User s Manual Before using the inverter, you need to read and save the safety instructions.



Similar documents
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

3000W Power Inverter

Online UPS. PowerWalker VFI 1000R/1U

VLT Series 300 Watt True Sine Wave Inverter

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

User s Manual AURORA 1.2K/2.2K

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

How To Use A Power Supply Unit (Upu)

Battery Power Inverters

User Manual 1K/2K/3K Online UPS

BB800 Off-Grid Solar System

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

YSmart Technology Co.,Ltd

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Installation and Operation Guide for PD4000 Series Power Control Center

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

12 Volt 30 Amp Digital Solar Charge Controller

USER MANUAL Online UPS 1K/2K/3K Rack

MAJORSINE Power Inverter

USER MANUAL Online UPS 1K/2K/3K

User Manual HomeGrid 3000 Solar Generator

Manual Ranging MultiMeter

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

TIG INVERTER INSTRUCTION MANUAL

E Manual N Phoenix

TruPower-Portable-500W. Solar Starter kit

12-Volt 10-Amp Regulated Power Supply

10000HXL31/15000HXL31/20000HXL31

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

AutoRanging Digital MultiMeter

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Uninterruptible Power Supply

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

victron energy USER MANUAL GEBRUIKSAANWIJZING MODE D'EMPLOI BEDIENUNGSANLEITUNG Phoenix 12/220 Phoenix 24/220 Phoenix 48/220

Installation and Operation Guide for PD4100 Series Power Control Centers

ST Series POWER SUPPLIES USER INSTRUCTIONS

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

Photovoltaic Solar Energy Unit EESFB

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

BITMAIN. APW PSU Series User Guide

MCR1900 Media Converter 19-Slot Chassis

Manual. Solar Fountain Mobile Phone Charger

ADM1TE 5/30A DIN rail single phase two wire energy meter

User Manual for CH-PFC76810

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

PSC-A5 Solar Charge Controller Manual

2 Installation Explanation

Advantium 2 Plus Alarm

COLOR VIDEO DOOR PHONE CDV-71BE/D

How To Use A Cdm250 Digital Multimeter

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

350, 500, 650 and 1000 MODELS

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

ELECTRIC BICYCLE USER MANUAL

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

INSTRUCTION MANUAL EPSOLAR. Tracer-2210RN / 2215RN. Maximum Power Point Tracking Solar Charge Controller

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

GRID TIE INVERTER MANUAL GRID TIE INVERTER SWEA EUROPE FRIENDLY CARE FOR YOUR EXPENSES AND OUR ENVIRONMENT!

750 WATT Power Inverter

Back-UPS Pro 1300/1500 Installation and Operation

USER MANUAL GEBRUIKSAANWIJZING MODE D'EMPLOI BEDIENUNGSANLEITUNG

Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

INV Series Sine-Wave Inverter. Manual INV12/220-XXXX KLC INV24/220-XXXX KLC INV48/220-XXXX KLC INV110/220-XXXX KLC INV220/220-XXXX KLC

PSACH v.1.0 PSACH 24VAC/6A/1x6A HERMETIC AC power supply for CCTV

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

USER MANUAL Online UPS 6K/10K RACK

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Operating Manual UWAPS-TINY Series

Home Solar Kit Owner s Manual. Model: HS

16/32 Channel 1U Rack Mount CCTV Power Supply

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

1500 WATT POWER INVERTER

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

650W Single Output Power Supply

Installation and Operation Back-UPS 1250, 1300, 1500

Table Of Contents

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Tablet 30W Tablet 92W

XPower 1500 Portable Household Power

User's Guide. True RMS Industrial Multimeter

Transcription:

User s Manual Before using the inverter, you need to read and save the safety instructions.

STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice.

