Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser



Similar documents
Laminar Flow Panel. Type LFP 2/2.4/B/2. Telephone +44(0) Telefax +44(0)

Incorporating V2.3. Product spec >>> > Series ECG - Egg Crate Grilles. > Series ECG45-45 Egg Crate Grilles

Grilles & Diffusers Series LFP Incorporating

INDEX. Chapter8. air master. Perforated Ceiling Diffusers

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

SERIES L. Fineline & Broadline. Linear Strip Grilles GRILLES 12

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

DIY CABINET REFACING INSTALLATION GUIDE

MGB Chrome Bumper Conversion

Integral Kit Instructions

K17.11 DOOR BOLTS K17 DOORS

security products metric sizes Redefine your comfort zone.

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

GENUINE PARTS INSTALLATION INSTRUCTIONS

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

Installation Instructions For Slider Casement Air Conditioners

majestic install ation guide barcelona three sided enclosure 24mm surface mounted wall channels and underframe to base

All-Season Sunroom Sliding Glass Door Installation Instructions

Rooflight INSTALLATION INSTRUCTIONS

Rack installation instructions

Original Assembly Guide

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

DE Frame with C Series Sidelight

Installation Guide. Bath and Wall Surrounds SERIES B

AMPSEAL* Automotive Plug Connector and Header Assembly

INSTALLATION OF A BAY WINDOW

Rebuild Instructions for and Transmission

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

THE CANON 106 TONER CARTRIDGE

Basic Spring Motor Roller Shades

Window Installation Instructions

KEYPAD LOCK RETROFIT KIT

plumbing products guide

SHUTTER INSTALLATION INSTRUCTIONS. AUGUST 2006 Version 2

Gate Leg Drop Leaf Table Plans

INSTALLATION AND SERVICE MANUAL

Cooktop Low-Profile Ventilation Hoods

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS

Edition Perfect combination ratiopacpro Electronic P Edition kaging www clear order..biz information in the catalogue

Premier & Deluxe 3-Season Room Sliding Glass Door

Sliding and Folding Door Fittings Sliding Door Accessories

Skirt 1 / 4. The Skirt. The skirt patterns were downloaded from Mark's site but they need expanding before they can be used.

Flue Installation. High Efficiency Condensing Boilers

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

HVAC Vents & Diffusers

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB

sound reduction systems for commercial, educational and industrial environments

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

TONNEAU INSTALLATION GUIDE

apple Service Source PowerBook G4 (DVI) Updated 4 December Apple Computer, Inc. All rights reserved.

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

I-Line - Snap-On Feature

Wren Kitchens Installation Tips Carefully check your kitchen delivery Measuring out and marking up Fitting the base cabinets...

Installation Instructions

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS PHILLIP STREET, SYDNEY

Installation instruction do88 Intercooler for Volvo S40 / V50 / C30

How to Build a Poker Table

K17.12 Door closers K17. Doors

5800 Temperature Sensor Cable Assembly

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version

Speed-Mat Rectangle Cutter

HDA

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Slides and Drawers. The right collection

Installation Instructions

Colonnade Security Pipe

IN00378 (rev A) Corner Entry

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

KAWAI VERTICAL PIANO REGULATION MANUAL

These instructions will show you how to install an internal door into a non-loadbearing partition wall. The instructions are split into three parts.


IMPORTANT! READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION. Step 1:

Installation Instructions Avalanche XUV Cap IMPORTANT! IMPORTANT!

NATIONAL INSTITUTE OF BIOLOGICALS

R O A D M A S T E R, I N C.

Wetroom Panel (Concealed Fix)

Modular Locomotive System Instruction Manual for HBK5 Billy Body Kit

BLADE S-MAX Cabinet for Blade Server

Owner's Manual & Assembly Instructions

How to build a Pizza Oven in 4 days

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

Modular Locomotive System Instruction Manual for HBK8 George Body Kit

How To Install Your Frameless Shower Enclosure

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Installation Instructions S

BODY-12, Door Handle - Removal, Installation, and Adjustment

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)

R O A D M A S T E R, I N C.

