1 Aurum Ion Exchange Mini Kits and Columns Instruction Manual Catalog # Aurum AEX Mini Kits, 2 pk Aurum AEX Mini Kits, 10 pk Aurum AEX Mini Columns, 25 pk Aurum AEX Mini Columns, 100 pk Aurum CEX Mini Kits, 2 pk Aurum CEX Mini Kits, 10 pk Aurum CEX Mini Columns, 25 pk Aurum CEX Mini Columns, 100 pk For technical service, call your local Bio-Rad office, or in the US, call BIORAD ( )
2 Table of Contents Section 1 Introduction Section 2 Components Section 3 Storage Conditions Section 4 Necessary Supplies Section 5 Guidelines for Aurum Ion Exchange Columns..8 Section 6 Protocol Section 7 Troubleshooting Guide Section 8 Bibliography Section 9 Ordering Information
3 Section 1 Introduction Proteomics Sample Fractionation Sample preparation plays an ever-increasing role in proteomics research. Selective separation techniques prior to multidimensional analysis, such as 2-D gel electrophoresis, HPLC-MS, or HPLC-CE, can significantly improve the chances of resolving complex protein mixtures into their individual proteins. Among these techniques are anion exchange (AEX) and cation exchange (CEX) chromatography. Aurum AEX and CEX columns allow rapid fractionation of complex protein mixtures in only a few steps using the common technique of ion exchange chromatography. Ion Exchange Chromatography Ion exchange chromatography can be used to concentrate and purify proteins based on their ionic charge or isoelectric point (pi) at a given ph. At the isoelectric point of a protein, its net charge is zero. At a ph higher than the pi of the protein, the protein will be negatively charged and will bind to an AEX resin. At a ph lower than the pi, the protein will be positively charged and will bind to a CEX resin. When an ion is applied to an ion exchanger of opposite charge, it is adsorbed to the resin, while neutral ions or ions of the same charge are eluted in the flow-through fraction. Binding of the ions is reversible, and adsorbed molecules are commonly eluted with salt or a change of ph. Table 1. Choosing the appropriate column. Resin Type AEX CEX Protein of Interest Acidic Basic The choice of whether to use an anion or cation exchanger is determined mainly by the pi, and the relationship between ph and the activity or stability of the protein of interest. Once the type of ion exchanger is determined, the choice of buffer and ph is also determined by the relationship between ph and activity. Resins and Buffers Description Each Aurum AEX and CEX column contains 0.2 ml of UNOsphere Q or S support, unique media based on a proprietary polymerization process. Both the UNOsphere Q and S ion exchange media were developed to deliver efficient protein capture and high binding capacity. The Aurum AEX and CEX 1
4 columns have binding and elution buffers included to afford minimal handling and ease of use. The formulations for each of the buffers are outlined in Table 2. Table 2. Properties of Bio-Rad ion exchange resins. Aurum CEX Aurum AEX Resin type UNOsphere S UNOsphere Q cation support anion support Binding capacity 12 mg IgG*/column 36 mg BSA*/column Column bed volume 0.2 ml 0.2 ml Binding buffer 20 mm sodium acetate, ph mm Tris, ph 8.3 Elution buffer Binding buffer M NaCl Binding buffer+ 1.0 M NaCl *Binding capacity determined using IgG (UNOsphere S) and BSA (UNOsphere Q). Capacity will differ between proteins and will depend on the exact loading conditions. A broad range of buffer systems can be used with Aurum AEX and CEX columns, depending on the protein of interest or specific process required. The chemical stability and broad operating ph range of the UNOsphere ion exchange media allow the use of a variety of buffers. Buffers commonly used for AEX or CEX can be used in place of the provided buffers (see Table 3). The best results are achieved when buffering ions that have the same charge as the functional group on the ion exchanger are used, e.g., phosphate paired with a cation exchanger, or Tris paired with an anion exchanger. As a general rule, the ph of the experiment should fall within the buffering range of the chosen buffer (see Table 3). This permits use of the lowest possible buffer concentration while maintaining maximum buffering capacity. In most cases, a buffer concentration of 20 mm is recommended. 2
5 Table 3. Common buffers for ion exchange chromatography. Cation Buffering Range Anion Buffering Range Acetic acid Bicine Citric acid Bis-Tris HEPES Diethanolamine MES Diethylamine MOPSO L-histidine Phosphate Imidazole PIPES Pyridine TES Tricine Tricine Triethanolamine Tris Sample Preparation Proper adjustment of the sample ph and ionic strength is critical for consistent and reproducible chromatography. For best results, the sample should be exchanged into the loading buffer or diluted to the buffer s concentration. Buffer exchange can be accomplished using Micro Bio-Spin 6 (catalog # ) or Bio-Spin 6 (catalog # ) columns, Econo-Pac Bio-Gel P-6 cartridges (catalog # ), or Econo-Pac 10DG desalting columns (catalog # ). The correct product to use will be determined by the volume of the sample. Always centrifuge or filter the sample ( µm filter) to remove particulates. Use of Aurum Ion Exchange Columns to Concentrate Protein Solutions The Aurum AEX and CEX columns are not only purification tools but also can be used to concentrate target proteins of interest in dilute solutions, a critical factor for subsequent analyses such as 2-D electrophoresis. Protein solutions of mg/ml can be concentrated fold using the appropriate resin with little loss of protein. 3
