Principles. Proton Precession Magnetometers



Similar documents
ARES II ADVANCED MULTI - CHANNEL AUTOMATIC RESISTIVITY & IP SYSTEM

Magnetic Surveying. Dr. Laurent Marescot.

One Port Network Analyzer

DELPH v3.0. seabed mapping software suite

Moultrie Group Subsurface Geophysical Surveys

Title: Search & Detection of Marine Wrecks Using Airborne Magnetometer. Address: Propulsion Division, SOREQ NRC, Yavne 81800, Israel.

Performance Evaluation of a UWB-RFID System for Potential Space Applications Abstract

User's Guide. Integrating Sound Level Datalogger. Model Introduction

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

Bruce B. Weiner, Walther W. Tscharnuter, David Fairhurst Brookhaven Instruments Corporation Holtsville, NY US

RELEASE NOTES. Trimble. SPS Series Receivers. Introduction. New features and changes

GPS 72. Personal Navigator. Read This First! quick start guide

Impedance 50 (75 connectors via adapters)

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment

IDEA Presentation SMALL CAMPUS CHILLED WATER PLANT OPTIMIZATION.

Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)

Application Information Fully Integrated Hall Effect Motor Driver for Brushless DC Vibration Motor Applications

NMR Techniques Applied to Mineral Oil, Water, and Ethanol

User Guide. Temperature and Humidity Datalogger. Model 42280

Transmitter Interface Program

AP Series Autopilot System. AP-202 Data Sheet. March,2015. Chengdu Jouav Automation Tech Co.,L.t.d

AUTOMOTIVE DYNAMOMETER HARDWARE AND SOFTWARE

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

Solution Derivations for Capa #11

Precession of spin and Precession of a top

RS platforms. Fabio Dell Acqua - Gruppo di Telerilevamento

Matt Harris, Golder Associates (NZ) Ltd. The value of geophysics as a non-intrusive method for site characterisation

How To Understand The Measurement Process

Dyeing Programmer DP - 01

Rittal White Paper 305: Selecting Air Conditioners for Industrial Enclosures By: Judith Koetzsch Mark Corcoran, Editor

EasyStart R + Operating instructions. Comfort radio remote control with integrated timer for parking heaters and more.

Introduction to Trimble Access. The Next Generation of Survey Controller S-0102

ARES AUTOMATIC RESISTIVITY & IP SYSTEM. 850 W V p-p - 5 A Transmitter for all Multi-Electrode and Manual Modes Up to 10 Adjustable IP Windows

DC Electronic Loads 8500 series

Ground Resistance Clamp On Tester

Module 13 : Measurements on Fiber Optic Systems

Magnetic survey at Nesodden survey and interpretation report

Adaptation of General Purpose CFD Code for Fusion MHD Applications*

Leica SmartNet UK & Ireland Network RTK User Guide

How To Use A High Definition Oscilloscope

Microcontroller for Variable Speed BLDC Fan Control System. T.C. Lun System Engineer, Freescale Semiconductor, Inc.

Proactive Monitoring of Friction Management Systems Reduces Costs and Downtime

Optical Encoders. K. Craig 1. Actuators & Sensors in Mechatronics. Optical Encoders

PHANTOM 2 Product Release Notes

POWER. Your Partners in Availability POWER

Pulsed Fourier Transform NMR The rotating frame of reference. The NMR Experiment. The Rotating Frame of Reference.

Harry s GPS LapTimer. Documentation v1.2. Harry s Technologies

CHARACTERISTICS OF DEEP GPS SIGNAL FADING DUE TO IONOSPHERIC SCINTILLATION FOR AVIATION RECEIVER DESIGN

Application of Nuclear Magnetic Resonance in Petroleum Exploration

Detection and classification of underwater targets by magnetic gradiometry

SURVEY PRO. GPS Quick Start Guide

Water Distribution System Wireless Monitoring Solutions

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

DS1104 R&D Controller Board

Nuclear Magnetic Resonance (NMR) Spectroscopy

Power Amplifier Gain Compression Measurements

Installation and User s Manual Global Tracking and Tracing System. GTTS-2000Bi

16 th IOCCG Committee annual meeting. Plymouth, UK February mission: Present status and near future

