LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34



Similar documents
OLI. Oil level indicator

INSTRUCTION MANUAL Oil level indicator with pointer

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Cable Plug acc. to DIN EN , Form A

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

HERZ-Thermal Actuators

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

Thermometer in stainless steel with capillary and switch contacts

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

ATL Fuel Level Sender Probes

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

Mounting Instructions. Torque Transducer. A en

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Vacuum Gate Valve DN 100 and DN 150

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Radiant Temperature Sensor TY7321

Proportional pressure regulators VPPE

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag DESCRIPTION pag TECHNICAL SPECIFICATIONS pag INSTALLATION pag.

IntelliChlor Flow-Temperature Switch Replacement Kit Installation Guide

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

Turbine Flow Sensor Series VTR

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Cross-beam scanning system to detect slim objects. 100 mm in

3/2-way Solenoid Valve, direct-acting, NC or NO

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements

Rotary actuators Rotary wing drives Series RAK. Brochure

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Guide rail bracket (for adjustable heads)

STANDARD MICRO-D CONNECTORS

Speed Control Relays SX2

Series 8146/5-V37 and Series 8150/5-V37

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

H45 LED - Direct and indirect pendant

SEISMIC VELOCITY TRANSDUCER T1-40

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

! WARNING. Before using product, read and understand instructions.

Toroidal Conductivity Sensor

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

T-Series Precision Linear Actuators Installation and Service Manual DW110353GB EDITION 5.

Linear Luminaire with LED Series EXLUX 6402/2

T R A N S F O R M E R A C C E S S O R I E S SAM THERMOMETERS

INSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

Profile rail guides LLR

Displacement encoders

Series 6000 Torque measured metal bellow coupling

LUCCI AIRFUSION QUEST II CEILING FAN

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Type 3353 Angle Seat Valve

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

Adjustment functions for both span and shift have been incorporated

DryLin ZLW Belt Drive

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

How To Read A Pipe From A Sensor

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Flow switches Series AD/VH

Givare NC-SRS 280 och 880

Solid-State Timer H3G

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

MEMBRANE VACUUM MINI PUMPS

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Machine Safety Switches

D.C. Motors. Products and specifications subject to change without notice.

Self-aligning ball bearings

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

3 Port Solenoid Valve

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

K17.12 Door closers K17. Doors

Tool Turrets and Tool Discs

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Air damper actuators

Waterproof Connectors for Outdoor Use

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Compact pressure switch Flameproof enclosure Ex d Model PCA

Operating Instructions. Room temperature controller

SOLENOID VALVES AND PNEUMATIC VALVES

Electro-pneumatic control valves

How To Use A Flowmeter

3-Component Measuring System

Explosion proof enclosures

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Transcription:

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

2 LEVEL GAUGES WITH MAGNETIC JOINT SIZE Ø 140/220/340

58 58 TYPE LA TYPE LA 14 30 S 22 33 TYPE LA 22-34 NO. HOLES Ø D2 76 O-RING CENTRE OF THE CONSERVATOR 120 Ø DC = DIAMETER OF THE CONSERVATOR Ø DC R= VARIABLE LENGHT fig. 1 R = (DC/2-10) x 1.15 S = (DC/2-40) x 0.577 TYPE LB TYPE LB 14 30 22 33 TYPE LB 22-34 NO. HOLES Ø D2 90 O-RING R= VARIABLE LENGHT Ø DC = DIAMETER OF THE CONSERVATOR Ø DC Ø D1 Ø D L L 56.5 24 Ø 60 Ø D1 Ø D Ø 58 PG 16 56.5 24 120 Ø 60 Ø DC Ø 58 PG 16 fig. 2 R = (DC/2-10) x 1.15 TYPE OF GAUGE Ø D Ø D1 Ø D2 NO. HOLES L O.RING TYPE WEIGHT kg R STANDARD LA14 140 125 7 6 245 O.R. 186 (6362) 1.40 max. 370 LA22 220 190 11.5 8 325 O.R. 221 2.30 max. 550 LA34 340 305 18 8 445 O.R. 248 (81000) 6.00 max. 710 LB14 140 125 7 6 245 O.R. 186 (6362) 1.70 max. 370 LB22 220 190 11.5 8 325 O.R. 221 3.60 max. 550 LB34 340 305 18 8 445 O.R. 248 (81000) 6.30 max. 710 DIMENSIONS IN MILLIMETERS 3

