Charge Controller CC611/CC612 Preliminary datasheet



Similar documents
LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Electronic overload relay EF19 and EF45

The solution for Europe: Type 2 charging socket with or without shutter

Electronic overload relay EF65, EF96 and EF146

Solutions for E-Mobility

PHOENIX CONTACT Features

Safety technique. Emergency stop module BO 5988 safemaster

emobility WAGO Leading the Charge

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Three-phase monitoring relay CM-PFE

Product and functional description

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Emergency lighting units EM powerled

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Analog signal converters CC-E I/I Current / current isolators

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Quick Connect. quick - simple - efficient.

Automation Unit TM 1703 ACP Flexible automation and telecontrol

3-phase, bidirectional energy meter

Short information Parameters are programmed via front-side membrane keypad

Electric Vehicle Charging Solutions

48 SERIES Relay interface modules 10 A

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

JUNE emobility. Charging Stations DOWNLOAD DATA SHEETS AND TENDER TEXTS. for charging stations emh1 here:

Modular I/O System Analog and Digital Interface Modules

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

How can a charging station for electric vehicles be set up simply and safely?

instabus KNX / EIB System System E F G H

Contact expansion modules

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

connecdim Gateway G1 Ethernet TCP/IP to DALI

RM4TG20 three-phase network control relay RM4-T - range V

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

CHARGING STATIONS FOR ELECTRIC VEHICLES QUICK CHARGER

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Type: DILM9 10(24VDC) Article No.:

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Drayton Digistat +2RF/+3RF

MasterINTERFACE 39 Series - Relay interface modules

DS1 Diode-based transient-free capacitor switch

Thermistor motor protection

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

Transmitter Actuator 230V wave UP 560. Operation

Type: DILM32 10(24V50HZ) Article No.:

Pluggable interface relays CR-P Pcb relays

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G

MasterINTERFACE 39 Series - Relay interface modules

PCS0100en Persy Control Services B.V. Netherlands

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

MAJORSINE Power Inverter

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

mecotron Safety relay ESTOP-2 For emergency stop monitoring

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Differential Charge Amplifier

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Catalog. Modular DIN rail components Installation contactors

Digital input modules

Operating instructions IV / 2007

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

HDTV Anywhere USER MANUAL / HDTV Anywhere ALL RIGHTS RESERVED MARMITEK

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

49 Series - Relay interface modules A. Features

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

HERZ-Thermal Actuators

Disturbance Recoder SPCR 8C27. Product Guide

Contact expander modules

PNOZsigma - Base units

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Proximity Switches RS (Reed Switch)

I STAR COMPUTER CO., LTD

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Redundancy Module QUINT-DIODE/40

Manual motor starter MS116

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

E-STOP relays, safety gate monitors

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Transcription:

Preliminary datasheet Preliminary datasheet CC61x_D00xxx_00_D_XXE_preliminary/04.2015

