40 Vacuum drying ovens



Similar documents
VDL 53 - Vacuum drying oven for flammable solvents

Vacuum drying oven for non-flammable solvents

Heating oven with mechanical convection

Heating oven with mechanical control

Material test chamber with mechanical convection

Incubator with mechanical convection

VACUUM HEATING AND DRYING OVENS Gentle and safe

Climate chamber with illumination

Thermo Scientific Heraeus Heating and Drying Ovens. Quality that meets every laboratory need

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

Clinic Washer-Disinfectors. Washer-Disinfector Line

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

Product-friendly and fast...

Freezers - Ultrafreezers. Platilab & Irilab Series

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Thermo Scientific Heratherm Microbiological Incubators. Safe,

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

CRAC Precision climate control units for data centres

VACUUM HEATING AND DRYING OVENS Gentle and safe

COMBIMASS. Technical Data COMBIMASS eco-bio +

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

Instruction Manual. T3111 T3111L T3111P T3111Ex

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Explosion-Proof Electric Unit Heaters

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Trocknungs_Prozess_engl_04_ :14 Uhr Seite 1 YOUR COMPETENT PARTNER. Drying- and Processing Technology

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

Power consumption (kw)

VACUUM HEATING AND DRYING OVENS Gentle, intelligent and safe

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Terminal Box. Specifications TNCN

Plastic tube flowmeters Series PT/PS

MEMBRANE VACUUM MINI PUMPS

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

Laminar Flow Cabinets

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Technical Data. Dimensions

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Electro-pneumatic control valves

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Refrigeration Compressed Air Dryer Buran Ultrapulse

German engineering under high pressure

Scraper Passage Indicator. Electrical Indicator. Features

Hydraulic Control Solutions

TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series

Spray Booth Guideline

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

3/2-way Solenoid Valve, direct-acting, NC or NO

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Safety Storage Cabinets

HEAVY DUTY STORAGE GAS

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

TEMPERATURE MEASURING GALVANIC SEPARATORS CONVERTORS, PRESSURE MEASURING

Inductive sensor NI10-M18-Y1X-H1141

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Inductive slot sensor

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Integrated pressure measurement

Kompressoren. Adsorption Dryer AD

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Technical Data. Dimensions

Adsorption air dryers ADS 1 215

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

RPV - RP - RA air handling units

Rotary screw compressors kw 5,5 7, , bar MODULO

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Fast closing valve Series 75

Thyristor-controlled power supplies and battery chargers

ECOCIAT. Domestic hot water heat recovery unit

Diagram of components 2. Reducer..3

Compact pressure switch Flameproof enclosure Ex d Model PCA

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Photovoltaic Solar Energy Unit EESFB

PAINT BOOTH LIGHTING

CE6500 Energy Recovery Ventilator

OEM-EP Pressure Controllers

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

Cooling Capacity CFM in. w.c. (125 Pa)

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

UDSA - UDSBD unit heater

Technology for Vacuum Systems. Instructions for use

INTERNATIONAL STANDARD

ECOplus Solar Cylinder

Thermometer in stainless steel with capillary and switch contacts

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Transcription:

40 Vacuum drying ovens

Vacuum drying ovens 41 VD VDL Absolutely reliable drying. Drying with no residues, no danger of incrustation, no oxidation all under gentle cycle conditions. We have also developed a special customized safety concept for your individual requirements that sets new standards in safety, all while maintaining our usual perfect performance and quality. Semiconductors/Electronics Chemical industry Plastics

