1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4



Similar documents
HERZ-Thermal Actuators

SunMaxx Solar Filling Station Operating Instructions

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

LK Electric Boiler - 4,5

Data sheet ECC 12 and 22

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

ECOCIAT. Domestic hot water heat recovery unit

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Laddomat Charging unit

Oil and Coolant Circulating Heating System. Model - OCSM

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

stainless steel pre-assembled manifolds

BERMAD Fire Protection

FILLING AND PURGING THE SYSTEM

Series description: Wilo-Star-Z

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

SOLAR HEATING SYSTEMS.

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Overheating limit control

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Description of functions

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Electric Water Heater

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

Thermostatic valve Type AVTA

Operators manual Basic water heater

Power consumption (kw)

Automatic control equipment for HVAC systems

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

User Manual THR840DUK Digital Thermostat

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

01 12 COOLING SYSTEM COOLING SYSTEM. End of Toc. End Of Sie

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Frequently Asked Questions

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Zenith Solar thermal 4.5m pump station Installation manual

Technical data. Danfoss DHP-A

building engineering services association specification for: Domestic Heating

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING

Hydraulic Control Solutions

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1 General information

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Comfort Compact Controller ZG 215N

Utility Distribution Systems

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Thermostatic expansion valves type TR6 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Electronic Pressure Switch EDS 300

Your safety and the safety of others are very important.

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

3/2-way Solenoid Valve, direct-acting, NC or NO

Stainless Steel Single and Dual Circulation Kits

Globo P. Ball valves Pump ball valve made of gunmetal

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

ENGINE COOLING SYSTEM

BERMAD Fire Protection

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Valve range. To be precise.

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Self-operated Temperature Regulators Temperature Regulator Type 1u

Drayton Digistat +2RF/+3RF

Volkswagen Golf > VW Rabbit GTI 2006->

Conlift1, Conlift2, Conlift2 ph+

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

MOUNTING AND OPERATING INSTRUCTIONS

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

For installation guide see reverse of book

PNEUMATIC CONTROLS Selection and Description

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Cooling system components, removing and installing

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Heating, air-conditioning, cooling

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

Technical Specification. Generating Set with Waukesha engine burning natural gas

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

SWIMMING POOL HEAT PUMP Owners Manual

Operator: Save these instructions for future use!

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Electric Rotary Actuator - On/Off or programmable control actuator

Cable Plug acc. to DIN EN , Form A

ACCUMULATOR INSTALLATION

Transcription:

Henco Snelselectie kaart EN IMPORTANT! Before starting work the fitter must carefully read this installation and operation manual, understand and observe its conditions. The water floor heating control unit may be mounted, operated and maintained only by specially trained personnel. Personnel undergoing training may only work on the product under the supervision of an experienced fitter. Only when the above conditions are fulfilled, the manufacture is responsible for the equipment as provided in the legal regulations. Fig.1 All instructions in this assembly and operation manual must be observed when working with the water floor heating control unit. Any other application is not in compliance with the regulations. The manufacturer shall not be responsible for incompetent use of the water floor heating control unit. Reconstructions and changes are not acceptable for reasons of safety. The water floor heating control unit may be repaired only by services approved by the manufacturer. The temperature range and the contents of the set depend on the model and equipment. Subject to technical modification! 1. RANGE OF APPLICATION 1. DETAILS, SYMBOLS AND ABBREVIATIONS 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4 5. INSTALLATION AND ELECTRICAL CONNECTION 4 5.1. MOUNTING OF THE CONTROL UNIT 4 5.. ELECTRICAL CONNECTION 5.3. TEMPERATURE LIMITER (TB). START-UP.1. FLUSHING THE HEATING CIRCUITS.. ADJUSTMENT OF THE FLOOR HEATING FLOW TEMPERATURE.3. LIMITATION OF THE FLOOR HEATING FLOW TEMPERATURE. MODE OF OPERATION OF THE CONTROL UNIT. TECHNICAL DATA / MATERIALS. TROUBLESHOOTING 1. RANGE OF APPLICATION The control unit is developed for maintaining constant flow temperature in low-temperature radiant heating systems. The flow temperature may be adjusted gradually between 0 and 0 С, by means of the thermostat. The limitation of the adjustment range is possible according to the maximum/minimum temperature. The temperature value can be read from the thermometer of the control unit. The control unit is suitable for use in installations with combined panel heating/cooling and radiator heating. In cooling operation the thermostatic head fully opens the 3-way-mixing valve and at the same time closes the bypass. Thereby the flow temperature shall be controlled by the chiller (e.g. combined heat pump heating/cooling). The control unit can be mounted either to the right or left of heating circuit manifolds with 1" male thread and distance between supply and return branch of 10 mm. For that it is equipped with union nuts G 1". The control unit has been designed for use in dry environments, e.g. in residential rooms, office spaces, and industrial facilities. Usually the unit is installed in the central heating room or in a manifold cabinet. Verify that the installation complies with existing regulations before operation to ensure proper use of the installation. HENCO Industries NV Toekomstlaan - B-00 Herentals Tel. +3 14 5 0 Fax +3 14 1 1 www.henco.be