Accessory Manual Ventilation Section Model Comfort Circle

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

Installation instructions, accessories - Handsfree for cellular phone, system B, entry level

DSRQ - DSRSQ - DSRSQ-THERM

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

Transcription:

1/1.5/B/1 Plaster In Grilles AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser TROX UK Ltd Caxton Way Thetford Norfolk IP24 3SQ Telephone +44 (0) 1842 754545 Telefax +44 (0) 1842 763051 e-mail trox@troxuk.co.uk www.troxuk.co.uk

Contents Description Description AHP Grilles ADMP Diffusers AK-AHP & ADMP Plenums ALSP Linear Slot Diffusers AK-ALSP Plenum Boxes 2 3 4 5 6 7 Installation Instructions AK Plenums Installation Instructions Blanking Plate Installation Instructions Grille / Diffuser Core Removal & Installation AHP Core Removal & Installation ADMP Order Details 8 9 10 11 12 13 Description Materials TROX range of plaster in grilles can be used as air terminal devices for the ventilation of buildings and spaces in terms of supply air and extract (exhaust) air. AHP is designed for vertical installation within walls and bulkheads and provides a horizontal supply air discharge perpendicular to the mounting surface. ADMP & ALSP are designed for horizontal installation within ceilings and provide a horizontal supply air discharge parallel to the mounting surface. The grilles and linear grilles are manufactured from aluminium extruded sections. The standard finish is polyester powder coat to RAL9010:20%. Other standard colours from the RAL range are available on request. Optional ancilleries such as blanking plates and alignment fixures are finished in RAL9005 (black). Supply or return air plenums are supplied natural finish, galvanised steel. The installation can be carried out directly into a builders work cut out within a plasterboard wall, with the outer border providing a surface suitable for plaster skim. 2

AHP Linear Bar Grilles Construction Dimensions Materials AHP The front border is designed to integrate seamlessly within plasterboard builders work opening, with concealed screw fix installation. The air discharge can either be at an angle of 0 (AHP-0) or 15 (AHP-15) with fixed horizontal profiled blades. The central core is removable and provides access to TROX type AK plenums (if specified). Optional blanking plates can be provided to cover non-active grille sections where supply or extract air transfer is not required. Blanking plates can be requested with optional 6mm foam lining to provide a thermal insulation between the occupied space and services void. Blanking plates supplied in 1000mm lengths for site cutting and installation where required. 6mm foam is supplied in 1000mm lengths for cutting and installation to blanking plates by others. Materials AHP grille border and blades are manufactured from aluminium extruded sections. The standard finish is polyester powder coat to RAL9010:20%. Optional blanking plates are manufactured from 0.7mm galvanised steel. The standard finish is polyester powder coat to RAL9005 (black). Other standard colours from the RAL range are available on request. Performance Refer to product leaflet 1/1.2/B/2 for full technical performance data. AHP AHP-0 Front border Blade 2,0 AH-0 'H' - 4 / 'L' - 4 12,5 20,0 32,5 3 5.5 5 3 AH-15 WAP-0 WAP-15 Blanking Plate 'H' - 22,0 1000,0 Finite Grilles ('L'-4) MIN OPENING SIZE ('L'-16) NECK SIZE ('L'+24) O/A FLANGE ('H' + 24) O/A FLANGE Grille Finite Linear Nominal Height SECTION LENGTHS 'L' 'M' 'E' 150-2400mm - - - 1800mm 900-1800mm 'H' Min = 75mm 'H' Max = 200mm (25mm increments) Linear Grilles ('E'-8) O/A NECK (AFTER TRIMMING) ('E'+12) REF O/A FLANGE (AFTER TRIMMING) ('M') O/A NECK (AFTER TRIMMING) ('M') O/A FLANGE (AFTER TRIMMING) ('E'-8) O/A NECK (AFTER TRIMMING) ('E'+12) REF O/A FLANGE (AFTER TRIMMING) ('H' + 24) O/A FLANGE 3