42 Vacuum drying ovens BINDER Vacuum drying ovens Facts you should know: Homogenous drying of samples Our patented APT.line air jacket system ensures uniform heat distribution throughout the interior, including thermal transfer to the integrated expansion rack supports. Here, the large contact surface assures optimum heat transfer to specimens through the slide-in racks. The result is an ideal, controlled drying process that complies with standards. Durability thanks to optimum corrosion protection Uncompromising quality: The inner chamber has an electropolished surface finish, and the patented slide-in racks, connections, and valves are all manufactured from heavy-duty, corrosion-resistant stainless steel, type V4A (1.4571)/ AISI 316 Ti. Homogenous heat transfer with the APT.line preheating chamber eliminates cold spots and prevents condensation and corrosion. Short drying processes Our Cross Flow Technology ensures a homogenous airflow throughout the interior. The injection of an inert gas into the air or gas flow, for example, creates uniform and homogenous convection throughout the interior space with upward flow from the bottom. Samples are dried quickly and efficiently Safety glass panel (ESG) Splinter protection panel (Polycarbonat) The BINDER Safety concept: maximum protection during project work Door sealing flame protection gasket - VDE tested door design for maximum safety: Our vacuum drying ovens have a flame-proof enclosure and a special safety-glass window with anti-splinter protection, flexibly suspended in the door frame. This provides extra safety and effectively eliminates the risk of implosion or explosion in the interior. - Inert gas connection: The inert gas inlet has a precision dosing valve for uniform gas distribution throughout the inner chamber, thus preventing formation of an flammable atmosphere. - Decoupling of electrical components: All electrical components are contained within a separate enclosure. This completely isolates them from the inner chamber to prevent ignition.

Vacuum drying ovens 43 Easy cleaning Fast and thorough cleaning is easy thanks to a seamless, smooth, stainless steel interior chamber without corners or obtrusive fittings. Maximum protection for projects involving flammable solvents - Flame protection gasket: The patented flame protection gasket actively prevents flames from escaping. Should a detonation occur, the flame protection gasket will prevent any fire. - Overpressure encapsulated instrument field: Solvent vapors are securely isolated from all electrical components. A constant flow of pressurized air or inert gas through the instrument housing provides a safe and non-flammable atmosphere. ± 25 mbar - Heat management: The heating system switches on based upon the prevailing pressure; this prevents a potential ignition in the event of flammable air mixtures. Heat is automatically switched off when the pressure exceeds 125 mbar. The heating system can be switched on only if the pressure is below 125 mbar VDL The BINDER one-source solution Binder VD series equipment is supplied with a customized vacuum pump in a separate vacuum module. This reduces noise levels by 50% and significantly simplifies drying oven access. Installation could not be easier, since the supplied kit contains all necessary fittings. Applications Requirements for installation EX-proof classification, pursuant to Directive 94/9/EC VD series Drying or heat treatment of specimens containing non-flammable solvents VDL series Drying of specimens containing flammable solvents that can form explosive mixtures with air (ATEX 95, ATEX 100a, 94/9/EC, EN 1539 Effective and continuous ventilation of the area where the equipment is installed. Equipment interior: II 3 G Temperature classification* pursuant to IEC 60079-14:1996 Equipment interior: T1*,T2* or T3* * The temperature classification of the equipment corresponds to that of the interior.

44 Vacuum drying ovens VD series: Vacuum drying ovens for non-flammable solvents The VD series offers safe drying with homogenous temperature distribution, thanks to its electronically controlled APT.line preheating technology. Optimum heat transfer through patented expansion rack technology; the racks can be positioned as needed and are easy to clean. Model VD 53 Performance features and equipment: - Electronically controlled APT.line preheating chamber technology - Temperature range: 15ºC (59ºF) above ambient temperature up to 200ºC (392ºF) - MP controller with 2 programs with 10 sections each, or alternatively one program with 20 sections - Integrated week program timer with real time function - Digital temperature setting with an accuracy of one degree - Elapsed time indicator - Fine dosing ventilation valve (at VD 23 the standard inert gas connection is also used as ventilation valve) - Fine dosing inert gas valve with cross-flow technology - All electrical components are decoupled from the interior chamber - Spring-mounted shatter proof safety glass panel - Independent adjustable temperature safety device, Class 2 (DIN 12880), with visual alarm - DN 16 measuring port in rear wall - Analog pressure gauge (display pressure difference between the inner chamber and the ambient pressure) - Electro polished inner chamber, suction and ventilation tubes, pressure container, and ball valve are made of stainless steel Mat. No. 1.4571 (V4A) / AISI 316 Ti - Door gasket made of tempered silicone - 2 x 24 V DC (max. 0.4 A) switching outputs, switched via 2 control contact of the program editor - RS 422 interface for communication software APT-COM DataControlSystem - 2 patented, flexible aluminum expansion racks - BINDER test certificate - available also as complete system, with vacuum module and vacuum pump Model VD 53

