Optical fiber intrusion detection fence sensor

Similar documents
Utilizing Furukawa Optical Fiber Technology. Optical Fiber Sensing System

INTREPID Perimeter Intrusion Detection System

Perimeter Security System

Advanced Fencing and Security Technologies Ltd

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Architectural and Engineering Specification for a Perimeter Intrusion Detection and Pipeline Third-Party Interference (TPI) Detection System

Solution 1: Algorithm Positioning

Fiber Optic Distributed Temperature Sensor (B-DTS)

FUJI DIGITAL SOUND DETECTOR FSB-8D INSTRUCTION MANUAL

Architectural and Engineering Specification for a Perimeter Intrusion Detection System. FiberPatrol-ZR

LB Sky Global. 92 Lobachevskogo St, Bld 92, Office 5, Moscow, Russia Tel/Fax 7(495) , Site:

INTREPID Buried Cable Perimeter Intrusion Detection System

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

DLO1191 Linear smoke detector

Sensor Network for HACCP Food Safety Management

How to Solve the Most Persistent Problem in Perimeter Security Systems

Indoor / Outdoor Antenna

Evaluation of the "StrikeGuard" Lightning Alarm Sensor Using Lightning Location System (LLS) Lightning Data

Mitel DECT Base Stations

FIBER SECURITY. Optical Fiber Perimeter Intrusion Detection System

FAAST. Fire Alarm Aspiration Sensing Technology

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

How To Read A Pipe From A Sensor

The Premier Fence Mounted Perimeter Intruder Detection System

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Temperature & Humidity SMS Alert Controller

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

Description. Dimensions. Features. precision works better

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature

Continuous, remote monitoring and logging of electromagnetic fields

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

How To Power A Schen

Terminal and Dimension

Introducing TransitVUE Perimeter IDS, the most advanced perimeter intrusion detection system available today! Protecting Perimeters Around the World

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Monitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

New Direct Core Monitoring Fusion Splicer TYPE-71C+

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Power supply unit Model: PAC-SC50KUA

Passive Infrared Motion Detector 5420/90. Installation Instructions

LeakFilm. Protecting your high-tech assets with innovative, user-friendly technology for liquid leak detection

1. Introduction. 2. Components. 3. Optical Specifications. 4. Electric Specifications. 5. Dimension. 6. Operating Environment. 7.

GSM Voice Auto Dialer & SMS Sender JC-999

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Analogue addressable devices

Nardalert S3 Non-Ionizing Radiation Monitor

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Low Frequency Velocity Sensor

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

AX-100TFR/AX-200 TFR INSTALLATION INSTRUCTIONS INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR.

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

On-line Machine Condition Monitoring [The CMS System]

Auxiliary equipment for communication with the EuroProt protective devices

Fiber Optic High Density ACC Sensor System Faser Optisches Beschleunigungs-Messsystem

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

iva Cable & Antenna Analyzer

User Guide. MC100CM MC110CS Fast Ethernet Media Converter. MC111CS MC112CS WDM Fast Ethernet Media Converter

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

Fiber Optics. Integrated Photo Detector Receiver for Plastic Fiber Plastic Connector Housing SFH551/1-1 SFH551/1-1V

- 1 - Eddy Current. Eddy current distance and displacement transducer

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

ADM1TE 5/30A DIN rail single phase two wire energy meter

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

FC6 FOOT CONTROLLER OWNER S MANUAL

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Frequency selective monitoring and logging of environmental electromagnetic fields

RC001-4/RC002-4 (REV.B) 4-slot rack mounted chassis User manual

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

ACS-30-EU-EMDR-10-MOD

10/100/1000 Base-T to Gigabit Fiber Media Converter

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

75 Ω Transmission System

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

DCP Fan Controller. Version 01/2009. The engineer s choice

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

T0118 T2118 T3118. Instruction Manual

Application. Benefits. Contact us. Solution for Indoor TETRA coverage. TETRA/TETRAPOL Repeater RF/OF High Power. To ensure TETRA coverage everywhere

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

Transcription:

Optical fiber intrusion detection fence sensor

This is an Intrusion detection fence sensor More accurate detection More reliable detection Simpler installation Wider detection coverage 6 7 8 Better immunity from thunder More flexible layouts Easier deployment Operating principles and functions 1 More accurate detection (High repeatability of detection, fewer false alarms) When equivalent vibrations are applied to the high-sensitivity PMF, the waveforms obtained are nearly identical, which helps set accurate threshold values. Alarm thresholds can be precisely programmed. Example Fence sensor unit (HIDS-2) Outdoor Protective box Optical sensor cable 2

using optical fiber. Optical fiber intrusion detection fence sensor Intruder detection for important facilities, plants and laboratories Spectrum evaluation enables the reduction of false alarms by removing spectral components of environmental factors such as winds. Alarms the wind Intruder Strong wind Climbing on the fence at strong wind Frequency Frequency High Low Spectrum intensity Time Time Spectrum intensity distributions of fence vibrations 3