ADMP Linear Diffusers Construction Dimensions Materials ADMP The front border is designed to integrate seamlessly within plasterboard builders work opening, with concealed screw fix installation. The air discharge can either be one or two way with fixed horizontal profiled blades. The central core is removable and provides access to TROX type AK plenums (if specified). Optional blanking plates can be provided to cover non-active grille sections where supply or extract air transfer is not required. Blanking plates can be requested with optional 6mm foam lining to provide a thermal insulation between the occupied space and services void. Blanking plates supplied in 1000mm lengths for site cutting and installation where required. 6mm foam is supplied in 1000mm lengths for cutting and installation to blanking plates by others. Materials ADMP grille border and blades are manufactured from aluminium extruded sections. The standard finish is polyester powder coat to RAL9010:20%. Optional blanking plates are manufactured from 0.7mm galvanised steel. The standard finish is polyester powder coat to RAL9005 (black). Other standard colours from the RAL range are available on request. Performance Refer to product leaflet 2/2.4/B/1 for full technical performance data. ADMP ADMP-1 Front border Blade 12,5 2,0 22 'H' - 4 / 'L' - 4 3.4 20,0 32,5 Blanking Plate 'H' - 22,0 1000,0 Finite Grilles ('L'-4) MIN OPENING SIZE ('L'-16) NECK SIZE ('L'+24) O/A FLANGE Grille Finite Linear Nominal Heights SECTION LENGTHS 'L' 'M' 'E' 150-2400mm - - - 1800mm 900-1800mm 166mm, 203mm ('H' + 24) O/A FLANGE Linear Grilles ('E'-8) O/A NECK (AFTER TRIMMING) ('M') O/A NECK (AFTER TRIMMING) ('E'-8) O/A NECK (AFTER TRIMMING) ('E'+12) REF O/A FLANGE (AFTER TRIMMING) ('M') O/A NECK (AFTER TRIMMING) ('E'+12) REF O/A FLANGE (AFTER TRIMMING) 4

AK-AHP & ADMP Plenum Boxes Construction Dimensions Materials AK-P Plenum s Damper s TROX type AK-P plenums boxes can be supplied for supply air and extract air applications to suit AHP & ADMP finite or linear grilles. The plenum box is suspended using support wires or threaded rods (supplied by others), using the drilled holes in the plenum return edge or hanging brackets when provided. The type AK-P plenum box comprises a casing with horizontal or vertical circular spigot for duct connection, with or without opposed blade volume control damper (-AG) or combined, individually adjustable control blades and opposed blade volume control damper (-DG). ZH Horizontal supply AH Horizontal extract ZV Top entry supply AV Top entry extract Materials AG DG Opposed blade action volume control damper, adjustable via the front face. Volume control damper as...-ag plus a set of individually adjustable vertical air pattern control blades. ZH & ZV plenums come complete with perforated internal baffles to promote even air distribution with optional 12mm thick black faced, Class 'O' internal lining (... -D) The plenum box is made from galvanised sheet steel, and is supplied self-finish. Plenums are manufactured with a 15mm internally formed flange at each end, with factory fitted foam seal. AK-P....- ZV /...-AV 270,0 O/A O/A LENGTH ('L' - 5) MAX LENGTH ('L' = 2100) 148,0 I/S 'AG', 'D' or 'DG' DAMPER (Optional) FITTED IN PLENUM 'D' +22 (Min. 'H' +20) 'D' DIA SPIGOT 'H' - 5,0 O/A 'LN' ACTIVE LENGTH ('L' - 35,0) INTERNAL LINING BELOW BAFFLE - TYPE 'A' ONLY 32,0 AK-P....- ZH /...-AH O/A LENGTH ('L' - 5) MAX LENGTH ('L' = 2100) 'D' + 150,0 Min. 1000 Max 'D' DIA SPIGOT 'AG', 'D' or 'DG' DAMPER (Optional) FITTED IN PLENUM INTERNAL LINING BELOW BAFFLE - TYPE 'A' ONLY 32,0 'H' - 5,0 O/A 'LN' ACTIVE LENGTH ('L' - 35,0) 5

