Thermal Coupling Of Cooling and Heating Systems

Similar documents
High Pressure Ammonia Systems New Opportunities

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

Heat Recovery In Retail Refrigeration

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

How Ground/Water Source Heat Pumps Work

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Chapter 3.4: HVAC & Refrigeration System

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

Low GWP Replacements for R404A in Commercial Refrigeration Applications

Optimization of Water - Cooled Chiller Cooling Tower Combinations

HEAT RECOVERY FROM CHILLED WATER SYSTEMS. Applications for Heat Reclaim Chillers

ALONE. small scale solar cooling device Project No TREN FP7EN Project No TREN/FP7EN/ ALONE. small scale solar cooling device

UNIT 2 REFRIGERATION CYCLE

Hot water supply, distribution and use

Rainwater Harvesting

Creating Efficient HVAC Systems

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Natural geothermal energy.

Food & Drink Industry Refrigeration Efficiency Initiative

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Analysis of data centre cooling energy efficiency

Why and How we Use Capacity Control

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

LG Electronics AE Company, Commercial Air Conditioning

8. Refrigeration. 4. Liquid. Refrigerant. 4. Liquid Refrigerant. Figure 8.1 Refrigeration system layout (single stage)

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

Making heating systems efficient and cost-effective: boilers, heating controls & more

Condensing Economizers Workshop Enbridge Gas, Toronto. MENEX Boiler Plant Heat Recovery Technologies. Prepared by: Jozo Martinovic, M A Sc, P Eng

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

Energy consumption and heat recovery of refrigeration system in modern Arena

Q. Why have we set up an energy centre and heat network in Bunhill?

Refrigerant Choices for Commercial Refrigeration. Finding the Right Balance

POSSIBILITY FOR MECHANICAL VAPOR RE-COMPRESSRION FOR STEAM BASED DRYING PROCESSES

ARP Food Industry, Portugal

HEAT PUMPS A KEY COMPONENT IN LOW CARBON FUTURE

Serenbe Green Geothermal Solutions with Bosch Thermotechnology

HIGH-EFFICIENCY CO 2 HEAT PUMP WATER HEATER SYSTEMS FOR RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS

Second Place: Industrial Facilities or Processes, New

Optimization of Industrial Refrigeration Plants: Including a Case Study at Stonyfield Farm Yogurt

AE BIO SOLAR AE BIO SOLAR HYBRID PLANT SOLAR/BIOMASS ADESSO ENERGIA SRL HYBRID PLANT SOLAR/BIOMASS THE BEGINNING OF A NEW ENERGY PRESENTATION

CHILLER PLANT CONTROL MULTIPLE CHILLER CONTROLS

It s time for H.E.R.O. Energy Saving Strategy for. Tunnel & Shuttle Kilns

Evaporative Cooling for Residential and Light-Commercial

Sea Water Heat Pump Project

The Second Law of Thermodynamics

ENERGY SAVING WORT BOILING SISTEM IN BREWING FACTORY

Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas

How To Clean Water From An Ammonia Refrigeration System

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

GEOTHERMAL HEATING AND COOLING INTRODUCTION

Analysis of Ammonia Water (NH3-H2O) Vapor Absorption Refrigeration System based on First Law of Thermodynamics

ADVANCES IN SUPERMARKET REFRIGERATION SYSTEMS

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

ABSTRACT. aspects of potential waste heat recovery systems and the economics of installing them at selected survey factories.

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Energy Efficiency Best Practice Guide Industrial Refrigeration

ELECTRICAL ENERGY REDUCTION IN REFRIGERATION AND AIR CONDITIONING Ken Landymore, Director of Operations, Smartcool Systems Inc.

