TECHNICAL CHARACTERISTICS



Similar documents
PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

1 DESCRIPTION OF THE APPLIANCE

BIOHOUSING Seminar Success stories of biomass heating in small scale

INTEC Engineering GmbH Heating Solutions for the Marine Industry

HUB RADIATOR HYBRID. Multi-energy hybrid system to produce heating and DHW. Multi-energy hybrid system to produce heating, cooling and DHW

POLYCITY. Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace POLYCITY

Indirect fired heaters

Practical Examples of Heat Regenerative System at Steelmaking Works

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

The soot and scale problems

HIGH QUALITY COMPONENTS

Cooking at the Speed of light!

Laddomat Charging unit

KONRAD. Hybrid Fancoil Series

Wood Pellet Stove 101

Condensing Boiler Efficiency

Description of functions

REDFYRE CENTRAL-HEATING COOKER (OIL & GAS FIRED)

Boiler and Burner Cleaning and Servicing Specifications

COMMISSIONING OF HVAC SYSTEMS

Commercial Gas Furnace Upflow

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Decree of the Ministry of the Environment on fire safety of ventilation systems

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

RPV - RP - RA air handling units

Safety Storage Cabinets

A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project.

High-performance steam boiler and hot water boiler plants for industry

Exé page couverture Anglais.qxp 05/05/ :32 Page 1 T H E D U T Y O F Q U A L I T Y CAST IRON FIREBOXES

AUSTROFLAMM Pavilion 9, stand 21

High-efficient gas boiler CompactGas

Providing reliable energy-efficient boilers B O I L E R S

Boston, Venice, Kodiak. Enviro Wood Fireplace Inserts

Description of Thermal Oxidizers

BIOMASS BOILER. Servicing and Maintenance Years. No Renewable Products Installed, Maintained

ELECTRIC CENTRAL HEATING FLOW BOILER

Single-Phase AC Synchronous Generator

Biomass heating: a guide to small log and wood pellet systems

COMMERCIAL REPORT / STOCK CONDITION SURVEY. Sydenham Hill Estate Sydenham Hill London SE 23

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

High efficiency, cast-iron gas boiler

I. STEAM GENERATION, BOILER TYPES

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza (Spain) Tel.: Fax:

ENVIRONMENTAL HEALTH PROFESSIONAL PRACTICE VOL II CHAPTER III. HOUSES IN MULTIPLE OCCUPATION Space Standards

Summary. Oven Line. Rack ovens. Deck Oven

SHAIYO TRIPLE A GROUP. Hochiminh City, 16 September 2013

BB-18 Black Body High Vacuum System Technical Description

understanding medium frequency induction melting furnace and its components

flueless gas fires & stoves

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

We have been working in an ideal climate for thirty years.

Biomass Boiler House Best Practices. Irene Coyle & Fernando Preto CanmetENERGY

Spray Booth Guideline

SECTION 807 PUMP STATION REHABILITATION

New ways and prospects of stove heating

Nominal Life Expectancy for Building Components

Munchkin Heat Exchanger Maintenance

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Apartment and Communal Heating Solutions

How To Build A Swebo Biotherm

Integrated Solar Radiant Systems

ST Style Generator. Owners/Operators Manual

1. Input pot circumference: use a soft tape to measure the circumference of the pot at the widest point below the handles.

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

BorsodChem MCHZ, Czech Republic. 6,000 Nm 3 /h HTCR Topsøe Hydrogen Plant A Case Story: 18 Months from Engineering to Operation

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

556/586 NEW NEW. One step closer to the fire.

ALUMINUM. BestPractices Assessment Case Study. Alcoa North American Extrusions Implements Energy Use Assessments at Multiple Facilities.

COMBLOC The future of packaged multi-fuel fired steam boilers. Ultra Compact. High Performance

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

AE BIO SOLAR AE BIO SOLAR HYBRID PLANT SOLAR/BIOMASS ADESSO ENERGIA SRL HYBRID PLANT SOLAR/BIOMASS THE BEGINNING OF A NEW ENERGY PRESENTATION

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

L-ENZ The dryer for bulk solids

heat treatment equipment & accessories

Originators of the Flexible Water Tube design

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

TECHNICAL DESCRIPTION

Buderus. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. G315 G515 G615 Cast Iron Commercial Boilers.

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

presents Hydraulic Separation Beyond Primary / Secondary Piping

The Savannah Steel Series Wood Burning Stoves and Inserts

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Oil - kerosene burners

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Automatic Door Selection Guide

A new range of clean burning multifuel stoves

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

1300 MAXTRAK SPECIFICATION

Heat-Pipe Heat Exchanger

plumbing products guide

Fire Damage. To Help Prevent. a Guide

Efficiency on a large scale CFB Steam Boilers

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

to control the heat alongside the boiler to protect the more sensitive metal components against thermal, erosive and corrosive degradation

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

Transcription:

TECHNICAL CHARACTERISTICS The FACI boilers for the production of warm water up to + 95 C they are built with a auto drive structure in a sheet of special steel of strong thickness of high mechanical resistance with a large combustion chamber, a hatch with crawl space for the manual loading of large chunks of combustible and for periodic cleaning of the brazier. The heat exchanger of the boiler is built with pipes like the SS boiler immersed in water. The heat exchanger is subsequently connected to the openable smoke expansion chamber and can be inspected for periodic maintenance. The base of the boiler is a refractory motar covered steel plate for high temperatures and for an excellent combustion. At the centre of the base is a perforated cast iron grate that allows the passage of primary air and gives oxygen to the material during the combustion. All the FACI boilers are provided with a general electric panel for the control of the various functioning cycles. They are completely caulked with anti radiant material and totally covered with painted steel oven panels. They can be predisposed for the application of the gas or gas-oil burner. A particular attention is reserved to the finish of the boilers with the verification of all the components and testing the mechanical functioning in the respect of the CEE directives. There has been in the last years, a notable increase in the use of industrial and civil heating plants, working on scrap wood with auto feed, this increase is determined by the possibility to use the boilers with automated feeding systems and endowed with very reliable sensors allowing an automatic management of the plants with the constant control of the combustion values, and guaranteeing an operation in the respect of the laws.