ALSP Linear Slot Diffusers Construction Dimensions Materials ALSP The front border is designed to integrate seamlessly within plasterboard builders work opening, with concealed screw fix installation. The air discharge can either be one or two way horizontal or vertical with integral baffle plate and adjustable air control blades. Optional blanking plates can be provided to cover non-active grille sections where supply or extract air transfer is not required. Blanking plates can be requested with optional 12mm foam lining to provide a thermal insulation between the occupied space and services void. Blanking plates supplied in 1800mm lengths for site cutting and installation where required. 12mm foam is supplied in 1800mm lengths for cutting and installation to blanking plates by others. Materials ALSP grille border and blades are manufactured from aluminium extruded sections. The standard finish is polyester powder coat to RAL9010:20%. Optional blanking plates are manufactured from 0.7mm galvanised steel. The standard finish is polyester powder coat to RAL9005 (black). Other standard colours from the RAL range are available on request. Performance Refer to TROX Quick Selection Guide or local TROX Representative for performance data. ALSP ALSP-2 OPENING SIZE 'A' + 18 Front border 25,0 2,0 77,0 Blanking Plate = = = = = = = = 100 MAX 1800,0 'A' + 4,0 (O/S) Finite Grilles ('L' + 38,0) MIN OPENING SIZE Grille ALSP20-1 Slot Dimensions 'A' 41,0 Grille ALSP25-1 Slot Dimensions 'A' 46,0 ALSP20-2 Slot 80,5 ALSP25-2 Slot 90,5 (L+71,0) O/A FLANGE ALSP20-3 Slot ALSP20-4 Slot 120,0 159,5 ALSP25-3 Slot ALSP25-4 Slot 135,0 179,5 Linear Grilles ('A' + 51,0) O/A FLANGE Grille Finite Linear SECTION LENGTHS 'L' 'M' 'E' 600-1800mm - - - 1800mm 900-1800mm ('E'-8) O/A NECK (AFTER TRIMMING) ('E'+35,5) REF O/A FLANGE (AFTER TRIMMING) ('M') O/A NECK (AFTER TRIMMING) ('M') O/A FLANGE (AFTER TRIMMING) ('E'-8) O/A NECK (AFTER TRIMMING) ('E'+35,5) REF O/A FLANGE (AFTER TRIMMING) ('A' + 51,0) O/A FLANGE 6

AK-ALSP Plenum Boxes Construction Dimensions Materials AK Plenum s Damper s TROX type AK plenums boxes can be supplied for supply air and extract air applications to suit ALSP finite or linear grilles. The plenum box is suspended using support wires or threaded rods (supplied by others), using the drilled holes in the plenum return edge or hanging brackets when provided. ZH AH ZV AV Horizontal supply Horizontal extract Top entry supply Top entry extract M Spigot mounted perforated steel trimming damper, adjustable through front face (types...-zh / AH only) The type AK plenum box comprises a casing with horizontal circular spigot for duct connection, with or without spigot mounted perforated trimming damper (...-M) Optional 12mm thick black faced, Class 'O' internal lining (... -D) is available on all AKV-ALSP plenums. Materials The plenum box is made from galvanised sheet steel, and is supplied self-finish. Plenums are manufactured with a 15mm internally formed flange at each end, with factory fitted foam seal. AK....- ZH /...-AH O/A LENGTH ('L' - 5) MAX LENGTH ('L' = 2100) 15,0 'W' O/S 'Eb' O/A HEIGHT 'D' + 22,0 EXTENSION 'A' 700,0 Max. 'D' DIA SPIGOT 76,0 'B' I/S 100,0 ('D' + A + 22) O/S REF 'LN' ACTIVE LENGTH ('L' - 35,0) 15,0 'W' O/S 'D' DIA SPIGOT Grille ALSP20-1 Slot ALSP20-2 Slot ALSP20-3 Slot ALSP20-4 Slot 'W' 138,0 176,0 214,0 254,0 Multiple Spigots Dimensions 'B' 53,5 93,0 'Eb' 'D'+'A'+122 'D'+'A'+122 132,5 'D'+'A'+122 172,0 'D'+'A'+122 Spig. Ø ZV / AV Ø123 Ø158 Ø198 Ø198 Grille ALSP25-1 Slot ALSP25-2 Slot ALSP25-3 Slot ALSP25-4 Slot 'W' 138,0 214,0 254,0 310,0 Dimensions 'B' 58,5 103,0 147,5 'Eb' 'D'+'A'+122 'D'+'A'+122 'D'+'A'+122 192,0 'D'+'A'+122 Spig. Ø ZV / AV Ø123 Ø158 Ø198 Ø248 76,0 'B' I/S 100,0 (200) O/S REF = L1 / 2 = = L1 / 3 L1 / 3 = = L1 / 4 L1 / 4 L1 / 4 = 7

