5 EN)

MLC TM Maximum Productivity and Versatility for Control without Compromise!

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Installation manual. Generator Paralleling Controller GPC multi-line C

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Contents. VLT AutomationDrive EtherNet/IP

Contents. Document information

DeviceNet Communications handbook

User Manual Revision English

User Manual Revision English

Application Unit, MDRC AB/S 1.1, GH Q R0111

MidiStream. UHF Wireless MIDI System Operating Manual

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Linksys WAP300N. User Guide

How To Use A Light Bulb With A Power Supply (Power Supply)

INTRODUCTION FEATURES OF THE ICM

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

User Manual Revision English

VLT 6000 HVAC. Contents

Original instructions. PLUTO Gateway. User Manual. PROFIBUS GATE-P1/P2 DeviceNet GATE-D1/D2 CANopen GATE-C1/C2 Ethernet GATE-E1/E2

PRT3 Printer Module: ASCII Protocol Programming Instructions

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

INSTALLATION MANUAL XM3 Reader

Ethernet/IP Explicit Messaging Using Unity Software

Application/Connection Examples

TRILOGI 5.3 PLC Ladder Diagram Programmer and Simulator. A tutorial prepared for IE 575 by Dr. T.C. Chang. Use On-Line Help

EMBEDDED ACCESS CONTROL Hardware Installation Guide

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version ( )

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Universal Serial Bus (USB) to DH-485 Interface Converter

GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0

User Manual Revision English

Instruction Manual. Cascade Controller Option VLT 6000 HVAC VLT 8000 AQUA

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

AN : Using Wago CANOpen IO

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

How To Use A Network Card With A Network Box (Ios) On A Microsoft Powerbook 2.5 (I2) (I3) (Io2) And I2 (Io) (Net) (Ipo) (

PLUTO Safety-PLC. Manual Absolute Encoders

Digital Keypad Use s Manual

Siemens S7 PLC and FC 300 Profibus

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Addendum to the Operating Instructions

Operational Overview and Controls Guide

Installation guide H A. HSI hardwired system interface

T7560A,B,C Digital Wall Module

Manual. VE.Bus to NMEA 2000 interface

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

IDDERO HOME SERVER. Quick start guide

INDEX. Trademarks All name and product s trademarks mentioned below are the property of their respective companies.

NX Series Inverters. HVAC Pocket Programming Guide

C441 Ethernet module user manual (C441R, C441T, C441U, C441V)

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Installation and User Guide

Transcription:

Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from the soft starter. 2. Attach the DeviceNet Module to the soft starter as illustrated below. 3. Set the DeviceNet Module Node Address (MAC ID) and Data Rate. 4. Apply control power to the soft starter. 5. Insert the network connector into the module and power up the DeviceNet network. MCD 200 MCD 500 177HA368.11 177HA530.10 CAUTION Network designs must decrease the maximum allowable cumulative dropline length by 400 mm for every DeviceNet Module installed on the network. Failure to do so may result in network communication errors and decreased reliability. Example: ODVA specifies a maximum cumulative dropline length of 156 m on a network operating at 125 kb/s. If six DeviceNet Modules were installed on this network, the total cumulative dropline length would need to be decreased to 153.6 m. Remove the DeviceNet Module using the following procedure: 1. Take the module off-line and remove the DeviceNet connector. 2. Remove control power and mains supply from the soft starter. 3. Push a small flat-bladed screwdriver into the slots at the top and bottom of the module and depress the retaining clips. 4. Pull the module away from the soft starter. 177HA378.10 CAUTION Remove mains and control voltage from the soft starter before attaching or removing accessories. Failure to do so may damage the equipment. MG.17.H7.02 - VLT is a registered Danfoss trademark 1