CONTENTS 1. Introduction... 1 2. Important Safety Instructions... 2 3. Inverter Operation... 4 4. Functions... 5 5. Troubleshooting... 12 6. Maintenance and Warranty... 13 7. Technical Specification... 14

1. Introduction Thanks for purchasing STI series inverter. The product is a pure sine wave power frequency inverter which can convert 12/24/48Vdc to 220/230Vac 50Hz based on full digital and intelligent design. It features high reliability, high efficiency, concise outline, full protection functions, easy installation and operation. The inverter can be applied in many fields, such as household appliances, electric tools and industrial devices etc, especially for solar photovoltaic power system. Features: Complete isolation-type inverter technology, noiseless output. Adoption of advanced SPWM technology, pure sine wave output. Dynamic current loop control technology to ensure inverter reliable operation. Wide DC input voltage range. Excellent EMC design. Low output harmonic distortion(thd 3%). LED indicators for input voltage range, load power range, normal output & failure state. Optional energy saving mode. Electronic protect for reverse polarity. Extensive protections: short-circuit, overload, under/over input voltage, over-temperature, and inverter s inner fault identification protections. Wide working temperature range (industrial level). Continuous operation at full power. 1

2. Important Safety Instructions As an AC power supply equipment, the inverter s output voltage is with the same level as that of household power plug. Mind the AC output terminals, or you may get an electric shock! Attentions: Connect the DC input according to the requirement strictly. The power inverter has a relatively wide input range, but too high or too low input may cause problems even destroy the inverter. The surge input voltage can t exceed 18V for the 12V inverters, 36V for 24V inverters, 72V for 48V inverters, or the inverters will be damaged. Do not expose the inverter to humid, flammable, explosive or dust environment. Keep the inverter out of children touch. Inverter input is recommended to connect to battery, the min. capacity of battery(expressed in AH) should be calculated in the following way: 5times of the rated power of the inverter/battery voltage. If for testing purpose, user should select DC power supply current at least twice greater than that of the inverter rated input to keep inverter normal operation. Use DC power supply for testing may cause the damage of the inverter. When the inverter works continuously, its surface may became very hot, please make sure the air ventilation clearance around the inverter is more than 10cm. Keep away from the material or device which may suffer from high temperature when the inverter is working. Do not install the inverter in airproof location and keep enough space around the inverter. The wire connects between battery and inverter should be shorter 2

than 3m, the current density should be less than 3.5A/mm 2 while the output of inverter is fully loaded. If the wire longer than 3m, the current density should be reduced. A fuse or breaker should be used between battery and inverter, the value of fuse or switch should be twice of the inverter rated input current. Do not connect the battery charger or similar devices to the input terminal of the inverter. Do not put the inverter close to the flooded lead-acid battery because the sparkle in the terminals may ignite the hydrogen released by the battery. It s an off-grid inverter, if connect to the grid, the inverter may be damaged. This inverter can only be used singly, parallel connection or in series will damage the inverters. Do not attempt to repair the fault inverter yourself, otherwise it may lead to a serious accident. Please contact the manufacture s engineer. 3

3. Inverter Operation Connect the input and output terminals accurately. Turn on the power using the ON / OFF switch on the front panel. In order to avoid the protections resulted from the surge power, please turn on AC loads one by one after the output of the inverter is normal. Please check it as below: Set the power switch to the OFF position. Insert the load s plug into the inverter s output outlet. Connect the battery ( + terminal with red line, - with black line). Do not connect them by contraries, or the power inverter will not work. Switch the inverter to ON and then turn on the loads one by one. Check the operation state of both power inverter and loads. Green of the failure LED indicator means the state is normal. If there are different loads, it is suggested that turn on the load with large startup current first, such as television, then turn on the load such as lamp when the inverter works stable. If the failure LED indicator is Red and the buzzer alarms or no output when you turn on devices, switch off the loads and power inverter immediately. Check the system by referring to the troubleshooting guide. Turn on the devices again according to the operation methods after the failure is removed. 4

4. Functions DC Input Panel DC Input Terminal Negative DC Input Terminal Positive Protective Grounding Fan Ventilatio n AC Output Panel Load Level Indicator Input Level Indicator Fault Indicator AC Outlet RS485 Port ON/OFF Switch Saving Mode Switch 5

The Optional Outlet Australia/New Zealand European 6

Input Level: Display Input Voltages LED Status 12V 24V 48V RED Slow Blink <10.5 <21 <42 RED 10.5~11 21~22 42~44 ORANGE 11~12 22~24 44~48 GREEN 12~14.5 24~29 48~58 ORANGE Fast Blink 14.5~16 29~32 58~64 RED Fast Blink >16 >32 >64 Load Level: Display AC Loads LED Status AC Load ORANGE <20% GREEN 20%~75% RED >75% RED Slow Blink Overload RED Fast Blink Short Circuit Output & Fault Status LED Status GREEN RED Fast Blink RED Slow Blink ORANGE Fast Blink RED OFF Status Output Normal Overload or Short circuit, No Output Over or Low input voltage, No Output Over temperature, No Output Inverter Fault, No Output Power Off,No Output 7