Installation Instructions Preparing the plasterboard aperture Installation of TROX Plaster in Grilles requires an aperture in the plasterboard to be created large enough for the neck of the grille to clear. The minimum opening size for the plasterboard aperture should be based on the specified grille type and nominal size (refer to project schedule for unit sizes). Minimum opening sizes relating to the nominal grille size are detailed on pages 3, 4 & 6 of this technical leaflet. Behind the plasterboard, a sturdy timber batten frame is to be provided (by others) to match the opening size within the plasterboard. The minimum combined construction depth for plasterbord & batten should be between 40mm up to a maximum of 60mm. Installing TROX AK plenum boxes Provision should be made to suspend the supply or return air plenum boxes (if specified) behind the plaster board / timber frame in such a way that no weight from the plenum is transferred to the grille border. Each AK plenum box is to be installed using suitable threaded rod or wire supports (by others) to take the weight of the plenum. IMPORTANT; To ensure a good seal against the diffuser face, the edge of the plenum should sit square within the opening and flush with the unfinished plasterboard face. Construction Vertical section Plasterboard (by others) Timber Batten (by others) Plenum neck flush with plasterboard face (pre-plaster skim) Plenum supports (By others) MIN Plasterboard Opening AHP / WAPP / ADMP ('H' - 4 / 'L' - 4) ALSP ('A' + 18 / 'L' + 38) MIN Depth 40mm MAX Depth 60mm 8

Installation Instructions Installing the blanking plate Where optional blanking plates have been supplied, these must be fitted to the rear of the grille before the grille is installed into the builders work opening as it is not possible to install these once the grille is in situ. To determine the location for the blanking plates, offer up the grille to the builders work opening and mark on the plaster flange using removable tape, the area where supply or return plenums are not installed and where return air through the grille is not required. IMPORTANT; Ensure that the blanking plate installation does not cover any active area of the grille as this will restrict the flow of air through the grille. Remove the grille from the opening and place face down on a suitable protected work surface, ensuring the area is free from debris to avoid damaging the painted surface. Blanking plates and foam insulation are supplied loose, in lengths for site cutting and installation to the rear of the grille neck. Cut the blanking plate and foam insulation to the required length(s) to cover the areas marked as non-active, ensuring edges are clean and burr free. To install the blanking plate/tray to the grille neck; AHP / ADMP: Lay the foam insulation into the grille neck with backing facing away from the grille face. Insert the straight edge of the blanking plate into the channel on the rear of the grille neck and gently lever the tabs into the channel on the opposite side to engage the blanking plate. ALSP: With the foam insulation cut to the correct size to match the blanking tray, carefully peal off the self-adhesive backing and stick the foam insulation to the inside of the blanking tray. Place the blanking tray over the neck of the diffuser and secure into position using No. 8 self drilling screws (supplied by others) through the pre-formed Ø3.5 holes provided within the blanking tray along both sides. AHP, ADMP & ALSP: Once the blanking plate/tray is installed in the correct position, apply a continuous bead of mastic to the joint between the blanking plate and the channel on both sides to prevent vibration. Repeat these steps for each section of blanking plate until all nonactive sections of the grille are blanked. 9