LEVEL GAUGES WITH MAGNETIC JOINT The level gauges with a magnetic joint are composed of a sturdy watertight body of aluminium alloy painted against corrosion. The movement of the float rod and the gauge disk takes place by means of magnetic coupling through an angle of 120. In this way, for every variation in the level of the liquid there is a corresponding rotation of the magnet with consequent variation of the indication on the dial of the gauge. The gauge disk is coloured white and red. The system is closed with a screen-printed polycarbonate disk with reference marks corresponding to the levels that the oil should reach at the following temperatures in degrees Centigrade: -20 C, +20 C, +85 C. Note: special dials may be made on request. READING THE INDICATIONS OF THE VARIOUS LIQUID LEVELS - Minimum level: when the dial shows all red. - Maximum level: when the dial shows all white. - Intermediate indications between MAX and MIN: the dial shows part white and part red. Remember that the amount of red shown indicates, in proportion, the part of the conservator left without liquid. FLOAT MOVEMENT This may be in the radial direction of the conservator (type LA ) or in the axial direction (type LB ), as shown in the drawing (Fig. 1 and 2). FLOAT ROD This is completely threaded. If the length is not specified (distance R in the drawing, fig. 1 and 2), the standard size indicated on the table is supplied. ELECTRIC INDICATION These level gauges are fitted with microswitches for indicating the minimum and maximum oil level. ELECTRIC CHARACTERISTICS - Power supply: 24 to 220 V a.c. or d.c. - Interruption power: 3 A 125/250 V ac (resistive) 0.5 A 125 V dc for inductive load L/R = 40 ms 0.25 A 250 V dc for inductive load L/R = 40 ms INDICATING INTERVENTION The electric microswitches intervene with an advance angle of 5 with respect to the indications of the minimum or maximum oil level in the conservator. When there is a double contact on MIN and/or MAX, the second contact intervenes about 5 after the first contact. After installation of the gauges it is possible to check the correct operation of the microswitches and, in general, good operation of all the internal parts of the gauge by proceeding as follows: - Remove the cap situated in the centre of the dial on the front of the level gauge, unscrewing it in an anticlockwise direction. - Insert a screwdriver in the slot provided and turn the gauge disk until the electric circuit connected to it switches on or off. - Close the cap again, being particularly careful to position the O-ring (O.R.) correctly under the cap and to screw the cap on quite firmly. RESISTANCE TO VIBRATIONS ON THE ELECTRIC CONTACTS Tests have been carried out according to the procedures illustrated below in graph (10 cycles), with an amplitude of oscillation of 2 mm and in normal working conditions. No contacts gave any sign of closing or opening. NOTES External nuts and bolts made of stainless steel. External painting in grey RAL 7001. Degree of protection: IP 54. Working temperature. All the level gauges are suitable for working with: - Oil temperature between: -25 C and +120 C - Environment temperature between: -25 C and +60 C 4

INDICATIONS FOR ASSEMBLY The level gauges which have float movement in the radial direction of the container (type LA ) must be fitted offset with respect to the horizontal axis of the conservator (distance S fig. 1) so as to have an exact indication of the minimum and maximum oil level. Those with movement in the axial direction (type LB ) must be fitted in the centre of the conservator. The measurements of the movements (distance S ) and the length of the rod (distance R ) are obtained from the formulae given under fig. 1 and 2. It is good practice to check operation of the gauge after having fitted it on the conservator.for further and more detailed information, see the technical information card supplied. TESTS AND INSPECTIONS The level gauges are subjected to insulation test towards earth as follows: 2.5 kv AC 50/60 Hz for 72 seconds. The bodies of the level gauges, after having passed the dimensional inspection and without their internal parts, are tested for watertightness so as to eliminate those that have leaks. Final testing is carried out when the level gauge is completely assembled. The sensitivity of all the signalling movements and the accuracy of their assembly are scrupulously checked. IDENTIFICATION MARKS The mark that completely identifies the type of level gauge is composed of a series of letters and numbers according to the following pattern: 1 (letter) 2 (letter) 3 & 4 (cifra) 5 (lettera 6 (lettera) 7 (lettera) L A B 14 22 34 K Y X W O S N S Level gauge Movement of the radial float (fig. 1) (letter) Movement of the axial float (fig. 2) Size of the level gauge = Ø 140 mm Size of the level gauge = Ø 220 mm Size of the level gauge = Ø 340 mm Wiring diagram with 1 contact on min. Wiring diagram with 2 contacts on min. Wiring diagram with 1 contact on min. + 1 contact on max. Wiring diagram with 2 contacts on min + 2 contacts on max. Ordinary paint Paint for corrosive environments COMEM standard level gauge Specific level gauge for customer Example : LA14XON Level gauge with radial movement, diameter 140 mm, wiring diagram with 1 contact on minimum and 1 contact on maximum, painted for normal environments and with standard COMEM dial and rod length. WIRING DIAGRAMS DIAGRAM TYPE K DIAGRAM TYPE Y 1 CONTACT ON MINIMUM LEVEL 2 CONTACTS ON MINIMUM LEVEL DIAGRAM TYPE X DIAGRAM TYPE W 1 CONTACT ON MIN. LEVEL + 1 CONTACT ON MAX. LEVEL 2 CONTACTS ON MIN. LEVEL + 2 CONTACTS ON MAX. LEVEL 5

comem - S.p.A Strada Statale 11, km 338 36054 MONTEBELLO VIC.NO (VI) ITALY Tel. 0444 449 311 Fax 0444 449 352-440 359 Internet http://www.comem.com e-mail: comem@comem.com edizione 11/01 - Edigraf - 5m cod. 54100L2000