Alarms Alarms Buzzer Sounds Status Overload or Short circuit, No Output Over or Low input voltage, No Output Over temperature, No Output Inverter Fault, No Output The buzzer stops after 15S. 8

Protections Output Short Circuit Protection The inverter switches off the output immediately when the connecting load is short. Then it recovers the output automatically after delaying 5 seconds for the first time, 10 seconds for the second time, and 15 seconds for the third time. If the short circuit status still remains when the inverter tries to recover for 3 times, you should clear the load faults then restart the inverter manually. Overload Protection Overload 125% 150% 200% >230% Character Continuance 60S 10S 1.5S <0.2S 5 seconds for the first time, 10 seconds for the Recover 3 times second time, and 15 seconds for the third time If the overload status still remains when the inverter tries to recover for 3 times, you should reduce the loads then restart the inverter manually. Input Low Voltage Protection The output is switched off when the input voltage is lower than low voltage protect value, and the output is auto-switched on when the input voltage reach low voltage recover value. User can also manually restart the inverter to switch on output by the ON/OFF 9

switch, when the input voltage is higher than low voltage protect value. Low Voltage Protect Value Low Voltage Recover Value 12V 24V 48V 10.5 21 42 13 26 52 Input Over Voltage Protection The output is switched off when the input voltage is higher than over voltage shut off value, also the output is auto-switched on when the input voltage drops below over voltage recover value. Over Voltage Shut Off Value Over Voltage Recover Value 12V 24V 48V 16 32 64 15 30 60 Fault Protection The inverter will shut down when the output voltage is error or when the inverter has inner fault. 10

Over Temperature Protection The inverter will shut off when the internal temperature is overheating. And it automatic restarts when the temperature recovers to the normal level. Electronic Protect for Reverse Polarity The Electronic circuit works to protect the inverter from damage while input reverse polarity. And the inverter will get right while the input is right. Others Saving Mode When the switch is on Saving side, the inverter will enter into the Saving Mode. It will shut off the output if the loads value is less than 20VA. Then restart and detect the power of the load again after 10s. If the load is more than 20VA, the inverter will turn on the output.otherwise it will shut off output again. It cycles like this. So please don t use the saving mode if the load is smaller than 20VA. 11

5. Troubleshooting WARNING: High voltage is inside the inverter, do not open or disassemble it! Attempting to service the unit yourself may cause the risk of electrical shock or fire! Problem Possible Cause Solution Input LED blink, fault red LED slow blink Load LED blink, fault red LED fast blink Fault orange LED fast blink Fault red LED Input voltage is too high or too low Overload or load short Over temperature inside the inverter Inverter abnormal Measure the input voltage. The inverter recovers when the input becomes normal. Check out if the AC load is within the rated power or whether there is load short. Improve the quality of ventilation and do not block the vents. Restart the inverter when it is cool down. Remove all the connected plugs then restart. If inverter works well, please check the load and line. If the LED keeps red, the inverter has inside faults and should be returned to the factory 12

6. Maintenance and Warranty The casing of the inverters may be cleaned regularly with a damp cloth (not wet) to prevent accumulation of dust and dirt. The screws on the DC input terminals must be tightened. The warranty period of the inverter is 2 year since the date of original shipping. Within the period, we will repair the products for free. Return the defective with shipping cost prepaid. And provide proof of purchasing date. We will pay the return shipping charges within warranty period. The warranty doesn t apply under the following conditions: 1. Damaged by accident, negligence, abuse, improper use 2. Input voltage exceed the nominal input voltage of inverter 3. Unauthorized modification or attempted repair 13