Installation Instructions Installing the grille (Finite) The plaster in grille, complete with core, should be installed into the builders work opening, retaining the plastic film on the front of the grille core to prevent marks during the installation. IMPORTANT; The grille core can only be installed within the border in one orientation. Ensure correct orientation of the air blades before final screw fixing into plasterboard opening. Ensure the grille border is flat and level before fixing it in place then secure using counter sunk head 3.5 drywall screws every 300mm. Screw through the holes in the border, through the plaster board and into the timber batten behind. Ensure the screw heads are driven firmly into the border and sit below the top edge of the grille border so they will not visible when the border is plastered. The border should be firm with no movement. Jointing tape should be applied over the plaster frame to provide a good adhesion surface for the plaster skim. IMPORTANT; Care should be taken not to stretch the grille border apart during the installation as this may affect core retainment. With the grille secured in the plaster board panel, remove the grille core (refer to page 11 for details on AHP & ADMP core removal) and store in a safe place, clearly marked with the location reference to avoid accidental damage or disposal. IMPORTANT; Mitred corners (if supplied), along with ALSP plaster in slot diffusers are fitted with non-removable cores therefore suitable site masking of the grille core is required to prevent damage. The plaster can then be applied using the top edge of the grille border to level the plaster. Excess plaster should be cleaned off the inside of the grille & border before it dries to avoid staining or damage to the paint finish. Installing the grille (Linear) Linear grilles will be supplied with alignment pins and a blade alignment fixture (AHP & ADMP). The alignment fixture is supplied flat and should be formed by hand before installation. Before installing the grille border into the builders work opening, arrange the grille sections next to each other on a clean, level surface with the alignment pins and blade allignment fixture to hand to ensure a good fit prior to installation. Blade alignment fixture Insert the alignment pins halfway into the alignment ports located in the border extrusion on one grille section. Insert the formed blade allignment fixture into the extrusion channel at the rear of grille border. IMPORTANT; Install the allignment fixture with the grille installed within the border to ensure correct orientation. The grille border sections can then be offered up to the plaster board aperture and installed in the same manner as the finite grilles detailed above, ensuring both allignment pins and blade allignment fixture are correctly installed between each section. Once the grille border has been secured in place, remove the core (refer to page 11 for details on AHP & ADMP core removal) and centre the blade alignment fixture between the two sections. Mastic should be applied to the top and bottom of the blade allignment fixture where it meets the border extrusion to prevent movement or vibration. Alignment pin Store the grille core sections in a safe place, clearly marked with the specific location reference to avoid accidental damage or disposal and to ensure correct core is re-installed within the relevant border section. IMPORTANT; Each core section is specific to an individual border section. 10