CryoEDM A Cryogenic Neutron-EDM Experiment. Collaboration: Sussex University, RAL, ILL, Kure University, Oxford University Hans Kraus

Ultraprint 2000 HiE. Ultraprint 2000 HiE Features MODULAR DESIGN ENSURES SUPERIOR ADAPTABILITY

Uses of Derivative Spectroscopy

Wahl C50 Calibrator FEATURES

AA and AB-Series Analog Sensors

SPOT5 User Guide 30 November 2015

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

DAB Digital Radio Broadcasting. Dr. Campanella Michele

Sigma Control PC INSIDE. 97 psi 187 F R on load

ION Geophysical 2105 CityWest Blvd., Suite 400 Houston Texas Tel Fax iongeo.com

Application Note. EtherCAT Master Architecture. Applicable Products: Yaskawa Servodrives with CANopen over EtherCAT

Big Data Collection and Utilization for Operational Support of Smarter Social Infrastructure

Table of Contents. TransformerIQ FAQs 1

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

Distributed Temperature Monitoring of Energy Transmission and Distribution Systems

Mold Alert... Operation Manual P0270

Commercial Refrigeration Temperature and Defrost Controls

Current Standard: Mathematical Concepts and Applications Shape, Space, and Measurement- Primary

How To Understand Electron Spin Resonance

AMR and GMR Heads Increase Hard Drive Capacity in Western Digital Drives

Navi-Radar 4000 and Navi-Sailor 4000 ECS for workboats and small crafts BIG SOLUTIONS FOR SMALL VESSELS

Using Optech LMS to Calibrate Survey Data Without Ground Control Points

RF Measurements Using a Modular Digitizer

ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0

INSTRUMENTATION AND CONTROL TUTORIAL 3 SIGNAL PROCESSORS AND RECEIVERS

AN-007 APPLICATION NOTE MEASURING MAXIMUM SUBWOOFER OUTPUT ACCORDING ANSI/CEA-2010 STANDARD INTRODUCTION CEA-2010 (ANSI) TEST PROCEDURE

Magnetometer Underwater Detection Range, A Mechanical Expansion Amplifier Application

Groundwater Training Course SOPAC, April Electromagnetic (EM) Induction method for Groundwater Investigations

FREQUENCY RESPONSE ANALYZERS

DataView DVTH Data Logger for Temperature and Humidity

Quasi-Continuous Wave (CW) UV Laser Xcyte Series

22X DSP COLOR ZOOM CAMERA AUTO FOCUS ZOOM CAMERA

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

This datalogger is ideal for the Food Industry where process profiling is crucial to production efficiency and energy use optimisation.

Why a torque measuring system?

Robot Perception Continued

AIRAH Presentation April 30 th 2014

SX460. Generator Automatic Voltage Regulator Operation Manual

Transcription:

Proton Precession Magnetometers Sometimes called the grandfather of magnetometers, proton precession units serve an important function for earth science professionals seeking inexpensive solutions for low-sensitivity fieldwork or academic. Major applications include: Principles The method is based on the spin of protons in a magnetic field according to the Larmor equation. Locating buried ferrous containers (ex. contaminant waste drums) in environmental surveys. Locating and tracing buried pipelines in utility-type surveys. Locating abandoned wells for decommissioning and sealing. Geologic mapping. Teaching of geophysical methods. Other applications, such as mineral exploration surveys, UXO, archaeology and other surveys not listed may be better performed with Overhauser or Optically Pumped Potassium systems. Typically, a sensor bottle containing a fluid with a large number of protons (such as kerosene) is subjected to a large direct current in a coil wound around the bottle. The current creates a corresponding induced field in a direction perpendicular to the earth s magnetic field. Proton precession has limitations, such as order of magnitude lower sensitivity than Overhauser and two orders of magnitude lower sensitivity than Potassium. Other limitations include low sampling rates, high power consumption, and additional weight. However, precession methods are still viable in many applications. GEM s proton precession system has particular advantages as described elsewhere in this document. The current is then shut off and the protons precess with a frequency that is proportional to the magnetic induction. With GEM, an advanced frequency counting algorithm is used to determine