6 Table 4. Enrichment of typical proteins with Aurum AEX and CEX columns. Initial Solution Final Solution Resin Protein Volume Concentration Enrichment Recovery AEX BSA 30 ml 0.1 mg/ml 70 fold 90% CEX Cytochrome c 30 ml 0.2 mg/ml 60 fold 95% Bovine serum albumin (BSA) and cytochrome c were dissolved in buffer* and 30 ml loaded on an Aurum AEX or CEX column, respectively, in 1 ml aliquots. No protein was detected in the unbound fractions. The columns were eluted with 2 x 300 µl washes* containing 1 M NaCl. Protein concentrations were determined using the DC protein assay. *BSA dissolved and washed in 20 mm Tris, ph 8.3; cytochrome c dissolved and washed in 20 mm sodium acetate, ph 5.0 Ability to Purify Proteins of Differing pl Three proteins, ovalbumin (MW 45,000, pi 4.6), conalbumin (MW 77,000, pi 6.9), and cytochrome c (MW 12,000, pi 10.7), were completely separated using Aurum CEX and AEX columns in tandem. The respective unbound and bound fractions were analyzed by 4 20% SDS-PAGE (Figure 1). The three proteins were equilibrated in 20 mm sodium acetate buffer, ph 5.0, and applied to the CEX column. At this ph, the ovalbumin (pi 4.6) passed through the column while the conalbumin (pi 6.9) and cytochrome c (pi 10.7) remained bound to the column. The bound fractions were then eluted with elution buffer, desalted, buffer exchanged into 20 mm Tris, ph 8.3, and then applied to the AEX column at ph 8.3. The conalbumin remained bound while the cytochrome c was recovered in the unbound fraction. All three proteins were recovered with an estimated purity of >95% and a total recovery of >90%. 4
7 250 kd Conalbumin Ovalbumin Cytochrome c Fig. 1. Separation of three test proteins on Aurum AEX and CEX columns. The Aurum CEX column was equilibrated in 20 mm sodium acetate buffer, ph 5.0. The mixture of three proteins (lane 3, 0.4 ml at 30 mg/ml total protein) was added to the column. The unbound protein containing ovalbumin was collected (lane 4). The bound fraction containing conalbumin and cytochrome c (lane 5) was eluted with 2 x 300 µl washes with 20 mm sodium acetate buffer, ph 5.0, containing 1 M NaCl. The eluates from the washes were desalted and buffer exchanged using Micro Bio-Spin 6 desalting columns (catalog # ) and applied to an Aurum AEX column. The unbound fraction containing cytochrome c was collected (lane 6), while the bound fraction containing conalbumin (lane 7) was recovered with 2 x 300 µl washes of 20 mm Tris, ph 8.3, containing 1 M NaCl. The fractions were assayed for protein using the Bio-Rad protein assay to determine protein recovery. Purity was estimated from SDS-PAGE analysis on a 4 20% linear gradient Criterion Tris-HCl gel (catalog # ). The gel was stained with Coomassie Blue. Bio-Rad Precision Plus Protein standards (catalog # ) are shown in lane 1. 5
8 Section 2 Components The Aurum ion exchange products contain the following components: 2 pk 10 pk 25 pk 100 pk Aurum AEX or CEX columns Collection tubes, 2.0 ml 15 * * * Plastic test tubes, 12 x 75 mm 2 10 AEX or CEX binding buffer 15 ml 50 ml AEX or CEX elution buffer 15 ml 50 ml Micro Bio-Spin 6 columns, 4 20 Tris buffer Instruction manual Protocol overview *Order catalog # , EZ Micro test tubes, 2 ml, 500 Order catalog # , Test tubes, 12 x 75 mm, 100/bag Section 3 Storage Conditions Solutions and columns should be stored at 4 C. Do not freeze. Shelf life is 12 months at 4 C. Section 4 Necessary Supplies Microcentrifuge ( 10,000 x g) 6
9 AEX or CEX column 12 x 75 mm test tube 2.0 ml collection tube (only included in 2 pk) Micro Bio-Spin 6 column, Tris Fig. 2. Aurum ion exchange mini kit components 7
10 Section 5 Guidelines for Aurum Ion Exchange Columns All samples should be clarified before application to Aurum ion exchange columns. This can be accomplished using a 0.45 µm syringe filter or by centrifuging the sample at 10,000 x g for 5 min. For effective use of the Aurum ion exchange columns, the samples need to be adjusted to the approximate ph and ionic strength of the respective binding buffers. This can be accomplished in several ways. Depending upon the buffer of the sample, it may be sufficient to dilute the sample in the Aurum binding buffer. A second method would be desalting and buffer exchange using desalting columns. For small sample volumes, use Micro Bio-Spin or Bio-Spin desalting columns, and for larger volumes use Econo-Pac cartridges. A third alternative would be dialysis against the corresponding binding buffer. Sample loading will depend on the protein concentration of the sample and the protein capacity of the Aurum AEX or CEX column. If necessary, dilute samples can be concentrated using a SpeedVac concentrator or a lyophilizer. Knowledge of the pi of a protein of interest allows selection of resin type and buffer ph for either selective binding to or release from the resin. See Table 3 for buffer recommendations for the different Aurum AEX and CEX columns. Serum samples Serum can be diluted 1:4 in Aurum binding buffer and then ml applied to the ion exchange column. Using the recommended buffers, albumin will pass through the CEX column while binding to the AEX column. To selectively remove albumin and IgG from serum prior to ion exchange chromatography, use the Aurum serum protein mini kit (catalog # ), which can remove >90% of these two major proteins. To remove only the albumin, use Aurum Affi-Gel Blue columns (catalog # ). E. coli lysate For a typical E. coli lysate, dilute the lysate 1:4 in the appropriate binding buffer and load ml on the ion exchange column. Tissue culture samples Clarified tissue culture samples should be diluted or the buffer exchanged in binding buffer. For removal of bovine serum albumin added to culture media, use Aurum Affi-Gel Blue columns (catalog # ). 8
11 Bound proteins are eluted by increasing the salt concentration to 1 M NaCl. For some separations, varying the ph of the elution buffer in addition to its salt concentration may be advantageous. Aurum AEX and CEX columns show some differences in elution characteristics when eluted sequentially with different elution volumes. Table 5 shows the protein recovery in each of the three sequential elutions from both columns. Protein is more tightly bound to the CEX column, so larger elution volumes are required. Table 5. Protein recovery for AEX and CEX elution washes. Elution Volume 200 µl 300 µl 400 µl Column type AEX CEX AEX CEX AEX CEX % Protein Recovery st Wash % Protein Recovery nd Wash % Protein Recovery rd Wash BSA was bound to the AEX column in 20 mm Tris, ph 8.3, and eluted with 20 mm Tris, ph 8.3, containing 1 M NaCl. IgG was bound to the CEX column in 20 mm sodium acetate, ph 5.0, and eluted with 20 mm sodium acetate, ph 5.0, containing 1 M NaCl. The unbound fractions from the ion exchange columns can be used directly for 2-D gel electrophoretic analysis, provided the protein concentration is sufficient. For 2-D analysis, the bound fractions will require desalting. Micro Bio-Spin 6 columns (catalog # ) are recommended. For 2-D electrophoretic analysis, see bulletin 2651, 2-D Electrophoresis for Proteomics: A Methods and Product Manual. Fractions can be analyzed for protein using the Bio-Rad protein assay (catalog # , Bradford method) or the DC protein assay (catalog # ). See bulletin 1069, Colorimetric Protein Assays. If pi of protein is unknown We recommend running an IEF gel (catalog # ) to determine its pi. If the sample is not pure, we recommend visualizing the protein using an activity assay or identifying the protein with an immunoblotting assay. If the amino acid composition is known, the theoretical pi can be computed using databases available on the Internet, such as at 9
