Flexit air handling unit K2 R



Similar documents
Flexit SPIRIT K2R. Air handling unit with integrated kitchen hood

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

FLEXIT S4 R S6 R S7 R

News! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment

94122E FLEXIT L4 X/TT L7 X/TT. User Manual. Air Handling Unit Loft Models with Heat Recovery

94210E L7 X W. User Manual. Air Handling Unit Loft Models with water-based heating

111538E Flexit SPIRIT UNI 2. Installation Instructions. Air Treatment Unit & Automatic Control

FLEXIT S3 X/TT A3 X/TT K3 X/TT S3 R S3 RK

Flexit Central Vacuum Cleaner

Flexit Central Vacuum Cleaner

ECOCIAT. Domestic hot water heat recovery unit

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

Installation, operation and maintenance manual TX 35A

Combi Unit Genius. The energy efficient Building Service Centre

RRV934. Multi-controller. Synco living

Installation and maintenance instructions. Danfoss Vent

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

HVAC Processes. Lecture 7

Horizontal ventilation units

The compact unit series

121MC. Vallox. Low-energy ventilation unit with heat recovery. Operating, maintenance and technical instructions. Vallox EN 14.5.

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

squrboxbox heat recovery squrboxbox I technical information

IH E Sigma Island 90

air conditioners how to choose a cooling system

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

Energy Efficiency HOSPITALITY.

8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

york air-conditioning products Residential & VRF News 2015

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Zehnder Focus 200. Ventilation device

Industrial infrared heater IR For premises with large volumes and high ceilings

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

eq Top/TopMaster Air Magic by Fläkt Woods

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

FLAT TECHNICAL DATA. HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS. indoor air quality and energy saving ENERGY CLASS B A A B A A UNIT

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

saving energy in comfort Factsheet Recair Enthalpy

LOCAL AIR-CONDITIONERS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

4 Alarm and info. Alarm. Yes Warning. No Information No Reset alarms > No Current list > Alarm log list > Delete alarm log > No

Heat Recovery based on Exhaust Air

CRAC Precision climate control units for data centres

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

ComfoAir 350 Luxe User Manual

Energy Efficiency. Bars & RestauRants.

Meaco 30L and Meaco 40L dehumidifier instruction manual

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

DUCTED AIR CONDITIONING SOLUTIONS

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

CE6500 Energy Recovery Ventilator

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Delivering exceptional performance and Ecovalue. Ecocent

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

User's Instructions. Alpha HE CB25/33 and HE SY25

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS

Infrarot-Bewegungsmelder IP44

Energy saving tips for home

about your house How to Get the Ventilation That You Need in Your House Figure 1 Infiltration and exfiltration of air in a house

Triple M1 The new MiniVent family. The professionals choice

Under sill units. Type FSL-B-ZAS

HEATER, AIR CONDITIONING AND VENTILATION

Smoke exhaust systems

Variable Air Volume - VAV

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

DESIGN & TECHNICAL MANUAL

FULL DC INVERTER SYSTEMS

Supplying. your home with. Our wall-mounted ventilator range: flexible, powerful ventilation technology for a healthy environment.

Operation and Installation Manual. Max Series

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

HDA

WHOLE-HOUSE VENTILATION SYSTEMS

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

How To Make Your House Breathe

Topvex SX/C, Topvex TX/C. Air Handling Unit

LG Electronics AE Company, Commercial Air Conditioning

Unico Inverter. Unique and efficient.

Installation Guide. DEVIreg 530. Electronic Thermostat.

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

You make dreams a reality. We provide the efficient Air-Conditioning.

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Transcription:

Flexit air handling unit K2 R with integrated kitchen hood PATENTED The quietest on the market Modern design Energy-efficient Installation in the kitchen A FOR A HEALTHY ENVIRONMENT