7. Technical Specification Technical Data Types STI200-12-220 STI200-12-230 STI200-24-220 STI200-24-230 Nominal Battery Voltage 12V 24V Input Voltage Range 10.5 ~16Vdc 21 ~32Vdc No Load Consumption 4W 5W Output Wave Pure Sine Wave Output Voltage 220Vac±3% 230Vac±3% 220Vac±3% 230Vac±3% Continuous Power Power 10 sec Power 1.5 sec Surge Power Frequency 200VA 300VA 400VA 640VA 50Hz±0.2% Distortion THD 3%( resistive load) 2%( resistive load) Efficiency at Rated Power 81% 85% Max. Efficiency 88% 89% Dimensions Installation Hole Size Net Weight 314.5 166 100.8mm 200 154mm Φ8mm 4.5kg 14

Types STI300-12-220 STI300-12-230 STI300-24-220 STI300-24-230 Nominal Battery Voltage 12V 24V Input Voltage Range 10.5 ~16Vdc 21 ~32Vdc No Load Consumption 5W 6W Output Wave Pure Sine Wave Output Voltage 220Vac±3% 230Vac±3% 220Vac±3% 230Vac±3% Continuous Power Power 10 sec Power 1.5 sec Surge Power Frequency 300VA 450VA 600VA 960VA 50Hz±0.2% Distortion THD 3%( resistive load) 2%( resistive load) Efficiency at Rated Power 81% 87% Max. Efficiency 90% 91% Dimensions Installation Hole Size Net Weight 314.5 166 100.8mm 200 154mm Φ8mm 5.3kg 15

Types STI500-12-220 STI500-12-230 STI500-24-220 STI500-24-230 Nominal Battery Voltage 12V 24V Input Voltage Range 10.5 ~16Vdc 21 ~32Vdc No Load Consumption 5W 6W Output Wave Pure Sine Wave Output Voltage 220Vac±3% 230Vac±3% 220Vac±3% 230Vac±3% Continuous Power Power 10 sec Power 1.5 sec Surge Power Frequency 500VA 750VA 1000VA 1600VA 50Hz±0.2% Distortion THD 5%( resistive load) 2%( resistive load) Efficiency at Rated Power 81% 87% Max. Efficiency 91% 93% Dimensions Installation Hole Size Net Weight 324.5 186.6 111.8mm 200 174.6mm Φ8mm 7.3kg 16

Types STI700-24-220 STI700-24-230 Nominal Battery voltage Input Voltage Range No Load Consumption Output Wave 24V 21 ~32Vdc 8.5W Pure Sine Wave Output Voltage 220Vac±3% 230Vac±3% Continuous Power Power 10 sec Power 1.5 sec Surge Power Frequency Distortion THD 700VA 1050VA 1400VA 2240VA 50Hz±0.2% 3%( resistive load) Efficiency at Rated Power 87% Max. Efficiency 93% Dimensions Installation Hole Size Net Weight 335 232 123.3mm 230 216mm Φ8mm 9.4kg 17

Types Nominal Battery Voltage Input Voltage Range No Load Consumption Output Wave STI1000-24-220 STI1000-24-230 STI1000-24-220 STI1000-48-230 24V 48V 21 ~32Vdc 42 ~64Vdc 10W 12W Pure Sine Wave Output Voltage 220Vac±3% 230Vac±3% 220Vac±3% 230Vac±3% Continuous Power Power 10 sec Power 1.5 sec Surge Power Frequency 1000VA 1500VA 2000VA 3200VA 50Hz±0.2% Distortion THD 3%( resistive load) 2%( resistive load) Efficiency at Rated Power 87% 89% Max. Efficiency 93% 94% Dimensions Installation Hole Size Net Weight 373 232 123.3mm 260 216mm Φ8mm 11.8kg 18

Environmental Parameters Working Temperature -20 ~+50 Storage Temperature -35 ~ +70 Humidity Altitude < 95%(N.C.) < 5000 m (Derating to operate according to IEC62040 at a height exceeding 1000 m) Others Insulation Resistance Dielectric Strength Between DC input terminals and metal case: 550MΩ; Between AC output terminals and metal case: 550MΩ. Between DC input terminals and metal case: Test voltage AC1500V, 1 minute Between AC output terminals and metal case: Test voltage AC1500V, 1 minute Version No. : V1.2 19

BEIJING EPSOLAR TECHNOLOGY CO., LTD. Tel: +86-10-82894112 / 82894962 Fax: +86-10-82894882 E-mail: info@epsolarpv.com Website: http://www.epsolarpv.com/