12 Section 6 Protocol Please read the section Guidelines for Aurum Ion Exchange Columns before proceeding. 1. Place an ion exchange column in a 12 x 75 mm test tube and allow the resin to settle for at least 5 min. 2. Remove the cap and break off the tip from the bottom of the ion exchange column. Return column to test tube. 3. Start gravity flow in the column and allow residual buffer to drain from the column (approximately 2 min). If the column does not begin to flow, push the cap back on the column and then remove it again to start the flow. 4. Once the residual buffer has drained, wash the column with 2 x 1 ml of the appropriate Aurum AEX or CEX binding buffer using gravity flow. Allow each wash to pass fully through the column and drain. 5. After the last wash, place the column in an empty 2.0 ml collection tube and centrifuge for 10 sec at 1,000 x g in a microcentrifuge to dry resin bed and frit. Do not overdry resin bed and frit. Discard the collection tube. 6. Place the column in a clean 2.0 ml collection tube labeled unbound. 7. Load the sample in the appropriate buffer onto the column and allow the sample to gravity filter through the column, collecting in the collection tube. If the column does not begin to flow, push the cap back on the column and remove it again to start the flow. 8. Place the column in another clean 2.0 ml collection tube. 9. Wash the columns with 0.3 ml of Aurum AEX or CEX binding buffer. Unbound fractions can be combined for further analysis if desired. Otherwise, unbound fractions can be discarded. 10. Place the column in a 2.0 ml collection tube and wash with 0.6 ml of the appropriate Aurum AEX or CEX binding buffer. Centrifuge column for 20 sec at 1,000 x g in a microcentrifuge, collecting the eluate in the tube. This wash can be discarded. 11. Place the column in a new 2.0 ml collection tube labeled bound # Add 0.3 ml of the appropriate Aurum AEX or CEX elution buffer to the top of the column and centrifuge for 10 sec at 1,000 x g. 13. Wash with an additional 0.3 ml of the Aurum AEX or CEX elution buffer into the same bound #1 tube. Centrifuge for 10 sec at 1,000 x g. 10
13 14. Place the column in a new 2.0 ml collection tube labeled bound # Wash with 0.3 ml of the Aurum AEX or CEX elution buffer. Centrifuge for 10 sec at 1,000 x g. Sample Preparation for IEF Using Micro Bio-Spin 6 Chromatography Desalting Procedure 1. Invert the column sharply several times to resuspend the settled gel and remove any bubbles. Snap off the tip and place the column in a 2.0 ml collection tube. Remove the top cap. If the column does not begin to flow, push the cap back on the column and remove it again to start the flow. Allow the excess packing buffer to drain by gravity to the top of the gel bed (about 2 min). Discard the drained buffer and place the column back into the 2.0 ml tube. 2. Centrifuge for 4 min in a microcentrifuge at 1,000 x g to remove the residual packing buffer. Discard the buffer. 3. Place the column in a clean 1.5 or 2.0 collection tube. Carefully apply the sample (20 75 µl) directly onto the center of the column. Application of more or less than the recommended sample volume may decrease column performance. 4. After loading sample, centrifuge the column for 4 min at 1,000 x g. 5. Following centrifugation, the purified sample is now in the low ionic strength binding buffer. Molecules smaller than the column s exclusion limit will be retained by the column. 6. Dispose of the used column. Buffer Exchange The gel in the Micro Bio-Spin columns is suspended in Tris buffer, ph 7.4. The gel matrix is compatible with most aqueous buffers. Buffer exchange can be achieved using the following procedure. 1. Follow steps 1 and 2 in the Desalting Procedure section. 2. Apply the new buffer in 500 µl aliquots. After each application of new buffer, let the buffer drain out by gravity, or centrifuge the column for 1 min to remove the buffer. Discard buffer from collection tube. Repeat as required. Three washes result in >99% of the buffer exchanged. Four washes result in >99.9% of buffer exchanged. 3. Sample can now be applied to the column as directed in steps 3 6 in the Desalting Procedure section. 11
14 Section 7 Troubleshooting Guide Problem Possible Cause Possible Solution Low protein Low levels of protein Increase load on column concentration in sample Concentrate sample in SpeedVac High protein High levels of protein Decrease the load concentration in sample applied to column Buffer does not flow Frit is clogged with Prefilter sample prior through column sample debris to loading Protein does not bind Incorrect column chosen CEX column is for to column basic proteins; AEX column is for acidic proteins Ionic detergents can prevent sample from binding Ionic strength too high ph not correct Avoid using detergents with opposing net charges to that of ion exchange column. Detergents can be removed using Bio-Beads SM-2 macroporous beads (catalog # ) Dilute sample or desalt Check ph of loading buffer Protein does not elute Salt concentration too Increase salt from column low in elution buffer concentration to 2 M and/or change ph Sample is dilute after Excess packing buffer Remove excess packing centrifugation was not removed buffer by centrifugation prior to loading sample 12
