Springlok Flashing System



Similar documents
ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

GUIDELINE SPECIFICATIONS

PART 1 GENERAL 1.1 SECTION INCLUDES

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

PERIMETER FLASHING. Table of Contents

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

SECTION STANDING SEAM METAL ROOFING

Preformed Metal Roofing and Siding

SECTION STANDING SEAM METAL ROOF

SECTION METAL ROOF & WALL PANELS

WINDOW PANNING AND TRIMS

Standing Seam Roof Systems

metal Duil~ing manufacturers Association

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

Rouse Life Sciences Roof Repair or Replacement SECTION

STANDING SEAM SHEET METAL ROOFING

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ 36.

Sun Windows General Information Sun New Construction Window Installation Instructions

The Harold J. Becker Company, Inc.

Ver. 2. Guide to. Inspecting Residential Brick Veneer

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS WINDOWS

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick

Slim Seam Architectural Design Manual

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

Introduction...COMB-2 Design Considerations and Examples...COMB-3

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

application instructions

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION ROOFING TILE

JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC ALUMINUM WINDOWS Guide Specs

Roof Curbs, Extensions and Equipment Supports

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

238T Standing Seam Metal Roof System (SSMRS)

Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick ARCHITECTURAL SPECIFICATIONS / CAD MODELS TVISTM WARRANTIES

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Important Information for Installer & Homeowner

SECTION STANDING SEAM METAL ROOFING

UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS

SECTION METAL ROOF SYSTEM

CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000

Williamson and Associates, Inc. Report of Building Exterior Condition Evaluation, dated January 2 nd, (68 pages)

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

DENVER MODEL 30 X 30 SPECIFICATIONS

City of San Diego, CWP Guidelines

March 14, Installation of Bay, Bow and Garden Windows

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

INSTALLATION INSTRUCTIONS for Vinyl Windows without Nailing Fin (JII011) ImPOrTANT INFOrmATION & GlOssAry. rough OPeNINGs

The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

Coastal Metal Service

TARRANT COUNTY DETAIL STANDARDS

Tundra Series Windows January 2016

COLORADO MODEL. 35 x 65 SPECIFICATIONS

Table of Contents. I. Roof Scuttles

SECTION STORM DRAINAGE SYSTEM

Quality You Can Trust Since From North America s Largest Roofing Manufacturer

INDUSTRIAL ROOFING CASE STUDY: The Advantages of Aluminized Stainless Steel. Roof Installed:

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Metal Building Systems Installation and Flashings & Details Guide. Table of Contents

SELF-STORAGE BUILDINGS

ISO Types 1-6: Construction Code Descriptions

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

Garden Window. Montecito Series Vinyl Garden Window Architectural Manual

SECTION PREFORMED METAL STANDING SEAM ROOFING

CENTRIA SRS3 Structural Standing Seam Metal Roof Panels

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

PRODUCT SPECIFICATIONS

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

AAMA Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

SERIES 238 WINDOWS. NOTE: Read instructions completely before attempting any installation.

Titan Old World Spanish Tile

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

CHAPTER 7: Building Systems ROOFING SYSTEMS

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

PANELIZED HOME INSTALLATION GUIDELINE

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra Includes:

Chapter 3 Pre-Installation, Foundations and Piers

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

A. Double lock standing seam, single element, metal roof panels.

WATER LEAKAGE IN GLAZED CURTAIN WALL SYSTEMS:

Transcription:

