308 / 616 / 824 / 832 ULTRA / COMPACT PROGRAMMING MANUAL



Similar documents
Electronic push button instruments approved by DOT should be used on the CRYSTAL EPABX. You may use either pulse or DTMF phone on any extension.

Quick Reference Guide For Partner ACS R5 System Programming

Aristel. DV Series Key Phone Operation Manual 1 GENERAL DESCRIPTION KEY PHONE SPECIFICATION KEY PHONE LAYOUT... 1

Karel MS48. Telephone System. Programming Guide. Edition 3.2

Business Communications Manager Telephone Feature Card

How To Use A Key Phone (Blackberry) With A Cell Phone (Cell Phone) With An Iphone) With The Blackberry (Blackburn) With Blackberry) And Blackberry Phone (White) With Cell Phone) (Black

KX-T7735 KX-T7730 KX-T7720 KX-T7750

Hicom 300 optiset E standard optiset E advance / advance plus optiset E memory

Single Line Telephone User Guide

Panasonic Digital Business System Programming Table Master Sheets

Model PBX 308 Plus System Administration Guide

Welcome to BT Inspiration An introduction to your new BT Inspiration System and its documentation 6 Featurephone basics 7

USER MAUNAL Aristel Group CONTENT

Get Started User Guide

System Administration Guide. Model KS 832. Expandable up to 1664

TABLE OF CONTENTS SYSTEM ADMINISTRATION AND SPECIAL FEATURES GUIDE. idcs 16 DIGITAL COMMUNICATIONS SYSTEM. March 2005 ABOUT THIS BOOK...

Table of Contents. Mitel 3000 Getting Started Guide

Telephone Features User Guide. BCM Business Communications Manager

Norstar ICS Telephone Feature Guide

Analogue Telephone User Guide

IP Office Basic Edition IP Office Basic Edition - Quick Mode Phone Based Administration

How To Use A Cell Phone On A Cell (Cell Phone) On A Landline Phone On An Iphone Or Ipad Or Ipa (Cellphone)

Advanced Hybrid System KX-TES824

Advanced Hybrid Systems KX-TEA308 KX-TES824

Automated Telephone System

IP Office Essential Edition IP Office Essential Edition - Quick Version Phone Based Administration

Model PBX 416 Plus System Administration Guide

Standard Telephone User Guide

Release Date Version Supersedes Description. June 2006 Initial Release Initial Release

Quick reference guide Line small business system with caller ID/ call waiting and speakerphone

32 Switchboard User Guide

Norstar ICS Telephone Feature Guide

PRIMUS HOSTED PBX CALLING FEATURES REFERENCE GUIDE

Aristel SLT70 OPERATION MANUAL 2.1 SLT70 LAYOUT CHECK LIST INSTALLATION NOTE...3

eircom advantage IP Professional phone user guide

Evolio AC Series Model: 208AC 308AC 416AC 432AC

Call Forwarding No Answer Interrogation 1. Lift telephone handset. Press the assigned code (ex. *61*).

STANDARD TELEPHONE USER GUIDE

End-User UC PORTAL USER GUIDE

Enterprise Edge Feature Programming Telephone Guide

Automatic Call Distribution (ACD)

Advanced Hybrid System KX-TES824 KX-TEM824

Norstar Programming Feature Codes

Meridian Telephone Userguide

CCI Hosted Voice Services Special Calling Features Quick Reference Guide

PT Programming Manual KX-TDA50/KX-TDA100 KX-TDA200/KX-TDA600. Hybrid IP-PBX. Model No.

Hosted Business Voice END USER PORTAL GUIDE

Sprint k3 Digital Phone System

How To Connect A Cell Phone To A Cell Network

Personal Speed Dial Numbers

The way to use Software for PBX is use to Program system via Computer mode.