15 Section 8 Bibliography UNOsphere anion exchange support, Bio-Rad bulletin 2724 UNOsphere Q technical data, Bio-Rad bulletin 2729 UNOsphere cation exchange support, Bio-Rad bulletin 2669 UNOsphere S technical data, Bio-Rad bulletin 2678 UNOsphere Q and S ion exchange media instruction manual, Bio-Rad bulletin Sample preparation A guide to methods and applications, Bio-Rad bulletin D electrophoresis for proteomics: A methods and product manual, Bio-Rad bulletin 2651 Colorimetric protein assays, Bio-Rad bulletin 1069 Yamamoto S et al. (eds), Ion Exchange Chromatography of Proteins, Marcel Dekker, New York (1988) Beynon RJ and Easterby JS, Buffer Solutions: The Basics, IRL Press at Oxford University Press, Oxford, p 84 (1996) Burgett MW and Greenley LV, Cibacron Blue F3GA affinity chromatography, Amer Lab 9, (1977) Lindmark R et al., Binding of immunoglobulins to protein A and immunoglobulin levels in mammalian sera, J Immunol Methods 62, 1 13 (1983) Craft G et al., Comparison of Cibacron Blue affinity based formats for depletion of albumin from samples prior to two-dimensional gel electrophoresis, APAF poster (2002) 13
16 Section 9 Ordering Information Kits* Columns (Bulk)* 2 pk 10 pk 25 pk 100 pk Aurum AEX mini Aurum CEX mini Aurum Affi-Gel Blue mini Aurum serum protein mini Micro Bio-Spin 6, Tris *Kits include columns, buffers, and instructions. Columns include columns and instructions only. Cibacron is a trademark of Ciba-Geigy Corp. Coomassie is a trademark of Imperial Chemical Industries PLC. SpeedVac is a trademark of Savant Instruments, Inc. 14
17 Bio-Rad Laboratories, Inc Alfred Nobel Dr. Hercules, CA USA (510) Rev B
Affi-Prep Protein A Matrix Instruction Manual
Affi-Prep Protein A Matrix Instruction Manual Catalog Numbers 156-0005 156-0006 Bio-Rad Laboratories, 2000 Alfred Nobel Dr., Hercules, CA 94547 LIT-230 Rev B Table of Contents Section 1 Introduction...1
TECHNICAL BULLETIN. HIS-Select Nickel Affinity Gel. Catalog Number P6611 Storage Temperature 2 8 C
HIS-Select Nickel Affinity Gel Catalog Number P6611 Storage Temperature 2 8 C TECHNICAL BULLETIN Product Description HIS-Select Nickel Affinity Gel is an immobilized metalion affinity chromatography (IMAC)
Efficient Multi-Well Protein Purification Strategies
Application Note PN 33576 Efficient Multi-Well Protein Purification Strategies Introduction Many tools and techniques are available today for protein purification. Development of a purification process
HiPer Ion Exchange Chromatography Teaching Kit
HiPer Ion Exchange Chromatography Teaching Kit Product Code: HTC001 Number of experiments that can be performed: 5 Duration of Experiment: Protocol: 5-6 hours Storage Instructions: The kit is stable for
ProteoMiner Protein Enrichment Kits
ProteoMiner Protein Enrichment Kits Instruction Manual Catalog # 163-3003 163-3006 163-3007 163-3008 163-3009 163-3010 163-3011 163-3012 For Technical Support, contact your local Bio-Rad office, or in
ReadyPrep Protein Extraction Kit (Soluble/Insoluble) Instruction Manual. Catalog #163-2085
ReadyPrep Protein Extraction Kit (Soluble/Insoluble) Instruction Manual Catalog #163-2085 For technical service, call your local Bio-Rad office, or in the US, call 1-800-4BIORAD (1-800-424-6723) Table
Glutathione Resin. User Manual. User Manual. Cat. Nos. 635607, 635608, 635619 PT3306-1 (071414)
User Manual Glutathione Resin User Manual United States/Canada 800.662.2566 Asia Pacific +1.650.919.7300 Europe +33.(0)1.3904.6880 Japan +81.(0)77.543.6116 Cat. Nos. 635607, 635608, 635619 PT3306-1 (071414)
6 Characterization of Casein and Bovine Serum Albumin
6 Characterization of Casein and Bovine Serum Albumin (BSA) Objectives: A) To separate a mixture of casein and bovine serum albumin B) to characterize these proteins based on their solubilities as a function
ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual
ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual Catalog numbers 780-1070 780-1650 Please read these instructions before you use ENrich SEC high-resolution size exclusion
INSTRUCTIONS 56-1190-98. Edition AC
Sephacryl S-100 High Resolution Sephacryl S-200 High Resolution Sephacryl S-300 High Resolution Sephacryl S-400 High Resolution Sephacryl S-500 High Resolution INSTRUCTIONS Sephacryl High Resolution chromatography
UltraClean Soil DNA Isolation Kit
PAGE 1 UltraClean Soil DNA Isolation Kit Catalog # 12800-50 50 preps New improved PCR inhibitor removal solution (IRS) included Instruction Manual (New Alternative Protocol maximizes yields) Introduction
High-Throughput 3-D Chromatography Through Ion Exchange SPE
High-Throughput 3-D Chromatography Through Ion Exchange SPE Application Note 205 Luke Roenneburg and Alan Hamstra (Gilson, Inc.) Introduction 2-dimensional (2-D) separation is the separation of a sample
POROS CaptureSelect affinity columns for highspeed quantification of IgG Fc fusion proteins
APPLICATION NOTE POROS CaptureSelect affinity chromatography columns POROS CaptureSelect affinity columns for highspeed quantification of IgG Fc fusion proteins Introduction POROS columns, containing highperformance
RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml
GE Healthcare Life Sciences Instructions 71-7146-00 AI Ion Exchange Columns RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml Introduction RESOURCE Q and S are pre-packed columns for separating biomolecules
ReadyPrep Protein Extraction Kit (Cytoplasmic/Nuclear)
ReadyPrep Protein Extraction Kit (Cytoplasmic/Nuclear) Instruction Manual Catalog #163-2089 For technical service, call your local Bio-Rad office, or in the US, call 1-800-4BIORAD (1-800-424-6723) Bio-Rad
Optimal Conditions for F(ab ) 2 Antibody Fragment Production from Mouse IgG2a
Optimal Conditions for F(ab ) 2 Antibody Fragment Production from Mouse IgG2a Ryan S. Stowers, 1 Jacqueline A. Callihan, 2 James D. Bryers 2 1 Department of Bioengineering, Clemson University, Clemson,
Peptide Antibody Production
Peptide Antibody Production A) Peptide BioSynthesis (http://www.biosyn.com, 800-227-0627) B) Conjugation of peptide to KLH (Imject Maleimide Activated KLH, PIERCE=Thermo #77605, 10 mg) C) Peptide affinity
Gel Filtration Standard
Gel Filtration Standard Instruction Manual Catalog # 151-1901 Table of Contents Section 1 Introduction... 1 1.1 Instructions... 1 1.2 Recommended Volume of Standard... 2 1.3 Shelf Life... 5 1.4 Storage...