Vacuum drying ovens 45 Technical specification VD series Width (mm/inch) 515/20.28 634/24.96 740/29.13 Height (inclusive feet) (mm/inch) 655/25.79 775/30.51 900/35.43 Depth (mm/inch) 500/19.69 550/21.65 670/26.38 Height option vacuum module (mm/inch) 624/24.57 624/24.57 622/24.49 Total height with option vacuum module (mm/inch) 1279/50.35 1400/55.12 1522/59.92 plus door handle, connection (mm/inch) 100/3.94 100/3.94 100/3.94 Wall clearance rear (mm/inch) 100/3.94 100/3.94 100/3.94 Wall clearance side (mm/inch) 135/5.31 135/5.31 135/5.31 Width (mm/inch) 285/11.22 400/15.75 506/19.92 Height (mm/inch) 285/11.22 400/15.75 506/19.92 Depth (mm/inch) 285/11.22 330/12.99 450/17.72 Interior volume (l/cu.ft.) 23/0.81 53/1.87 115/4.06 Quantity of expansion racks (aluminum) (standard/max.) 2/4 2/5 2/6 Distance between the racks (mm/inch) 53/2.09 62/2.44 68/2.68 Usable space per rack (width x depth) (mm/inch) 234x280/ 9.21x11.02 349x320/ 13.74x12.60 455x440/ 17.91x17.32 Load per rack (kg/lbs.) 20/44 20/44 20/44 Permitted total load (kg/lbs.) 35/77 45/99 65/143 Weight of the unit (empty) (kg/lbs.) 63/139 95/209 153/337 Temperature range, 15 C/59 F above ambient up to C/ F 200/392 200/392 200/392 Temperature uniformity 1) at 100 C/212 F (± K) 1.5 2 3.5 at 200 C/392 F (± K) 3 4.5 9 Temperature fluctuation 1) (± K) 0.1 0.1 0.1 Heating up time 1) 2) Position II / POWER to 100 C (min.) 50 80 90 to 200 C (min.) 100 130 190 Vacuum connection with small flange (DN mm/inch) 16/0.63 16/0.63 16/0.63 Measuring access port with small flange (DN mm/inch) 16/0.63 16/0.63 16/0.63 Inert gas connection with flow limiter (RP") 3/8 3/8 3/8 Permitted end vacuum (mbar / inchhg) 0.01/0.000295 0.01/0.000295 0.01/0.000295 Leak rate max. (bar/h / inchhg/h) 0.01/2.95 0.01/2.95 0.01/2.95 Housing protection acc. to EN 60529 IP 20 IP 20 IP 20 Nominal voltage (±10 %) 50/60 Hz (V) 230 230 230 Nominal voltage (±10 %) 60 Hz (V) 115 115 115 Nominal power for 230 V units (kw) 0.8 1.2 1.9 Nominal power for 115 V units (kw) 0.8 1.2 1.7 Energy consumption at 100 C (W) 105 150 250 at 200 C (W) 280 445 785 1) values measured with aluminum racks 2) up to 98 % of the set-point value (main switch (1) in position II) All technical specification are specified for units with standard equipment at an ambient temperature of 25 ºC (77 ºF) and a voltage fluctuation of ±10 %. The temperature data are determinated in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10 % of the height, width and depth of the inner chamber. All values have been specified at a fan speed of 100 %. All indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times.