To find out more about installing a heat pump call or visit energysavingtrust.org.uk

Heat Recovery and Compressed Air Systems

Large Energy Savings Per Installation VFDs for Large Chillers

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 4, Lancaster University, 2 nd July 2014

Solar Cooling. Methods and Applications. Sargon Ishaya, PE, LEED AP

Waste Heat Recovery through Air Conditioning System

Measurement And Application of Performance Characteristics Of A Free Piston Stirling Cooler

Gas Absorption Heat Pumps. Future proofing your heating and hot water

HEAT PUMP FOR DISTRICT COOLING AND HEATING AT OSLO AIRPORT, GARDERMOEN

Nordic Heat Pump Product Guide

Recover Heat from Boiler Blowdown Water

Open Cycle Refrigeration System

Session 2: Hot Water Supply

Refrigeration & Air-conditioning Technician

AdSORPTION CHILLER NAK

October 8, WHP Waste Heat-to-Power Fuel and Emission Free Power

A NEW DESICCANT EVAPORATIVE COOLING CYCLE FOR SOLAR AIR CONDITIONING AND HOT WATER HEATING

Design of a Heat Pump Assisted Solar Thermal System

In touch with heat pumps for industry and commerce

Boilers and cogeneration/trigeneration. Abhi Sawant Business Development Manager Simons Green Energy

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

Solar Thermal TECHNOLOGY. Eric Buchanan Renewable Energy Scientist West Central Research and Outreach Center Wcroc.cfans.umn.edu

AMMONIA AND CARBON DIOXIDE HEAT PUMPS FOR HEAT RECOVERY IN INDUSTRY

ECOCIAT. Domestic hot water heat recovery unit

A Feasibility of Geothermal Cooling in Middle East

Energy Efficiency in Steam Systems

Vitocaldens 222-F Compact Gas-Hybrid appliance

HOT & COLD. Basic Thermodynamics and Large Building Heating and Cooling

POLK STATE COLLEGE CHILLER PLANT EVALUATION WINTER HAVEN, FLORIDA APRIL 2, C arastro & A ssociates, C&A# 5747

FLUID CIRCULATION PUMP PRESSURE

Crowne Plaza Copenhagen Towers The world s greenest hotel

REFRIGERATED COMPRESSED AIR DRYERS

Research on the Air Conditioning Water Heater System

How To Use A Water Source Heat Pump

Delivering exceptional performance and Ecovalue. Ecocent

ICE THERMAL STORAGE IN AIR CONDITIONING APPLICATION FUNDAMENTALS

HEATING GLASGOW UNIVERSITY WITH RIVER SOURCED HEAT PUMPS

GEOTHERMAL POWER GENERATION A PRIMER ON LOW-TEMPERATURE, SMALL-SCALE APPLICATIONS

Ambient Energy Fraction of a Heat Pump

Transcription:

This article was published in ASHRAE Journal, February 2011. Copyright 2011 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission of ASHRAE. For more information about ASHRAE Journal, visit www.ashrae.org. Thermal Coupling Of Cooling and Heating Systems By Andy Pearson, Ph.D., CEng., Member ASHRAE The economics justifying heat pump installations are brutally honest. If the system is too expensive or not efficient enough to compete with conventional heating methods, fancy sales arguments will not convince an owner to buy the system. The additional expense of the heat pump must be weighed against the reduction in operating cost. When the heat source is the discharge from a cooling system, the economics of heat pumps are immediately more attractive. Refrigeration systems extract heat at temperatures ranging from about 41 F (5 C) in chillers down to 58 F ( 50 C) in freezers. In contrast to this range, the heat rejected from the system is in a relatively narrow band. For large systems using evaporative cooling in temperate climates, the design condensing temperature typically will be about 95 F (35 C); in smaller air-cooled systems in hotter climates, this could be as high as 122 F (60 C). The output from the system is called waste heat because at these temperatures there is not much use for it, even in an industrial food factory or facilities such as a hotel, apartment block, hospital or prison. In all of these applications, a large demand exists for heat at slightly higher temperatures, typically ranging from 122 F to 203 F (60 C to 95 C). These heating demands have traditionally been served by burning fossil fuel on site for water heating or for steam raising, or by electrical heating where the electricity has been generated at much higher temperatures. It does not take complex exergy analysis to realize that a process that burns fossil fuel at about 3,200 F (about 1750 C) to heat something to 203 F (95 C) is capable of improvement. It also does not make sense to install an air source or geothermal heat pump in a fa- About the Author Andy Pearson, Ph.D., CEng., is managing director contracts at Star Refrigeration and an associate of Star Technical Solutions in Glasgow, Scotland. 1 8 A S H R A E J o u r n a l a s h r a e. o r g F e b r u a r y 2 0 1 1