Guide to Reverse Phase SpinColumns Chromatography for Sample Prep
Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10
Bio-Gel P Polyacrylamide Gel Instruction Manual
Bio-Gel P Polyacrylamide Gel Instruction Manual Table of Contents Section 1 Introduction...1 Section 2 Technical Description...3 Section 3 Instructions for Use...6 3.1 Column Selection...6 3.2 Eluant Selection...6
Transforming a ChromLab Software 2-D Purification Template into an Automated Multidimensional (Multi-D) Purification Workflow An Instructional Guide
Transforming a ChromLab Software -D Purification Template into an Automated Multidimensional (Multi-D) Purification Workflow An Instructional Guide Instructional Guide Chromatography Bulletin 675 ChromLab
Plant Genomic DNA Extraction using CTAB
Plant Genomic DNA Extraction using CTAB Introduction The search for a more efficient means of extracting DNA of both higher quality and yield has lead to the development of a variety of protocols, however
An In-Gel Digestion Protocol
An In-Gel Digestion Protocol This protocol describes the digestion of a protein present in an SDS-PAGE gel band with trypsin. The band can be taken from either a 1D or 2D electrophoresis gel. Reagents
Wizard DNA Clean-Up System INSTRUCTIONS FOR USE OF PRODUCT A7280.
Technical Bulletin Wizard DNA Clean-Up System INSTRUCTIONS FOR USE OF PRODUCT A7280. PRINTED IN USA. Revised 4/06 AF9TB141 0406TB141 Wizard DNA Clean-Up System All technical literature is available on
Classic Immunoprecipitation
292PR 01 G-Biosciences 1-800-628-7730 1-314-991-6034 [email protected] A Geno Technology, Inc. (USA) brand name Classic Immunoprecipitation Utilizes Protein A/G Agarose for Antibody Binding (Cat.
Size Exclusion Chromatography
Size Exclusion Chromatography Size Exclusion Chromatography Instructors Stan Hitomi Coordinator Math & Science San Ramon Valley Unified School District Danville, CA Kirk Brown Lead Instructor, Edward Teller
GRS Plasmid Purification Kit Transfection Grade GK73.0002 (2 MaxiPreps)
1 GRS Plasmid Purification Kit Transfection Grade GK73.0002 (2 MaxiPreps) (FOR RESEARCH ONLY) Sample : Expected Yield : Endotoxin: Format : Operation Time : Elution Volume : 50-400 ml of cultured bacterial
EZ-Link Maleimide-PEO Solid Phase Biotinylation Kit: spin columns
INSTRUCTINS EZ-Link Maleimide-PE Solid Phase Biotinylation Kit: spin columns 3747 N. Meridian Road P.. Box 117 Rockford, IL 61105 21930 1476.1 Number Description 21930 EZ-Link Maleimide-PE Solid Phase
EZ-Run Protein Gel Solution. EZ-Run Protein Standards. EZ-Run Gel Staining Solution. Traditional SDS-Page Reagents. Protein Electrophoresis
EZ-Run Protein Gel Solution EZ-Run Protein Standards EZ-Run Gel Staining Solution Traditional SDS-Page Reagents Protein Electrophoresis protein electrophoresis Introduction Sodium dodecyl sulfate polyacrylamide
2D gel Protocol. 2. Determining Protein Concentration of cell lysates
2D gel Protocol 1. Lysis and Protein Extraction from cells Prepare cell lysates with Trizol extraction by following Kathleen Lyons s protocol: AfCS Procedure Protocol PP00000155, Version 1, 05/12/03 (Ref.1).
LAB 11 PLASMID DNA MINIPREP
LAB 11 PLASMID DNA MINIPREP STUDENT GUIDE GOAL The objective of this lab is to perform extraction of plasmid DNA and analyze the results. OBJECTIVES After completion, the student should be able to: 1.
Quick Start Bradford Protein Assay
Quick Start Bradford Protein Assay Instruction Manual For technical service call your local Bio-Rad office, or in the US, 1-800-4BIORAD (1-800-424-6723) Table of Contents Section 1 Introduction 1 1.1 Principle
EZ Load Molecular Rulers. Catalog Numbers 170-8351 20 bp 170-8352 100 bp 170-8353 100 bp PCR 170-8354 500 bp 170-8355 1 kb 170-8356 Precision Mass
EZ Load Molecular Rulers Catalog Numbers 170-8351 20 bp 170-8352 100 bp 170-8353 100 bp PCR 170-8354 500 bp 170-8355 1 kb 170-8356 Precision Mass EZ Load Molecular Rulers Quantity DNA sufficient for 100
PrepTip. Reverse Phase PrepTip User Guide
PrepTip Reverse Phase PrepTip User Guide All text, photographs and illustrations are copyrighted by Harvard Apparatus, Inc. 2004. PrepTip is a trademark of Harvard Apparatus, Inc. Harvard Apparatus 84
His GraviTrap. GE Healthcare. Operation
GE Healthcare Data File 11-0036-90 AB Affinity purification His GraviTrap His GraviTrap is a prepacked, single-use column for purification of histidine-tagged proteins by immobilized metal affinity chromatography
NimbleGen DNA Methylation Microarrays and Services
NimbleGen DNA Methylation Microarrays and Services Sample Preparation Instructions Outline This protocol describes the process for preparing samples for NimbleGen DNA Methylation microarrays using the
50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.
