THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles



Similar documents
Gas Chromatography Liner Selection Guide

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Series 2. Air Server. Options for UNITY 2. A robust, cryogen-free solution for round-the-clock on-line air monitoring

Split / Splitless Injection for Capillary GC

23 The Thermal Conductivity Detector

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

SCION SQ Series GC-MS

A Comparison between EPA Compendium Method TO- 15 and EPA Method 8260B for VOC Determination in Soil Gas

Fractional Distillation and Gas Chromatography

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Series 2. Continuous monitoring of trace chemical vapours

Analyzing Small Molecules by EI and GC-MS. July 2014

ß-CYCLODEXTRIN SYNONYMS

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Transformer Oil Gas Analysis

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

Thermal Conductivity Detector

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Diffusion and Fluid Flow

Air Sampling for Gases and Vapors. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH Johns Hopkins University

Multi-Shot Pyrolyzer EGA/PY-3030D. Flexible Versatile Reproducible

ORGANIC SAMPLE PREPARATION

Paper Chromatography: Separation and Identification of Five Metal Cations

Agilent 7697A Headspace Sampler Data Sheet

The Use of Hydrogen Carrier Gas for GC/MS

Purification of reaction mixtures using flash chromatography.

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

Micro Cryo-Trap Model 971

Electrospray Ion Trap Mass Spectrometry. Introduction

Theory and Instrumentation of GC Introduction

On-line Dissolved Gas Analysis

Cartridge Change Schedule

105 Adopted:

Description of Thermal Oxidizers

Stainless Steel Pipe Fabrication

The Theory of HPLC. Gradient HPLC

Mass Spectrometry. Fundamental GC-MS. GC Considerations

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

MERCURY REMOVAL FROM NATURAL GAS & LIQUID STREAMS. John Markovs UOP Des Plaines, Illinois. Jack Corvini UOP Houston, Texas

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

MERCURY REMOVAL FROM NATURAL GAS AND LIQUID STREAMS ABSTRACT. Giacomo Corvini, Julie Stiltner and Keith Clark UOP LLC Houston, Texas, USA

DURR Thermal Oxidizer Research. 4/27/2004 Intel Corporation Community Meeting

Thermal Desorption Unit TDU

Pesticide Analysis by Mass Spectrometry

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

Addressing the World Helium Shortage For Gas Chromatography

BTU ANALYSIS USING A GAS CHROMATOGRAPH

Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

AMD Analysis & Technology AG

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Hydrogen as an alternative to Helium for gas chromatography.

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Adsorption air dryers ADS 1 215

On-line Ozone Precursor Analyzers From the Leader in Thermal Desorption Technology

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETER (DSC) Insert Nickname Here. Operating Instructions

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

GC-xt. The most flexible GC /GC-MS liquid sample injector

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

Nitrogen Blanketing for Methanol Storage and Transportation

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Gas Chromatograph GC Consumables. p/n:

METHOD 3510C SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION

Indoor Air Comfort Test Report

Rheodyne Manual Sample Injector Valves

Enhancing Utility and Throughput of SPME using Advanced Automation Strategies

How To Test For Contamination In Large Volume Water

Expectations for GC-MS Lab

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# RFQ)

Chapter 28: High-Performance Liquid Chromatography (HPLC)

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Process Instrumentation

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Flow Injection Analysis

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Unit 1 - Pure Substances and Mixtures Chapter 2: Solutions

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

AN INTRODUCTION TO HEADSPACE SAMPLING IN GAS CHROMATOGRAPHY FUNDAMENTALS AND THEORY. Andrew Tipler

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

Anion chromatography using on-line recycled eluents

Identification of Arson Accelerants by Gas Chromatography

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

CHROMOCTANE O N LINE ANALYZER

Chapter 12 - Liquids and Solids

Transcription:

THERMAL DESORPTION Introduction and Principles

Thermal Desorption Thermal desorption is a simple extension of the technique of gas chromatography (GC) It involves the use of heat and a flow of inert gas to extract volatile and semivolatile organics from a solid sorbent or other sample matrix The analytes are extracted into the stream of inert gas and are transferred to the GC in a small, discreet and concentrated volume of vapor.

Benefits of Thermal Desorption Versus Solvent Extraction Versatility Detection limits enhanced by a factor of 10 3-10 4. This makes thermal desorption compatible with both indoor and outdoor air monitoring as well as industrial hygiene. Reliable, 95% or better desorption efficiencies for all VOCs, including polar compounds, versus 30-80% for most solvent extraction methods.