Installation Instructions Removing the grille core (AHP) AHP plaster in grille is supplied with a removable cores for access to supply or return air plenums or volume control dampers (if specified). The AHP core is retained within the border using friction bungs installed at the top and bottom of the grille core support tubes. To remove the grille core, use a suitable hook tool (supplied by others) to gently pull the top blade away from the border at both ends of the grille. IMPORTANT; Removal of the grille core from the border is a 2 person operation. Do not attempt to remove the grille core as a single person operation as this can cause damage to the grille or plasterwork finish. Care should be taken when removing the grille core for the first time as the safety wire restraints will not be fitted. When removing the grille core, excessive force can result in damage to the plaster finish surrounding the grille border. Installing the grille core (AHP) Once the plaster/ paint finish is properly dry, unwrap the grille core and safety wires ready for assembly. 2 No. safety wires are included in a bag supplied with each grille core section. Before installing the grille core, safety wires must be clipped to the pre-formed holes provided at each end of each grille core. The holes are located on the top blade, approximately 50mm in from each end blade support tube. For grilles with 15 angle blades, holes are provided in top and bottom blades to allow core roation and airflow direction control. Care should be taken when installing the core to ensure correct blade orientation. Disengage the clasp at the end of the safety wire, prise open the clasp and thread through the pre-formed hole within the grille core. Ensure the clasp is correctly reengaged once installed (refer to photo). Repeat this process at each end of the grille core. Open the clasp at the free end of each safety wire and prise open, ready for the final assembly to the grille border. Safety wires IMPORTANT; Installation of the grille core into the border is a 2 person operation. Do not attempt to fit the grille core as a single person operation as this can cause damage to the grille or plasterwork finish. IMPORTANT; The grille core must be supported with the blade containing the preformed hole at the top (refer to photo) and the finished grille face towards the operative (pre-fored hole will be at the back of the blade). With one operative supporting the grille core directly below the border, another operative can carefully loop the safety wire around the corresponding mullion within the border and thread the open clasp back through the pre-formed hole within the grille border. Ensure the clasp is correctly re-engaged once through. Once both wires are attached at both ends, the grille core can be offered in to the grille border. The grille core should be lifted upwards until the core is level with the opening before gently pushing the core into the border Mullion The grille core should be carefully pushed into the border ensuring even pressure along the entire length of the grille. Each grille section should be visually inspected once installed to ensure the grille core is flush with the border profile. Any areas where the grille core does not sit flush should be inspected. 11

Installation Instructions Removing the grille core (ADMP) ADMP plaster in grille is supplied with removable cores for access to supply or return air plenums or volume control dampers (if specified). The ADMP core is retained within the border using spring clips, captured within support mullions spaced along the length of the grille core. IMPORTANT; Removal of the grille core from the border is a 2 person operation. Do not attempt to remove the grille core as a single person operation as this can cause damage to the grille or plasterwork finish. Mullion Spring Clip To remove the grille core, first locate the spring clips by looking into the grille through the air discharge slots. Using a suitable non-abrasive pry tool (non-metallic), hook the grille support tubes and gently pull the core away from the border, supporting the weight of the core. Care should be taken when removing the grille core for the first time as the safety wire restraints will not be fitted. When removing the grille core, excessive force can result in damage to the plaster finish surrounding the grille border. Ensure support is provided along the entire length of the grille core to avoid damage to the grille or plaster finish. Installing the grille core (ADMP) Once the plaster/ paint finish is properly dry, unwrap the grille core and safety wires ready for assembly. 2 No. safety wires are included in a bag supplied with each grille core section. Before installing the grille core, the safety wires must be attached to the pre-formed holes provided at each end of the grille core. The holes are located on the bottom blade, approximatley 50mm in from each end support tube. Disengage the clasp at the end of the safety wire, prise open the clasp and thread through the pre-formed hole within the grille core. Ensure the clasp is correctly re-engaged once installed (refer to photo). Repeat this process at each end of the grille core. Open the clasp at the free end of each safety wire and prise open, ready for the final assembly to the grille border. IMPORTANT; Installation of the grille core into the border is a 2 person operation. Do not attempt to fit the grille core as a single person operation as this can cause damage to the grille or plasterwork finish. Mullion IMPORTANT; The grille core must be supported with the blade containing the pre-formed hole at the top and the finished grille face pointing away from the border opening. IMPORTANT; The grille core can only be installed within the border in one orientation. Ensure correct orientation of the air blades before final installation into the grille border. With one operative supporting the grille core directly below the border, another operative can carefully loop the safety wire around the corresponding mullion within the border and thread the open clasp back through the pre-formed hole within the grille border. Ensure the clasp is correctly re-engaged once through. Once both wires are attached at both ends, the grille core can be offered in to the grille border. The grille core should be rolled upwards into the opening ensuring the core is correctly engaged within the mullion retaining lips. Mullion Retaining Lip Carefully push the core into the border ensuring that the grille tubes allign with the spring clips fixed to border mullions. IMPORTANT; Ensure grille is secured along the full length and that all spring clips are fully engaged around the grille support tubes using a torch if necessary. Spring Clip 12

