Phase-Adaptive Power Module



Similar documents
Switching Power Module

LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module

How To Use A Lutron Power Supply

RF Maestro Local Controls

GRX-PWM Pulse Width Modulation Interface

DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

HomeWorks QS Processor

Control Interfaces. GRAFIKR Systems a LUT-DMX

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

Remote Power Panels with Breakers

New Architectural Accessories

GLPHASE System. System Components GLPHASE - KP- KP- KP- KP- OS- DS SpaceBuild Specification Worksheet. Touch Screens

LED DIMMING A HELPFUL GUIDE...

QSE-CI-DMX Control Interface

QSE-CI-NWK-E Control Interface

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

12V Dimmable Driver EL-TMDRVR

15 Series - Electronic step relay and dimmer. Features SERIE

INSTALLATION INSTRUCTIONS

Maestro Wireless Dimmers and Switches

Arc Fault Circuit Interrupters Frequently Asked Questions

How To Test A Power Distribution Unit

STRATO LED Drivers 70W, Single output

Preset Scene Dimmer with Infrared Remote Control

8146/5 Series Breaker Panelboards

Controls SPECIFICATION SUBMITTAL. MAESTRO CONTROLS. The High-Tech Multi-Location Dimmer

SECTION LOW VOLTAGE LIGHTING CONTROLS

Three-Phase Electric Power Distribution for Computer Data Centers

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

LIGHTING and LIGHTING SYSTEMS

CompactLogix Power Supplies Specifications

Installation Instructions

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

Installation and User Guide

Lutron architectural accessories & wallplates

LIEBERT VNSA Installation Sheet

Dimmer and Bulb Compatibility

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

1 light dimming module

TrueAlarm Fire Alarm Systems

Design guide EcoSystem

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Type FLX Freezer Floor Frost Heave Protection DESIGN GUIDE

Video Conference Indirect Wash LED Fixture

Linear Recessed Center Basket Fixture. Lutron

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Manual Switches Series 2 Pushbutton Switches and Indicators

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Emergency lighting units EM powerled

Lighting Control Systems

Architectural Lighting Control System

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Home Dimming System. Product Family Features. Specification Features. Integration. Color Palette (For latest color information, visit

SECTION INTERIOR LIGHTING FIXTURES, LAMPS, AND BALLASTS

Lightning Arresters P KVA P KVA. Description & Installation

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Circuit Breaker. Description

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

Operation Manual. Trans-Flo

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

LED Sign Module. LED Super Tiny Strip. LED Accessories. LED Power Supply

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

MCR1900 Media Converter 19-Slot Chassis

G H I J K G DIMMING. QS no dimming 1 0. (10%) 3-wire hot dim EcoSystem (10%) digital dim U 0 Mark 7 (1% HO 5% HE) 0-10 V M 0 Mark 10 (1%) hot dim N 0

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

OMX-RS232 Control Interface

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Product and functional description

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Radiant Temperature Sensor TY7321

Engineers Edge, LLC PDH & Professional Training

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

Constant-Voltage vs. Constant-Current LED Drivers

Circuit Breakers. NRC Series. NRC Series

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

HomeWorks QS Wired seetouch Designer Keypads

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Understanding LED Drivers

XLD200. Plug-and-Play Multi Channel 200 Watt LED Driver. UL/cUL Listed LED Drivers. Model Selection Key XLD200-ABBV-FC. The LED Driver Expert

SECTION VARIABLE FREQUENCY DRIVES

Dual Technology Ceiling Mount Sensor

Transcription:

369356c 1 06.22.16 Description Provides capability for a zone on a GRAFIK Eye control unit (or other product) to dim a fully loaded circuit of lighting. May be used to control incandescent, electronic lowvoltage, magnetic low-voltage, and neon / cold cathode lighting sources, as well as Lutron Tu-Wire fluorescent dimming ballasts. Automatically selects leading-edge or trailing-edge dimming for low-voltage transformers. Provides power and dimming for one zone. Up to 3 power modules may be wired on a single GRAFIK Eye zone. Models available for control power. Models available for or 120-277 V~ load power. ot for use with non-dim loads. Works with versions of: GRAFIK Eye QS control units 1 GRAFIK Eye 3000 Series control units 2 LP, LCP, and GP dimming panels 2 HomeWorks and HomeWorks QS remote power panels** Lutron 3-wire fluorescent dimmers (consult Lutron for Vierti ); see approved list in the dimmers & switches specification guide at www.lutron.com Models and Capacities Model umber Control Power Power Capacity PHPM-PA-DV-WH 120 277 V~ 16 A PHPM-PA-120-WH 16 A 1 Set to power module load type 2 Set to incandescent load type Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber:

Specifications 369356c 2 06.22.16 Regulatory Approvals UL listed CSA certified OM certified Complies with requirements for use in other spaces used for environmental air (plenums) per EC 2014 300.22(C)(3) Power Control voltage: voltage: only for PHPM-PA-120-WH 120 277 V~ for PHPM-PA-DV-WH Capacity: Full 16 A : 1920 W 120 277 V~: 1920 4432 W Frequency: 50 / 60 Hz, phase-to-neutral. (output) power: Phase independent of control device / control voltage. Sources / Types Operates these sources with a smooth continuous Square Law dimming curve: Incandescent (tungsten) Halogen Magnetic low-voltage transformer (iron core) Electronic (solid-state) low-voltage transformer (must be manufacturer approved for reverse-phase control dimming) eon / Cold cathode Lutron Tu-Wire fluorescent dimming ballasts Incandescent and electronic low-voltage sources may be controlled on the same circuit / control zone. Up to 30% of the unit s capacity may be used for incandescent lighting. Incandescent and magnetic low-voltage sources may OT be controlled on the same circuit / control zone. PHPM-PA not for use with non-dim loads. Use switching power module (PHPM-SW-DV-WH) for nondim loads. Minimum load on power module is 10 W. Output must be directly connected to the load. side switching is not recommended. Key Design Features Automatically selects between forward phase / leading edge (e.g., magnetic low-voltage) and reverse phase / trailing edge (e.g., electronic low-voltage) dimming / output based on connected load. Patented RTISSTM circuitry compensates in real time for incoming line voltage variations: Compensates for +/-2% change in RMS voltage / cycle and +/-2% Hz change in frequency/second. Provides air-gap off. Module protects itself during most temporary overcurrent and over-voltage conditions. Two LEDs on front of unit provide diagnostic information (visible when faceplate is removed). Terminals Each terminal accepts up to two 12 AWG (2.5 mm 2 ) wires. Environment 32 F to 104 F (0 C to 40 C). Relative humidity less than 90% non-condensing. Indoor use only. Maximum heat output of module: 135 BTU / hour. Mounting Surface- or recess-mount. SPECIFICATIO SUBMITTAL Page Job ame: Model umbers: Job umber:

Dimensions All dimensions shown as: in (mm) 369356c 3 06.22.16 1.2 (30.5) 5.1 (129.5) 1.4 (35.5) 6.3 (160) Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber:

Mounting 369356c 4 06.22.16 Mount in 2-gang U.S. wallbox 3.5 in (89 mm) deep or 4 in x 4 in (102 mm x 102 mm) junction box 2.1 in (53 mm) deep. Indoor use only. This device generates heat; mount only where ambient temperature is 32 F to 104 F (0 C to 40 C). Mount with arrows facing up to ensure adequate cooling. Allow 4.5 in (114 mm) above and below unit and between faceplates when mounting several in a vertical layout. Mount so line (mains) voltage wiring is at least 6 ft (1.8 m) from sound or electronic equipment and wiring. Mount within 7 of true vertical. Mount to 2-gang U.S. wallbox Mount to 4 in x 4 in (102 mm x 102 mm), 2.1 in (53 mm) deep U.S. junction box Mount to 4 in x 4 in (102 mm x 102 mm), 2.1 in (53 mm) deep U.S. junction box with barrier (for 277 V~ model if required by local electrical code) Barrier Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber:

