Safety. matters. CryoMACS Products



Similar documents
Cord Blood Collection, Processing and Freezing Bag Sets for the Cryopreservation of Blood and Cellular Components

14.0 Stem Cell Laboratory Services

HEALTHCARE Single - Use Systems CONTRACT MANUFACTURING SOLUTIONS PARTNER

Guidance for Industry

Processing Cord Blood With the SynGenX System

Hippocrates, Cords and Quality

Corning Flexible Packaging Systems. Bioprocess Containers, Tank Liners, Tubing Sets and Custom Assembly Services

or

Thermo Scientific Nunc Products for InVitro Fertilization. security, safety and reproducibility. for your valuable. samples

Thermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment

Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-

, 38F,

Family Cord Blood Stem Cells Bank

Packaging Validation according to ISO 11607

Screw Cap Micro Tubes

EU GMP Annex 1 Update 2008: Airborne Particle Counting

The essential choice in cell processing

Quick guide: using CTE security straws for cryopreservation of pronuclear stages, embryos and sperm

Precision injection moulding

Comparability of Cord Blood Units

Bio Deutschland CEO & CFO-Meeting 29. November Unternehmertum in den Life Sciences am Beispiel der Geschichte von Miltenyi Biotec

CHAPTER 3 COLLECTION PROCEDURES

Sampling Solutions. Fuel and Lube Oil sampling Equipment. Convenient, Representative, Approved.

Liquids Suspensions Gels

How single-use connections advance aseptic processing: Increased process flexibility and reliability, reduced costs

Assembly and Installation Procedures

Human Umbilical Cord-derived Multipotent Mesenchymal Stromal Cells (huc-msc) Handling Instructions

BioArchive Freezing Curve for Cord Blood

Cleaning validation of cleanrooms and preparation equipments

Sterile Cleanroom Management

TEMPERATURE SENSORS AND PROBES FOR BIO-MEDICAL APPLICATIONS

THE BASICS OF PACKAGING

Barcode Labeling in the Lab Closing the Loop of Patient Safety

GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS

Particle testing in cleanroom high-pressure gas lines to ISO made easy with the MET ONE 3400 gas calibrations

Caring for a Tenckhoff Catheter

Climate chamber with illumination

NALCO WT-1000 Closed System Corrosion Inhibitor

Liquid II Cell Culture Media Manufacturing Plant. Overview Facilities Water for Injection Sterile Environment Media Handling Cleanroom Interior

EUROTUBO DELTALAB 4. PETRI DISHES AND LOOPS

laboratory glass bottles and screw caps

Cord Blood: Thawing & Infusion Practical Methods

Single-Use Flow-Through Cell ph FTC-SU-HP8

Hematopoiesis i starts from. HPC differentiates t to sequentially more mature. HPC circulate in very low

Design, Operation and Management of GTP/GMP Cell Engineering Facilities

Gravity Bag Cord Blood Collection Method Training Manual

HARVESTING AND CRYOPRESERVATION OF HUMAN EMBRYONIC STEM CELLS (hescs)

Helping to protect you from exposure to hazardous drugs

Cellartis Protocol Culturing of hes Cells

Overcoming Challenges in the Manufacturing of Pre-Filled Syringes. Farvea, a new comer in the PFS world PFS Tech June 2016 pharma@fareva.

Microbiological Evaluation of the STI Series 2000 Medical Waste Treatment Process

Family Link Cord Blood Storage Program

USP CLASS VI GASKETS PRODUCTS OF INTEGRITY...FROM PEOPLE OF INTEGRITY

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use

Standard Operating Procedure (SOP) Work Package 8. Sample Collection and Storage

Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-


C 5. chemical development contract research custom synthesis cgmp API manufacturing commercial production. Welcome to

Particle Monitoring Requirements in Pharmaceutical Cleanrooms

Public Cord Blood Banking at the National Cord Blood Program (NCBP)

WHITE PAPER April 18, 2016

(800) Cryo-Cell.com

CORD BLOOD BANKING FAQ

PQS performance specification

Disposables the Original by B. Braun

World Class Equipment worldwide Edition J

Federal Wage System Job Grading Standard For Laboratory Working, Table of Contents

Recommendations to Transplant Centres Performing Cord Blood Transplants. Why Choosing the Right Thaw Method Could Save a Patient s Life

Cryopreservation of Umbilical Cord Tissue for Stem Cell Harvesting Executive Summary Figure 1. Cross section of normal umbilical cord.

Total Aerobic Bacteria, Yeasts and Molds

Medical aids for 1 colon diagnostics PRODUCT CATALOG

Cleanroom. For. Sterile Manufacturing Facilities

VALIDATION AND QUALIFICATION

KGI MEDICAL WASTE MANAGEMENT PLAN

Sterilization methods and equipment Lab 1-2

Cyto-Set. Safer cytostatic preparation and application. IV Administration

How To Safely Infuse Aupbsc

Aseptic preparations, including TPN, for a limited number of patients

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

Case Study Neubau einer Parenteralia Fabrik 3. GMP-Forum, Kirchzarten 28. September 2012, Basel. Philip Schneider, F.