. DETAILS, SYMBOLS AND ABBREVIATIONS For better understanding in this document references are used in the form of symbols and abbreviations, which are described below: Reference to resuming documents. Important information and application hints Safety instructions or important note to the function. Shut-off: no flow Open: flow with indication of flow direction AG male thread EUKO male thread with euro cone FBH floor heating FH radiant heating (generally) FH/K radiant heating/cooling FK radiant cooling FRG floor heating control unit HK HKM HKV IG MuB RV KFE heating control unit heating control unit with mixing valve manifold female thread installation leaflet check valve fill and drain cock SKB TB UM UWP WDS WE WP gravity flow stop temperature limiter union nut circulation pump heating insulation box boiler / heat generator heat pump 3. SAFETY INSTRUCTIONS WARNING: Always disconnect the power supply prior to performing any installation or connection operations! All installation and wiring work at the unit must be carried out only in an idle condition. The appliance may be connected and put to operation by qualified personnel only. Make sure to adhere to valid safety regulations, in particular to VDE 0100 (German standard governing power installations with nominal voltages 1000 VAC). The control units are neither splash- nor drip-proof. Therefore, they must be mounted in a dry place. 4. DESIGN 10 ca. 0 mm 1 1: Floor heating/cooling supply (1 UM) : Floor heating/cooling return (1 UM) 3: Primary supply (1 AG) 5 4: Primary return (1 AG) 5: Circulation pump : Thermostatic head : 3-way-mixing valve : Check valve (RV) : Supply temperature thermometer 10: Temperature limiter (optional) : Z-type fitting with immersion sleeve for supply temperature sensor. 10 mm 5. INSTALLATION AND ELECTRICAL CONNECTION 3 4 Fig. 5.1. MOUNTING OF THE CONTROL UNIT The unit is dedicated for flat sealing connecting to a manifold with 1 male thread and distance between supply and return branch of 10 mm. Please pay attention not to damage or break the cables of the pump and temperature limiter as well as the capillary pipe of the thermostatic heads remote sensor while assembling. The cables must be installed without tension. The correct installation of supply and return has to be ensured (Fig. and Fig.3.1 3.4). HENCO Industries NV Toekomstlaan - B-00 Herentals Tel. +3 14 5 0 Fax +3 14 1 1 www.henco.be

Installation diagram radiator and floor heating Separated ascending pipes Installation diagram radiator and floor heating Common ascending pipe 5 30 V 1 5 30 V 1 4 3 4 3 1 1 1 Fig.3.1 1 Fig.3. Installation diagram floor heating/cooling Separated boiler and chiller Installation diagram floor heating/cooling Reversible heat pump (for heating and cooling) 30 V 1 30 V 1 1 1 1 M 1 Fig.3.3 Fig.3.4 1 Boiler Circulation pump boiler / radiator circuit 3 Boiler / Radiator supply 4 Boiler / radiator return 5 Radiator FH/K supply FH/K return Manifold (HKV) Fill and drain cocks (KFE) 10 3-way-mixing valve with thermostatic head Circulation pump for FH/K 1 Temperature limiter (option) Remote sensor of thermostatic head 14 Check valve Shut-off valves (recommendable) 1 Chiller 1 Zone valve 1 Reversible heat pump (heating and cooling) 1 Hydraulic switch L N PE C 1 UWP L PE N TB WTC-ES / WTC-IS PE Fig.4 HENCO Industries NV Toekomstlaan - B-00 Herentals Tel. +3 14 5 0 Fax +3 14 1 1 www.henco.be