the magnetic intensity with an accuracy that is unmatched by other systems. When choosing a proton precession system, we recommend that you carefully consider the system specifications on an equivalent footing to ensure that you are obtaining the maximum value for your investment. The following table compares specifications for different manufacturers. Note that manufacturers are not named explicitly as GEM s practice is to maintain integrity and ethical practice in its customer-focused communications. Specification GEM GSM-19T Family Other 1 Other 2 Configuration Options 15 10 2 Cycle Time 999 to 0.5 sec 2, 1, 0.5 sec 999 to 1.5 sec Environmental -40 to 60 Celsius -40 to 60 Celsius -20 to 50 Celsius Gradient Tolerance 7,000 nt/m? 1000 nt/m Magnetic Readings 299,593 140,000 5,700 Operating Range 10, 000 to 120,000 nt 20,000 to 110,000 nt 20,000 to 90,000 nt Power 12 V @ 0.62 A 12 V @ 0.65 A 9 1.5 D Cell Batteries Sensitivity 0.1 nt @ 1 sec 0.1 nt @ 2 sec 0.1 nt @? sec Weight (Console/Sensor) 3.2 Kg 3.45 Kg 4.5 Kg Special Capabilities Automatic Grid Setup Yes No No Integrated GPS Yes No No Internet Upgrades Yes No No Simultaneous Grad Yes Yes No Warranty 2 Years 1 Year 1 Year Waypoint Navigation Yes No No Waypoint Programming Yes No No

Configuration Options GEM has 15 configurations that are constructed from 5 basic building blocks, including mag, grad, vlf, mag/vlf, and grad/vlf. Each of these building blocks can be augmented with GPS and / or Walking mode. The Walking mode is a mode that simulates the high-density coverage provided in airborne surveys. The operator advances to a station and takes a reading. When the data is dumped from the unit, the system automatically interpolates intervening values. Cycle Time Cycle time is an important parameter as it controls survey efficiency. GEM has a basic mode (GSM-19T) that cycles from 999 to 3 seconds this mode requires the operator to stop to take a measurement. Alternately, an enhanced version (GSM- 19TW) enables the operator to acquire data much faster in Walking mode. Environmental The test of an instrumentation system is its robustness in temperature extremes. The GSM-19T proton precession unit has been used around the world. It is fully experienced in environmentally challenging settings, ranging from harsh polar climates to the steaming jungles of equatorial countries to dry deserts. Gradient Tolerance Gradient tolerance is key when operating in areas where magnetic fields vary rapidly (either due to geology or to the presence of cultural objects or ferrous debris). Comparative tolerance is especially high for GEM s system. Note that where very high gradients are encountered, it may be desirable to consider Overhauser or Optically Pumped Potassium instruments. Magnetic Readings In 2001, the v6.0 system was launched. It includes standard 4 Mbyte memory that can be upgraded in 4 Mbyte increments to a maximum of 32 Mbytes. When choosing your magnetometer, gradiometer or base station solution, it is important to make sure that you will have enough memory to make it through a day s surveying without interruption. The GSM-19T is designed with this objective in mind. Operating Range Operating range should be sufficient to enable you to take readings wherever you are operating. GEM s proton precession is the highest rated system. Please note that precession systems may still have problems in equatorial regions due to the inherent physics. To learn about advantages of Overhauser, access: www.gemsys.on.ca/quantum/exploration/prospecti ng%20in%20low%20magnetic%20latitudes.htm