Product description The ender charge controller CC611 is the main component of a charging point and is designed for use in wall boxes, street light charging points and common charging stations. For electric vehicles, the charge controller controls the charging outlet socket. It enables a setup that is in accordance with current standards, such as IEC 62196, IEC 61851-1 and IEC 61851-22. CC611 Device features Standard OCPP Implementation Full OCPP Remote functionality inary OCPP implementation with bandwidth optimization and T network compatibility Smart Grid enabled using standard OCPP functionality Local and remote configuration Compatible with all electric vehicles on the market Optional display support utomatic resets The CC611 is characterized by its compact design and size (114.5 mm x 22.5 mm x 99 mm) that in turn enables intelligent, small and cost effective charging points. To enable the charge controller to communicate, a backend system together with a well-known and trusted communication protocol is required. Given that most backend providers strictly adhere to the OCPP communication protocol, the CC611 is OCPP 1.5 complaint and compatible with all electric vehicles on the market. Integration tests with the charge controller have already been performed with backend software providers, such as Vattenfall, osch, TT, DRIIVZ. The CC611 can be operated as an always on system that is always connected to a mobile network. The controller supports 2.5G Edge and 3G UMTS mobile networks. Connectivity for online operation is established using a SIM card. User interaction is facilitated using an RFID card reader and LEDs. Charging is initiated by either holding a valid RFID card close to the reader or remotely by the backend system via OCPP. In offline operation, the charge controller can optionally allow charging without authorization or it can authorize users based on RFID and a local white list of authorized RFID cards. Functional description s well as the CC611, a charging point also consists of a smart digital meter (EMH ehz), a power supply to operate the CC611, a relay contactor, which is directly connected to a vehicle socket and an RFID reader. When viewed from its correct mounting position on a cap rail, the CC611 has a total of 18 contacts. The control pilot and proximity contacts connect the CC611 to a type 2 outlet socket, enabling the charge controller to communicate with the vehicle and the cable plug. These contacts allow the CC611 to determine whether a cord has been plugged into the socket (proximity) and to inform the vehicle about the amount of power it can draw (refer to ISO/IEC 61851). To ensure that control pilot communication between the vehicle and the charge point is not misinterpreted, the 0 V contact of the charge controller power supply needs to be at same level as the protective earth (PE) used on the socket. Power flow toward the vehicle is controlled by the contactor (using a signal voltage of up to 30 V), which is itself controlled by the CC611 via a relay in the controller. The CC611 reads the digital ezh meter readings using an optical reader attached to the charge controller via an RJ11 plug. The optical reader interface is positioned on the back of the meter. The SIM card reader is positioned on the controller front panel, as is the US interface which is used to configure the charge controller. Optionally it can also be used to apply software updates. The CC611 facilitates simple user interaction using an RFID reader and a set of LEDs. These are located on a separate PC, which is attached using a standard RJ45 cable. Optionally an additional display can be attached to this PC for more detailed user interaction. In normal operation, the boot-up sequence begins after is applied to the controller. fter boot-up, the system establishes a connection to the backend communication system if configured. When a vehicle is connected to the charge point, the outlet socket automatically locks the inserted plug. Charging is initiated by holding an RFID card (registered with the backend system) close to the RFID card reader. fter ensuring the vehicle is connected and ready to charge, the contactor is then switched on to provide power flow. Once charging has completed and the plug on the vehicle side is disconnected by the user, the charge point socket automatically unlocks the plug on the charge point side. 2 CC61x_D00xxx_00_D_XXE_preliminary/04.2015

Wiring diagram Disconnecting switch V L1 L2 L3 EMH ehz Smart meter Residual current circuit breaker 2 4 6 1 3 5 C1 6 SIM C C4 RJ11 US 2 RFID 4 4 Meter L + 0 V 2 1 H 1 4 8 Contactor DC 1 D1 1 D D4 2 3G RJ45 US 1 D4 TE (Internal /external) 2 1 3 7 5 Front L1 L2 2 CP L3 PE M C C3 C1 P.1 P.2 3 PP + L1 2k2 1 L2 2 3 4 RFID Module 2 Optocoupler CP (anode) 3 4 PP Optocoupler (cathode) C2 D 0V C1 1 Optocoupler (cathode) 2k2 C 2k2 Optocoupler 0 V (cathode) Optocoupler (anode) Outlet socket P.3 Mennekes actuator (Type 196521) C2 L3 CC611/CC612 charge controller kwh IR module PE C3 C4 D1 D2 D3 D4 ctuator ** Mennekes (Type 196521) Sensor (P.2) P.3 (-) P.1 (+) Mennekes (Type 30537-) P.1 (2-ring from actuator) P.3 (+) Kuster ZS (S 075-005-001) Yellow rown Red Green FCT Group (FXL12S1-4409) White rown Green Yellow P.2 (-) 1 (Contactor) ** Different actuators are supported. CC61x_D00xxx_00_D_XXE_preliminary/04.2015 3