Model PBX 416+ Programming & User Guide

Quick reference guide Line small business system with speakerphone

Business Communications Manager ATA 2 User Guide

Quick Reference Book. Cisco 7940 & 7960 Series IP Phones. Business Feature Set T6000 Release 6.0 SCCP Protocol

AT&T. MG9150J Issue 1 October PARTNER Plus, PARTNER II Communications System Programming Quick Reference

User Guide for the Orchid Key Phones KP416 & KP832

3904 USER GUIDE. Stores one phone number per key for quick dial.

IP PBX system USER MANUAL. ver

# $ %&' ( $" )% %! $" )$) %! &%& $'('!

Flash Calls. Feature Access Code Calls

DKT / IPT Telephone Quick Reference Guide STRATA. Business Telephones Helping You Communicate Better CIX/CTX

" (877)MY T4 TEL " " " " " " " (877)

SYSTEM ADMINISTRATION AND SPECIAL FEATURES GUIDE

Cisco 7941 / 7961 IP Phone User Guide

SYSTEM ADMINISTRATION AND SPECIAL FEATURES GUIDE

NEC SV Multiline Telephone User Guide All Digital and IP Phones w/um-8000 Voice Mail

one Managing your PBX Administrator ACCESSING YOUR PBX ACCOUNT CHECKING ACCOUNT ACTIVITY

di git al u se r guide

PT Programming Manual KX-TDA50/KX-TDA100 KX-TDA200/KX-TDA600

Quick reference guide Line small business system with digital answering system and caller ID/call waiting

Model PBX308. System Administrators Guide

ultiline Telephone y User Guide NEC LEVEL II

DCS SYSTEM ADMINISTRATION AND SPECIAL FEATURES GUIDE. Page 1 DIGITAL COMMUNICATION SYSTEM

Clear Choice Communications. Digital Voice Services User Guide

AV Series Key Telephone System

Dialog 4220 Lite/Dialog 4222 Office

Model PBX816ex. Programming & User Guide

How To Call The State Government From A Cell Phone

Agorà 2. Mod Ref.1372/312. ScaiTerm2Net Application Software

Office Voice User Guide. User Guide

AUTOMATIC CALL DISTRIBUTION (ACD) INSTALLATION MANUAL

BUSINESS TELEPHONE SYSTEMS. P.O. Box 1369 Campbell, California (408) 866-BIAX 75 Dillon Avenue Campbell, California

Four-Line Intercom Speakerphone 944

Personal Speed Dial Numbers

Model PBX 308 System Administration Guide

MS SERIES TELEPHONE EXCHANGES MS26C MS38S MS38-ISDN MS48 MS48S MS48-ISDN MS128 MS224 USER S GUIDE

INTRODUCING VERIZON S INTEGRATED COMMUNICATIONS PACKAGE

ACD Manual. Version 3.1 for SV8100 R8

AT&T. PARTNER Plus/PARTNER II. Quick Reference for Use with MLS-Series Telephones. Communications System

Advanced Hybrid System. User Manual. Model No. KX-TA624. Please read this manual before using the Advanced Hybrid System.

STANDARD TELEPHONE USER GUIDE

HPBX User Guide. Version V ISIT W IGHTMAN. CA

How To Use A Telephone In European Europe

User Guide Dialog 3210, 3211 and 3212 SYSTEM TELEPHONES

Digital Voice Services User Guide

2 Session buttons. 1 Phone Screen

Model PBX 308 Plus System Administration Guide

TXI Telephony Product Book

Transcription:

308 / 616 / 824 / 832 ULTRA / COMPACT PROGRAMMING MANUAL S.No. Features Page No. 1. Programming Password 2 2. Programming Related to Trunk 2 3. To Assign Trunk Group 2 4. To Set Trunk Ringing Option 3 5. Fax Extension 4 6. Extension Status 5 7. Door Phone Ringing Pattern 5 8. Memory Dialing & Feeding 5 9. Global Memory Dialing (Bank 1) 6 9. Global Memory Dialing (Bank 2) 6 10. Caller ID Programming 7 11. Auto Redial 7 12. Auto Call Transfer (CLI Based Call Routing) 8 13. DID (Voice Guided DISA) 9 14. To Record Voice for DID 9 15. Printer Related Programming 9 16. Date & Time Setting 10 17. Auto Day Night Mode 11 18. Emergency Reporting 11 19. Remote Programming 11 20. Flash Time Setting of Extension 12 21. Call Disconnection 12 22. Forced Release of Ext/Trk 12 23. Call Privacy 12 24. Barge in With Tone 12 25. Barge in Without Tone 12 26. Do Not Disturb 12 27. Paging Rights 13 28. DOSA Allow 13 29. NV RAM Programming (Create Master Copy for Programming Recovery) 13 30. Change Programming Password 13 31. Change Night Code 13 32. Pulse Rate Setting 14 33. Pulse Call Format 14 34. Hotel Features 14 35. Change Number 14 35. Check In 14 37. Check Out 14 38. Guest Service Group Setting 15 39. Programming For the Guest Group 15 40. Change Operator Extension 15 41. Floor Service 15 42. To Make Floor Service Extension 15 43. Call Maturity Timing 16 SYSTEM FEATURE MAY VARY FROM MODEL TO MODEL

Programming of COMPACT/ULTRA SERIES PROGRAMMING PASSWORD Dial 64 + password (Initial Password is 1234) If password is right then confirmation tone else reject tone Now you can dial codes as given in Programming manual below Note : Programming can done with EXT 20 & 21 only. Press k after every Programming to accept the code and proceed for further programming EXTENSION NUMBERS 20 to 27 for 308 MODEL 20 to 35 for 616 MODEL 20 to 51 for 832 MODEL TRUNK NUMBERS 71, 72 & 73 for 308 MODEL 71 to 76 for 616 MODEL 71 to 78 for 832 MODEL PROGRAMMING RELATED TO TRUNK : To set trunk category 94 + TRUNK + 0 / 1 / 2 0 : DECADIC (PULSE) 1 : TONE (DTMF) 2 : Incoming trunk / blocking Trunk group 0/9 (See next page for 616 to 832, 1264) 93 + TRUNK + 0 / 1 TO ASSIGN TRUNK GROUP : 0 : for trunk group 0 1 : for trunk group 9 TRUNK GROUP ZERO (ACCESS CODE"0") For 308 91 + EXT NO + 0 / 1 0 : disallow access to 0 trunk group 1 : allow access to 0 trunk group 2

TRUNK GROUP ONE (ACCESS CODE"9") For 308 92 + EXT + 0/1 Grouping For 616/824/832/1264 0 : disallow access to 9 trunk group off 1 : allow access to 9 trunk group on To make Group : Pw + 93 + Group No. + Trk1----Trk8 (Repeat same trunk if less than 8 trunks) Group no. : 1 to 6 for 616 1 to 8 for 832 0 is Default group 9 is disallow To Assign Group : Pw + 91 + Ext. No. + 0/1 + Group no. 0 = 0 Dial (access code 0) 1 = 9 Dial (access code 9) Note : One Extension can be assigned max. two groups For Example : You have 4 trunks 71, 72, 73, 74 You want 3 trunks in 0 and 74 trunks in 9 Then the Programme will be Pw + 93 + 1 + 71+72+73+73+73+73 For 0 Group Pw + 93 + 2 + 74+74+74+74+74+74 For 9 Group Now allow group as follows Pw + 91 + Ext. No. + 0 + 1 for allowing 0 dial group Pw + 91 + Ext. No. + 1 + 2 for allowing 9 dial group Disallow group Pw + 91 + Ext. No. + 0 + 9 0 group disallow Pw + 91 + Ext. No. + 1 + 9 9 group disallow Note : Please do not forget to allow 0 group, otherwise 74 No. Trk also accessed by 0 dialing. TO SET TRUNK RINGING OPTION Self Service Group 95 + Trunk + EXT1 + EXT2 + EXT3 + EXT4 3