Benefits of Thermal Desorption Versus Solvent Extraction - Continued Cost saving No manual sample preparation thus reducing time and cost per analysis Reusable tubes - Thermal desorption tubes are reusable 100-200 times. At 30 per tube this equates to < 30p per analysis. Reduced consumable costs No solvent disposal costs and associated overhead expense No expensive air extraction equipment required

Benefits of Thermal Desorption Versus Solvent Extraction - Continued No solvent required No masking of peaks of interest by the solvent (especially important with MS) No introduction of artifacts/impurities from the solvent No solvent selection issues with respect to materials analysis Improved laboratory working environment Eliminates a health hazard. - CS 2 is the most commonly used extraction solvent. This is a very hazardous chemical and exposes the analyst to unacceptable air pollution

Thermal Desorption - Applicability Used for the analysis of volatile or semivolatile organics in sample matrices that cannot be directly introduced to the analyser/detector e.g... dilute vapor-phase samples such as polluted air or breath solids - powders, film, fibres, granules resins - adhesives, pastes tooth paste, ointment emulsions - paint, blood salt or sugar solutions

What Will Thermal Desorption Handle? Any organic compound, volatility > n-c 40, which is easily gas chromatographed........ PROVIDED the sorbent or matrix containing the analytes is compatible with the high temperatures required

What Won t It Do? Compounds which are not compatible with gas chromatography Compounds with volatility < n-c 40 Compounds which require special care during GC analysis, e.g., on-column injection Most inorganic (permanent) gases - exceptions include N 2 O, SF 6 and CS 2

Limitations of Single Stage Desorption Sample GC Direct transfer of analytes from the sample to the GC is called single stage thermal desorption. It invariably takes at least a minute, often several minutes, to complete the analyte transfer. This long injection time produces very broad peaks.

2-Stage Desorption Using a Large Sorbent Trap at Ambient Temperature Split on Inlet to Cold Trap Primary (Tube) Desorption Hot Sample Tube Ambient Trap Split on Outlet to Trap Secondary (Trap) Desorption Cooling Sample Tube Hot Trap Broad Peaks

Single Stage Desorption or Focusing on Ambient Traps Produces Broad Peaks 4 mm ID Tube to 2 mm ID Tube to Column 4 mm ID Tube to Column Acetylene Ethylene Ethane 0 2 4 Min. 0 2 4 Min.

2-Stage Desorption Using Capillary Cryofocusing Split on Inlet to Cold Trap Primary (Tube) Desorption Hot Sample Tube Capillary cryofocusing Secondary (Trap) Desorption Split on Outlet to Trap Cooling Sample Tube Hot Capillary

Disadvantages of Capillary Cryofocusing High consumption of liquid cryogen (sometimes over 2 L per hour) Capillary systems easily plug with ice Permanent gases such as CO 2, nitrogen and OXYGEN may also be retained and cause analytical instability

2-Stage Desorption Using a Small, Packed, Electrically-Cooled Trap Split on Inlet to Cold Trap Primary (Tube) Desorption Hot Sample Tube Cold Trap Split on Outlet to Trap Secondary (Trap) Desorption Cooling Sample Tube Hot Trap

Advantages of Small, Packed, Electrically-Cooled Traps No liquid cryogen required Quantitative retention, even of very volatile components such as ethane Desorption in backflush mode gives quantitative recovery of analytes over a wide boiling range Rapid (60 deg/sec) desorption gives narrow capillary peaks with no additional focusing required High sensitivity and short analysis times No risk of ice plug formation blocking the sample flow path

Peak Shape from UNITY with no On- Column Focusing 1.6 seconds wide at half height 2.18 2.21 2.24 2.27 2.30

Speciated VOC Monitoring: An Overview of the Analytical Process Sampling - Selective concentration - Desorption - Transfer - Measurement On-line Cryogen free cold trap Canisters/ bags ~200 ul injection of vapour Tubes GC / GC-MS

2-Stage Thermal Desorption: Electrically- cooled, Sorbent-packed Focusing Trap Narrow bore end - Sample in and out

Concentration Enhancement Potential Using Pumped Sorbent Tubes and 2-stage 2 TD Pumped sample volume: typically 5-100 L of air Desorb tube in 100-200 ml of carrier gas and transfer effluent to focusing trap Desorb focusing trap in 200-300 ul of carrier gas and transfer the effluent to the analytical system without band dispersion Overall concentration enhancement potential ~ 10 5 - even 10 6 if 100-200 L sample volumes are collected

Off-line Sampling: Sorbent Tubes Standard, stainless/sulfinert steel tubes Retaining spring + rear gauze Sampling end Sorbent bed Front gauze Summary information: ¼ external diameter x 3 ½ long Accurate positioning of sorbent retaining gauzes in metal tubes allow these to be used for diffusive and pumped sampling. Also ensures all of bed in heated zone essential for passive sampling Glass tubes have same external dimensions but narrower I.D. Sorbent retained by glass wool. Thay are not suitable for diffusive sampling

Concentration Enhancement Potential: Whole-Air/Gas - Canisters, Bags, On-line Typically 200-2000 ml of air passed through focusing trap Focusing trap desorbed in as little as 200 ul of carrier gas and the effluent transferred to the analytical system without band dispersion Single stage only - Overall concentration enhancement potential 10 3-10 4

