Installation handbook. AutroBeam 25 Beam detector



Similar documents
Interactive Fire Alarm System

FIRERAY 2000 Installation Guide

Fire Alarm Control Panel BS-60

FIREDEX Conventional Fire Panels

W150: Miniature photoelectric switch series with completely integrated electronics

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Cross-beam scanning system to detect slim objects. 100 mm in

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

Installation & User Instructions

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Installation Handbook. Interactive Fire Alarm System Release 3. Repeater Panel BU-320 / Information Panel BV-320

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

LUT Luminescence scanners: Seeing what no-one else can

DLO1191 Linear smoke detector

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

ACS-30-EU-EMDR-10-MOD

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Laserlyte-Flex Alignment System

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Smoke exhaust systems

Industrial infrared heater IR For premises with large volumes and high ceilings

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

intelligent solutions

2013 Wireless Video Intercom INSTALLATION GUIDE

W 36: Mastering complex tasks reliably

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Radiant Temperature Sensor TY7321

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

New XUY roller sensors

E-PDD Duct Smoke Detector Installation Sheet

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Passive Infrared Motion Detector 5420/90. Installation Instructions

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

FIRE DETECTORS LIMITED XP95 BEAM DETECTOR INSTALLATION GUIDE

IS3016A Passive Infrared Motion Sensor with Anti-Mask - Installation Instructions

Installation and Operation Manual

Analogue addressable devices

Contents. Document information

AX-100TFR/AX-200 TFR INSTALLATION INSTRUCTIONS INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR.

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01


D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

K17.12 Door closers K17. Doors

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

GREISINGER electronic GmbH

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Linear Luminaire with LED Series EXLUX 6402/2

ABB Drives. User s Manual HTL Encoder Interface FEN-31

DCS Input/Output Relay Card Series

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

PS 155 WIRELESS INTERCOM USER MANUAL

EBDSPIR-PRM, EBDSPIR-PRM-IP

Input module, input/output module

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

HART HSSD High Sensitivity Smoke Detection

Single Channel Loop Detector

ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

DCP Fan Controller. Version 01/2009. The engineer s choice

Drayton Digistat +2RF/+3RF

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

12 Volt 30 Amp Digital Solar Charge Controller

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

HERZ-Thermal Actuators

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Actuator for modulating control AME 435

Day / Night IR Color Camera User Manual V2.1.0

Triple Waveband Infra-Red Flame Detection

2M IR Mini Dome Quick Installation Guide

Color Mark Sensor with Red or Green LED E3S-VS

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

Setup guide. point to point wall plate extenders

CB200W Water Leak Detection Panel Application Guide

Digital input modules

SMART SENSOR COLLECTION

Transcription:

AutroBeam Autrobeam 5 Installation handbook AutroBeam 5 Beam detector P-AB5/DE - Rev. C Autronica Fire and Security AS Fire and Security, Trondheim, Norway. Phone: + 47 73 58 5 00, fax: + 47 73 58 5 01. Oil & Gas, Stavanger, Norway. Phone: + 47 51 84 09 00, fax: + 47 51 84 09 99. Autronica Industrial Ltd., Watford, United Kingdom. Phone: 193 3 37 68, fax: 193 55 77. Visit Autronica Fire and Security s Web site: www.autronicafire.com - P-AB5/DE - Rev. C, 99015 1 Autronica AS

AutroBeam 5 1 System AutroBeam 5 is an infrared beam detector designed for monitoring areas from 1,5 to 5 m. The AutroBeam 5 system comprises a transmitter (Tx) and a receiver (Rx), mounted in the same housing, and a reflector plate installed at the opposite end of the area to be monitored. AutroBeam 5 detects the presence of smoke in 3 ways. Reduction of visibility, the development of a special frequency spectrum by smoke and the time-factor for reduced visibility. AutroBeam 5 and reflector can be fixed direct to a wall or mounted on a adjustable bracket. P-AB5/DE - Rev. C, 99015 Autronica AS

Installation of Autrobeam 5.1 Fixing direct to a wall - Remove the front cover from the detector unit. - Prepare the fixing holes (x and y) on the rear of the unit. - Fix the detector to the wall using x4 mm screws. - After fixing, replace the front cover. Make sure that the light aperture in the lens filter is in front of the LED indicator. 15mm x x, y = Ø 4mm Fig.no. 1 y. Mounting on adjustable bracket type 5861-0.1001 - Remove the front cover from the detector unit. - Prepare the fixing holes (x and y) on the rear of the unit. - Fix the bracket to the detector using x (M4x10mm) screws. - After fixing, replace the front cover. Make sure that the light aperture in the lens filter is in front of the LED indicator. - Adjust the angle of the detector by using an Allan key. Fig.no..3 Positioning and alignment - Mount AutroBeam 5 in a suitable place in the area to be monitored. - Align the unit in the general direction of where the reflector is to be mounted. P-AB5/DE - Rev. C, 99015 3 Autronica AS