Self Service Group for Night 54 + Trunk + EXT1 + EXT2 + EXT3 + EXT4 Common Service Group 97 + EXT1 + EXT2 + EXT3 + EXT4 Combination Options for trunks 98 + trunk no + XY X : for day Y : for night 1 Round robin ring on self service group. 2 Simultaneous ring on common service group. 3 Fax Trunk else simultaneous ring at self service group. 4 Simultaneous ring on self service group. 5 Left For Future Programming addition. 6 DID else simultaneous ring at self service group. 7 DID else simultaneous ring at common service group. 8 DID else round robin hunting at self service group. 9 Fax Trunk else simultaneous ring at common service group. 0 Fax Trunk else round robin hunting at self service. FAX EXTENSION (Available in Ultra Series) 738+EXT No. on which fax has to be connected FLEXIBLE ROUND ROBIN RINGS Pw + 43 + Ext No. + 2/3/4/5 2 rings in round robin 3 rings in round robin 4 rings in round robin 5 rings in round robin RING BACK TONE MODULATION (available in 616/824/832 only) Pw + 39 + 0 Modulated ring back tone + 1 Plain ring back tone 4

EXTENSION STATUS / CLASS OF SERVICE 80 + EXT NO + option(xy) X : for day mode Y : for night mode 1 : ALL OFF 2 : LOCAL as per denied table 3 : LOCAL ON Including 95 4 : STD ON 5 : ALL ON Denied table : 45 + 0-9 + digit to be denied + k (Max. 6 digits) e.g. : You want to denied 95, 94 and 98 then programme will be 45 + 0 + 95k 45 + 1 + 94k 45 + 2 + 98k DOOR PHONE RINGING PATTERN (Available in Ultra Series) 57 + Ext1 + Ext2 + Ext3 + Ext4 (Door can be picked by dialing #) Pw + 440k Door phone converted to Extn. (only in Ultra 309) Pw + 441k Door phone Pw + 442k Round robin ring Pw + 443k Simultaneous ring for door phone Door Lock Rights (Available in Ultra Series) 67 + Ext. No. + 0 / 1 0 Disallow 1 Allow MEMORY DIALING & FEEDING Personal Memory Dialing To store personal number 110 + (800-809) + trunk number or group number + telephone number Group number may be 0 or 9 Trunk number may be 71, 72, 73 If group number is 0 means trunk will be selected from trunk group 0. If group number is 9 means trunk will be selected from trunk group 1. If 71, 72, 73 means number will be dial on that trunk only. Telephone number should not exceed 16 digit. Dial 800 to 809 for your personal number 5

Once you have dial the number from bank you can redial this number by k or 12 # System will dial number itself # If you get reject tone : Then it means i) Your dialing status do not match with number ii) Trunk category may be ONE WAY type iii) Free trunk not found iv) No number is stored in bank GLOBAL MEMORY DIALING [BANK 1 (FREE BANK) FOR ANY CLASS OF SERVICE] Number can be stored in bank 1 by extension 20, 21. Numbers stored in bank 1 can be dial by any extension without caring its class of service. Dial 810 to 854 for your global bank 1 number system will dial number itself if you get reject tone : then it means i) trunk category may be ONE WAY type ii) free trunk not found iii) no number is stored in bank To set Global Bank 1 : 68 + 10-54 + TRUNK + Telephone Number 68 + 20-59 + TRUNK + Telephone Number (in 1264 Model) TRUNK : Trunk access code 0, 9, 71, 72, 73 Telephone Number : maximum 16 digits Note : To clear Bank 1 6931 GLOBAL MEMORY DIALING (BANK 2 AS PER CLASS OF SERVICE) Number can be stored in bank 2 by extension 20, 21. Dial 855 to 899 for your global bank 2 numbers system will dial number itself if you get reject tone : then it means i) your dialing status do not match with number ii) trunk category may be ONE WAY type iii) iv) free trunk not found no number is stored in bank 6