cility that is rejecting plentiful amounts of heat to atmosphere at a higher temperature than the air or geothermal source for the heat pump installation. Harnessing the heat output from cooling systems can be done in several ways. The simplest is to run the plant at a higher heat rejection temperature so that the heat output is at a useful temperature. It is usually necessary to include a means of heat rejection to atmosphere to cover for the times when there is a need for cooling but no demand for heating. The additional complexity required to harness the heat includes an extra condenser, usually heating water or some other heat transfer fluid, and typically a shell and tube vessel or plate heat exchanger. If the temperature lift in the cooling system is wider than acceptable limits for the compressor, then an additional stage of compression is required. This is more complex because an extra compressor is in the system, but discharge gas from the main plant sometimes can be taken directly to the suction of the high-stage compressor so the heat Technology recovery condenser is the only additional heat exchanger. If this is not feasible (because the cooling and heating circuits need to be kept separate, or the discharge gas from the Table 1: Assessment of alternative schemes. cooling compressors is too hot to be fed directly to the suction of the high-stage compressor), an additional heat exchanger, either a cascade condenser or a desuperheater, also is required. Recent developments in ammonia compressors (first in reciprocating machines designed for 580 psig [40 bar] and then in single and twin screw compressors) have enabled heat recovery plants to be designed for all three configurations. Single screw compressors now are available with operating pressures sufficient to heat water to 203 F (95 C), so the full range of sub-steam temperature requirements can be met. If the required water temperature is above 187 F (75 C) then a steel bodied compressor, rated for 1,125 psig (75 bar) is required, but for lower temperatures a body of spheroidal graphite (SG) iron, rated for 725 psig (50 bar), is sufficient. The steel body is significantly more expensive. In a two-stage heat pump, the segregation of stages should be arranged so that steel bodies are only required for the high-stage compressors. Significant operational and environmental benefits have been achieved through the installation of a combined heating and cooling system at a confectionery factory in England that manufactures candy bars and chocolate. As with many such facilities, the heating and cooling requirements were previously handled separately. Cooling was done by a bank of 12 R-22 chillers with a total installed capacity of 1,535 tons (5400 kw) and heating was provided by coal-fired steam boilers delivering 60,000 lb/h (7.5 kg/s) of low pressure steam. The client was required to replace the equipment because R-22 use was becoming severely restricted, and the coal-fired boilers incurred a significant operating penalty in carbon credits. However, the need to install a new plant was viewed as a rare opportunity to make a significant improvement in site operating cost. The new system was required to provide efficient operation across a wide range of cooling and heating duties and to be flexible in operation, allowing for future changes in site utilization. Four alternatives were analyzed. The first proposal was to install a modern gas-fired boiler plant with packaged ammonia chillers. The second scheme also used packaged ammonia chillers for cooling, but with a combined heat and power plant providing the electrical power required to run the chillers and delivering the heating requirement. In the third scheme a comprehensive geothermal network provided the heating, again with packaged ammonia chillers. The fourth scheme was the only one to integrate the two requirements thermodynamically in what was called a thermally coupled system. Energy Rating Life-Cycle Cost Qualitative Score Gas Boiler/Ammonia Chillers 5.26 $36.37 Million 15 This was based on a central plant cooling system, but with additional high-pressure compressors raising the condensing condition sufficiently high enough to meet the heating requirement. The alternatives were rated according to the energy required, the present value of the system and qualitative factors (items that could not be assessed in terms of energy or value, but still had a bearing on the utility of the proposed solution). The results of the analysis for the project are shown in Table 1. The qualitative assessment included consideration of factors such as future flexibility, disruption to site during installation, initial capital cost, environmental impact and operational complexity. A low score indicates that the scheme is attractive. Although the geothermal system was cost effective over the 15-year life of the plant and consumed the least energy, it was not favored in the qualitative analysis for several reasons. The required size of an underground collector would have covered most of the site, and it was perceived as a significant restriction on future site use. For example, the collector would have made it difficult to sell a portion of the land for development in the future. With the geothermal solution ruled out, the thermally coupled heating and cooling system was the most attractive option. It used the least energy of the three alternatives, it had the lowest life-cycle cost, and it scored best in the qualitative analysis. The system was installed early in 2010, and has been fully operational since March. The cooling loads are summarized in Table 2 (Page 20), and are all serviced by a propylene glycol loop that delivers glycol at 32 F (0 C). The heating loads can be split into three main streams: cooking, cleaning and closed loop loads. The cooking requires steam at 260 F (125 C) and so cannot be fed by the CHP/Ammonia Chillers 7.87 $34.50 Million 19 Geothermal/Ammonia Chillers 2.13 $26.73 Million 23 Thermally Coupled Heating and Cooling 3.93 $31.39 Million 13 Fe b r u a r y 2 0 1 1 A S H R A E J o u r n a l 1 9