3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: 866-667-4362 (905) 227-8848 Fax: (905) 227-1061 Email: [email protected] Phage DNA Isolation Kit Product # 46800, 46850 Product Insert
Chem 405 Biochemistry Lab I Experiment 2 Quantitation of an unknown protein solution.
Chem 405 Biochemistry Lab I Experiment 2 Quantitation of an unknown protein solution. Introduction: The determination of protein concentration is frequently required in biochemical work. Several methods
HiTrap Heparin HP, 1 ml and 5 ml
Instructions 71-7004-00 AU HiTrap affinity columns HiTrap Heparin HP, 1 ml and 5 ml HiTrap Heparin HP is a prepacked ready to use, column for preparative affinity chromatography. The special design of
Western Blotting: Mini-gels
Western Blotting: Mini-gels Materials a Protein Extraction Buffer (for callus or kernel), Solution Stock Final Volume Tris-HCl ph 80 1 M 200 mm 20 ml NaCl 4 M 100 mm 25 ml Sucrose 2 M 400 mm 20 ml EDTA
Choose your optimal tools for protein studies
Protein Purification Choose your optimal tools for protein studies Bacterial Baculoviral Cell free Mammalian Secreted Intracellular High yield Increased solubility Highest purity Highest yield His-tag
The fastest spin-column based procedure for purifying up to 10 mg of ultra-pure endotoxin-free transfection-grade plasmid DNA.
INSTRUCTION MANUAL ZymoPURE Plasmid Gigaprep Kit Catalog Nos. D4204 (Patent Pending) Highlights The fastest spin-column based procedure for purifying up to 10 mg of ultra-pure endotoxin-free transfection-grade
Chromatin Immunoprecipitation
Chromatin Immunoprecipitation A) Prepare a yeast culture (see the Galactose Induction Protocol for details). 1) Start a small culture (e.g. 2 ml) in YEPD or selective media from a single colony. 2) Spin
Protein extraction from Tissues and Cultured Cells using Bioruptor Standard & Plus
Protein extraction from Tissues and Cultured Cells using Bioruptor Standard & Plus Introduction Protein extraction from tissues and cultured cells is the first step for many biochemical and analytical
Data File. Sephadex G-25 media and pre-packed columns. Introduction. Sephadex G-25 Bead structure. Desalting/buffer exchange and gel filtration
P H A R M A C I A B I O T E C H Sephadex G-25 media and pre-packed columns Data File Desalting/buffer exchange and gel filtration Reproducible desalting and buffer exchange in minutes with 90% 100% recovery
PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200
3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: 866-667-4362 (905) 227-8848 Fax: (905) 227-1061 Email: [email protected] PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System)
Genomic DNA Extraction Kit INSTRUCTION MANUAL
Genomic DNA Extraction Kit INSTRUCTION MANUAL Table of Contents Introduction 3 Kit Components 3 Storage Conditions 4 Recommended Equipment and Reagents 4 Introduction to the Protocol 4 General Overview
AG 501-X8 and Bio-Rex MSZ 501(D) Mixed Bed Resin Instruction Manual. Bio-Rad Laboratories, 2000 Alfred Nobel Dr., Hercules CA 94547 LIT205 Rev B
AG 501-X8 and Bio-Rex MSZ 501(D) Mixed Bed Resin Instruction Manual Bio-Rad Laboratories, 2000 Alfred Nobel Dr., Hercules CA 94547 LIT205 Rev B Introduction Mixed bed resins are used for deionizing water
Ubiquitin Interact Kit
Ubiquitin Interact Kit Item No. 15978 Customer Service 800.364.9897 * Technical Support 888.526.5351 www.caymanchem.com TABLE OF CONTENTS GENERAL INFORMATION 3 Materials Supplied 3 Precautions 4 If You
Lab 10: Bacterial Transformation, part 2, DNA plasmid preps, Determining DNA Concentration and Purity
Lab 10: Bacterial Transformation, part 2, DNA plasmid preps, Determining DNA Concentration and Purity Today you analyze the results of your bacterial transformation from last week and determine the efficiency
Protein Precipitation Protocols
Protein Precipitation Protocols Notes: All reagents need to high purity/hplc quality. All tubes used should be new or hand cleaned thoroughly with Micro90 detergent. High quality water needs to be used
Aurora Forensic Sample Clean-up Protocol
Aurora Forensic Sample Clean-up Protocol 106-0008-BA-D 2015 Boreal Genomics, Inc. All rights reserved. All trademarks are property of their owners. http://www.borealgenomics.com [email protected]
UltraClean PCR Clean-Up Kit
UltraClean PCR Clean-Up Kit Catalog No. Quantity 12500-50 50 Preps 12500-100 100 Preps 12500-250 250 Preps Instruction Manual Please recycle Version: 02212013 1 Table of Contents Introduction... 3 Protocol
DNA SPOOLING 1 ISOLATION OF DNA FROM ONION
DNA SPOOLING 1 ISOLATION OF DNA FROM ONION INTRODUCTION This laboratory protocol will demonstrate several basic steps required for isolation of chromosomal DNA from cells. To extract the chromosomal DNA,