46 Vacuum Drying ovens VDL series: Safety vacuum drying ovens for flammable solvents The VDL series comes with a standard safety package that guarantees maximum safety for drying samples that contain organic solvents, complete with a TÜV/GS safety certificate. The interior chamber is designed in accordance with the ATEX Directive for Zone 2 operation. The equipment must be installed in a zone for nonhazardous activities. Model VDL 53 Performance features and equipment: - Electronically controlled APT.line preheating chamber technology - Temperature range of 15ºC (59ºF) above ambient temperature up to 200ºC (392ºF) - MP controller with two programs with 10 sections each, or alternatively one program with 20 sections - Digital temperature setting with an accuracy of one degree - Elapsed time indicator - Spring-mounted safety glass pane with splinter protection - Pressure monitor for controlled heating release at < 125 mbar (94 torr) - Over pressure capsulated instrument panel with compressed air connection and maintenance unit - Flame protection gasket - Fine dosing inert gas valve with cross-flow technology - Analog pressure gauge (display pressure difference between the inner chamber and the ambient pressure) - Electro polished inner chamber, suction and ventilation tubes, pressure container, and ball valve are made of stainless steel Mat. No. 1.4571 (V4A) / AISI 316 Ti - Door gasket made of tempered silicone - Independent adjustable temperature safety device, Class 2 (DIN 12880), with visual alarm - DN 16 measuring port in rear wall - RS 422 interface for communication software APT-COM DataControlSystem - 2 patented, flexible aluminum expansion racks - BINDER test certificate - available also as complete system, with module and vacuum pump Model VDL 53

Vacuum Drying ovens 47 Technical specification VDL series Width (mm/inch) 515/20.28 634/24.96 740/29.13 Height (inclusive feet) (mm/inch) 655/25.79 775/30.51 900/35.43 Height option vacuum module (mm/inch) 624/24.57 624/24.57 622/24.49 Total height with option vacuum module (mm/inch) 1279/50.35 1400/55.12 1522/59.92 Depth (mm/inch) 500/19.69 550/21.65 670/26.38 plus door handle, connection (mm/inch) 100/3.94 100/3.94 100/3.94 Wall clearance rear (mm/inch) 100/3.94 100/3.94 100/3.94 Wall clearance side (mm/inch) 135/5.31 135/5.31 135/5.31 Width (mm/inch) 285/11.22 400/15.75 506/19.92 Height (mm/inch) 285/11.22 400/15.75 Modell VDL 53506/19.92 Depth (mm/inch) 285/11.22 330/12.99 450/17.72 Interior volume (l/cu.ft.) 23/0.81 53/1.87 115/4.06 Quantity of expansion racks (aluminum) (standard/max.) 2/4 2/5 2/6 Distance between the racks (mm/inch) 53/2.09 62/2.44 68/2.68 Usable space per rack (width x depth) (mm/inch) 234x280/ 9.21x11.02 349x320/ 13.74x12.60 455x440/ 17.19/17.32 Load per rack (kg/lbs.) 20/44 20/44 20/44 Permitted total load (kg/lbs.) 35/77 45/99 65/143 Weight of the unit (empty) (kg/lbs.) 63/139 95/209 153/337 Temperature range, 15 C/59 F above ambient up to C/ F 200/392 200/392 200/392 Temperature uniformity 1) at 100 C/212 F (± K) 1.5 2 3.5 at 200 C/392 F (± K) 3 4.5 9 Temperature fluctuation 1) (± K) 0.1 0.1 0.1 Heating up time 1) 2) Position II / POWER to 100 C (min.) 50 80 155 to 200 C (min.) 100 130 200 Vacuum connection with small flange (DN mm/inch) 16/0.63 16/0.63 16/0.63 Measuring access port with small flange (DN mm/inch) 16/0.63 16/0.63 16/0.63 Inert gas connection with flow limiter (RP") 3/8 3/8 3/8 Permitted end vacuum (mbar / inchhg) 0.01/0.000295 0.01/0.000295 0.01/0.000295 Leak rate (max.mbar/h / inchhg/h) 10/0.295 10/0.295 10/0.295 Compressed air connection for pressure-encapsulation (Ø mm) 8 8 8 Housing protection acc. to EN 60529 IP 54 IP 54 IP 54 Nominal voltage (±10 %) 50/60 Hz (V) 230 230 230 1 Nominal power (kw) 0.8 1.2 1.9 Energy consumption at 100 C (W) 105 150 250 at 200 C (W) 280 445 785 1) values measured with aluminum racks 2) up to 98 % of the set-point value All technical specification are specified for units with standard equipment at an ambient temperature of 25 ºC (77 ºF) and a voltage fluctuation of ±10 %. The temperature data are determinated in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10 % of the height, width and depth of the inner chamber. All values have been specified at a fan speed of 100 %. All indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times.