Order Details Plaster In Liner Grilles (AHP, WAPP, ADMP) F - AHP-15 / 1500 x 150 / P3 / RAL 9010:20% - Linear Construction F Finite Construction E End Section M Middle Section L x H (see page 3 & 4) A1 P0 Mill Finish Aluminium 9010:50% (white) Grille AHP-0 AHP-15 WAPP-0 WAPP-15 ADMP-1 P2 P3 P4 9006:25% (silver grey) Standard Finish 9010:20% (white) 9005:20% (black) TEZEU EXAMPLE Make: TROX : F-AHP-15 / 1500 x 150 / P3 / RAL9010:20% P6 Special Finish State colour RAL..., BS... Gloss level...% Blanking Plate UKBP-AHP / 1000 x 150 / D / P4 / RAL9005:20% Grille AHP (covers WAPP) ADMP L x H (see page 3) P0 9010:50% (white) Foam Lining - Not Lined D 12mm Foam Lining (supplied loose) P2 P3 9006:25% (silver grey) 9010:20% (white) TEZEU EXAMPLE Make: TROX : UKBP-AHP / 1000 x 150 / D / P4 P4 P6 Standard Finish 9005:20% (black) Special Finish State colour RAL..., BS... Gloss level...% 13

Order Details AK-P Plenums (AHP, WAPP, ADMP) AK-G-P - ZH - D - DG / 900 x 150 x 198 x 1 AK-G-P Plenum ZH Horizontal spigot (supply) AH Horizontal spigot (extract) ZV Vertical spigot (supply) AV Vertical spigot (extract) Internal Lining 0 No lining. D 12mm foam lining. L x H (see page 5) Spigot Quantity Spigot Diameter Plenum Damper 0 No Damper. AG Opposed blade damper fitted within plenum. D Individually adjustable air pattern control blades fitted within plenum. DG Opposed blade damper as...-ag plus a set of individually adjustable air pattern control blades fitted within plenum. EXAMPLE Make: TROX : AK-G-P - ZH - D - DG / 900 x 150 x 198 x 1 Plaster In Slot Diffuser (ALSP) F - ALS25P - T2-2 / 1800 / P3 / RAL 9010:20% - Linear Construction F Finite Construction E End Section M Middle Section Diffuser Length (mm) A1 P0 Mill Finish Aluminium 9010:50% (white) Grille ALS20P ALS25P Internal Style S Return (without blades) NA Non-active (without blades) T2 2 blades with spreader plate No. of Slots ALS20P Slots 1-4 ALS25P Slots 1-4 P2 P3 P4 9006:25% (silver grey) Standard Finish 9010:20% (white) 9005:20% (black) TEZEU P6 Special Finish State colour RAL..., BS... Gloss level...% EXAMPLE Make: TROX : F-ALS25P - T2-2 / 1800 / P3 14

Order Details ALSP Blanking Plate UKBP-ALS25 / 2 / 1800 / D / P4 / RAL9005:20% Grille ALS20 ALS25 No. of Slots Foam Lining - Not Lined D 12mm Foam Lining (supplied loose) EXAMPLE Make: TROX : UKBP-ALS25 / 2 / 1800 / D AK-ALSP Plenums AK-ALS25P - 2 - ZH - D - M / 1200 x 198 x 2 x 320 AK-ALS20P AK-ALS25P No. of Slots Length (mm) 1) Overall Height including diffuser plus any neck extension Plenum ZH Horizontal spigot (supply) AH Horizontal spigot (extract) ZV Vertical spigot (supply) AV Vertical spigot (extract) Internal Lining 0 No lining. D 12mm foam lining. EXAMPLE Make: TROX : AK-ALS25P - 2 - ZH - D - M / 1200 x 198 x 2 x 320 Spigot Diameter Plenum Damper 0 No Damper. M Spigot Damper. No. of Slots NOTE: 1) Overall height (including diffuser height) = Spigot Dia. + 122 + Extension 'A' Subject to change All rights reserved TROX UK (08/2016) 15