5.. ELECTRICAL CONNECTION All electrical connections must be performed by an authorised specialist in accordance with the local regulations governing electrical installation work. The electrical cables must not come into contact with any hot parts. Both the circulation pump and the temperature limiter are connected with cables ex-works (see Fig.4). The power supply has to be established on site. In order to make sure that the pump only runs if heat requirement exists, the manufacturer recommends connecting it to a pump relay (e.g. pump logic of an electrical connection box which controls the actuators). Alternatively operate the pump by means of a timer. Further information about electrical connections exists in the MuB of the pump and temperature limiter 5.3. TEMPERATURE LIMITER (TB) In the event of malfunction, the TB switches off the circulating pump to prevent overheating of the floor heating system. To avoid undesired activation, the temperature on the TB should be set several degrees above the desired flow temperature. In practice the usual maximum temperature value is approx. 55 C. That corresponds to the factory setting of the TB. If necessary this maximum temperature must be adapted to the local conditions. If all floor heating circuits are equipped with actuators and no pump relay is used, the TB should be installed on the supply branch of the manifold.. START-UP.1. FLUSHING THE HEATING CIRCUITS Connect the control unit to the heating system. Shut off from the boiler circuit (using the ball valves () supplied with the manifold or via a shut-off device mounted on site). Switch off the pump and close all heating circuits at the manifold. It is sufficient to close only the valves in the return collector of the HKV using the protective caps. Fill the manifold and the FRG with heating water in accordance to VDI035 first. Connect the fill hose to the KFE cock mounted on the manifold return branch (Fig.5_b) and the discharge hose to the KFE cock on the manifold supply branch (Fig.5_a). Heating circuits shall be closed. Open the KFE cocks until water discharges on the KFE cock in the supply. Close both of the cocks. To fill and rinse the heating circuits connect the fill hose to the KFE cock on the supply branch of the manifold (Fig._a) and the drain hose to the KFE cock on the return branch of the manifold (Fig._b). Open the circuit to be filled and rinsed. Afterwards open the KFE cock and flush the loop until air and any impurities are completely removed from the circuit. The check valve (14) in the bypass of the 3-way-mixing valve prevents a short-circuit when rinsing the heating loops. Repeat that procedure for all heating circuits. a a 10 14 b 10 14 b Fig.5 Fig. Important: It should be rinsed only in the flow direction, i. e. the rinsing water has to enter at the KFE cock on the supply branch of the manifold and discharging via KFE cock on the return branch of the manifold! The drain/discharge connection must always be open; otherwise the high water pressure could damage the heating system. Also read the instructions on flushing as outlined in the installation/operating instructions for the heating circuit manifold. HENCO Industries NV Toekomstlaan - B-00 Herentals Tel. +3 14 5 0 Fax +3 14 1 1 www.henco.be

