HiTrap Heparin HP, 1 ml and 5 ml



Similar documents
RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml

HiTrap Chelating HP, 1 ml and 5 ml

Blue Sepharose 6 Fast Flow

Process-scale purification of monoclonal antibodies polishing using Capto Q

HisTrap HP, 1 ml and 5 ml

HisTrap HP, 1 ml and 5 ml

His GraviTrap. GE Healthcare. Operation

HiTrap Affinity columns

INSTRUCTIONS Edition AC

MabSelect SuRe. GE Healthcare Life Sciences

Data File. Sephadex G-25 media and pre-packed columns. Introduction. Sephadex G-25 Bead structure. Desalting/buffer exchange and gel filtration

GE Healthcare. UNICORN 6.x. SQL Server 2008 configuration for UNICORN installations

UniFlux 10: hollow fiber conversion kit ( ) installation instruction

HiTrap affinity columns

Affi-Prep Protein A Matrix Instruction Manual

CU-950 Installation Guide

Prepacked chromatography columns for ÄKTA systems

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use

Gain efficiency in your process development with ÄKTA avant

GE Healthcare. UNICORN 5.2 vs Software Change Description

His Mag Sepharose excel. Ni Sepharose excel. HisTrap excel. gelifesciences.com

Amersham High Molecular Weight Calibration Kit for native electrophoresis

ÄKTA system Training Guide

Purification of GST-tagged Proteins

How to Download a GE Healthcare License File

ReadyKart Mobile Processing Station Instructions for Use

How To Test For Cleaning Efficiency With A Predictor 96 Well Filter Plate

Summary of GE Healthcare's Quality Management System (QMS) Covering BioProcess chromatography media, equipment, software, and spare parts

For in vitro preparation of human mononuclear cells from peripheral blood, bone marrow, and umbilical cord blood. Not for in vitro diagnostic use.

Instrument services for WAVE Bioreactor systems

soft ware change description

UNICORN. Hardening Guide

UNICORN 7.0 software. Description. gelifesciences.com

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual

GE Healthcare Life Sciences. Validation Services. Compliance support through life cycle management

illustra MicroSpin G-25 Columns

Page finder. 1. Legal Handling Safety warnings and precautions Storage Expiry 4

UNICORN control software

Glutathione Resin. User Manual. User Manual. Cat. Nos , , PT (071414)

HiPer Ion Exchange Chromatography Teaching Kit

GAMP5 - a lifecycle management framework for customized bioprocess solutions

Protein Purification Handbook

A novel AIEX chromatography medium (resin) to remove IgA and IVIG purification process

Fast Trak Training & Education

TECHNICAL BULLETIN. HIS-Select Nickel Affinity Gel. Catalog Number P6611 Storage Temperature 2 8 C

Purification of reaction mixtures using flash chromatography.

FPLC standard operating procedure AKTA system (GE)

Aurum Ion Exchange Mini Kits and Columns. Instruction Manual

Transforming a ChromLab Software 2-D Purification Template into an Automated Multidimensional (Multi-D) Purification Workflow An Instructional Guide

ÄKTA Laboratory-scale Chromatography Systems

Application Note. Separation of three monoclonal antibody variants using MCSGP. Summary

Ficoll-Paque PREMIUM Ficoll-Paque PREMIUM Ficoll-Paque PREMIUM 1.073

GE Healthcare. Hydrophobic Interaction and Reversed Phase Chromatography. Principles and Methods

Application Note. Increasing the activity of monoclonal antibody isoforms by MCSGP. Summary

Size Exclusion Chromatography

Classic Immunoprecipitation

Choose your optimal tools for protein studies

Expression. Labeling. Crystallization. Purification. 伯 森 生 物 科 技 股 份 限 公 司 Blossom Biotechnologies Inc. P. 8 P. 3 P. 5 P. 6 P. 6 P. 2 P. 7 P.

Connect Alias autosampler to ÄKTA pure or ÄKTA avant. Instructions

INSTRUCTION Probemaker

GE Healthcare s cell culture media, sera and process liquids

Efficient Multi-Well Protein Purification Strategies

105 Adopted:

50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.

Bio-Gel P Polyacrylamide Gel Instruction Manual

Ficoll-Paque PLUS. Ficoll-Paque. Intended Use For in vitro isolation of lymphocytes.