To set global Bank 2 : 68 + 55-99 + TRUNK + Telephone Number 68 + 60-99 + TRUNK + Telephone Number (in 1264 Model) TRUNK : Trunk access code 0, 9, 71, 72, 73 Telephone Number : Maximum 16 digits Note : To clear bank 6932 CALLER ID PROGRAMMING (Require Optional CLI Card) Caller Line ID In case of call transfer last two digits will be extension number. For CLI maximum digits to be send are 16. To use CLI facility : 64 + 6 + trunk no // CLI ON / AUTO CALL TRANSFER_ON 64 + 7 + trunk no // CLI OFF / AUTO CALL TRANSFER_OFF For 1264 Model 64 + 7 + trunk no // CLI ON / AUTO CALL TRANSFER_ON 64 + 6 + trunk no // CLI OFF / AUTO CALL TRANSFER_OFF allow CLI to EXT on which CALLER ID Instrument is connected 91 + EXT NO + 2/3 2 : disallow CLI 3 : allow CLI 91 + EXT No + 8 Intercom CLI 2 DIGIT 9 Intercom CLI 7 DIGITS (Default 7 digits) (Some Instruments require minimum of seven digits in CLI so Ext 21 will be shown as 0000021 but in case of transferring the CLI Only 2 digit EXT. no. will be added to the transferred ext.) AUTO REDIAL (Available in ULTRA 309, 616, 832) To set auto redial - dial 60 a) if assurance tone means auto redial has been set and after 2 minute (whatever time gap is set) system will do auto redial. b) If reject tone Auto redial is not open for whole system. Auto redial on that extension is not allowed Extension has not dialed numbers on trunk 7

To use AUTO REDIAL facility : Open auto redial facility 64 + 5 / 4 5 : Auto redial ON 4 : Auto redial OFF Set maximum numbers of auto redial attempts setting 58 + 99 (01 to 99) (default number of attempts is 5 ) Set auto redial time gap setting 59 + MM + SS (1 to 5 MINUTE ) ( default time gap is 2 minute ) Allow Auto Redial to Extensions 91 + EXT NO. + 4/5 4 : disallow Auto redial 5 : allow Auto redial Tune Auto Redial Filter Dial 6960 (you will get trunk dial tone, adjust trimmer on CPU for glowing LED on dial tone not blinking Cancel the auto redial - Dial 61 Assurance tone AUTO CALL TRANSFER (CLI BASED CALL ROUTING) (Require optional CLI Card) The incoming call will transfer to extension if number stored in auto call transfer buffer will match. If number do not match than normal landing of trunk. This facility can be used only with CLI facility on trunk line. Programming related to AUTO CALL TRANSFER : To store number (Total 20 numbers can be stored) 72 + ext no. + STD/ISD/TELEPHONE NUMBER Clear auto transfer buffer 730 ( all numbers stored in buffer will be deleted ) Clear auto transfer buffer 731 + STD/ISD/TELEPHONE NO. (to delete particular number k) To take print of auto transfer buffer Dial 8488 8

DID (VOICE GUIDED DISA) : (Available in ULTRA Series) You have to allow DID on trunk by : 98 + trunk no + XY (option for trunk) Trunk no : 71/72/73 to 78 for higher models X : for day Y : for night 6 : DID else simultaneous ring at self service group 7 : DID else simultaneous ring at common service group 8 : DID else round robin hunting at self service group TO RECORD VOICE FOR DID 69 + 85 : voice recording for first message (Day Mode) 86 : to listen first recorded message 87 : voice recording for second message (Night Mode) 88 : to listen second recorded message PRINTER RELATED PROGRAMMING : (Available in ULTRA Series) For online printing setting 648 For offline printing setting 649 Open Incoming Call Login facility 732 disable incoming call login 733 enable incoming call login Note : incoming calls will login only if CLI on trunk is enable. Open Missed Call Login facility 734 disable missed call login 735 enable missed call login Note : Miss calls will login only if CLI on trunk is enable. Printer port Diversion 736 for hyper terminal i.e. all data to serial port RS 232 type 737 for parallel port (will support parallel printer Dot Matrix) 9