Configuration MCD DeviceNet Module 2. Configuration The DeviceNet Module is a Group 2 slave device, using a predefined master/slave connection set. I/O data is produced and consumed using polled I/O messaging. The soft starter must be added to the DeviceNet manager project using the EDS file and configuration/management software tool. This file is available on the supplied CD or can be downloaded from the website www.danfoss.com/drives. In order to operate successfully, the correct EDS file must be used. Product MCD 200 EDS Filename SSDM04_11.eds MCD 500 SSDM07_12_1.eds An on-screen graphics bitmap file (device.bmp) is available on the supplied CD or can be downloaded from the website www.danfoss.com/drives. 3. Adjustment The factory default settings for the rotary adjustment switches are: DATA RATE 500 kb PGM 250 kb 125 kb NODE ADDRESS ( 00-63, PGM ) 2 4 0 177HA372.11 PGM MSD 2 0 8 LSD 6 4 6 Changes to the rotary switch settings take effect when the DeviceNet network is next powered up. The Data Rate and Node Address (MAC ID) must be set locally on the module. These cannot be set using DeviceNet management software. When the Data Rate and MSD Node Address (MAC ID) rotary switches are set on PGM position, the module uses the previously used valid on-line Data Rate and Node Address (MAC ID). 4. Connection For the DeviceNet Module to accept serial commands, a link must be fitted across terminals A1-N2 on MCD 200 starters. In order for the MCD 500 to accept commands from the serial network, the soft starter must be in Auto On mode and links must be fitted to terminals 17 and 25 to 18. In Hand On mode, the starter will not accept commands from the serial network but the starter's status can still be monitored. MG.17.H7.02 - VLT is a registered Danfoss trademark 2

Module and Network LEDs MCD 200 MCD 500 A1 N2 MCD 200 DEVICENET MODULE MCD500 (Auto On mode) 17 Stop 18 COM 25 Reset DEVICENET MODULE Rd Wh Bu Bk V + CAN_H Shield CAN_L V - 177HA367.11 Rd Wh Bu Bk V + CAN_H Shield CAN_L V - 177HA534.10 Standard connection onto DeviceNet bus Standard connection onto DeviceNet bus If parameter 3-2 Comms in Remote is set to Disable Comms in Remote, the starter will not accept start or stop commands from the serial network (the starter will still accept reset commands and allow status monitoring). 5. Module and Network LEDs The Module LED indicates the condition of the power supply and module operation. The Network LED indicates status of the communication link between the DeviceNet Module and the network Master. LED operation is as follows: Module LED Network LED 177HA366.11 LED State Description Module Off Network power off Green Normal operation Red Unrecoverable fault Red/Green flashing Self Test mode Network Off Duplicate MAC ID test has not been completed Green flashing Online but no connection with Master Green Online and allocated to a Master Red flashing One or more timed out I/O connections Red Failed communication between module and Master Red/Green flashing Communication faulted and received an Identity communication faulted request When a communications failure occurs, the soft starter may trip if the Communication Timeout parameter for the network is set greater than zero. When communication is restored, the soft starter must be reset. MG.17.H7.02 - VLT is a registered Danfoss trademark 3

DeviceNet Polled I/O Structure MCD DeviceNet Module 6. DeviceNet Polled I/O Structure Once the EDS file has been loaded, the DeviceNet Module must be added to the scanner list with parameters shown in the following table: Parameter I/O connection type Poll receive size Poll transmit size Value Polled 14 bytes 2 bytes Once the soft starter, module and Master have been set up, configured and powered up, the Master will transmit 2 bytes of data to the module and receive 14 bytes of data from the module. Master > Slave polled I/O output data is as follows: Byte Bit Function 0 0 0 = Stop command 1 = Start command 1 0 = Enable Start or Stop command 1 = Quick Stop (i.e. coast to stop) and disable Start command 2 0 = Enable Start or Stop command 3 to 7 Reserved 1 = Reset command and disable Start command 1 0 to 1 1 0 = Use soft starter remote input to select motor set 1 = Use primary motor set when starting 2 2 = Use secondary motor set when starting 2 3 = Reserved 2 to 7 Reserved 1 Only available on MCD 500 soft starters. 2 Ensure that the programmable input is not set to Motor Set Select before using this function. Slave > Master polled I/O input data is as follows: Byte Bit Function Value 0 0 Trip 1 = Soft starter trip 1 1 Warning 1 = Soft starter warning 2 Running 0 = Unknown, not ready, ready to start or tripped 1 = Starting, running, stopping or jogging. 3 Reserved 4 Ready 0 = Start or stop command not acceptable 1 = Start or stop command acceptable 5 Control from Net 1 = Always except in Program mode 6 Reserved 7 At reference 1 = Running (full voltage at the motor) 1 0 to 7 Status 0 = Unknown (menu open) 1 2 = Starter not ready (restart delay, thermal delay or run simulation) 1 3 = Ready to start (including warning state 1 ) 4 = Starting or running 5 = Soft stopping 7 = Trip 8 = Jog forward 1 9 = Jog reverse 1 2 0 to 7 Trip/Warning code See trip code table below 3 0 Initialised 1 = Phase sequence bit is valid (bit 1) after 1 st start 1 Phase sequence 1 = Positive phase sequence detected MG.17.H7.02 - VLT is a registered Danfoss trademark 4