Wiring 369356c 5 06.22.16 Pull 12 AWG (2.5 mm 2 ) copper (Cu) wires [167 F (75 C) minimum] for input power and load circuit. Strip 1/2 in (12 mm) insulation from wires before connecting. Run separate neutral for load circuit - no common neutrals. May be used with GFI breaker protected loads. circuit wiring (from GFI breaker to power module to load) must be run in its own non-metallic conduit, or nuisance tripping may occur. Maximum 100 ft (30.5 m) between power module and load. May be used with AFI breaker protected loads. Maximum load on AFI circuit is 1000 W. Exceeding 1000 W may cause nuisance tripping of AFI breaker. Single Power Feed The power module may be on the same circuit as the control unit only if the total load does not exceed the rating of the breaker. Circuit breaker GRAFIK Eye QS 1 2 3 4 5 6 L Wire to appropriate zone Control eutral Legend L /H Line / Hot eutral Switched Hot Dimmed Hot Ground ot Used Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber:

Wiring (continued) 369356c 6 06.22.16 Multiple Power Feeds The load breaker may be on a different phase than the control breaker. GRAFIK Eye QS 1 2 3 4 5 6 L Wire to appropriate zone Control breaker breaker wiring 1 Control eutral Legend L / H Line / Hot eutral Switched Hot Dimmed Hot Ground ot Used 1 feed: for PHPM-PA-120-WH; 120 277 V~ for PHPM-PA-DV-WH Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber:

Wiring (continued) 369356c 7 06.22.16 Multiple to a Single GRAFIK Eye Zone Shown with separate feeds for control and loads. All breakers must be turned off prior to installing or servicing the modules. Up to 3 power modules may be wired to a single zone. GRAFIK Eye QS 1 2 3 4 5 6 L Wire to appropriate zone breaker Control breaker wiring 1 for Power Module #1 Control eutral breaker wiring 1 for Power Module #2 Control eutral breaker wiring 1 for Power Module #3 Control eutral 1 feed: for PHPM-PA-120-WH; 120 277 V~ for PHPM-PA-DV-WH Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber:

Wiring (continued) 369356c 8 06.22.16 Multi-location Wiring The power module may be on the same circuit/control zone as the control device only if the total load does not exceed the rating of the breaker ( only). Circuit breaker wiring 1 Control eutral Legend Line / Hot eutral Switched Hot Dimmed Hot Ground ot Used (yellow or orange wire) 3-wire fluorescent dimmer (main dimmer) (red wire) Cap off 3-wire fluorescent dimmer (accessory/ companion dimmer or 3-way switch) For specific wire colors, see the wallbox lighting controls catalog at www.lutron.com/wallbox catalog 1 feed: for PHPM-PA-120-WH; 120 277 V~ for PHPM-PA-DV-WH Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber:

Wiring (continued) 369356c 9 06.22.16 Wiring a Power Module to an LP, LCP, GP, or HomeWorks Panel Up to three 3-wire fluorescent power modules may be wired to an output of a LP or LCP panel. The load type for the output must be set as Eco-10 or Hi-lumeR fluorescent load type on the panel s circuit selector (for an LP or GP panel), controller (for an LCP panel), or HomeWorks software (for a HomeWorks panel). Wire to appropriate output wiring 1 Zone In Control eutral (1) 14 to 10 AWG (2.0 to 4.0 mm 2 ) (1) 14 to 10 AWG (2.0 to 4.0 mm 2 ) Dimmed Hot eutral H 1 feed: if used with PHPM-PA-120-WH power module; 120 277 V~ if used with PHPM-PA-DV-WH power module Branch Circuit Breakers eutral Lug Power (Line / Hot) (3) 14 to 2/0 AWG (2.0 to 70 mm 2 ) eutral (1) 14 to 2/0 AWG (2.0 to 70 mm 2 ) Job ame: SPECIFICATIO SUBMITTAL Page Model umbers: Job umber: