Auxiliary Power Unit (APU) for Military Vehicles



Similar documents
Diesel Engine Driven Generators Page 1 of 6

Magnum Mobile Generator MMG55 Specifications

GENERATOR SET, DIESEL ENGINE, MODEL MEP-903A

DIESEL GENERATOR SETS

Technical Specification. Generating Set with Waukesha engine burning natural gas

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Frequently Asked Questions Generators

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Signature and ISX CM870 Electronics

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Prime Power Services, Inc. Georgia, Carolinas NFPA 110 Standards for Emergency & Stand by Generators June 1, 2010

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

ENGINE COOLING SYSTEM

Table of Contents. Introducing AYGO. Accessing your vehicle 2 3. Lights 9. Wipers 10. Electric windows 4. Gear change 11

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

October 8, WHP Waste Heat-to-Power Fuel and Emission Free Power

Annex-A TECHNICAL SPECIFICATION

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

New 27 hp 2 Cylinder Liquid-Cooled Engine

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

2013 Tier 4 Compliant. High capacity and reliability. Low fuel consumption and noise. Let Vector units energize your bottom line.

Pneumatic Forklift Trucks D15G / D18G G15G / G18G. 1,500kg to 1,750kg Capacity

The Yachtmans Choice...

SPEEDROC D30. Surface Drill Rig for marble, granite, sandstone and limestone in the dimension stone industry.

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

LOAD BANK TESTING PROCEDURE

3516 Industrial Engine

The State Fire Marshal's Office and the VDH/Office of Licensure and Certification. Generator Testing in Nursing Facilities

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

EKOS Cart. Instructions for Use

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDS1 Swing Gate Valve. by AMOT. Overview. Typical Applications. Key Features and Benefits

Marine Generating Sets 3.7 to 50 kva

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

Spark-ignited generator set

INDUSTRIAL ENGINE RATINGS GUIDE

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

Marine Generators Pocket Guide

COOLING SYSTEM Section Page

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

2006 Volkswagen Maintenance Schedule by Miles/Kilometers

How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

Diagnostic Fault Codes For Cummins Engines

Features. Kubota Diesel Engine. Clean Emission. Electronic Governor. High Lift Capacity

Contractors Guide Central Inverter System Installation

The reliability of the grid

USER S MANUAL HSC-24A

Portable Compressors MOBILAIR M122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min.

Advanced Engine Cooling Systems for Vehicle Application

Fire Pump Plan Review March 2010

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

How To Control A Power Command Powerplant

Cooling system components, removing and installing

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

PUMP MAINTENANCE SCHEDULE AND CHECKLISTS

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

Manual for Fire Suppression & Methane Detection System

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

How To Use A Cat Diesel Engine

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

I STAR COMPUTER CO., LTD

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Cat Electronic Technician 2015C v1.0 Product Status Report 2/16/2016 9:19 AM

Diesel Generator Set Model DGDK 60 Hz

VLT Series 300 Watt True Sine Wave Inverter

830-II *330492* Cummins 4 Cylinder Engine Breakdown Rev. 00

Dehumidifier Users manual. For Models: DH45S DH65S

Introduction to Electronic Signals

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Technical data. Danfoss DHP-A

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Volkswagen Golf > VW Rabbit GTI 2006->

Manual. Solar Fountain Mobile Phone Charger

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

C18 ACERT Fire Pump Tier bkw/ rpm

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

INSTRUMENT PANEL Volvo 850 DESCRIPTION & OPERATION ACCESSORIES & EQUIPMENT Volvo Instrument Panels

Cooling system components, servicing

Maintaining the Beauty and Performance of Your Boxster

Diesel Generating Set

307E. Mini Hydraulic Excavator. Standard Bucket Size 0.33 m 3 Engine Model Cat C2.6 DI Turbo. Weights

Mobile Data Power Model: MDP-25

Transcription:

Auxiliary Power Unit (APU) for Military Vehicles Jeff Humble General Dynamics Land Systems 640 Seminole Rd. Muskegon, Michigan 49441 (231)780-5609 humblej@gdls.com Page 1