Parameters for serial ports are as under Bits per Second 19200 for 308 & 1264 and 9600 for 616, 824, 832 Data Bits 8 Parity None Stop Bit 1 Flow Control None Particular ext/trunk printing (available in 309 to 832) 82 + 0/1 + ext/trunk no. + ext no./trunk no. 0 : STD/ISD calls 1 : All calls (on computer type p82 + 0/1 + start Ext. + End Ext. + ) Particular date printing (available in 309 to 832) Pw + 83 + 0/1 + Start ext + End ext + date (DDMMYY) + (on computer type p83 + 0/1 + Start Ext. + End Ext. + date + enter) Particular ext/trunk printing (available in 1264) 82 + 0/1 + Ext/Trk1 + Ext/Trk2 + Ext/Trk3 + Ext/Trk4 + 0 : STD/ISD calls 1 : All calls (on computer type p82 + 0/1 + start Ext. + End Ext. + ) Particular date printing (available in 1264) Pw + 83 + 0/1 + (DDMMYY) + Ext1 + Ext2 + Ext3 + Ext4 + (Ext - minimum four different members) Clear Printer Buffer 69 + 69 : clear the printer buffer Printing format 8411 : buffer printing (on computer type p8411) 8422 : stop printing 8455 : resume printing 8466 : incoming call printing (on computer type p8466) 8477 : missed call printing (on computer type p8477) 8488 : auto call transfer printout (on computer type p8488) 8489 : Printout Global bank 1 (on computer type p8489) 8490 : Printout Global bank 2 (on computer type p8490) DATE & TIME SETTING 60 + HH + MM Set time in 24 Hrs Format 61 + DD + MM + YY Set Date DD day from 01 to 31 MM Month from 01 to 12 YY Year last two digits 10

AUTO DAY / NIGHT MODE You can keep your system in either Auto or manual day/night mode For auto mode 641 For manual mode 640 Set timings for auto day/night mode 62 + w + HHm + MMm + HHe + Mme HHm morning start hours MMm morning start minutes HHe evening start hours Mme evening start minutes w is the week day 1 to 7 Sunday = 1, Saturday = 7 to set manually night mode dial 112 + nite code + 0 to set manually day mode dial 112 + nite code + 1 EMERGENCY REPORTING To allow this facility to extension 87 + EXT NO. + 0/1 Emergency reporting group 0 : emergency reporting disallow 1 : emergency reporting allow 70 +EX1 + EX2 + EX3 + EX4 REMOTE PROGRAMMING Establish conversation with trunk Dial flash + 69 Trunk and ext. both will listen confirmation tone. Dial Password (default 1234) Now you can start Programming If Programming accepted then confirmation tone Else reject tone To disconnected dial # else you will disconnect after 15 seconds 11

FLASH TIME SETTING OF EXTENSION 71 + EXT + count count : 3 to 9 and 0 here each count stand for 100ms 0 means 1 sec. and 9 means 900 m.s. CALL DISCONNECTION INCOMING CALL To disconnect outgoing/incoming call after predefined time 91 + Ext. no. + 6/7 6 : disable this facility 7 : enable this facility CALL DISCONNECTION OUTGOING CALL 90 + Ext. + 6/7 6 = Disable 7 = Enable CALL DISCONNECTION DURATION 56 + X X = 1 to 9 Minutes FORCED RELEASE OF EXTENSION/TRUNK 86 + Ext. no. + 4/5 4 : Disallow 5 : Allow CALL PRIVACY 67 + EXT. No. + 2/3 2 : privacy off 3 : privacy on BARGE IN WITH TONE 67 + Ext. no. + 4/5 4 : barge in tone off 5 : barge in tone on BARGE IN WITHOUT TONE 90 + Ext. no. + 0/1 0 : off 1 : on DO NOT DISTURB 85 + Ext. no. + 0/1 0 : Disallow 1 : Allow DO NOT DISTURB OVERRIDE 85 + Ext. no. + 0/1 0 : Disallow 1 : Allow 12