.4 Connection Cable aperture L1 + - NO C NC NO C NC 1 3 4 5 6 7 8 } 4V d.c. Socket terminals Fig.no. 3 Green LED SW1 Sensitivity adjust Red LED Yellow LED Trimming J1 Normal Inverted J1 Fig.no. 4 - Set jumper J1 to position "Inverted". - Remove the female contact from the terminals (L1). - Feed the cable through the aperture (on the right-hand side of the detector), and connect the wiring to the plugs. - Connect 4V d.c. to terminals 1(+) and (-). - Connect a KΩ end load or terminal connector (BXY-40) between points 4(+) and 7. (See fig.no. 5). - Connect terminals 3 and 6 together. - Connect the output from the address unit (BN-35/N) or the loop output (BX-40) to terminals 3 and 4(+). L1 Addressable control panel (BS-100/60) Conventional control panel Address unit BN-35/N BX-40 5 6 + Fig.no. 5 - + 1 3 4 5 6 7 8 + - } 4V d.c. NO C NC NO C NC R R=KΩ for connecting to the address unit. R=end load BXY-40 for connecting to conventional fire alarm control panel BX-40. Alarm relay: pkt. 3, 4 og 5. Fault relay: pkt. 6, 7 og 8. With jumper J1 set to "inverted" position, the fault output will activate on loss of supply power. With jumper J1 set to "normal" position, the fault output will not be activated on power loss. If "normal" position is chosen, then terminal 3 and 8 must be connected together (not 3 and 6 as described above). P-AB5/DE - Rev. C, 99015 4 Autronica AS

.5 Connecting to different fire alarm panels - BS-100: See diagram BS-1031 - BS-60: See diagram BS-103 - BX-40: See diagram BX-313 3 Power supply and adjustment 1. Green LED: "Power on". A. Turn-switch for selecting sensitivity of receiver. Red LED: Indicates alarm. 3. Yellow LED: Indicates fault. B. For trimming of infrared level. Receiver (Rx) Transmitter (Tx) Fig.no. 6 3.1 Adjust transmitter (Tx) to maximum infrared level by turning the potentiometer screw (B) to its limit in a clockwise direction (0 turns). 3. Connecting power - Ensure that the voltage is correct (4V d.c.). - Connect 4V d.c. to terminals 1(+) and (see fig.no. 4). - Green LED-1 (power on) and yellow LED- (fault) will be on. P-AB5/DE - Rev. C, 99015 5 Autronica AS

3.3 Mounting the reflector - Move the reflector in a horizontal and vertical plane within the area where the reflector is to be mounted and observe if the yellow LED (3) begins to flash. - Yellow LED (3) flashes when the reflector is within the diameter of the infrared beam. The diameter of the beam is about 60 cm at a distance of 5 m, and it diminishes proportinally in towards the detector. - If moving the position of the reflector within the intended area does not result in the yellow LED (3) flashing, the reflector must be fixed temporarily. - Re-align the detector (Tx/Rx) until the yellow LED (3) starts to flash. The reflector is now within the diameter of the beam. - Move the reflector (up, down, to the right and left) and mark off the limits where the yellow LED (3) goes out. Position the reflector in the centre. A Reflector B Infrared beam Max.60cm Correct Fig.no. 7 Incorrect - The reflector is now positioned correctly and the yellow LED should be flashing. 3.4 Fine-tuning of the infrared beam - Turn the potentiometer screw (B) anticlockwise until the yellow LED (3) goes out. Ensure that the receiver (Rx) is not obstructed in any way (e.g. by your head or hand). - Block the infrared beam by holding a finger in front of the transmitter (small lens) and check that the yellow LED (3) comes on, and that it goes out when the obstruction is removed. - If the yellow LED starts to flash after removing the obstruction, the infrared level is still too powerful. Re-adjust the potentiometer slightly and repeat the blocking procedure until the desired result is obtained. This procedure should be repeated -3 times to achieve optimal adjustment. - If the red alarm LED () lights up/starts to flash, the detector must be reset. This is done by cutting the 4 V DC power supply to the detector. P-AB5/DE - Rev. C, 99015 6 Autronica AS

