Theaters Tilburg - Concertzaal. Address

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Schouwburg & Filmtheater Agnietenhof Venue: 4000 AN Tiel. info@agnietenhof.nl techniek@agnietenhof.nl

Les Docks / Av. de Sévelin Lausanne! Technical Rider

Theater De Meervaart Amsterdam Red Hall (Rode Zaal) and Blue Hall (Blauwe zaal)

PRODUCTION SPECIFICATIONS

Stadsschouwburg Amsterdam Rabozaal website technical rider - 13th of may 2011

HEBDEN BRIDGE PICTURE HOUSE TECHNICAL INFORMATION FOR HIRERS UPDATED OCTOBER CAPACITY. Stalls: 257 Seats per row: 22(Max)

Event Planner/Venue Specialist Phone:

SHUBERT THEATER 247 College Street, New Haven, CT

FOOTHILL COLLEGE FINE ARTS FACILITIES OFFICE

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS.

STAGE SPECIFICATIONS. Newberry Opera House

TEATR GROTESKA ul. SKARBOWA KRAKÓW TEL groteska@groteska.pl Update

CORONET LONDON / Technical Information Pack (Updated - 1 st January 2015)

Technical Specifications Version

PRODUCTION SPECIFICATIONS THE MANÈGE (RIDEHUSET)

Technical Specifications Lyric Theatre Belfast Danske Bank Stage

Special Events & Space Rentals

TECHNICAL INFOS CAPACITY 2 STAGE 2 TECHNICAL ROOF GRID (NOT YET AVAILABLE) 2 STAGE CURTAINS 3 FOLLOWSPOTS PLATFORM 3 ELECTRIC INSTALLATIONS 3

MEETING PACKAGES 400 LEVEL

Traktor Audio Configuration

Technical & Production information. Updated

Douglas J. Cardinal Performing Arts Centre. Information and Technical Specifications

Interactive System Audio-Visual Equipment and Event Management

Theatre Manager: Linda Aitken (03) ,

Introduction. Meeting Spaces. Hynes Audio Services

The Swingle Singers RIDER PART 1: TECHNICAL REQUIREMENTS A Cappella Show

Blair School of Music

On-air studio: page 1 of 5

Lower Level (Level L) Exhibit Halls A, B & C

TECHNICAL RIDER

Contacts. The Space. Lx Kit List. Sound Kit List. Stage Management. Health & Safety Policy

Site Plan. Parking. Main Auditorium. Large Auditorium. Lobby. Parking. Small Meeting Room. Dock & Broadcast Truck Bay

Special Events Policies & Procedures

TECHNICAL RIDER HULK

Adress: Teatertorvet DK Horsens Denmark. Postal adress: P.O.Box DK 8700 Horsens. Phonenr, etc..

J. W. ENNIS AUDITORIUM CENTENNIAL SECONDARY SCHOOL WELLAND, ONTARIO THEATRE TECHNICAL INFORMATION MARCH 29, 2013

L ORATORIO D AURELIA. Technical Rider. Administration: Didier Bendel Cell phone:(0049) (0) didierbendel@gmx.

The Theatre Dictionary

UCLA Department of World Arts and Cultures Glorya Kaufman Dance Theater (Room 200) Technical Information

STADSSCHOUWBURG UTRECHT... 5 MAIN AUDITORIUM... 7 MARLEY DANCE FLOOR MASKING STAGE RAISERS ADDRESS AND DRIVING DIRECTIONS...

Bradford Odeon. Tim Ronalds Architects

TECHNICAL RIDER AUDIO - MAINSTAGE F.O.H. CONSOLE F.O.H. DRIVE MONITOR SPEAKER MONITOR CONSOLE P.A. LINE ARRAY 4 WAY

Théâtre de Suresnes JEAN VILAR presents RAYAHZONE

See you soon in Scottsdale! December 6-7, 2016 Scottsdale, AZ. Exhibitor Package. 3rd Annual Vegetation Management Conference.

Mid-Range Complete Radio Station Package

A1.5 Classroom Standards

Hotel Accessibility Pack

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Wentz Concert Hall and Fine Arts Center 171 E. Chicago Avenue Naperville, IL Existing Electrical Systems Will Lesieutre

TECHNICAL SPECIFICATIONS Paramount website: Paramount

ARRIVING AT THE HOTEL

Table of Contents. Facility Complimentary Services and Labor Meeting Room Complimentary Services and Equipment...2

2016 Facility Rentals

T Zone Weekly Timer

Auditorium Audiovisual System User s Guide

Accessibility plan. Mövenpick Hotel 's-hertogenbosch

POWER CABLES 16 amp & 32 amp single phase cable

YOUN SUN NAH & ULF WAKENIUS Technical rider duo 2013

the audio/video + lighting menu

Pump House Regional Arts Center 119 King La Crosse, WI

Community Usher Handbook

Appendix 3H A/V and Video Conferencing Standard

Video & Data Display Equipment. Projection Equipment. LIGHTING EQUIPMENT Please call for customized Lighting Packages.

Artist: Michael and Amy Rider: Corporate - Grand Pianos

Selfpowered Artikel Nr. Brand Type Specifications Price QSC K watt 25

Hotel Accessibility Pack

Equipment Guide Human Resources Training Room Suite 205, Building 3377

PA and Lighting Packages - Ready to Go

GUSMAN CONCERT HALL INFORMATION PACKAGE

Rental Policy & Pricing 2013

MEETING AND EVENT PLANNING GUIDE. Floor Plans Capacity Charts Location 1

NCSU CBE Conference Room 2018 EB1 Touchpanel Users Guide

CENTER THEATER TECHNICAL SPECIFICATIONS 404 SEAT PROSCENIUM THEATER WITH FLY LOFT

Introduction. Pre-Arrival. Arrival & Car Parking Facilities. Main Entrance, Reception & Ticketing Area

RESOURCES. Telehealth. Provincial Health Services Authority. Telehealth & General Meeting Room Design Requirements

Production Services Department

ACCESSIBILITY STANDARD

$2.25 $1.20. Display device w/ diagonal screen size: 29 : $ : $ : $35.00

Perth Concert Hall. Technical and Production Information

Reynolds Performance Hall Facility Regulations and Fee Schedule

Existing Stage Facilities at LCSD s Performance Venues

Transcription:

Theaters Tilburg - Concertzaal Address City Theatre Hall Tilburg Theaters Tilburg Concertzaal Address loading dock Concertzaal Schouwburgring, left to the main entrance Schouwburg Tilburg Address stage door Concertzaal Oudedijk 1 Parking/Main entrance artists Louis Bouwmeesterplein 1 Postal code/city 5038 TN Tilburg Postaddress Postbus 3035 Postal code/city 5003 DA Tilburg Telephone Ticket shop + 31 13 543 22 20 General + 31 13 549 03 90 Publicity + 31 13 549 03 90 E mail techniek@theaterstilburg.nl Personal data Stage manager Concertzaal Pernel van Herpt +31 13 549 03 56 Pvanherpt@theaterstilburg.nl Technical Coordinator Liek Jussen +31 13 549 03 19 ljussen@theaterstilburg.nl Technical Manager Dick Doeze Jager +31 13 549 03 41 Ddoezejager@theaterstilburg.nl Standard working hours Lunch 12:30 13:00 Diner 17:00 19:30 Showtime evening 20:30 / matinée 14:30 Opening hours green room in consultation

Parking/Accessibility The main entrances of the Schouwburg, Concertzaal, Studio as well as the Filmfoyer are located at the Schouwburgring. Because of the one-way Schouwburgring there are separate directions for reaching the loading dock of the Concert Hall and parking. Directions loading dock Concertzaal From the A58 from Breda, Den Bosch and Eindhoven: Take exit 11, Tilburg Center / Goirle. At the traffic lights follow direction Centrum Tilburg towards Centrum Tilburg. Keep right after the next traffic light, on the Ringbaan Zuid. After 3.7 km go left at the Broekhovenseweg. Keep right after 0.7 km, the Piusstraat. After 0.7 km turn left at the traffic lights at the Paleisring. After 0.8 km you will see to your left the loadingdock of the Concert Hall. Directions Parking Louis Bouwmeesterplein From the A58 from Breda, Den Bosch and Eindhoven: Take exit 11, Tilburg Center / Goirle. At the traffic lights turn follow direction Centrum Tilburg towards Centrum Tilburg. Then stay straight and follow the Ringbaan West for 1.2 km. At the fourth traffic lights, direction Tilburg Centrum, on the Bredaseweg. After 1 km this street turns into the Schouwburgring, then follow the signs to parking Louis Bouwmeesterplein. The stage door of the Theatre, Studio and Film Foyer is located at the Louis Bouwmeesterplein no. 1. For the stage door of the concert hall, you walk around behind the theater. After 0.2 km the road makes a right turn and you see an iron staircase. Here is the stage door, opposite to Oudedijk no. 1. Parking As of September 1, the municipality of Tilburg no longer provides parking tickets to sell to our guests. It s possible to pay cash, with chipknip or creditcard in all parking garages in Tilburg. Late night shopping: on Thursday parking is difficult Due to late opening on Thursday you have to take account of extra traffic. Also, extra traffic is expected on Sunday shopping and more shopping days around Christmas and Santa Claus. Public Transport From Central Station it takes about 10 minutes to walk to Theaters Tilburg.

Loadingddock Level: street level, indoor Stage on the second floor! Dimensions (LxWxH in cm) Elevator 300 x 168 x 220 Dockleveler 250 x 195 x 120 height variable.... <> 120 Trucks 870 x 380 x 400 Trailers should be moved after unloading! Smallest passage to (in cm) Stage 170 x 210 Changing Rooms 170 x 210 Main Power Loading dock 2 pieces - 32A/5p 1 piece - 63A/5p 4 pieces - 220V SCAN Audio - 2x Socapex 37p on standard NOB (Other side of the cable comes back on center stage) Maximum capacity Main floor 600 First balcony 90 Second balcony 90 Sound seats: up to 2 x 8 chairs Dimensions see drawing stage 16 x 10 Stage Floor Material: hardwood Kerowing1 Angle of stage floor: 0, i.e. flat Ballet Floor Ballet floor 10 x 15 meters black Electrical power supply stage 2 x CEE standard 63A/5p stage left (1 x audio, 1 x video) 1 x standard CEE 125A/5p stage left (light) Drapery 5 legs left and right, 12 meter stage opening 4 Black tabs 10 meter high, 14 meter wide

Light Desk: Roadhog 4, wing in consultation DMX outputs: controlroom, hall (sound seats), stage right, backstage, technical circulation (left and right) Fixed lights (see drawing) 12 x Zoomprofile 2 kw Robert Julliat 710SX 18 x P.C. 2 kw ADB with barndoors Lighting equipment 10 x Zoomprofile 12 x ADB P.C. 2 KW with barndoors 20 x Source Four 20 st. 750 W 6 x Four bars 750 W Source Four 10 x Clay Packy B-Eye K10 Dimmers/connections Digital dimmers: 72 Multi's: 6st. Harting, wired at technical circulation, Floorconnections 16 x 2,5 kw Sound D&b line array: Centre cluster 5 Q 1 loudspeaker 1 Q 7 loudspeaker 1 Q SUB Subwoofer Left and right (sub CSA mode) 2 Qi 1 Loudspeaker 2 Qi sub loudspeaker 1 Qi sub CSA in fills balconies 4 E3 Loudspeaker front fills Monitors 6 x D&B Max12 Amplifiers 3 x D&B D12 Front of house Digico SD11, in consultation SD9 Peripherals 1 x CD player Tascam CD 301 MKII

Microphones 2 x Sennheiser e845 handhelds EW 345 G3 2 x Sennheiser supernier shortgun condensator microphones MKH 416 (fixed position) Besides the fixed installation Theaters Tilburg has a fairly wide range of mixers, microphones, transmitters, effects, CD / MD players, monitors and other peripherals with sufficient wiring. In consultation per room available. For information and availability please contact the appropriate stage manager. Connections Sound Harting 108p, 24 XLR Via 2 socapex thru male/female 6 out, 4 aux, 2 record Network for D-rack Communication Intercom Connections: sound booth, sound seats, stage right, follow spot, grid left and right. Intercompost Inter. ASL Micro Post Intercom beltpack 4pcs. ASL including headset Various connections A and B lines of communication on stage and in room Call to: public spaces, corridors, dressing rooms, auditorium. Stage sound in dressingrooms Monitor: public foyers (2x), green room, theater attendance Various Sound Inductive coverage for room level Phonak system with universal FM receivers MyLink Position sound seats in room: 17 meters from zero Grand piano Steinway D grand piano type Serieno.535544, 1996 Yamaha Piano Several piano stools Video AV Beamer Panosonic wuxga lcd projector incl. lens, type PT-EZ770ZEJ Projection screen 1 Stumpfl Monoblox 64 (mobiel) projectiescherm, type BXV-AW630/R10 - afm 630 x 401 cm (610 x 381 cm effectief) Theaters Tilburg offers various audio visual equipment including projectors, multimedia PCs and mixer / switching units. Availability and accessibility in consultation with the stage manager. Risers 20 x risers Legs 60 x 20cm for 15 risers Legs 60 x 40cm for 15 risers Legs 60 x 60cm for 15 risers Legs 40 x 80cm for 10 risers

100cm x 32 feet for 8 risers Steps 2 x 20, 40, 60, 80 cm high Black curtains 20, 40, 60 and 80 cm Gates 10 x 95 cm high, 100 cm wide linkable Orchestra 1 x Conductorstage 100cmx100cm. 20cm high with stand 90 x orchestra seats with adjustable seat without armrest 60 x height adjustable desks 25 x reading lamps serving desks - loose fit Tools Aerial platform to max working height 9.40 meters, ALP-lift Dressing Rooms 2 Ensemble Dressing rooms, capacity 40 persons. Hot and cold running water, make-up tables. Level 1 5 Soloists Dressing rooms, capacity 4 pers. Sink, shower, make-up tables Level -1 Additional dressing rooms without facilities in consultation. Rigging For the standard arrangement of the trusses and motors see map. 4 x 0.25 ton engine hoist Fixed hung in specified points. 16 x 0.5 ton engine hoist Mobile are attached at specified points