Recombinant Enterokinase Kits
Table of Contents About the Kits...2 Description 2 Components 2 rek Cleavage...3 Small scale optimization 3 Scale-up 4 Monitoring cleavage 4 rek Capture...5 Capture buffer considerations 5 Monitoring rek
TIANquick Mini Purification Kit
TIANquick Mini Purification Kit For purification of PCR products, 100 bp to 20 kb www.tiangen.com TIANquick Mini Purification Kit (Spin column) Cat no. DP203 Kit Contents Contents Buffer BL Buffer PB Buffer
QIAGEN Supplementary Protocol
QIAGEN Supplementary Protocol Isolation of Peripheral Blood Mononuclear Cells (PBMC) and Purification of Total RNA from PBMC Using the RNeasy Micro or Mini Kit This protocol describes how to isolate PBMC
Electrophoresis and Electroblotting of Proteins
Electrophoresis and Electroblotting of Proteins The purpose of the next lab exercises will be to study the relative amounts of β-actin in cells of the B-16 melanoma, liver and muscle of mice. Electrophoresis
MLX BCG Buccal Cell Genomic DNA Extraction Kit. Performance Characteristics
MLX BCG Buccal Cell Genomic DNA Extraction Kit Performance Characteristics Monolythix, Inc. 4720 Calle Carga Camarillo, CA 93012 Tel: (805) 484-8478 monolythix.com Page 2 of 9 MLX BCG Buccal Cell Genomic
Oasis HLB Cartridges and 96-Well Plates
CONTENTS I. INTRODUCTION II. SAMPLE PRE-TREATMENT a. Biological Samples b. Solid Samples: Soil, Whole Foods, Tissue c. Aqueous Samples: Water, Beverages d. Non-Aqueous Liquid III. SOLID PHASE EXTRACTION
PureLink HiPure Plasmid Filter Purification Kits
USER GUIDE PureLink HiPure Plasmid Filter Purification Kits For Midi and Maxi preparation of Plasmid DNA Catalog numbers K2100-14, K2100-15, K2100-16, K2100-17, K2100-26, and K2100-27 Revision Date 2 May
Chromatin Immunoprecipitation (ChIP)
Chromatin Immunoprecipitation (ChIP) Day 1 A) DNA shearing 1. Samples Dissect tissue (One Mouse OBs) of interest and transfer to an eppendorf containing 0.5 ml of dissecting media (on ice) or PBS but without
Benchtop Mitochondria Isolation Protocol
Benchtop Mitochondria Isolation Protocol Note: Specific protocols are available for the following products: MS850 Mitochondria Isolation Kit for Rodent Tissue MS851 Mitochondria Isolation Kit for Rodent
Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates
Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates Paula Hong and Kenneth J. Fountain Waters Corporation, 34 Maple St., Milford, MA, USA APPLICATION
ELUTION OF DNA FROM AGAROSE GELS
ELUTION OF DNA FROM AGAROSE GELS OBTECTIVE: To isolate specific bands or regions of agarose-separated DNA for use in subsequent experiments and/or procedures. INTRODUCTION: It is sometimes necessary to
TECHNICAL BULLETIN. FluoroTag FITC Conjugation Kit. Product Number FITC1 Storage Temperature 2 8 C
FluoroTag FITC Conjugation Kit Product Number FITC1 Storage Temperature 2 8 C TECHNICAL BULLETIN Product Description The FluoroTag FITC Conjugation Kit is suitable for the conjugation of polyclonal and
About the Kits...2 Description 2 Components 2. Factor Xa Cleavage...3 Small scale optimization 3 Scale-up 3 Monitoring cleavage 4
Table of Contents About the Kits...2 Description 2 Components 2 Factor Xa Cleavage...3 Small scale optimization 3 Scale-up 3 Monitoring cleavage 4 Factor Xa Capture...5 Capture buffer considerations 5
WESTERN BLOTTING TIPS AND TROUBLESHOOTING GUIDE TROUBLESHOOTING GUIDE
WESTERN BLOTTING TIPS AND TROUBLESHOOTING GUIDE TIPS FOR SUCCESSFUL WESTERB BLOTS TROUBLESHOOTING GUIDE 1. Suboptimal protein transfer. This is the most common complaint with western blotting and could
Pure-IP Western Blot Detection Kit
Product Manual Pure-IP Western Blot Detection Kit Catalog Number PRB-5002 20 blots FOR RESEARCH USE ONLY Not for use in diagnostic procedures Introduction The technique of immunoprecipitation (IP) is used
AxyPrep TM Mag PCR Clean-up Protocol
AxyPrep TM Mag PCR Clean-up Protocol Intro The AxyPrep Mag PCR Clean-up kit utilizes a unique paramagnetic bead technology for rapid, high-throughput purification of PCR amplicons. Using this kit, PCR
Covalent Conjugation to Cytodiagnostics Carboxylated Gold Nanoparticles Tech Note #105
Covalent Conjugation to Cytodiagnostics Carboxylated Gold Nanoparticles Tech Note #105 Background Gold nanoparticle conjugates have been widely used in biological research and biosensing applications.
Genomic DNA Clean & Concentrator Catalog Nos. D4010 & D4011
Page 0 INSTRUCTION MANUAL Catalog Nos. D4010 & D4011 Highlights Quick (5 minute) spin column recovery of large-sized DNA (e.g., genomic, mitochondrial, plasmid (BAC/PAC), viral, phage, (wga)dna, etc.)