ISO A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners

Guidance on safe use of Autoclaves

syriq Glass Prefillable Syringes

Transport and Mailing Systems

Guidelines for Collection, Processing, and Storage of Cord Blood Stem Cells Second Edition March 2003

Kinematic viscometers in accordance with ISO 3105, DIN 51562, ASTM D445 For automatic and manual viscosity measuring Greatest precision and durability

Washing. Sterilising. Filling. Closing. Inspecting. Labelling

Tablet Packaging Safety

TESTIMONIAL: Congratulations! Our company s EID Incoming Inspection of AMRESCO-provided products

CHAPTER 5 SHIPPING PROCEDURES

Mycoplasma Testing Products & Services. M-175 CELLshipper Mycoplasma Detection Kit (In-house sample preparation and slide fixation)

James M. Pleasants Company

Public Cord Blood Bank

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

Human Umbilical Cord Blood CD34 + Progenitor Cell Care Manual

AATB/ICCBBA Interim Guidance Document. For use of ISBT 128 by North American Tissue Banks

Tabletop Line. Automatic and Semi-Automatic Autoclave Series

Future Health Technologies. From Academia to Industry The Stem Cell Challenge. Roger J. Dainty MBE FIScT UK Managing Director

Building Owners Guide to a Duro-Last System!

Transcription:

Safety matters CryoMACS Products

CryoMACS Freezing Bags The right step towards safe more cryopreservation safety in cryopreserv Overwrap bag protects both sample and freezing bag during cryopreservation. Made of the same resistant tubular ethylene vinyl acetate (EVA) material as the freezing bag. Provided with each freezing bag. Space-saving shape enables compatibility with existing freezing cassettes. Ribbed structured material facilitates opening of overwrap bag and introduction of freezing bag. Integrated filling assembly with Injection port, two female Luer-Lock connectors, one male Luer-Lock connector, and roller clamps for high flexibility. The extra-long PVC tubing is compatible with sterile connecting devices. Optimized Y-adaptor with combined Luer-Lock injection port.

ation Hanger holes for easy handling of the bag. Advanced bag design enables full drainage of the bag. Freezing bag made of a resistant tubular EVA film with fewer welds for more durability and less storage space. Label pouch for written sample information and to ensure label integrity throughout the freeze-thaw cycle. Two secure spike ports for removal of the thawed cell product. The single-component ports are secured with sealed, twist-off protective caps. Internal protection tubes inhibit perforation of the freezing bag during removal of the cell product. Extra-long EVA tubing enables sampling for quality control by simple heat-sealing of sample-filled tubing sections.

CryoMACS Freezing Bags Safety to rely on Make assurance double sure CryoMACS Freezing Bags consist of a freezing bag and a corresponding overwrap bag. Both bags are made of EVA The overwrap bag provides extra security by protecting the freezing bag and the stored cellular product, while maintaining sterility and preventing contamination risks during storage. 1, 2 Single sterile packaging for convenient handling Each CryoMACS Bag, including freezing bag and corresponding overwrap bag, is individually packed and sterilized by electron-beam irradiation. The outer packaging can be disinfected for easy clean -room handling. This helps to maintain a sterile workflow from cell collection to storage and subsequent thawing. Advanced bag design The CryoMACS Freezing Bags are made of an EVA tubular film with few welds for high durability. The design is optimized for complete drainage of the bags. The extralong EVA tubing of the integrated filling assembly allows the user to prepare small samples for quality controls: simple heat sealing can separate filled tube sections. The spike ports are secured with sealed twist-off protective caps to prevent cross-contamination. The spike ports internal protection tube inhibits perforation of the freezing bag during removal of the thawed cell product. References 1. Tedder, R et al. (1995) Lancet 346: 137 140. 2. Fountain, D et al. (1997) Transfusion 37:585 591.

Make Designed assurance for safer double cryopreservation sure (some more text please CryoMACS Unique bag Freezing concept Bags with consist few welds of a freezing making bag it highly and a corresponding durable overwrap bag. Both bags are made of EVA (ethylene vinyl acetate). The overwrap bag provides extra Corresponding overwrap bag to protect freezing bag security by protecting the freezing bag and the stored and stored product cellular product, while maintaining sterility and preventing contamination Optimized shape risks and during spike storage.1, ports for 2 complete some more text please drainage of the freezing bag Single, sterile packaging helps to maintain aseptic workflow More protection in the same storage space