Off-line Sampling: Passivated Stainless Steel Canisters Protective Shield Valve Summa Passivated Interior 6L Volume typically used for samples

Thermal Desorption - Key Parameters Being an extension of gas chromatography, thermal desorption methods are optimised by adjusting the following key parameters: Temperature Gas flow Time (Sorbent / packing)

Optimising TD Methods for Sorbent Tubes - Primary (Tube) Desorption Temperature: As hot as possible within the constraints of sorbent or sample matrix stability Gas flow: As fast as possible through the tube Time: Just sufficient for complete (or representative) desorption of target analytes from the tube or for selective elimination of interfering compounds from the cold trap (if applicable), whichever is longer. Tube packing (where applicable): Strong enough for quantitative retention during sampling; weak enough for quantitative desorption during analysis

Optimising TD Methods for Sorbent Tubes - Cold Trapping during Primary Desorption Sorbent(s): Strong enough to retain analytes during primary desorption; weak enough for quantitative desorption of target analytes during secondary desorption; weak enough also for selective elimination of interfering volatiles Temperature: Cold enough for quantitative retention of target analytes while allowing volatile interferents to pass through unretained to vent Gas flow: Sufficiently slow to prevent premature breakthrough of target analytes Time: Long enough to allow selective elimination of interfering compounds but otherwise as short as possible to minimise risk of analyte losses

Optimising TD Methods for Sorbent Tubes - Secondary (Trap) Desorption Temperature: Hot enough for rapid, quantitative desorption of target analytes Gas flow: As fast as possible within the constraints of method detection limits

Selection of the Correct Sorbent(s) for the Sample Tube Ensures. No breakthrough during sampling and Quantitative recovery during thermal desorption..with less than 1 g of adsorbent. Standard, small - 1/4-inch O.D. - sorbent tubes are easy to condition, easy to desorb, quick to purge with carrier gas and inherently less subject to artifact formation than larger 5/8-inch O.D. tubes.

Two-Stage Thermal Desorption - A Complete Analytical Sequence Standby (split or splitless) Tube load Leak test (no flow / no heat / high pressure) (dry purge - in sampling direction) pre-purge - ambient temperature to remove air (to split and/or trap) (pre-purge - elevated temperature - invariably to split) primary (tube) desorption (split or splitless) Secondary trap desorption (split or splitless) and initiation of the GC(-MS) analysis

Why Backflush the Cold Trap? Hot Sample Tube Split on Inlet to Cold Trap Split on Outlet to Trap Cold Trap Primary (Tube) Desorption Secondary (Trap) Desorption To allow use of multisorbents in series and thus extend the analyte volatility range To minimise desorption times / volumes Because it says so in std methods like TO-17 Cooling Sample Tube Hot Trap

Why Do You Need a Heated Inert Valve in the TD Sample Flowpath? TD: Flow-through, valve-free configuration Split on inlet and/or outlet to cold trap GC(-MS) analyser Sample tube Cold trap To isolate the cold trap from the carrier gas flow during standby and thus prevent its contamination with carrier gas artifacts To carryout a no-flow, low temp, high-pressure, pre-desorption leak test as required by standard methods To allow dry-purging of tubes in the sampling direction (per std methods)

Why Do You Need a Heated Inert Valve in the TD Sample Flowpath? TD: Flow-through, valve-free configuration Split on inlet and/or outlet to cold trap GC(-MS) analyser Sample tube Cold trap To allow purging of air from the tube before desorption without any of that air being allowed to reach the analytical column and detector To allow selective elimination of volatiles (e.g water, solvent) from the cold trap during primary desorption without the purged compounds reaching the GC column and detector To prevent quantitation errors due to premature migration of the solvent from the trap to the GC

Why Do You Need a Heated Inert Valve in the TD Sample Flowpath? TD: Flow-through, valve-free configuration Split on inlet and/or outlet to cold trap GC(-MS) analyser Sample tube Cold trap To allow leak-testing, purging, primary desorption, etc of a subsequent sample while GC analysis of a previous sample is ongoing (optimises throughput) To prevent high boiling components still eluting from the sample tube from migrating slowly onto the hot trap and causing peak ghosting To allow backflush desorption of the cold trap To isolate the sample tube from the cold trap during secondary desorption

Why Do Injector Liners Not Make Suitable Sample Tubes? Non-standard tubes - i.e do not comply with standard methods Single stage desorption - broad peaks Desorption of the outside walls of the tube as well as its contents which introduces artifacts from sample handling Single split only The only possibility for focusing involves liquid cryogen cooling of the capillary analytical column All the limitations just described in connection with flow-through thermal desorption - No leak test, air reaching system, no selective purging of solvent (without some of the purged compounds reaching the GC column and detector), no dry purge option, etc, etc