Rapid GST Inclusion Body Solubilization and Renaturation Kit
Product Manual Rapid GST Inclusion Body Solubilization and Renaturation Kit Catalog Number AKR-110 FOR RESEARCH USE ONLY Not for use in diagnostic procedures Introduction Bacteria are widely used for His
Process-scale purification of monoclonal antibodies polishing using Capto Q
GE Healthcare Life Sciences Application note 28-937-16 AB Ion exchange chromatography Process-scale purification of monoclonal antibodies polishing using Capto Q Summary Anionic exchange media are an industry
Western Blotting. USA: [email protected] UK & Europe: [email protected] China: [email protected]. www.ptglab.com
Western Blotting All steps are carried out at room temperature unless otherwise indicated. Recipes for all solutions highlighted bold are included at the end of the protocol. SDS-PAGE 1. Construct an SDS-PAGE
TECHNICAL BULLETIN. Bicinchoninic Acid Protein Assay Kit. Catalog Numbers BCA1 AND B9643
Bicinchoninic Acid Protein Assay Kit Catalog Numbers BCA1 AND B9643 TECHNICAL BULLETIN Synonym: BCA Product Description Protein determination is one of the most common operations performed in biochemical
Procedure for RNA isolation from human muscle or fat
Procedure for RNA isolation from human muscle or fat Reagents, all Rnase free: 20% SDS DEPC-H2O Rnase ZAP 75% EtOH Trizol Chloroform Isopropanol 0.8M NaCitrate/1.2M NaCl TE buffer, ph 7.0 1. Homogenizer-probe
ab185915 Protein Sumoylation Assay Ultra Kit
ab185915 Protein Sumoylation Assay Ultra Kit Instructions for Use For the measuring in vivo protein sumoylation in various samples This product is for research use only and is not intended for diagnostic
Page finder. 1. Legal 3. 2. Handling 4 2.1. Safety warnings and precautions 4 2.2. Storage 4 2.3. Expiry 4
GE Healthcare Amersham Low Molecular Weight Calibration Kit for SDS Electrophoresis A lyophilized mixture of six highly purified well-characterized proteins for use in molecular weight determination in
Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater
Document: AND Sol Env 08 2013 Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater Matrix specific sample preparation and testing methods for environmental waters
Purification of GST-tagged Proteins
Purification of GST-tagged Proteins User Manual Protino GST/4B Columns 1 ml Protino GST/4B Columns 5 ml January 2010 / Rev. 01 MACHEREY-NAGEL MN Table of contents 1 Components 4 1.1 Kit contents and storage
Analysis of Casein and Whey Protein in Whole, 2%, and Skim Milk by Capillary Gel Electrophoresis
Analysis of Casein and Whey Protein in Whole, 2%, and Skim Milk by Capillary Gel Electrophoresis Marcia Santos, Staff Applications Scientist, Beckman Coulter Life Sciences, Brea, CA USA Mark Lies, Marketing
Troubleshooting Guide for DNA Electrophoresis
Troubleshooting Guide for Electrophoresis. ELECTROPHORESIS Protocols and Recommendations for Electrophoresis electrophoresis problem 1 Low intensity of all or some bands 2 Smeared bands 3 Atypical banding
Two-Dimensional Gel Electrophoresis (2-DGE)
- Introduction - Sample preparation - First dimension: Isoelectric focusing - Second dimension: SDS-PAGE - Detection of protein spots: staining - Imaging analysis & 2D Gel databases - Spot handling: excision,
ISOLATE II PCR and Gel Kit. Product Manual
ISOLATE II PCR and Gel Kit Product Manual 2 Product Manual www.bioline.com/isolate PCR and Gel Kit ISOLATE II PCR and Gel Kit ISOLATE II PCR and Gel Kit 1 Kit contents 04 2 Description 04 3 Storage 04
POROS CaptureSelect affinity columns for rapid, small-scale purification and sample preparation of recombinant proteins
APPLICATION NOTE POROS CaptureSelect affinity chromatography columns POROS CaptureSelect affinity columns for rapid, small-scale purification and sample preparation of recombinant proteins Introduction
Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #: 3460-07
Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #: 3460-07 TABLE OF CONTENTS GENERAL INFORMATION... 2 Product Description... 2 Procedure Overview... 2 Kit Contents, Storage and Shelf Life... 3
PowerFecal DNA Isolation Kit
PowerFecal DNA Isolation Kit Catalog No. Quantity 12830-50 50 Preps Instruction Manual Inhibitor Removal Technology (IRT) is a registered trademark of MO BIO Laboratories, Inc. and is covered by the following
AFFINITY CHROMATOGRAPHY
92 AFFINITY CHROMATOGRAPHY Tosoh bioscience ANALYSIS 93 AFFINITY CHROMATOGRAPHY AFFINITY CHROMATOGRAPHY afc PRODUCTS TSKgel BORONATE-5PW TSKgel CHELATE-5PW TSKgel TRESYL-5PW TOSOH FACT The Tosoh logo symbolizes
HiTrap Chelating HP, 1 ml and 5 ml
GE Healthcare Instructions 71-7005-00 AX HiTrap affinity columns HiTrap Chelating HP, 1 ml and 5 ml HiTrap Chelating HP is a prepacked ready to use, column for preparative affinity chromatography. The
Application Guide... 2
Protocol for GenomePlex Whole Genome Amplification from Formalin-Fixed Parrafin-Embedded (FFPE) tissue Application Guide... 2 I. Description... 2 II. Product Components... 2 III. Materials to be Supplied
Application Note. Increasing the activity of monoclonal antibody isoforms by MCSGP. Summary
Application Note Increasing the activity of monoclonal antibody isoforms by MCSGP Category Matrix Method Keywords Countercurrent chromatography, FPLC Antibodies MCSGP FPLC, Biobetters, MCSGP, countercurrent
Protein transfer from SDS-PAGE to nitrocellulose membrane using the Trans-Blot SD cell (Western).
Western Blot SOP Protein transfer from SDS-PAGE to nitrocellulose membrane using the Trans-Blot SD cell (Western). Date: 8/16/05, 10/31/05, 2/6/06 Author: N.Oganesyan, R. Kim Edited by: R. Kim Summary:
Enzymes: Amylase Activity in Starch-degrading Soil Isolates
Enzymes: Amylase Activity in Starch-degrading Soil Isolates Introduction This week you will continue our theme of industrial microbiologist by characterizing the enzyme activity we selected for (starch
Agencourt RNAdvance Blood Kit for Free Circulating DNA and mirna/rna Isolation from 200-300μL of Plasma and Serum
SUPPLEMENTAL PROTOCOL WHITE PAPER Agencourt RNAdvance Blood Kit for Free Circulating DNA and mirna/rna Isolation from 200-300μL of Plasma and Serum Bee Na Lee, Ph.D., Beckman Coulter Life Sciences Process
PROTEINS (LOWRY) PROTOCOL
1 PROTEINS (LOWRY) PROTOCOL 1. INTRODUCTION The Lowry Assay: Protein by Folin Reaction (Lowry et al., 1951) has been the most widely used method to estimate the amount of proteins (already in solution
Antibody Purification and Labeling
5 Antibody Purification and Labeling 5.1 Antibody Purification 65 Magne Protein A Beads and Magne Protein G Beads 67 5.2 Antibody Labeling 69 phab Amine and Thiol Reactive Dyes 71 63 Discover Reliable
Protein Purification Handbook
Protein Purification Handbook Protein Purification Handbook 18-1132-29 Edition AC Handbooks from Amersham Biosciences Antibody Purification Handbook 18-1037-46 The Recombinant Protein Handbook Protein
UNO Q&S Continuous Bed Ion Exchange Column. Instruction Manual
UNO Q&S Continuous Bed Ion Exchange Column Instruction Manual Catalog Numbers 720-0001, 720-0003, 720-0005, 720-0021, 720-0023 and 720-0025 For Technical Service Call Your Local Bio-Rad Office or in the