PAGING RIGHTS (Available in Ultra Series) 87 + Ext. no. + 2/3 2 : Disallow 3 : allow DOSA ALLOW (Available in Ultra Series) 86 = EXT. + 2/3 2 : Disallow Central Ringer (Available in Ultra Series) 642 Off 643 On Time for Central Ringer 65 + 1 to 4 + HH MM (total four alarms can be feeded) Central Ringer Duration 55 + SS SS=05 to 60 seconds To reset the full system 69+49 (after this command the full system reset to initial state) To reset personal password 67 + Ext. + 9 (the ext. password will be default i.e. 777) To Create Master copy in NV RAM 69+58 To recover Master copy from NV RAM 69+59 CHANGE PROGRAMMING PASSWORD 99 + New Pw + New Pw CHANGE NIGHT CODE 88 + ZZ Nite code become ZZ default 99 Extension pickup Group : Pw + 89 + Ext. No. + Group No : (0 to 9) Second Programming Ext : Pw + 52 + Ext. No. (Default is 20 & 21) Transfer Ring Pattern 37 + 0/1 0 : Double Ring 1 : Single Ring 13

Pulse rate setting including timing for local or 98 or STD/ISD (only in Ultra) 75 + 00 to 99 + Pulse + STD Code/Local Code Pulse - (3 Digit) STD Code - (Six digit max) For example you want local 120 sec., mobile calls 60 sec., WLL 90 seconds and Mumbai 16 seconds then the programme will be 75 + 00 + 120 + 2k Local starting from digit 2 75 + 01 + 060 + 98k Mobile starting from digit 98 75 + 02 + 090 + 3k WLL starting from digit 3 75 + 03 + 090 + 5k WLL starting from digit 5 75 + 04 + 016 + 022k Mumbai 16 sec. pulse Similarly you can feed pulse for 95 or 94 or any other STD/ISD code. Pulse Call Format 74 + X + PPP PPP in paisa (000-999) 1 : for local 2 : for 95 3 : for STD Hotel Features available in 616/832 Ultra Model (Require Software replacement) Change Number 51 + present number + new number If new number already exist then present number and that number will interchange. Check In Pw + 46 + Ext. No. + 1 Check Out Pw + 46 + Ext. No. + 0 After check out the call printout will come on printer. Room to Room Barring (for 1264 Model) Pw + 34 + Ext. No. +4/5 + 4 : Intercom to Intercom not allowed 5 : Intercom to Intercom allowed Guest Service Group Setting We can have three types of groups : Single guest group, Party guest group and Service group. Each extension can be classified under service group or guest. Guest group 0 : 14

This group can call only service group extns. They cannot call any other guest. Normally, rooms occupied by separate guests should put in this group. Guest Group 1 to Guest Group 8 : Suppose a group of guests arrives in a hotel and they occupy 4 rooms and these 4 rooms can be grouped in one group say group 1. Once this is done, ext. programmed in group can call each other. They can also call service group ext. but cannot call other guest groups ext. if programmed or even extns. in group 0. Eight such group can be defined Service group 9 All extensions belonging to hotel staff and management can be classified in this group. Any extension can be called from this group. Programming for guest group 49 + extension number + group number group number (0 to 9) Change Operator Extension 50 + extension number (only for 832 Model) 50 + 1 + Ext. No. for 1st operator (only for 1264 model) 50 + 2 + Ext. No. for 2nd operator (only for 1264 model) Default ext. is 100 and operator can be access by any ext. by just dialing 9. Floor Service In hotels, all the rooms on one floor have a service room for room boys. The guest are required to dial an ext. no. (we call it a floor service code) to call room boy, just dial 8. The calls will go to service ext. of that floor. To make floor 48 + extension number + floor number To make floor service extension 47 + floor number + extension number Call maturity timing 66 + time (05-50 sec.) Note : Please make sure when ever connecting Printer or computer to the EPABX system there should not be any voltage between the EPABX earth and the computer/printer earth otherwise damage may occur in any of the device. 15

NOTES : 16