48 Vacuum drying ovens VD series: Vacuum module with pump Series VD equipment can be supplied with an optional separate vacuum module that achieves up to 50% noise reduction. The chemical membrane pump for the vacuum module is available in three different versions, depending upon individual requirements. The speedcontrolled vacuum pump VP 3.1 or example, automatically adjusts to the various process conditions, which saves up to 30% time. Additional benefits: - excellent suction capacity even at low pressure - long service life because of oil-free operation - good chemical resistance, thanks to the extensive use of fluoroplastics Model VD 23 with module Nominal airflow 2.0 m³/h 3.4 m³/h 4.6 m³/h Final pressure 7 mbar 1.5 mbar 1.5 mbar Electrical connection (50 60 Hz) 230 V / 115 V 230 V / 115 V 230 V / 115 V VD 23 series VD 53 series VD 115 series option Technical specifications are subject to change.

Vacuum drying ovens 49 VDL series: Vacuum module with pump The vacuum module in the VDL series can be supplied with two different types of chemical membrane pumps, each of which have different intake and delivery capacities. Both models are ATEX compliant and have explosion-proof motors with integrated latching overload and thermal protection switches As of July 1, 2003, only ATEX-compliant equipment may be used in explosion hazard areas. All BINDER VDL series vacuum pumps are ATEX certified. Model VDL 53 with module ATEX approved according to ATEX Directive 94/9/EG yes yes Nominal airflow 1.9 m³/h 3.7 m³/h Final pressure 12 mbar 3 mbar Electrical supply (50 60 Hz) 230 V / 115 V 230 V / 115 V VDL 23 series - VDL 53 series - VDL 115 series Application details Approved ATEX-compliant membrane pump for VDL 23 and VDL 115 series Approved ATEX-compliant membrane pump with a reduced final vacuum for the VDL 115 series option - not available Technical specifications are subject to change.

50 Vacuum Drying ovens Options/accessories Measuring port Vacuum-tight (9-pin) bushing for instrument leads into the unit. Vacuum pump connection kit Our Plug&Play connection kits are designed to fit our entire line of pumps, and the antistatic ATEX connection kits comply with all required safety standards. ATEX certification requires antistatic connection kits. Specimen temperature indication PT 100 sensor with digital temperature display Digital pressure display The interior chamber pressure is measured with a permanently installed pressure sensor. The digital display is accurate to within 1 mbar (0.8 torr). Vacuum module As an option, Series VD and VDL equipment can be supplied with a separate vacuum module. This reduces noise levels by 50% and significantly simplifies access to the drying oven.

Vacuum Drying ovens 51 BINDER-Service Use a BINDER service plan to keep your vacuum drying ovens in top condition. In addition to calibrating your equipment, we will also perform a comprehensive safety inspection based upon DIN requirements. 23 53 115 23 53 115 Expansion racks, aluminum or stainless steel Connection kit with different small flanges Measurement port for air-tight lead-through of measurement lines into the unit (9-pin) Specimen temperature measurement via flexible PT100 sensor Digital pressure display - - - Factory calibration certificate Extention to factory calibration certificate door gasket, FKM (viton) Vacuum module with chemical membrane pump VP 1.1 - - - Vacuum module with chemical membrane pump VP 2.1 - - - Vacuum module with speed controlled chemical membrane pump VP 3.1 - - - Vacuum module with membrane pump VP 4 - - - Vacuum module with membrane pump VP 5 - - - - - Vacuum module option - not available