Springlok Flashing System

Why Fry Reglet? Fry Reglet s comprehensive selection of moisture prevention products offer the ultimate in protection from the elements. Available nationwide in a variety of materials and finishes, Fry Reglet offers five pre-engineered flashing systems tailored for specific substrates all designed, tested and proven to keep wind and moisture from getting under the roof. Plus, Fry Reglet provides a complete solution with drawings, installation instructions and the best technical support in the industry. SPRINGLOK SYSTEM Fry Reglet s SpringLok Flashing System offers architects, contractors and owners much more than ordinary field-fabricated components. SpringLok is a pre-engineered system of flashing and reglets designed to secure the roof and prevent uplift in high winds. Parapet Wall Introduced more than 50 years ago, The SpringLok Flashing System has proven superior to other roof flashing systems and field flashing. Most roof Sealant failures begin at the perimeter and spread inward. The SpringLok Flashing System uses the relationship between our pre-engineered reglet and flashing to Reglet create resistance, or spring to hold the flashing tight against the parapet wall. In fact, each of our five reglets Flashing have been tested in accordance with ASTM D3161 Wind Resistance and, regardless of base metal, withstood sustained air velocity of 110 mph for two hours without evidence of uplift. Fry Reglet SpringLok Flashing System is pre-engineered and roll-formed to precise specifications to provide Roofing superior results that can not be duplicated or replicated by brake-formed flashing. * Specifier Note: Check your local code requirements for the suitability of.025 aluminum reglets and flashing in your area.

Save Time and Labor Bending flashing on the job involves time, skill and most importantly, liability. Save yourself the hassle and the headaches with pre-engineered Fry Reglet flashings and reglets for virtually any substrate. Our reglets and flashing are roll-formed to precise factory standards unmatched by field brake-form presses. So while you re saving all that time and labor, you ll be saving money too. CO CONCRETE REGLET FEATURES Flashing snaps in under the reglet so water can t get under the flashing. A 1 end lap on the reglet and a 3 end lap on the flashing allows for proper alignment and eliminates leaky butt joints to ensure a watertight seal. Flashing has a positive air break to prevent water from climbing under the flashing. SpringLok flashing systems have been tested and proven to resist sustained wind velocities up to 110 mph for two hours. EASY TO INSTALL & USE Lightweight material is manufactured in 10 lengths for easy handling and installation on the job site. Precision, factory produced parts ensure a perfect fit on the job. Order factory fabricated reglet and flashing corners and eliminate time-consuming site fabrication. SpringLok flashing snaps into reglets without screws or clips, which means you can detach and reuse it when you need to reroof. For use with poured-in-place concrete construction, this reglet is covered with a protective foam backer rod to prevent grout and concrete from getting into the reglet opening. Connector clips are supplied to provide positive alignment at joints and prevent concrete leakage during pouring. Special staples are supplied to aid installation. This system is not recommended for tilt-up construction; use SM surface mounted reglet instead. Galvanized steel - 26 ga. 1 1 /8 3/4 SPRINGLOK Galvanized steel - 26 ga. 5 1 /8 CO REGLET

Failure is Not an Option Choose the roof flashing with a half century history of success in the field Fry Reglet, the most recognized and specified brand of flashing in the nation. In over 50 years, our patented SpringLok Flashing System has never had a reported failure. And, it is the only flashing system to pass ASTM D3161 2-hour, 110 mph wind load test. MA MASONRY REGLET Specially manufactured for masonry applications, this reglet is laid into masonry joints and held in place as the mortar cures. As a result, there is no opening for water penetration. Type MA reglet has a 1 1 /2 top flange for brick; Type MA-4 has a 4 top flange for concrete block. Galvanized steel - 24 ga. Galvanized steel - Kynar 500/Hylar 500 finish or factory applied powder paint in standard Fry Reglet colors 1 1 /8 for Brick 4 for Concrete Block SM SURFACE MOUNTED REGLET SM reglet is designed for installation on any type of parapet wall, including tilt-up panels, precast panels, masonry and other smooth surfaces. Reglets are surface mounted with drive pins which are sealed with special washers (7/8 diameter stainless steel with neoprene facing). Factory punched slots 16 o.c. allow for expansions and eliminate buckling away from the building. System requires polyurethane, polysulfide or silicone sealant at time of installation in two places, at top and in recess, to seal against water penetration. Galvanized steel 24 ga. Copper 16 oz. Aluminum 0.025 Stainless steel, Type 304 0.020 Galvanized steel Standard zinc finish Galvanized steel Factory applied Kynar 500/Hylar 500 finish or factory applied powder paint in standard Fry Reglet colors Copper Standard uncoated finish Aluminum Gray polyester coating Stainless steel, Type 304 Standard uncoated finish 1 1 /8 SEALANT 2 1 /2 MA REGLET SM REGLET