Affinity Chromatography

Protein purification methods, a practical approach

illustra puretaq Ready-To-Go PCR Beads

for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC)

Single-Use Flow-Through Cell ph FTC-SU-HP8

High-Throughput 3-D Chromatography Through Ion Exchange SPE

POROS CaptureSelect affinity columns for highspeed quantification of IgG Fc fusion proteins

3.3. NGC Chromatography Systems and ChromLab Software Instrument Guide Version 3.3

NimbleGen DNA Methylation Microarrays and Services

ÄKTAexplorer, ÄKTApurifier

Determination of Calcium and Magnesium in Brine

DENSITY MEASURING SYSTEMS

Ion Exchange Determination of Na+ by Displacement and Zn 2+ Using Preconcentration. Reading: Harris pp , 699

Diffusion and Fluid Flow

PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

UNICORN MS SQL Server Integration

Gel Filtration Standard

2D gel electrophoresis

UltraClean PCR Clean-Up Kit

Application Note. Purifying common light-chain bispecific antibodies using MCSGP. Summary

6 Characterization of Casein and Bovine Serum Albumin

Biacore S200. Main applications. GE Healthcare. Label-free interaction analysis

AFFINITY CHROMATOGRAPHY

Genomic DNA Extraction Kit INSTRUCTION MANUAL

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0)

C-100E Strong Acid Cation Exchange Resin (For use in water softening applications)

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

Application Note. USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u

Peptide Antibody Production

High-throughput Process Development with PreDictor Plates

Monoclonal Antibody Production: Building the Platform. Andrew Clutterbuck Eden Biodesign Ltd.

AxyPrep TM Mag PCR Clean-up Protocol

Transcription:

Instructions 71-7004-00 AU HiTrap affinity columns HiTrap Heparin HP, 1 ml and 5 ml HiTrap Heparin HP is a prepacked ready to use, column for preparative affinity chromatography. The special design of the column, together with the matrix, provide fast, simple and easy separations in a convenient format. The columns can be operated with a syringe, peristaltic pump or liquid chromatography system such as ÄKTA.

Table of contents 1. Product description...3 2. Operation...6 3. Purification...7 4. Scaling up...9 5. Adjusting pressure limits in chromatography system software..9 6. Storage... 11 7. Ordering information... 12 Please read these instructions carefully before using HiTrap columns. Intended use HiTrap columns are intended for research use only, and shall not be used in any clinical or in vitro procedures for diagnostic purposes. Safety For use and handling of the product in a safe way, please refer to the Safety Data Sheet. 2 71-7004-00 AU

1 Product description HiTrap column characteristics The columns are made of biocompatible polypropylene that does not interact with biomolecules. The columns are delivered with a stopper at the inlet and a snapoff end at the outlet. Table 1 lists the characteristics of HiTrap columns. Fig 1. HiTrap, 1 ml column. Fig 2. HiTrap, 5 ml column. Note: HiTrap columns cannot be opened or refilled. Note: Make sure that the connector is tight to prevent leakage. Table 1. Characteristics of HiTrap columns. Column volume (CV) 1 ml 5 ml Column dimensions 0.7 2.5 cm 1.6 x 2.5 cm Column hardware pressure limit 5 bar (0.5 MPa) 5 bar (0.5 MPa) Note: The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium, sample/liquid viscosity and the column tubing used. 71-7004-00 AU 3

Supplied Connector kit with HiTrap column Connectors supplied Union 1/16 male/ luer female Stop plug female, 1/16 Usage For connection of syringe to HiTrap column No. supplied For sealing bottom of HiTrap column 2, 5 or 7 1 Medium properties The nature of Heparin Sepharose High Performance makes it a very versatile tool for the separation of many proteins e.g., DNA binding proteins, growth factors, coagulation protein synthesis factors and steroid receptors. The ligand in Heparin Sepharose High Performance is a naturally occurring sulfated glucosaminoglycan which is extracted from the native proteoglycan of porcine intestinal mucosa. Heparin consists alternating units of uronic acid and D-glucosamine, most of which are substituted with one or two sulfate groups. The molecular weight of the polymer is distributed over the range 5 000 to 30 000. Heparin is covalently coupled to highly cross-linked agarose beads. The coupling method gives high capacity and high performance. The medium is stable over the ph range 5 to 10, and tolerates all commonly used aqueous buffers. The properties of the product are summarized in Table 2. 4 71-7004-00 AU

Table 2. HiTrap Heparin HP characteristics Ligand Heparin Degree of substitution ~10 mg heparin/ml medium Binding capacity ~3 mg antithrombin III (bovine)/ml medium Mean particle size 34 µm Bead structure Highly cross-linked spherical agarose Max. flow rates 1 4 ml/min and 20 ml/min for 1 ml and 5 ml column respectively Rec. flow rates 0.2 to 1 ml/min and 1.5 ml/min for 1 ml and 5 ml column respectively Chemical stability All commonly used buffers ph stability 2 Long term 5 to 10 Short term 5 to 10 Storage 4ºC to 30ºC in 20% ethanol 1 Water at room temperature 2 The ranges given are estimates based on our knowledge and experience. Please note the following: ph stability, long term refers to the ph interval where the medium is stable over a long period of time without adverse effects on its subsequent chromatographic performance. ph stability, short term refers to the ph interval for regeneration, cleaning-in-place and sanitization procedures. 71-7004-00 AU 5