Power Consumption High power consumption is one of the limitations of proton precession systems. In fact, about 99% of the DC current applied for polarization is dissipated as heat energy. This high power need is one of the reasons that systems are heavier than Overhauser instruments (i.e. more batteries are required). However, proton precession systems will still perform well for many applications; GEM offers the lowest power consumption available; meaning that field time is prolonged as long as possible. Sensitivity Sensitivity is a statistical value indicating relative uncertainty of repetitive readings of the same magnetic field intensity. It is defined as r.m.s. (root - mean - square) value per square root of a unit of bandwidth (Hz 1/2 ). For example, a sensitivity of 1 pt / Hz 1/2 means 1 pt r.m.s. (about 3-4 pt peak-to-peak depending on the character of the noise) will be a scatter of readings about any "etalon" (fixed value) of the applied magnetic field per 1 Hz of measurement bandwidth. The sensitivity of quantum units is determined by the signal-to-noise ratio obtainable from its sensor, the spectral line width on which it operates and on the gyromagnetic constant, in accordance with the following equation: B = k Γ/ γ n S n where k is a constant of proportionality, Γ is the spectral line width, γ n is the gyromagnetic constant and S n is the signal-to-noise ratio. Any well-designed magnetometer s readings will eventually be limited by a noise level that cannot practically be suppressed any further: Sensor thermal noise is typically the limiting factor in the case of Proton and Overhauser magnetometers. The following diagram shows the sensitivity of GEM s proton (GSM-19T), Overhauser (GSM-19) and potassium (GSMP-40) systems. Each system has its own characteristic sensitivity envelope defined by sample interval. 0.25 0.2 0.15 0.1 0.05 0 3s 1s 0.5s 0.2s 0.1s 0.05s GSM-19T GSM-19 GSMP-40 Note that the proton sensitivity at 0.5 seconds is 0.5 nt, and is cut-off at 0.25 nt for illustrative purposes. Weight Proton precession weight is primarily a function of battery weight a reflection of the high power consumption for DC polarization.

Automatic Grid Setup The automatic grid setup capability delivers efficiency in defining your survey. To use this option, you access the corresponding menu and enter the starting and finishing points of your first line, and a direction (clockwise or counter clockwise). GPS with on-board corrections for realtime DGPS using WAAS or subscription services. Internet Upgrades The system then automatically generates a survey grid of 500 lines. You can use as many or as few lines as required to complete your survey. Integrated / External GPS With precise GPS positioning comes the ability to significantly speed up surveys and to acquire reliable information for decision-making. Integrated GPS is an attractive option in GEM s proton precession systems minimizing the potential for damage to GPS components and minimizing the physical size of units for reduced shipping costs. Where sub-metre resolution is required, GEM also provides an external Imagine that your manufacturer has the ability to deliver the latest technology to your magnetometer via periodic web updates. Now envision the money you will save no shipping costs to have the latest modifications or to add functionality to your unit. GEM provides these benefits as a standard feature in all its proton precession magnetometers. Simultaneous Gradiometer Gradiometer configurations deliver a number of advantages for near surface and deeper work, including resolution of shallower targets as well as the ability to acquire data without performing diurnal surveys (other benefits are described in www.gemsys.ca/quantum/technology/gr adiometer%20advantages.htm). It s important, however, to have sensors recording at exactly the same time particularly if the system is to be used for diurnal corrections or in areas of high

magnetic gradients. This capability is provided in all GEM systems, including proton precession, Overhauser and potassium. Waypoint Navigation GEMLinkW Software No system is complete without software for downloading and correcting your data, and GEM provides you with the proven GEMLinkW software for this purpose. Waypoint navigation delivers several functions. These include the ability to enter a set of waypoints for use in GPS surveying mode, and lane guidance. The system guides you to each waypoint - keeping you within a user-defined lane. GEM-VIS Software The main benefits lie in survey efficiency and tight survey control for as accurate positioning as possible. You also have the ability to perform surveys along lines that are non-parallel a useful capability for environmental-type or non-standard, roving surveys. GEM-VIS is an optional package developed by a major commercial software house for GEM s users. It enables rapid quality control and analysis with easy visualization of profiles and stacked plots as well as 2D and 3D grids. Waypoint Programming This option enables you to enter waypoints from either keyboard or download from your personal computer for maximum efficiency. www.gemsys.ca