2 More reliable detection (Less environmental influence) dust because there is no use of free space optics. snowfall and fog 3 Simpler installation (Sets up easily even for complex perimeters) No need to set up mechanical devices such as tension control structure and pulleys No need to divide monitoring sections along the corner of fences excretion of birds and suchlike dry leaves snowfall fog Detect vibration with the upper and lower 1.5 meters each 4 Wider detection coverage waste paper (Makes it possible to set up two-dimensional monitoring regions) Fence vibrations detected up to approx. 1.5m above and below sensor (for chain-link fences). 4

Optical fiber intrusion detection fence sensor 5 Better immunity from thunder (Optical fiber cable is unaffected by Electromagnetic interference) Optical sensor cable is unaffected by inductive lightning Optical sensor cable doesn t generate Electromagnetic noise. OK inductive lightning Install an optical sensor cable only Relay/ Additional fences 6 More flexible layouts (Supports changes and expansions to layout) Make it possible to increase monitoring section using expansion sensor cable and Relay/Terminal box. 5

7 Easier deployment Easy installation using cable ties. (No need to fix cable to fence closely) Installation Fixing method - Sensor unit : Put in an outdoor Protective box - : Fix in a fence post using stainless bands. - Optical sensor cable : Fix in fences without a slack at intervals of 25 cm or less. Detail drawing of optical sensor cable installation Intervals 25 cm or less Optical sensor cable Outdoor Protective box (IP55 is recommended) Max. 300m ( 100 m is recommended) A short cable length is recommended when the magnitude of fence vibration between posts is uneven Fence post Max. 300m Power source Signal To a secure control room Fence Cable tie 8 Operating principles and functions The intrusion detection fence sensor uses the principle of a Sagnac interferometer. When the vibration of the sensor cable stretches and contracts the PMF, light propagating in clockwise (CW) and counterclockwise (CCW) directions in the closed interferometer arrive at a vibrating point at different times. This produces a phase difference that can be detected. A microcomputer is used for the signal processing, and it can process a fast arithmetic processing of the vibration intensity. It can output the data with a relay contact and LAN. Light source Optical fiber coupler Polarizer Optical sensor cable CW Photo detector Phase modulator Signal processing circuit CCW RS232C LAN RELAY COM Ethernet Warning Caution Failure Tamper open Relay contact output Ethernet is registered trademark of Fuji Xerox Co., Ltd. Configuration of fence sensor 6

Optical fiber intrusion detection fence sensor Specifications 1.Fence sensor unit 1Type HIDS = 1 : Single channel use, = 2 : Two channels use (Hitachi metals Intrusion Detection Sensor) 2Detection condition Climbing on the fence 3Output signal Caution, Warning, Trouble, and Tampered 4Changeable settings Evaluation value, Signal amplification 5Measurement distance Max. 300m (100 m is recommended) 6Operating temperature -30 to +70 [degc] 7Operating humidity range 0 to +95 [%RH] (Non condensation) 8Supply voltage DC +12 V or DC +24 V 9External dimensions 140 190 70 mm 10Weight Below 2 kg (Excluding optical sensor cable) 2. Optical sensor cable 1Type 2Cable diameter 3Optical fiber 4Cable sheath 5Allowable bending radius 6Allowable pulling tension 7Waterproof, Dustproof 8Reinforcement fiber 9Tension member 10Cable weight 11Bobbin size Optical sensor cable with an end box C PMF M = Cable length Optical sensor cable with both ended SC connector W PMF M : 50m,100m,200m Maximum distance of connected cable is 300m. Maximum connecting point is one point. φ4mm Polarization maintaining fiber Polyethylene (Gray) R130mm 150N IP55 ( only) Aramid fibers FRP φ0.4mm 1 11g/m φ430 340mm 3. Relay/ 1Type CB-10 (Connector Box) 2External dimensions 150 45 230 mm 3Ingress Protection code 5 JIS C 0920 4Weight About 1.5kg 7

Hitachi Metals, Ltd. http://www.hitachi-metals.co.jp/e/ Cable Materials Company Shinagawa Season Terrace, 2-70, Konan 1-chome, Minato-ku, Tokyo 108-8224, Japan Tel : +81-3-6774-3730 Hitachi Cable America Inc. Head Office 2 Manhattanville Road, Suite 301, Purchase, NY 10577, U.S.A. Tel : +1-914-694-9200 Specifications subject to change without notice. CAT.NO.KSE622A All rights reserved Printed in Japan 16-4(D)