- When the infrared beam is blocked, the yellow LED (3) will light up and an error output generated. If this condition is not achieved, then the following may occur: a) Yellow LED flashes again. b) Yellow LED stops flashing and blocking/unblocking of reflector has no effect. c) Yellow LED lights up constantly. In each case, either the detector/reflector is wrongly aligned, or the infrared beam is being reflected from a shiny surface (glass, metal, etc.). 3.5 Signal level - When yellow LED is out, the signal strength is correct. - If the signal is too weak, or the beam blocked, the yellow LED will be on constantly. 3.6 Adjusting the sensitivity of the reflector (Rx) - It is possible to adjust the level of sensitivity, if external interferences such as light, dust, hot or cold air currents, etc, permit. The level of sensitivity is reduced by turning the rotating sensitivity selector (A) to a higher number (e.g. 9). Zero (0) provides the highest level of sensitivity. The standard position set by the manufacturer is 3. 3.7 Testing the detector - Test the error signal by blocking the infrared beam (yellow LED (3) lights up). The detector should fuction normally once the obstruction is removed. - The fire alarm should be tested using smoke from a smoke machine or test-fire. With a smoke test, observe the following: When the detector detects sufficient smoke between the reflector and receiver, the red alarm LED () lights up. If the concentration of smoke persists (> 0s), the detector will indicate alarm status after approximately 15-0 seconds. Alarm status is indicated by the red LED () and green LED (1) flashing alternately. The detector is reset by cutting the 4 V DC power supply. P-AB5/DE - Rev. C, 99015 7 Autronica AS

BRANNALARM Tilpasningsenhet FIRE ALARM Interface unit Nr. No. D Y N A M I C F I L T E R P R O C E S S 4 AutroBeam 5 in system Detector Reflector Tx/Rx Detecting area 1,5m - 0m 4 V DC Fire alarm control panel BRANN BN- 35 SLOKKEANLEGG AKTIVERT BRANNVENTILASJON AKTIVERT BRANNVESEN MOTTATT MELDING FLERE ALARMER AVSTILL KLOKKER TILBAKESTILL ALARMSTED UTKOBLET Address unit FORVARSEL FEIL DELER AV ANLEGGET UTKOBLET BS 100 NETT Fig.no. 8 AutroBeam 5 can be connected to Autronica control panel types BS-100 and BS-60, as well as to the BX-40 conventional panel. Resetting AutroBeam 5 means that the +4V operating voltage must be interrupted for -3 seconds. When interfacing to an addressable system, an address unit giving alarm by short-circuiting must be used (e.g. BN-35/N). When the conventional BX-40 control panel is used, the zone in which the AutroBeam 5 is installed must be configured to give alarm by short-circuit. Connection to the respective control panels is given by individual diagrams supplied. P-AB5/DE - Rev. C, 99015 8 Autronica AS

Technical data - AutroBeam 5: Dimension and installation: Consists of: Transmitter and receiver in the same housing. Reflector : Ø 85mm Weight (without bracket) Material Colour : 0.6 kg : Polycarbonate : Dark grey with light grey front. (RAL 7035, 7038) Front cover, smoked plexiglas. DETECTOR (Transmitter/Receiver) HxWxL: 80x150x80mm Beam : Infrared Max. range : 1,5-5m Width : 14m (7 m each side) Max. detection area : 350m Diameter of beam at 5m : 60 cm REFLECTOR Ø=85mm Operating voltage : 4V d.c. ± 0% (must be interrupted for -3 seconds on resetting) Current consumtion with 4V d.c.: Normal : 30 ma Alarm : 43 ma Fault : 18 ma Alarm + Fault : 30 ma External temperature : - 40 + 65 C Humidity (non-condensing) : Max. 95% R.H. Degree of protection : IP 44 Approval Recommended control panel : EN54/9 : BS-100, BS-60 and BX-40 (conventional). 105 80 Adjustable: 180 horizontally 90 vertically P-AB5/DE - Rev. C, 99015 9 Autronica AS

AutroBeam AutroBeam beam linjedetektor. detector Dekningsområde Coverage area and og distances avstander. Detector Detektor a/ a A b h a d c a = b = c = d = Distance between two parallel beams is equal to the width (a) of the surface area to be monitored (14 m). Distance between transmitter and receiver is equal to the lenght of the surface area to be monitored (A). Minimum distance between detector and wall is 30 cm. Minimum distance from the detector to a ceiling with a maximum height of 10 m is d=30 cm, h= room height (from floor to ceiling). P-AB5/DE - Rev. C, 99015 10 Autronica AS

Romhøyde, høyde under tak AutroBeam AutroBeam linjedetektor. beam detector Diagrammet viser detektorens dekningsområde i bredde The diagram shows the width of area monitored based ut fra høydeplassering on how the detector i rommet. is positioned in a room. Room height, height below ceiling (m) 30 0 15 1 10 8 6 4 9 6 Height Monteringshøyde mounted Maximum width of area Maks monitired overvåkingsbredde 10 11 1 13 14 15 (m) 7 8 9 10 (m) Ceiling-mounted detector Detector mounted lower Detektor under tak Lavere montert detektor P-AB5/DE - Rev. C, 99015 11 Autronica AS