Choose Fry Reglet Fry Reglet offers five different reglets in a variety of metal substrates. Each reglet is engineered to work in conjunction with Fry Reglet flashing to provide the best solution for your application. Fry Reglet also offers precoated flashings and reglets in factory-applied Kynar 500/Hylar 5000 finishes or factory applied powder paint in standard Fry Reglet colors, providing years of worryfree performance, and eliminating the need for field painting. ST STUCCO REGLET Made especially for stucco applications, the reglet is put in place over 3/4 baseboard prior to lathing, and the SpringLok flashing is locked into place after the roofing paper is applied. Then stucco is applied over the top. This system requires a backing (nailer) with sufficient depth to support the reglet and provide tension to create the proper fit. Galvanized steel - 24 ga. Galvanized steel - Factory applied Kynar 500/Hylar 500 finish or factory applied powder paint in standard Fry Reglet colors 7/8 STX STUCCO REGLET STX reglet is specifically engineered for stucco over block conditions, and designed to accept SpringLok flashing and other flexible flashing. A V projection allows stucco to be applied directly over the reglet. The efficient design of the STX reglet eliminates the need for a backing (nailer). Galvanized steel - 24 ga. Galvanized steel - Factory applied Kynar 500/Hylar 500 finish or factory applied powder paint in standard Fry Reglet colors 7/8 1 3/4 3 1 /2 ST REGLET STX REGLET

Complete Thinking Fry Reglet offers a total solution for commercial roof flashing applications. Our pre-engineered and pre-fabricated accessories and corners that make even the hardest part of the job that much easier and with better results. Fry Reglet, complete solution and total support always. ACCESSORIES PREFABRICATED REGLET CORNERS APPLICATION Factory manufactured mitered and sealed corners help reduce installation time. Corners are available for reglet products shown as well as STX stucco. INSTALLATION See separate sheets with individual reglet installation instructions. CONCRETE REGLET ACCESSORIES CONNECTOR CLIPS Clips provide positive alignment at joints and prevent concrete leakage during pouring. INSTALLATION STAPLES Staples secure reglet to forms prior to pouring concrete. VINYLOK RETAINER APPLICATION Polyvinyl chloride Vinylok flashing retainer fills many too small spaces between parapet and cant strip where standard flashings do not fit. For use with ST stucco, STX stucco, MA masonry and SM surface mounted reglet. Not for CO concrete. INSTALLATION Flexible flashing is installed to contact reglet. Vinylok retainer is pressed into area with tail flat against flashing. COLOR REGLETS & OPTIONS: Fry Reglet Standard factory-applied powder paint finishes in all standard colors. Special order precoated flashings and reglets in factory-applied Kynar 500/Hylar 5000 finishes. Call Fry Reglet for colors and delivery information and minimum quantities. SURFACE MOUNTED REGLET TYPICAL INSIDE CORNER STUCCO REGLET TYPICAL INSIDE CORNER MASONRY REGLET TYPICAL CONCRETE REGLET OUTSIDE CORNER TYPICAL OUTSIDE CORNER TYPICAL OUTSIDE CORNER SEALANT DRIVE PIN & WASHER SURFACE MOUNTED REGLET Vinylok TYPICAL INSIDE CORNER Surface Mounted Reglet VINYLOK FLEXIBLE 1 1/8 Contact Fry Reglet for product details, installation instructions and complete wind load test data. Drawings are not to scale. Available Nationwide 800.237.9773 Fax: 800.200.4379 www.fryreglet.com INTERIOR SURFACE SYSTEMS COLUMN COVERS REVEALS, MOLDINGS & TRIM ROOF INTERIOR GLAZING SYSTEMS SPECIALTY PRODUCTS