Requirement-controlled ventilation the right amount of air at the right time In addition to high efficiency and low SFP, energy-efficient ventilation is also about supplying the right amount of air at the right time. Flexit s new automatic control system has been developed to make it easier to operate the user interface correctly. It is also possible to use a number of control options such as timer, CO2, pressure sensor, humidity sensor and the presence of people. Ensure a good indoor environment and low energy consumption. K2R in apartment: C02-sensor Wireless control panel CI60 or CI 600 (advanced) in a separate location in dewelling for simple control and monitoring of the ventilation system. Bedroom Bedroom Hall Living room Humidity sensor (110987) in bathroom and wet room sends a signal to the unit regarding the humidity level in the room. Increase ventilation to max setting. Parallel connection if several sensors. Bathroom/ toilet Kitchen open solution Motion sensor (09390) in living room sends a signal to the unit to increase ventilation to max setting. Parallel connection if several sensors. Humidity sensor Motion sensor CO 2 -sensor (110991) in living room sends a signal to the unit regarding the contamination level in the room. Ventilation is adjusted as required. Parallel connection if several sensors. Air handling units in kitchen. It is equipped with low-enery fans, a high-efficiency rotor recovery system and fine filters. the control system regualtion as required. Wireless control panel (113243) for forcing (max) ventilation. It can be positioned near the bathroom for accessibility. Simple retrofitting without laying cables. Explaination of color codes in ventilation system: Extract air. Supply air. Exhaust air. Outdoor air. See www.flexit.com for more information. Fireplace requires an adequate air supply to ensure a good updraught and prevent smoke from coming into the room. Wireless control panel (113243) for increasing the air supply if a fireplace is used. It can be positioned near the fireplace for accessibility. Simple retrofitting without laying cables. 2

Control panels With our control system the ventilation system can be controlled automatically or the system can be adjusted directly. There are two control panels to choose from. Both are in attractive design with user-friendly operation. The panels are in white or black. CI 600 CI 600 has lots of extra refinements and control options. In addition to the standard functions on the CI 60, the CI 600 has the following features: Timer function High-resolution colour display with text and symbols Cooling control Extract air control Modbus possibilities The panel displays indoor and outdoor air temperature. Functions and alarms appear on the display with help messages. The panel is the right size to fit a single wall box and comes with a low-voltage cable for connection to the unit. If ventilation needs to be controlled from several places in the dwelling, a CI 60 panel and wireless forcing switch can be used. CI 60 CI 60 control panel has all the necessary control functions. It is possible to adjust and control speed and temperature on the panel. The panel gives a signal if there is a fault in the unit or the filter needs changing. The panel is the right size to fit a single wall box and comes with a low-voltage cable for connection to the unit. Several panels can be connected if ventilation needs to be controlled from several places in the dwelling. CI 600: The panel displays: - Time and date - Outdoor air temperature - Room temperature - Current speed of ventilation unit - Daily/weekly timer active - Additional heating activated/ deactivated CI 60: The air handling unit is adjusted on the control panel. The picture shows the control panel open. 3

Product description Flexit SPIRIT K2R is an air handling unit with a rotating heat recovery system and integrated kitchen hood. The product is installed in the kitchen above the hob and is suitable for new and existing flats, studio flats, terraced houses and small detached houses. The unit have EC fans. The unit has two F7 compact filters. The supply air passes via ducts and valves to living rooms and bedrooms. The extract air is extracted either from the same room or via door gaps/overflow gratings to toilets and wet rooms. The used air passes via the duct system back to the unit, emits heat and is blown out of the building via a roof hat, combi-box or wall grating. Flexit SPIRIT K2R is fitted with an efficient rotating heat recovery system. The rotor unit has a high efficiency and meets the heating requirements for the ventilation air for most of the year. The cold outdoor air passes through one half of the rotor and the warm extract air passes through the other half. With this principle, a large part of the heat in the extract air will be transferred to the supply air. Spirit K2 is designed with a pressure fan for supply air and a suction fan for extract air to avoid odour transfer. Both extract air and supply air are filtered so that pollution does not come into contact with the rotor material. The moisture in the extract air accompanies the air out in the exhaust duct and out of the building. The rotor technology does not require condensation drainage. This means simpler installation. The unit has an electronic control that automatically switches the recovery function off/on in relation to the outdoor temperature. If the outdoor temperature is extremely low, a heating element will ensure that the supply air has the desired temperature. When there is no need for recovery (for example in the summer), the rotor will stop. 3 2 7 8 5 9 (Left model shown. The right model is inverted.) Outdoor Supply Extract Exhaust air air air air 4 1 6 11 10 General view (rotary wheel heat exchanger) 1 (FI2) Extract air filter F 7 2 (FI1) Supply air filter F 7 3 (EB1) Heating element 4 (F10-20) Overheating thermostat (Reset) 5 (M1) Supply air fan 6 (M2) Extract air fan 7 (HR-R) Rotary wheel-type heat exchanger 8 (M4) Rotor motor 9 Control unit 10 Kitchen hood 11 Adjustment switch 12 Damper adjustment Cleaning and filter changes Changing the filters regularly and cleaning the fans ensure that the air handling unit works optimally. Cleaning is simple if you follow the description in the user manual. The fat filter in the kitchen hood absorbs fat and food odours from food preparation. The fat filter must be cleaned regularly and can be cleaned in a dishwasher. The air handling unit has two filters that filter out outdoor pollution and protect the rotor from dirt. Filters must be replaced as required, once or twice a year. Filter replacement is easy. Open the front and change to a new filter. Flexit Spirit K2R seen from below. The fat filter and glass for the compact fluorescent tube can be easily detached. With a Flexit filter subscription, filters are sent directly to the address you specify. Read more about filter subscriptions at www.flexit.no. The filters for the air handling unit are easily accessible and can be easily replaced. 4