CryoMACS Freezing Bags Developed by specialists, used by experts Robustness of the CryoMACS Freezing Bags for routine clinical use has been shown in a number of internal and external tests. The integrity of CryoMACS Freezing Bags after filling and exposure to ten cycles of freezing and thawing has been demonstrated in a series of laboratory experiments. Results of the freeze-thaw bag integrity test Bag designation Fill volume Number of test failures Failure at indicated cycle number CryoMACS Freezing 120 ml 2/90 9, 9 Bag 750 CryoMACS Freezing 150 ml 0/10 Bag 750 Manufacturer A 750 150 ml 3/10 3, 4, 6 CryoMACS Freezing 20 ml 0/100 Bag 50 Manufacturer A 50 20 ml 0/20 One hundred CryoMACS Freezing Bags 750 and ten 750 ml reference bags were filled and exposed to ten consecutive cycles of freezing and thawing. One hundred CryoMACS Freezing Bags 50 and twenty 50 ml reference bags were also tested. The results of all freezing tests are summarized here: 2 out of 100 (2%) of the 750 ml CryoMACS Freezing Bags developed leaks at very late stages 3 out of 10 (30%) of the reference bags failed the integrity test at early stages all 50 ml freezing bags passed the integrity test

CryoMACS Freezing Bags have been shown to be impermeable to microorganisms in accordance with the requirements of ISO ISO 3826-1* The advanced bag design of the CryoMACS Freezing Bags (e.g. secured spike ports, appropriate overwrap bags) helps avoid viral contamination during use.* Several external test series concluded that CryoMACS Freezing Bags are suitable for introduction into routine clinical use and clean-room processing. 1 A comparative study showed that the CryoMACS Freezing Bags fulfill the requirements of a cryogenic freezing bag for the cryopreservation of human progenitor cells for transplantation. 2 *Reprints of these technical reports of tests performed in-house are available on request. References 1. Ings, S.J. et al. (2009) Cytotherapy 11:10. 2. Sputtek, A. et al. (2011) Cytotherapy 13: 481 489.

CryoMACS Freezing Bags Safety matters The CryoMACS Freezing Bags are intended for a single cycle of freezing, storage (down to 196 C), and subsequent thawing (at +37 C) of hematopoietic progenitor cells. Developed with the customer CryoMACS Freezing Bags have been developed in cooperation with our clients and showed excellent standards for cryopreservation. Proven quality The freezing bags and their corresponding overwrap bags are made of EVA, a durable material that has been used for 30 years in liquid nitrogen cryopreservation procedures. Different applications, different sizes A useful range of CryoMACS Freezing Bags with nominal volumes ranging from 50 to 1000 ml (recommended fill volumes from 10 to 270 ml) is available and offers flexibility for various applications.

Order no. Product Nominal volume 200-074-400 CryoMACS Freezing Bag 50 200-074-401 CryoMACS Freezing Bag 250 200-074-402 CryoMACS Freezing Bag 500 200-074-403 CryoMACS Freezing Bag 750 200-074-404 CryoMACS Freezing Bag 1000 Recommended fill volume 50 ml 10 20 ml 250 ml 30 70 ml 500 ml 55 100 ml 750 ml 80 190 ml 1000 ml 125 270 ml The CryoMACS Freezing Bags are manufactured by Miltenyi Biotec GmbH and controlled under an ISO13485 certified quality system. These products are available in Europe as CE-marked medical devices and are marketed in the USA under FDA 510(k) clearance. For availability in your country, please contact your local sales representative.

CryoMACS DMSO 10 (EP, USP) Tested and certified quality CryoMACS DMSO 10 (EP, USP) is a high quality, pure and sterile dimethyl sulfoxide, supplied in glass vials. DMSO is a well established and commonly used cryoprotective agent. It protects cells during controlled freezing and storage at cryogenic temperatures. CryoMACS DMSO is manufactured and tested under a certified ISO 9001 quality system and in compliance with relevant GMP guidelines. Each batch of CryoMACS DMSO 10 (EP, USP) is tested according to the European Pharmacopoeia (EP) and to the United States Pharmacopoeia (USP) and comes with a detailed batch-specific certificate. CryoMACS DMSO 10 (EP, USP) is for research use and ex vivo cell culture processing only, and is not intended for human in vivo applications.

Order no. Product Components 170-076-303 CryoMACS DMSO 10 (EP, USP) 24 10 ml glass vials CryoMACS DMSO is manufactured and tested under a certified ISO 9001 quality system and in compliance with relevant GMP guidelines. CryoMACS DMSO is for research use and ex vivo cell culture processing only, and is not intended for human in vivo applications. For regulatory status in the USA, please contact your local representative.

cryomacs.com Miltenyi Biotec GmbH Friedrich-Ebert-Straße 68 51429 Bergisch Gladbach Germany Phone +49 2204 8306-0 Fax +49 2204 85197 macs@miltenyibiotec.com www.miltenyibiotec.com Miltenyi Biotec provides products and services worldwide. Visit www.miltenyibiotec.com/local to find your nearest Miltenyi Biotec contact. 130-094-484.03