BOILER ROOM AND PLANT SIZING Particular attention must be devoted to the sizing of the plant, keeping in mind that boilers unlike those to gas or gas-oil must, as far as possible, work continuously and without interruptions. Accordingly, the overloading of the boiler must be avoided in that it could have negative consequences on the same; in fact forced interruption of the combustion, owed to the brutal arrest of the flow of combustive air, produce greater smoke production inside the boiler and of the fireplace, in this way getting a lesser middle-seasonal output of the boiler with an useless increase of the functional costs. Another important aspect to be considered is the availability of space for the storage of the thermal plant combustible that has to be situated in the immediate proximities of the same plant. The boiler room has to be spacious and well ventilated. Besides the boiler, the thermal plant should be able to accommodate the inertial accumulator, the sanitary boiler, the digital panel and the whole hydraulic plant design. It is a good norm to leave a free space of at least 60cm around the boiler; altogether leave a surface of around 8-10 square meters. For the plants of 35kW, the norm foresees that they are endowed with an independent access door from the outside. For this type of plant it is necessary to deposit the thermal plant plans to the officers of the local fire brigade and to communicate to the institute for the safety of workers. The FACI wood chip boilers use automatically loaded virgin chipped wood of the dimension of a few centimetres. The combustible used can be of material from different origin, i.e. chopped pruning, wastes of chopped wood from sawmills, biomasses deriving from the wood culture activities (cut of the wood copse, thinning out, cuts of conversion, etc.). The wood chip plants other than for the civil residences are particularly suited for the heating of buildings of medium to large dimensions such as hotels, schools, condominiums, hospitals and shopping centres.

MOD. FSS from 7 to 100 CONE COLLECTOR WITH REAR SIDE HINGE MISURE D INGOMBRO Mod. FSS Pot. resa Pot. bruciata H2 A L G P B K F1 F2 7 70.000(81) 90.000(104) 2.350 700 1. 930 10 100.000(115) 128.000(148) 2.450 830 1. 1.100 1.450 220 13 130.000(151) 168.000(195) 2.610 830 1. 1. 1.550 220 16 160.000(186) 204.000(237) 2.810 830 1. 1.460 1.900 220 20.000(232) 264.000(306) 3.550 1.000 1.500 1. 1.850 30 300.000(348) 360.000(418) 4.150 1.000 1.500 2.000 2.450 40.000(465) 480.000(558) 3.950 1. 1.500 1.780 2.330 50 500.000(581) 600.000(698) 4. 1. 1.500 2.100 2.650 60 600.000(598) 720.000(837) 4. 1.500 2.100 2.190 2.890 450 70 700.000(814) 840.000(977) 4.450 1.500 2.100 2.390 3.090 450 100 1.000.000(1.163) 1..000(1.395) 1.000 4.450 1.500 2.100 2.390 3.090 500 The descriptions and illustrations of the FACI production intends you furnish to simple indicative title. The Firm reserves the right to bring possible changes for any demand of constructive and commercial character. INCLUDED MATERIALS 1) BOILER COMPLETE WITH: - SUPERIOR HATCH. - INFERIOR HATCH. - DIGITAL PANEL. - SMOKE STACK. - PANELS. - BASE. 2) DOUBLE FALL BURNER. 3) CONE COLLECTOR WITH STAR AGITATOR MOTOR AND REDUCER. OPTIONAL 1) HYDRO FIRE - VALVE. 2) AUTOMATIC ASH EXTRACTOR. 3) REFRACTORY BRICKS. 4) AUTOMATIC SWITCH ON.

MOD. FSS 3-4-5 CONE COLLECTOR WITH RIGHT SIDE HINGE MISURE D INGOMBRO Mod. FSS Pot. resa Pot. bruciata H2 A L G P B K F1 F2 3 29.000(34) 35.000(41) 2.000 630 550 950 4 40.000(47) 48.000(56) 2.000 630 680 1.080 5 50.000(58) 66.000(77) 2.000 630 930 The descriptions and illustrations of the FACI production intends you furnish to simple indicative title. The Firm reserves the right to bring possible changes for any demand of constructive and commercial character. INCLUDED MATERIALS 1) BOILER COMPLETE WITH: - SUPERIOR HATCH. - INFERIOR HATCH. - DIGITAL PANEL. - SMOKE STACK. - PANELS. - BASE. - CONE COLLECTOR COMPLETE WITH: AGITATOR, MOTOR AAND REDUCER. OPTIONAL 1) HYDRO - FIRE VALVE. 2) HEATING COIL SANITARY WATER. 3) PULLOUT DRAWER FOR ASHES. 2) CLEANING BRUSH FOR PIPE CLEANING. 3) 80cm COCHLEA COMPLETE WITH: MOTOR AND REDUCER.

FACI s.a.s. di Matricciani Vincenzo & C. Via Padre U. Frasca snc - 66013 Chieti Scalo (CH) - ITALY Tel. ++39 0871. 564024 - Fax ++39 0871. 561788 www.facisas.com - info@facisas.com ideazione grafi ca GRAFICAMENTE