APU Program Summary Developed under contract to Marine Corps Systems Command in 2007. Spin-off of On Board Vehicle Power (OBVP) program for 30 kw export power and 10 kw power on the move for HMMWV1123. OBVP system portability study to Mine Resistant Ambush Protected (MRAP) vehicles Portability study change in scope from AC power to 28VDC power OBVP MRAP solution evolved into the APU APU Brass Board and Pre-Production hardware fabricated and tested in 2008 Brass Board accumulated 144 hours run time APU Pre-Production hardware government testing is ongoing Page 2

APU Product Specification Rated power: 14.2kW at 0-12,000 ft, 508A, 28VDC Ambient Operating Temperatures: -25 to 131 F Weight: 650 lbs. Size: 38 (L) x 63 (H) x 25 (W) Fuel: DF-2, JP-8, Ultra Low Sulfur Diesel (ULSD) Coolant: Water-Ethylene Glycol (WEG) or Water- Propylene Glycol (WPG) Sand and Dust: Complies with MIL-STD-810F Emissions: Complies with EPA Interim Tier 4 Fuel Consumption: 1.2 gal/hr at 10kW, 1.7 gal/hr at 14kW Page 3

System Description Diesel powered generator system with Commercial Off The Shelf (COTS) components Stand alone system independent of the vehicle except for fuel supply and batteries for starting Provides 508A, 28VDC directly to vehicles power distribution system to augment vehicle power Operates as load following for best fuel consumption rate and reduce wet stacking Manufactured by General Dynamics Robotics Systems Export power capability through vehicles NATO slave Page 4

APU Hour Meter Circuit Breakers Air Cleaner Assy Muffler Alternator Bus Bar Engine Controller Diesel Engine Engine Oil Filter Oil Level Dip Stick Fuel Filter Coolant Filler Neck Belt Drive System Coolant Surge Tank APU Enclosure Engine Mounts Page 5

APU Engine Kubota V1505-T, turbocharged, 44.2 HP diesel engine COTS hardware, in production since 1991 Weight: 251 lbs Size: 24 9(L) x 24.5 (H) x 17 (W) Page 6

APU Generator C.E. Niehoff 570A, 28VDC Alternator COTS hardware Weight: 115 lbs. Air cooled with self contained cooling fan Rated for ambient air temp - 65 to 200 F 1500 8000 RPM Belt driven Page 7

APU Cooling System Closed loop cooling system Variable speed COTS fans, reverse direction at periodic intervals to clean radiator core Custom sized Weight: 30 lbs. Size: 26 (L) x 15.5 (H) x 4.2 (W) Page 8

APU Controls Remotely located inside vehicle On/Off switch, normal operating and warning lights, voltage and amperage indicators Battle Override to disable automatic shut down due to high coolant temp or low oil pressure Page 9

APU Enclosure Lightweight aluminum structure or optional armored enclosure Large door on front, removable top, bottom and back panels for easy access for maintenance Door locks for security Page 10

APU Operation Operated from inside vehicle with remote MMI panel Once started, operation is automatic Load following and slaved to vehicle voltage regulator. Automatically controls APU engine RPM to match alternators output to that of the demand from the vehicle. Load following helps reduce wet stacking and improves fuel economy Automatic precautionary engine shutdown 30 seconds after a high coolant temp or low oil pressure is detected Battle override to disable automatic precautionary shutdown Page 11

APU Maintenance Maintenance checks, fluid level checks and fill points are accessible at front of APU Clear access to system for maintenance and systems inspection/checks from large front door and access panels All major components can be removed and replaced while the APU is on the vehicle without needing to remove other major components first Reliability prediction of 1213 hours Mean Time Between Failures (MTBF) generated from Nonelectric Parts Reliability Data (NPRD) Page 12

Summary Production ready APU with COTS major components Independent of vehicle engine, APU failure or destruction will not affect vehicle mobility or performance Can be Reconfigured for other military vehicles without changing COTS hardware Page 13