Flexit SPIRIT K2R Art.no. Type (EC -fans) 700014 K2 RER W Right model, white 700015 K2 RER S Right model, silver 700016 K2 REL W Left model, white 700017 K2 REL S Left model, silver Control panels Art.no. Type 09410 CI 60 Control panel, black 09411 CI 60 Control panel, white 09415 CI 600 Control panel, with timer function, black 09416 CI 600 Control panel, with timer function, white Accessories Art.no. Type 12767 Filter set, F7/F7 110362 Filter, kitchen hood 110987 Humidity sensor 110991 CO 2 -sensor 09861 Fire-/smoke detector 09390 SP 450 Motion detector 113243 Forcing switch, wireless (complete set) 113244 Forcing switch, extra 111156 Temperature sensor, NTC 111647 Modbusadapter CI 66 102405 Tettemansjett Ø125 102406 Sealing Sleeve Ø160 112727 Combi device V13 2x125mm, black 112728 Combi device V13 2x125mm, white 112729 Combi device V13 2x160mm, black 112730 Combi device V13 2x160mm, white 09862 Damper for ventilation throug kitchen hood Kitchen hood without vol.glass 110058 Profil list, white 110059 Profil list, silver CI 60 CI 600 If you want to control the unit from multiple locations, order extra control panels. Filter set (F7/F7) Humidity sensor Fire-/smoke detector Damper Forcing switch, wireless Temperature sensor Sealing Sleeve Filter, kitchen hood CO 2 -sensor Motion detector Forcing switch extra Modbusadapter Combi device Duct covers When duct goes stright up. Covers height 215-380mm. 09863 Duct cover, white 09864 Duct cover, silver When duct goes to the side. Covers height 215-380mm. 09865 Duct cover, white 09866 Duct cover, silver Profil list Film 5 Duct cover, Duct cover, open

Technical data K2 R Energyclass A Rated voltage 230 V/50 Hz Fuse 10 A Rated current, total 3,9 A Rated power, total 870 W Rated power, electric batteries 700 W Fan power 2 x 74 W Rated power, rotormotor 3 W Fan type F-wheel Fan motor control 0-10 V Max. fan speed 1 970 rpm Automatic control standard CS 60 Osoppfang 75% ved 140 m 3 /h Filter type (SUP/EXTR) F7/F7 SUP filter dimensions (WxHxD) 130x335x50 mm EXTR filter dimensions (WxHxD) 130x335x50 mm Weight 56 kg Duct connection Ø 125 mm (female) Height (without glass screen and bosses) * 700 mm Width 598 mm Depth (including glass screen) * 510 mm Lighting, compact fluorescent tube 11 W/G23 * See dimensioned drawing on next page. Symbols Used These products have a number of symbols that are used to label the product itself and in the installation and user documentation. SUPPLY AIR EXTRACT AIR EXHAUST AIR OUTDOOR AIR EXAMPLE OF NIPPLE LOCATIONS (shown as a right model) 6