2 Operation The column can be operated with a syringe, peristaltic pump or a chromatography system. Immobilized heparin has two main modes of interaction with proteins. It can operate as an affinity ligand; e.g., in its interaction with coagulation factors. Heparin has also a function as a high capacity cation exchanger due to its anionic sulphate groups. Recommended elution conditions for both cases is to increase the ionic strength. Elution using a continuous or step gradient with NaCl, KCl or (NH 4) 2SO 4 up to 1.5 to 2 M is most frequently used. Buffer preparation Water and chemicals used for buffer preparation should be of high purity. It is recommended to filter the buffers by passing them through a 0.45 µm filter before use. Recommended buffers:. Binding buffer: 10 mm sodium phosphate, ph ~7 Elution buffer: 10 mm sodium phosphate, 1-2 M NaCl, ph ~7 Sample preparation The sample should be adjusted to the composition of the binding buffer. This can be done by either diluting the sample with binding buffer or by buffer exchange using HiTrap Desalting, HiPrep 26/10 Desalting or PD-10 column. The sample should be filtered through a 0.45 µm filter or centrifuged immediately before it is applied to the column. 6 71-7004-00 AU

3 Purification The recommended flow rate for HiTrap Heparin HP is 0.1 to 1 ml/min or 1 to 5 ml/min for 1 ml or 5 ml column respectively. 1 Fill the syringe or pump tubing with binding buffer. Remove the stopper and connect the column to the syringe (with the provided connector), or pump tubing, drop to drop to avoid introducing air into the column. 2 Remove the snap-off end at the column outlet. 3 Wash out the preservative and equilibrate the column with 10 column volumes of binding buffer. 4 Apply the sample, using a syringe fitted to the luer connector or by pumping it onto the column. 5 Wash with 5 to 10 column volumes of binding buffer or until no material appears in the effluent. 6 Elute with 5 to 10 column volumes of elution buffer using a continuous or step gradient. 7 The purified fractions can be desalted using HiTrap Desalting, HiPrep 26/10 Desalting or PD-10 column if necessary (Table 3). Note: If a P-1 pump is used a max flow rate of 1 to 3 ml/min can be run on a HiTrap 1 ml column packed with Sepharose High Performance media. 71-7004-00 AU 7

Table 3. Prepacked columns for desalting and buffer exchange Column Code No. Loading volume Elution volume Comments Application HiPrep 26/10 Desalting HiTrap Desalting 17-5087-01 2.5 15 ml 7.5 20 ml Prepacked with Sephadex G-25 Fine. Requires a laboratory pump or a chromatography system to run. 17-1408-01 0.25 1.5 ml 1.0 2.0 ml Prepacked with Sephadex G-25 Superfine. Requires a syringe or pump to run. For desalting and buffer exchange of protein extracts (Mr > 5000). PD-10 Desalting PD MiniTrap G-25 PD MidiTrap G-25 17-0851-01 1.0 2.5 ml 1 1.75 2.5 ml 2 3.5 ml 1 28-9180-07 0.1 0.5 ml 1 0.2 0.5 ml 2 1.0 ml 1 28-9180-08 0.5 1.0 ml 1 0.75 1.0 ml 2 1.5 ml 1 Prepacked with Sephadex Up to 2.5 ml 2 G-25 Medium. Runs by gravity flow or centrifugation Up to 0.5 ml 2 Up to 1.0 ml 2 For desalting, buffer exchange, and cleanup of proteins and other large biomolecules (Mr > 5000). 1 Volumes with gravity elution 2 Volumes with centrifugation 8 71-7004-00 AU

4 Scaling up For quick scale-up of purification, two or three HiTrap Heparin HP 1 ml or 5 ml columns can be connected in series (backpressure will increase). It is also possible to scale up using the prepacked HiPrep Heparin 16/10 FF column (20 ml). This column is prepacked with Heparin Sepharose Fast Flow. Note: Heparin Sepharose Fast Flow is based on 90 µm beads and is another matrix compared to Heparin Sepharose High Performance (34 µm beads). It may therefore be necessary with some optimization of the purification method to get exactly the same purity of the target protein. 5 Adjusting pressure limits in chromatography system software Pressure generated by the flow through a column affects the packed bed and the column hardware, see Fig 3. Increased pressure is generated when running/using one or a combination of the following conditions: High flow rates Buffers or sample with high viscosity Low temperature A flow restrictor Note: Exceeding the flow limit (see Table 2) may damage the column. 71-7004-00 AU 9

pre-column pressure pressure over the packed bed post-column pressure Fig 3. Pre-column and post-column measurements. ÄKTA avant The system will automatically monitor the pressures (pre-column pressure and pressure over the packed bed, Δp). The pre-column pressure limit is the column hardware pressure limit (see Table 1). The maximum pressure the packed bed can withstand depends on media characteristics and sample/liquid viscosity. The measured value also depends on the tubing used to connect the column to the instrument. 10 71-7004-00 AU