AC 487 ton Forming 201 ton Molds 100 ton Coolers 73 ton PHE 37 ton Storage 36 ton Tunnel 34 ton Total 967 ton Table 2: Schedule of cooling loads. Calorifiers Cookers Bowl Washers Other Users CIP Calorifiers Domestic Hot Water Losses Total Table 3: Schedule of heating loads. 2.811 MBtu/h 2.774 MBtu/h 0.861 MBtu/h 0.515 MBtu/h 0.447 MBtu/h 0.304 MBtu/h 0.945 MBtu/h 8.655 MBtu/h heat pump system, but it only accounts for about one third of the total site demand for heating. The cleaning load takes fresh water at 50 F (10 C) and heats it to 196 F (90 C). In the closed loop heating circuits, for example stopping chocolate from solidifying in the machines, the water circulates between 104 F and 140 F (40 C and 60 C). When the cooling and heating loads were compared it was concluded that the most economic installation would only provide a portion of the heating by coupling with the cooling system. The cooling system was designed with an installed capacity of 853 tons (3000 kw) but with pumps, vessels and pipework sized for a maximum capacity of 1,023 tons (3600 kw). The installed capacity is less than the total schedule because there is some diversity in the timing of the loads. For example, the air-conditioning load is more significant in the summer and the forming and molding loads are not continuous. The heating system was designed to accept water at 140 F (60 C) from the heat recovery circuit. The steam for cookers is generated by gas boilers and the top-up heating for the other circuits, from 140 F to 194 F (60 C to 90 C) is provided by the boilers. This reduces the heat demand from the heat recovery system to a total of 1,230 kw, with 40% going to the oncethrough circuit and 60% going to the closed loop. With this configuration, half of the heating demand is provided by waste heat from the cooling process, and it is only necessary to boost the condensing condition of the chillers from the standard design of 118 F to 138 F (43 C to 59 C). Heat rejection to atmosphere is through air-cooled condensers designed for a summer ambient of 95 F (35 C). In cooler weather the discharge pressure reduces to match the ambient conditions, with a minimum condensing condition of 68 F (20 C). When heating is not required by the process, and there is no further storage capacity available, the discharge pressure on the heat recovery part of the system drops back to the lower figure, making the cooling duty as efficient as possible. The system configuration is shown in Figure 1. Two of the com- 60 C CIP Circuit 10 C Desuperheater Desuperheater Condenser Subcooler Figure 1: Heat recovery circuits. pressors provide the base cooling load, with heat rejection to ambient. When heat recovery is required the other two compressors run at higher discharge pressure, drawing ammonia from the common evaporator on the glycol cooling circuit. Therefore, it is possible, with the two independent expansion valves feeding the gravity-fed receiver, to run the heat recovery circuit at a high discharge pressure and the heat rejection circuit at a much lower discharge pressure. If the cooling demand is high, but there is no requirement for recovered heat, then the heat recovery compressors are able to deliver gas to the air cooled condenser through the bypass valves on the discharge header, and will then operate more efficiently at reduced discharge pressure. To maximize the efficiency of the heat recovery system the oil separators on the heat recovery compressors are insulated. The compressor units can be seen in Photo 1. The glycol cooling circuit is served by a gravity fed plate heat exchanger, which uses a low ammonia charge to achieve the full cooling and heating requirement. The total ammonia content of the system is 2,600 lbs (1,200 kg), which is equivalent to a charge of 2.9 lb/tons (0.375 kg/kw). The additional charge due to the heat recovery is not significant because the heat recovery part of the circuit uses plate and shell heat exchangers. The main proportion of the ammonia charge is held in the air-cooled condensers and in the gravity feed surge Condenser High Pressure Discharge 2 0 A S H R A E J o u r n a l a s h r a e. o r g F e b r u a r y 2 0 1 1 60 C 40 C Oil Cooler Hot Process Circuit Low Pressure Discharge Compressors Suction Air-Cooled Condenser Cold Glycol Circuit