System drawing Outdoor air Supply air Extract air Exhaust air System drawing (electric battery) B1 B1 EB1 Supply air temperature sensor Heating element F10 Overheating thermostat, manual reset FI1 EB1 F10 FI2 F20 FI1 Overheating thermostat, automatic reset Supply air filter F20 FI2 Extract air filter M1 Supply air fan HR-R M4 M2 Extract air fan HR-R Rotary wheel-type heat exchanger M1 M2 M4 K Rotor motor Kitchen hood DA4 Damper DA4 K Dimensioned drawing 371 84 (Shown as a left model) 371 84 (Shown as a right model) 229 229 129 129 227 227 514 514 7

Capacity diagram, sound data, specifications - K2R EC Supply air side (with F7 filter) Supply air side Air flow rate [l/s] Yellow field: SFP < 0,75 per fan 20 40 60 80 SFP < 0,75 400 80 Contact resistance [Pa] 350 70 100% 300 60 250 50 200 40 80% 100% 150 30 60% 100 80% 20 40% 50 60% 10 40% 0 0 40dB(A) 45dB(A) 50dB(A) 55dB(A) 60dB(A) 63dB(A) Air flow rate [m³/h] 0 50 100 150 200 250 300 350 Power Consumption [W] Extract air side (with F7 filter) Extract air side Yellow field: SFP < 0,75 per fan Air flow rate [l/s] 20 40 60 80 SFP < 0,75 400 80 350 100% 70 Contact resistance [Pa] 300 250 200 150 100% 80% 60 50 40 30 Power Consumption [W] 100 80% 60% 20 50 0 60% 40% 40% 40dB(A) 45dB(A) 50dB(A) 55dB(A) 59dB(A) 10 0 0 50 100 150 200 250 300 350 Air flow rate [m³/h] Correction factor for Lw Hz 63 125 250 500 1000 2000 4000 8000 LwA Supply air 14 12 1-6 -7-15 -22-26 Extract air 14 13 0-5 -10-16 -25-28 Radiated 1-4 -7-12 -19-27 -32-32 -34-16 Radiated 2 3-5 -17-23 -29-32 -37-35 -18 Sound data is given at sound power level LwA in the capacity diagrams and is corrected with the table below for the various octave bands. Radiated noise produces Lw in the various octave bands and total LwA. Radiated noise is calculated by taking the noise value from the supply air table and deducting the total value from the correction factor table. Radiated 1: K2 free hanging Radiated 2: K2 built-in kitchen 8

9

10

Our products are subject to continuous development and we therefore reserve the right to make changes. We also disclaim liability for any printing errors that may occur. 11

Flexit - the safe choice! Flexit specialises in home ventilation and delivers clean, fresh air solutions for a healthy indoor environment. Flexit is the market leader in home ventilation and has been supplying ventilation solutions to Norwegian homes since 1974. Flexit is a Norwegian company and all products are developed specially for the Nordic climate. Products are tested and documented in accordance with the latest standards. That gives you peace of mind! The SPIRIT range - energy efficient ventilation for a healthy indoor environment Stricter energy requirements in the regu lations and the new Passive House Standard demand efficient air handling units, and the SPIRIT range has been developed to meet that need. High targets for energy efficiency, quietness, user friendliness and quality characterise the whole range, and new models will be introduced in the future. All the models are equipped with high-effi ciency rotating recovery systems and have low-energy fans. Together with the new control system, this means that the SPIRIT range sets a new standard in home ventilation. A A A A A Flexit K2R It is a combined air handling unit with an integrated kitchen hood. It s specially designed for flats. It has a high-efficiency rotary recovery system and lowenergy fans. The unit is very quiet. Flexit C 2 Air handling unit with high-efficiency rotary recovery system, low-energy fans and control system. Design for flats and small dwellings. Flexit UNI 2 Air handling unit with high-efficiency rotary recovery system, low-energy fans and control system. Design for flats, small dwellings and passive houses. Flexit UNI 3 Air handling unit with high-efficiency rotary recovery system, lowenergy fans and control system. De signed for small dwellings, single-family houses, small office buildings and passive houses. Flexit UNI 4 Air handling unit with high-efficiency rotary recovery system, lowenergy fans and a new control system. Design for bigger homes, small office buildings and passive houses. SINTEF, working together with Flexit, has developed optimal technological solutions with the emphasis on energy efficiency and good indoor environment. The Norwegian Design Council, working together with Flexit, has conducted user surveys to ensure optimal user friendliness. Hareide Designmill has assisted Flexit with design development. Art.nr. 110216 01/2016 Phone +47 6981 0000 info@flexit.com www.flexit.com