Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007



Similar documents
For additional information, please visit our website at

Trace Dissolved Oxygen Sensor

General Purpose ph/orp Sensors

Dissolved Oxygen Sensors

Submersion/Insertion Toroidal Sensor

Sanitary and CIP Toroidal Sensor

ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.

Submersion/Insertion Toroidal Sensor

Toroidal Conductivity Sensor

General Purpose ph/orp Sensor

ENDURANCE Conductivity Sensors

DISSOLVED OXYGEN PROBE

Stainless Steel Single and Dual Circulation Kits

REPAIR AND MAINTENANCE MANUAL

Your safety and the safety of others are very important.

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

Multi-Parameter Electrochemical / Optical Water Quality System

PART 1 - INTRODUCTION...

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Operator Quick Guide EC SENSOR

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty

Sanitary Type Electronic Flow Switches

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

OxyGuard. Dissolved Oxygen Probe

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

TB2CS Conductivity sensor 2-Electrode. Superior accuracy in low level conductivity measurement ranges

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

High-Purity Fluoropolymer Fittings

Milwaukee USER MANUAL

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors

INGROUND, ROPED, AND HOLELESS JACK SEAL REPLACEMENT

Watts Pure Water Systems

Munchkin Heat Exchanger Maintenance

Self Purging Liquid Trap (SPLT ) User s Manual

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Fiberstars Lighted Laminar Flow Fountain Installation Manual

NITROUS TRANSFER PUMP INSTRUCTIONS

6 H2O + 6 CO 2 (g) + energy

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

MAC FAUCETS. Owner s Manual. Models: FA444

AMERBRITE UNDERWATER WHITE LED POOL LAMP

ATS Overhead Table Shelf System INSTRUCTION MANUAL

SMD Rework Station TABLE OF CONTENTS

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

OWNER S MANUAL. FOOTWORKS tm Faucet Controller. Foot Operated Faucet Control Valves for Commercial Sinks

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Typical Aluminum GFM Mass Flow Meter

2100 AD Mirror Elevator Ball Nut Replacement Procedure

Electronic Flow Switches

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

with installation dynafact boost GAUGE this manual is for use with systems

MODEL G300 BRAKE BLEEDER

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

AMX300 DirectConnect Mixing Valve Kits

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

How To Replace A Reverse Osmosis Water Tank

Installation Instructions

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Installation Instructions for Water Methanol Stage 1

Universal Installation and Maintenance Instructions 71CD-1212 Spill Containment Bucket

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

INSTALLATION INSTRUCTIONS BL-8704

Cables. Accessories. For Force, Torque and Strain Sensors

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

SunMaxx Solar Filling Station Operating Instructions

Installation Instructions S

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

KUSTER ELECTRONIC GAUGES

INSTALLATION INSTRUCTIONS MK-8704

INSTALLATION & OPERATING INSTRUCTIONS

Co-location Interconnect Power Panel (CIPP) Installation Guide

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

TYPE E Main Valve Sizes 3 /8 through 12

How To Use A Flowmeter

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

Galvanic Parts Per Million Dissolved Oxygen Systems

Digital inductive conductivity transmitter

Powers Controls TH 192 S Single Temperature Room Thermostat

Baumann 24000SB Barstock Control Valve

STANDARD OPERATING PROCEDURE Dissolved Oxygen Measurement, Meter Calibration and Maintenance

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Stainless Steel Dissolved Oxygen Electrodes

B150 Series Commercial Brewer. Direct Plumb Kit

81000 Series Aluminum Gate Valve Installation and Repair Manual

123 Industrial Loop Road Paynesville, MN Phone:

Transcription:

Instruction Sheet PN 51A-499AOZ/rev.F January 2007 Model 499A OZ Ozone Sensor For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit our website at www.emersonprocess.com/raihome/liquid/. SPECIFICATIONS - SENSOR Pressure: 0 to 65 psig (101 to 549 kpa abs) Temperature: 32 to 122 F (0 to 50 C) Process Connection: 1 inch MNPT Wetted Parts: Polysulfone, Viton 1, Teflon 2 TFE, silicone Cathode: gold 1 Viton is a registered trademark of E.I. dupont de Nemours & Co. 2 Teflon is a registered trademark of E.I. dupont de Nemours & Co. CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY The wetted sensor materials may not be compatible with process com position and operating conditions. Application compat ibility is entirely the responsibility of the user. CAUTION Do not exceed pressure and temperature specifications. Pressure: 65 psig max (549 kpa abs max) Temperature: 32 to 122 F (0 to 50 C) SPECIFICATIONS - FLOW CELLS Type PN Wetted Materials Process Connection Maximum Temperature Maximum Pressure 1-1/2 in. tee 23567-00 CPVC, Buna N 1-1/2 in. socket 122 F (50 C) 65 psig (549 kpa abs) 915240-03 3/4 in. NFPT 2 in. tee 915240-04 PVC, Buna N 1 in. NFPT 120 F (49 C) 60 psig (515 kpa abs) 915240-05 1-1/2 in. NFPT Low Flow 24091-00 Polyester/Polycarbonate, 1/4 in. tubing 122 F (50 C) 65 psig (549 kpa abs) 316SS, Silicone

INSTALLATION INSTALLATION Flow through Open channel Low flow cell 1 to 5 gpm (3.8 to 19 L/min) 1 ft/sec (0.3 m/sec) 2 to 5 gph (7.6 to 19 L/hr) The Model 499AOZ sensor is NOT recommended for submersion into tanks, basins, or ponds. FIGURE 1. Sensor Orientation FIGURE 2. Flow-Through 2 in. Tee FIGURE 3. Flow-Through 1-1/2 in. Tee FIGURE 4. Low Flow Cell (PN 24091-00) 2

WIRING WIRING When making connections through a junction box (PN 22719-02), wire point-to-point. NOTE: Use a wire nut and pigtail (included) when connecting several wires to the same terminal. FIGURE 5. Pin Out Diagram for Model 499ACL-01- VP Sensor (top view of connector end of sensor) FIGURE 6. Wiring Sensor with Standard Cable to Model 1055 Analyzer FIGURE 7. Wiring Sensor with Optimum EMI/RFI or Variopol Cable to Model 1055 Analyzer FIGURE 8. Wiring Sensor with Standard Cable to Model 54eA Analyzer FIGURE 9. Wiring Sensor with OptimumEMI/RFI or Variopol Cable to Model 54eA Analyzer 3

WIRING FIGURE 10. Wiring Sensor with Standard Cable to Model 1056 Analyzer FIGURE 11. Wiring Sensor with Optimum EMI/RFI or Variopol Cable to Model 1056 Analyzer FIGURE 14. Wiring Sensor with Standard Cable to 5081-A Transmitter. FIGURE 15. Wiring Sensor with Optimum EMI/RFI or Variopol Cable to 5081-A Transmitter. 4 FIGURE 16. Wiring Sensor with Standard Cable to Xmt-A Transmitter. FIGURE 17. Wiring Sensor with Optimum EMI/RFI or Variopol Cable to Xmt-A Transmitter.