2008 Actual 2011 Projected Savings Energy Cost $2,797,470 $1,336,569 $1,460,901 Operating Cost $590,577 $124,332 $466,245 Climate Change Levy $512,870 $256,435 $256,435 Water Costs $111,900 $73,045 $38,854 Total $3,900,917 $1,717,336 $2,222,435 Table 4: Projected running cost savings for the project. Photo 1: Compressor sets in the ammonia machinery room. drum to the glycol chiller. In this configuration adding the heat recovery increased the charge by approximately 5%. The glycol cooling circuit was redesigned from the previous configuration. This reduced the total number of pumps from 20 to four, and introduced variable speed drives to all four pumps. The connected pump load is reduced from 221.5 kw to 155 kw, but the real saving comes from using the variable speed pumps in conjunction with two-port valve control at the cooling loads, allowing reduced flow operation in periods of light load. With the previous system, the fixed speed pumps ran continually on full load. Reducing the flow when demand is satisfied will drop the pump power consumption by about 75%. An energy analysis of the cost benefit of operating the heat recovery system, in comparison with using efficient gas-fired boilers for the full heating requirement, showed that the ammonia compressor absorbed power rises from 291 kw to 411 kw. At a cost of $0.13 kwh this represents an increase of $386 per day in electrical cost. However, this is offset by a reduction in gas-fired heating of 1,250 kw. At a cost of $0.05/kWh and assuming a 2 2 A S H R A E J o u r n a l F e b r u a r y 2 0 1 1

boiler efficiency of 90%, this is a reduction of $1,575 per day. The daily saving in running cost is around $1,182, which equates to about $394,000 per year assuming 8,000 hours running. A more significant saving is shown when comparing operating costs for the old system against the expected costs for the new system. This can be seen by comparing running costs for 2008 with the projected costs for 2011. These figures are achieved with the same production output in each year. As the capital cost of the project was just over $6.3 million, this shows that reduced carbon emissions and elimination of R-22 have been achieved on a project with a simple payback of three years. Initial experience in running the system through the summer of 2010 shows the projected running costs for 2011 are perhaps pessimistic, suggesting that the savings will be even higher than predicted. Conclusions The cost savings in the confectionery factory project were achieved by: Improving the coefficient of performance of the chillers; Improving the energy efficiency of the cold glycol distribution circuit; Exchanging inefficient heating and steam distribution system; and Coupling the heating and cooling demands of the building to make use of extracted heat. The key factor in discovering and exploiting the savings is to look for places where fossil fuel is being burned to provide heat, but the end delivery of the heat is in the 100 F to 200 F (38 C to 93 C) range. In many cases, heat recovery is not considered because the heat distribution is provided by a low pressure steam system and the refrigeration system does not deliver recovered heat at high enough temperatures to raise steam. However, the losses in the steam delivery system were a significant proportion of the total heating bill. Using steam to distribute heat required at lower temperatures is convenient if the temperatures required to make steam are available from a combustion plant, but it is ultimately an inefficient method of providing low to medium grade heat. Significant operating cost reductions can be achieved by taking some of the heat loads off the steam circuit. The balance between capital and operating costs was struck at a point that took a significant proportion of the heating requirement as recovered heat from the cooling circuit, but blended this with heat from boilers rather than seeking to meet the total demand from one source. This approach (thermal coupling) is suited to a range of applications, and could be scaled down from the system described here to suit installation in a wide range of industrial and commercial buildings. 2 4 A S H R A E J o u r n a l F e b r u a r y 2 0 1 1