DeviceNet Polled I/O Structure 2 to 7 Reserved 4 2 0 to 7 Motor current (low byte) 5 2 0 to 7 Motor current (high byte) 6 2 0 to 7 Current %FLC (low byte) 7 2 0 to 7 Current %FLC (high byte) Current (A) 3 8 2 0 to 7 % Motor temperature Motor thermal model 9 0 to 7 Reserved Current as a percentage of soft starter FLC setting (%) 10 1 0 to 7 % Power factor Percentage power factor (100 = power factor of 1) 11 1 0 to 7 Power (low byte) Power low byte, scaled by power scale 12 1 0 to 3 Power (high nibble) Power high nibble, scaled by power scale 4 to 5 Power scale 0 = Multiply power by 10 to get W 1 = Multiply power by 100 to get W 2 = Power (kw) 3 = Multiply power by 10 to get kw 6 to 7 Reserved 13 0 to 7 Reserved 1 Only available on MCD 500 soft starters. 2 Only available on MCD 202 and MCD 500 soft starters. 3 For MCD 500 models MCD5-0068B and smaller this value will be 10 times greater than the value displayed on the LCP. MG.17.H7.02 - VLT is a registered Danfoss trademark 5

DeviceNet Polled I/O Structure MCD DeviceNet Module 6.1. Trip Codes Code Trip Type MCD 201 MCD 202 MCD 500 0 No trip 11 Input A trip 20 Motor overload (thermal model) 21 Heatsink overtemperature 23 L1 phase loss 24 L2 phase loss 25 L3 phase loss 26 Current imbalance 28 Instantaneous overcurrent 29 Undercurrent 50 Power loss (Power circuit) 54 Phase sequence 55 Frequency (Mains Supply) 60 Unsupported option (not available in inside delta) 61 FLC too high (FLC out of range) 62 EEPROM fail 70 Miscellaneous 75 Motor thermistor 101 Excess start time 102 Motor connection 104 Internal fault 113 Starter communication (between module and soft starter) 114 Network communication (between module and network) 115 L1-T1 shorted 116 L2-T2 shorted 117 L3-T3 shorted 119 Time-overcurrent (Bypass overload) 121 Battery/Clock 122 Thermistor circuit MG.17.H7.02 - VLT is a registered Danfoss trademark 6

Parameter Object 7. Parameter Object The DeviceNet Module supports parameter objects through explicit messaging. Soft starter parameters can be uploaded (written) and downloaded (read) using DeviceNet management software. When the DeviceNet Module is powered up, it automatically obtains parameter information from the soft starter. Detail Value (Hex) Comment Class 0F Parameter object address Instance 1 ~ xxx xxx = maximum soft starter parameter number Attribute ID 01 Always 0x01 Get Service 0E Read single soft starter parameter value Set Service 10 Write single soft starter parameter value Only available on MCD 500 soft starters. For parameter details, see the soft starter User Manual. The numbering of parameter options via serial communications differs slightly from the numbering displayed on the LCP. Numbering via the DeviceNet Module starts at 0, so for Par. 2-1 Phase Sequence, the options are 1~3 on the LCP but 0~2 via the module. 8. Specifications Enclosure Dimensions... 35 mm (W) x 157 mm (H) x 90 mm (D) Weight... 250 g Protection... IP20 Mounting Spring-action plastic mounting clips (x 2) Connections Soft starter... 6-way pin assembly Network... 5-way male and unpluggable female connector (supplied) Maximum cable size... 2.5 mm 2 Contacts... Gold flash Settings Node address (MAC ID) Setting... Rotary switches Range... 0 to 63 (63, factory default) Data rate Setting... Rotary switch Options... 125 kb, 250 kb, 500 kb (125 kb, factory default) Power Consumption steady state... 19 ma at 25 VDC... 31 ma at 11 VDC in-rush (at 24 VDC)... 1.8 A maximum for 2 ms Galvanically isolated Certification C... IEC 60947-4-2 CE... IEC 60947-4-2 ODVA... DeviceNet Conformance Tested MG.17.H7.02 - VLT is a registered Danfoss trademark 7