MAINTENANCE MAINTENANCE Periodic maintenance and cleaning is required for best performance of the sensor. Generally, the membrane and fill solution should be replaced every four to six months. Sensors installed in harsh or dirty environments require more frequent maintenance. The optimum maintenance frequency is best determined by experience. CAUTION: PRESSURIZED SPRAY INJURY Before removing the sensor from the process stream for maintenance, be sure the process pressure is reduced to 0 psig and the process temperature is at a safe level! CAUTION Fill solution may cause irritation. May be harmful if swallowed. Read and follow manual. CLEANING THE MEMBRANE. Keep the membrane clean and free from dirt. Clean the membrane with water sprayed from a wash bottle. Use a soft tissue to gently wipe the membrane. REPLACING THE ELECTROLYTE SOLUTION AND MEMBRANE. 1. Unscrew the membrane retainer and remove the membrane assembly and O-ring. See Figure 14. 2. Hold the sensor over a container with the cathode pointing down. 3. Remove the fill plug and allow the electrolyte solution to drain out. 4. Inspect the cathode. If it is tarnished, clean it by gently rubbing in the direction of the existing scratches (do not use a circular motion) with 400-600 grit silicon carbide finishing paper. Rinse the cathode thoroughly with water. 5. Wrap the plug with several turns of pipe tape and set aside. 6. Prepare a new membrane. Hold the membrane assembly with the cup formed by the membrane and membrane holder pointing up. Fill the cup with electrolyte solution. Leave the membrane assembly filled with electrolyte solution and set it aside. 7. Hold the sensor at about a 45-degree angle with the cathode end pointing up. Add electrolyte solution through the fill hole until the liquid overflows. Tap the sensor near the threads to release trapped air bubbles. Add more electrolyte solution if necessary. 8. Place the fill plug in the electrolyte port and begin screwing it in. After several threads have engaged, rotate the sensor so that the cathode is pointing up and continue tightening the fill plug. Do not overtighten. 9. Place a new O-ring in the groove around the cathode post. Cover the holes at the base of the cathode stem with several drops of electrolyte solution. 10. Insert a small blunt probe, like a toothpick with the end cut off, through the pressure equalizing port. See Figure 14. NOTE Do not use a sharp probe. It will puncture the bladder and destroy the sensor. Gently press the probe against the bladder several times to force liquid through the holes at the base of the cathode stem. Keep pressing the bladder until no air bubbles can be seen leaving the holes. Be sure the holes remain covered with electrolyte solution. 11. Place a drop of electrolyte solution on the cathode, then place the membrane assembly over the cathode. Screw the membrane retainer in place. 12. The sensor may require several hours operating at the polarizing voltage to equilibrate after the electrolyte solution has been replenished. 5

MAINTENANCE FIGURE 16. Sensor Parts SPARE PARTS 33523-02 Electrolyte Fill Plug 9550094 O-Ring, Viton 2-014 33521-02 Membrane Retainer 23501-11 Ozone Membrane Assembly: includes one membrane assembly and one O-ring 23502-11 Ozone Membrane Kit: includes 3 membrane assemblies and 3 O-rings 9210299 #3 Ozone Sensor Fill Solution, 4 oz (120 ml) 6

ORDERING INFORMATION ORDERING INFORMATION The Model 499AOZ sensor is intended for the determination of dissolved ozone in a variety of municipal and industrial applications. The sensor is generally intended for mounting in an off-line flow cell. The sensor is available with either an integral cable or a VP6.0 quick disconnect fitting. Three replacement membrane assemblies, three o-rings and a 4-oz (125 ml) bottle of electrolyte solution are provided with each sensor. MODEL 499AOZ DISSOLVED OXYGEN SENSOR CODE Required selection 54 For use with Model 1054AOZ, 1054BOZ, 1055-26, 54eA, Xmt-A, and 5081-A analyzers CODE Optional selection 60 Optimum EMI/RFI cable (not available with -VP option) VP Sensor with Variopol 6.0 fitting (interconnecting cable must be ordered separately) 499AOZ -54 -VP EXAMPLE FOR FIRST TIME VARIOPOL INSTALLATIONS PART # DESCRIPTION 23747-02 VP 6.0 interconnecting cable, 10 ft (3 m) 23747-03 VP 6.0 interconnecting cable, 50 ft (15 m) For junction box and connecting cable between junction box and analyzer, see ACCESSORIES. The cable in PN 9200275 (unterminated) and PN 23747-00 (terminated) is the same cable used in the VP interconnecting cable. 7

ORDERING INFORMATION ACCESSORIES PART # DESCRIPTION 23567-00 1-½ in. flow through tee with 1-½ socket connections 914240-03 2-in. flow through tee with ¾-in FNPT connections 915240-04 2-in. flow through tee with 1-in FNPT connections 915240-05 2-in. flow through tee with 1-½-in FNPT connections 24091-00 Low flow cell with ¼-in OD tubing compression fittings 9390004 Rotameter: 0.5-5.0 gph 22719-02 Junction box, 8 terminals 9200266 Extension cable for option -54, unterminated (specify length) 9200275 Extension cable for optimum EMI/RFI cable, unterminated (specify length) 23747-00 Extension cable for optimum EMI/RFI cable, terminated (specify length) 2001492 Stainless steel tag The right people, the right answers, right now. ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http://www.raihome.com Specifications subject to change without notice. Credit Cards for U.S. Purchases Only. Emerson Process Management Liquid Division 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com Rosemount Analytical Inc. 2005