B A C.. ADJUSTMENT OF THE FLOOR HEATING FLOW TEMPERATURE The flow temperature may be adjusted gradually between 0 to 0 C ( to F). The regulating hand wheel of the thermostat is supplied with a scale 1- (Fig._A). Please see the temperatures set on the scale in the table below: 1 3 4 5 0 C C 3 C 45 C 53 C C 0 C F.4 F. F 3 F 1.4 F 143. F F Fig..3. LIMITATION OF THE FLOOR HEATING FLOW TEMPERATURE As a rule, the flow temperature in floor heating systems should not be higher than 50 C (10 F). However, the data of the floor heating system can deviate and should be considered. The flow temperature of the system is often lower than the adjustable maximum value of the thermostat. To avoid damages in the floor structure caused by excess temperature, the flow temperature set value may be defined and limited on the thermostatic head. Therefore, it is most important to set the determined value and check it by means of thermometer during operation of the floor heating system. If it is correct, place the blocking elements (Fig._B) right before and behind the pointer (Fig._C). Furthermore the temperature set value can be protected against inadvertent manipulation using the tamper-proof cover.. MODE OF OPERATION OF THE CONTROL UNIT The mixing valve is designed as a proportional controller and operates without auxiliary energy. The thermostat situated in the supply is in continuous contact with the flow temperature at all times. Deviations from the target value result in an immediate change in valve stroke and, accordingly, a change in the volume of the hot water injected from the boiler circuit. The injected water volume is mixed with the return water from the manifold at the inlet to the circulation pump and, in this way, keeps the flow temperature constant within a narrow temperature range.. TECHNICAL DATA / MATERIALS Admissible ambient temperature range: 0 40 C (3 104 F) 1) Admissible operating flow temperature range: 0 0 C (3 1 F) 1) Maximum operating pressure: bar ( psi) Flow temperature setting range: 0 0 C ( F) Rated heat output: ) approx. 14 kw Power supply: 30 VAC 50 Hz Fittings: Brass Ms 5 Pipes: Brass Ms 3 or stainless steel Plastic: Impact- and temperature resistant Gaskets: AFM 34 or EPDM O-Rings: EPDM 1) Please refer also to technical leaflets of the pump ) The temperature set value can be protected against inadvertent manipulation using the tamper-proof cover HENCO Industries NV Toekomstlaan - B-00 Herentals Tel. +3 14 5 0 Fax +3 14 1 1 www.henco.be

. TROUBLESHOOTING X. PROBLEM X.X Possible cause Solution 1. THE HEATING CIRCUITS OF THE FLOOR HEATING (FH) ARE NOT HEATED UP 1.1 The temperature limiter (TB) switches off the circulating pump of the control unit. Cause: TB is set to a very low value. Set the TB by approx. 10 K higher than the required flow temperature for FH. Take into consideration the max. admissible flow temperature! Differential gap of the TB: approx. K. The unit restarts quicker if the TB is removed from the unit for a short time to allow a faster cooling down to switch-on temperature. 1. The TB switches off the circulating pump of the control unit. Cause: Initially, the circulating pump remains switched on even when all of the floor heating circuits are blocked. The idle running of the pump without water circulation heats up the water due to waste heat of the pump motor. On reaching the maximum temperature, the TB switches off the circulating pump! Remove the TB from the compact control unit and install it at the supply line or, eventually, at the return line of the heating circuit manifold. Use an electrical connecting box with pump relay (pump logic). Thanks to the relay, the circulating pump operates only if at least one heating circuit of FH is opened (requires heat). 1.3 The circulating pump is connected to a room-temperature thermostat or to an electrical connecting box. Remove the TB from the compact control unit and install it at the supply line or, eventually, at the return line of the heating circuit If all the actuators close, the pump is switched off. If the idle period is manifold. longer, the supply water for FH is cooled down. Therefore, the injection Subsection 1.1 should also be taken into consideration. mixing valve opens and hot water is injected from the primary circuit. As a result, the control unit is heated up. On reaching the TB s switch-off temperature, the contact opens. The pump will not switch on again.. THE SUPPLY WATER TEMPERATURE CANNOT BE SET TO THE REQUIRED VALUE OR IT FLUCTUATES WITHIN A VERY WIDE RANGE.1 The compact control unit s supply (inlet) pipe and return (outlet) pipe are misconnected. Check all inlets and outlets of the compact control unit for correct connection. Supply inlets and return outlets are marked with stickers. Please take into account Fig. and 3.. The circulating pump s pressure head/pump stage is set at a very high value. Increase the rotation frequency, the pump s pressure head/pump stage, respectively..3 The heating load is too big for the control unit used, i.e., the heat consumption exceeds the rated heat output of the compact control unit. This state may set in temporarily, e.g., in case of heating a cold floor for the first time..4 Thermostatic head is defective R Check the maximum heat consumption and compare it with the rated heat output. If necessary, distribute the heating circuits to a second control unit with a respective manifold. If the cause is in the initial heating up of a given floor heating system, the function may be normalized after the heating up phase. This is possible chiefly in an operating mode within the top values of the rated power. eplacement of thermostatic head. HENCO Industries NV Toekomstlaan - B-00 Herentals Tel. +3 14 5 0 Fax +3 14 1 1 www.henco.be