Technical data Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Rated voltage Overvoltage category/pollution degree Rated impulse withstand voltage (CC611) pplication range Environment/EMC III/3 0.5 kv 4000 m above sea level Supply voltage ominal supply voltage US Operating range of the supply voltage Power consumption without modem Power consumption with modem/short-term peak DC DC 0.8 1.2 x US < 5 V < 11 V Measuring range residual current (CC612 only) Connection Rated frequency Measuring range 0 2000 Hz ± 300 m Response values (Only for CC612) Residual current IΔn1 6 m Response tolerance IΔn1 0-50 % Residual current IΔn2 30 m Response tolerance IΔn2 for: f 1 khz 0-20 % f 1 khz -20 +100 % Restart sequence value: DC 6m < 3 m C/DC 30 m (rms) for f 1 khz < 12 m C/DC 30 m (rms) for f 1 khz < 22 m Operating time tae1 für 1 x IΔn1 < 600 ms Operating time tae2 (at DC or > 15 Hz) for: 1 x IΔn2 < 180 ms 2 x IΔn2 < 70 ms 5 x IΔn2 < 20 ms Inputs/outputs and operation LED 1 green LED 2 green LED 3G green US 1 Extension interface (Ethernet, WiFi, ) US 2 Configuration interface SIM card micro SIM Control pilot, proximity and optocoupler input (terminal block ) input/output Meter (RJ11 plug) external RFID interface (RJ45 cable) external Power supply and optocoupler input (terminal block ) input Plug lock (terminal block C) input/output Relay K1/K2 (terminal block D) output Switching elements Relay K1 Relay K2 Switching elements Operating principle Electrical service life Contact data acc. to IEC 60947-5-1: Rated operational voltage Rated operational current Minimum contact rating EMC IEC 61326 Operating temperature -25 +75 C Climatic class acc. to IEC 60721: Stationary use (IEC 60721-3-3) 3K5 Transport (IEC 60721-3-2) 2K3 Long-term storage (IEC 60271-3-1) 1K4 Classification of mechanical conditions acc. to IEC 60271: Stationary use (IEC 60721-3-3) 3M4 (except condensation and formation of ice) Transport (IEC 60721-3-2) 2M3 Long-term storage (IEC 60271-3-1) 1M3 charging contactor configurable 2 x 1 /O contacts /C operation 100,000 switching cycles 30 V 1 1 m at C/DC 10 V 4 CC61x_D00xxx_00_D_XXE_preliminary/04.2015 Connection type Connection properties: rigid/flexible flexible without ferrule flexible with ferrule Stripping length Opening force Test opening, diameter RJ 45 RJ 11 push- terminal 0.2 2.5mm² (WG 24 12) 0.25 2.5mm² (WG 24 12) 0.25 2.5mm² (WG 24 12) 7 mm 0.5-0.6 m (4-5 Ib-in) 2.1 mm RFID reader meter Other Operating mode Degree of protection Degree of protection terminals DI rail mounting continuous operation IP 30 IP 20 IEC 60715

Ordering information Supply voltage US DC Dimension diagram Dimensions in mm 6 m sensor Type rt. o. CC611-1P3 CC612-1P3 9406 0000 9406 0001 99 22.5 7 Type designation rt. o. RJ45 cable for RFID PC (lenth 500 mm) RFID PC 9406 0100 9406 0110 114.5 ccessories 50 99.5 RJ 45 RFID module CC61x_D00xxx_00_D_XXE_preliminary/04.2015 5

EDER Group CC61x_D00xxx_00_D_XXE_preliminary / 04.2015 / pdf / ender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the version that was valid at the time of printing. ender GmbH & Co. KG P.O. ox 1161 35301 Gruenberg Germany Londorfer Strasse 65 35305 Gruenberg Germany Tel.: +49 6401 807-0 Fax: +49 6401 807-259 E-Mail: info@bender.de www.bender.de