ÄKTAexplorer, ÄKTApurifier, ÄKTAFPLC and other systems with pressure sensor in the pump To obtain optimal functionality, the pressure limit in the software may be adjusted according to the following procedure: 1 Replace the column with a piece of tubing. Run the pump at the maximum intended flow rate. Note the pressure as total system pressure, P1. 2 Disconnect the tubing and run the pump at the same flow rate used in step 1. Note that there will be a drip from the column valve. Note this pressure as P2. 3 Calculate the new pressure limit as a sum of P2 and the column hardware pressure limit (see Table 1). Replace the pressure limit in the software with the calculated value. The actual pressure over the packed bed (Δp) will during run be equal to actual measured pressure - total system pressure (P1). Note: 6 Storage Repeat the procedure each time the parameters are changed. Wash the column with 5 column volumes of 20% ethanol at 1 ml/min (HiTrap 1 ml column) or at 5 ml/min (HiTrap 5 ml column). Store the column in 20% ethanol at 4ºC to 30ºC. 71-7004-00 AU 11

7 Ordering information Product No. Supplied Code No. HiTrap Heparin HP 5 1 ml 17-0406-01 1 5 ml 17-0407-01 5 5 ml 17-0407-03 Related products No. Supplied Code No. HiPrep Heparin FF 16/10 1 20 ml 28-9365-45 HiTrap Desalting 1 5 ml 29-0486-84 5 5 ml 17-1408-01 100 5 ml 1 11-0003-29 HiPrep 26/10 Desalting 1 53 ml 17-5087-01 4 53 ml 17-5087-02 PD-10 Desalting Column 30 17-0851-01 1 Special package. Delivered on specific customer order. 12 71-7004-00 AU

Accessories Quantity Code No. 1/16" male/luer female (For connection of syringe to top of HiTrap column) Tubing connector flangeless/m6 female (For connection of tubing to bottom of HiTrap column) Tubing connector flangeless/m6 male (For connection of tubing to top of HiTrap column) Union 1/16 female/m6 male (For connection to original FPLC System through bottom of HiTrap column) Union M6 female /1/16 male (For connection to original FPLC System through top of HiTrap column) 2 18-1112-51 2 18-1003-68 2 18-1017-98 6 18-1112-57 5 18-3858-01 Union luerlock female/m6 female 2 18-1027-12 HiTrap/HiPrep, 1/16" male connector for ÄKTA 8 28-4010-81 design Stop plug female, 1/16 (For sealing bottom of HiTrap column) 5 11-0004-64 Fingertight stop plug, 1/16" 5 11-0003-55 Related literature Affinity Chromatography Handbook, Principles and Methods Affinity Chromatography Columns and Media Selection Guide Code No. 18-1022-29 18-1121-86 71-7004-00 AU 13

14 71-7004-00 AU

71-7004-00 AU 15

For your local office contact information, visit: www.gelifesciences.com/contact GE Healthcare Bio-Sciences AB Björkgatan 30 751 84 Uppsala Sweden www.gelifesciences.com/hitrap www.gelifesciences.com/protein-purification GE Healthcare Europe GmbH Munzinger Strasse 5, D-79111 Freiburg, Germany GE Healthcare UK Ltd Amersham Place Little Chalfont Buckinghamshire, HP7 9NA UK GE Healthcare Bio-Sciences Corp 800 Centennial Avenue P.O. Box 1327 Piscataway, NJ 08855-1327 USA GE Healthcare Bio-Sciences KK Sanken Bldg. 3-25-1, Hyakunincho Shinjuku-ku, Tokyo 169-0073 Japan GE, imagination at work and GE monogram are trademarks of General Electric Company. ÄKTA, HiPrep, HiTrap, MidiTrap, MiniTrap, Sephadex, and Sepharose are trademarks of GE Healthcare companies. 1991-2014 General Electric Company All rights reserved. First published 1991 All goods and services are sold subject to the terms and conditions of sale of the company within GE Healthcare which supplies them. A copy of these terms and conditions is available on request. Contact your local GE Healthcare representative for the most current information. imagination at work 71-7004-00 AU 00/2014