Application Note Optical Fiber Cable

Similar documents
AERIAL FIBER OPTIC CABLE PLACEMENT

Underground Cable Installation

Fiber Optic Cable Installation

Cable Preparation and Pulling Procedure Best Practices for Fiber Optic Indoor Tight-Buffered Cable

Procedure for Cutting and Respooling Fiber Optic Cable

Fiber Optic Cable Installation

Cable Installation Notes

TubeTrace, ThermoTube

Optical Cable Pre-Construction Survey. Keywords Stationary Reel Method, empty innerducts, sub-ducts, microducts, Intermediate-feed manholes

Intrabuilding Installation of Corning Cable Systems Fiber Optic Cable

SECTION 680 FIBER OPTIC CABLE DESCRIPTION

Ideal Cable. Linear Spring - 1. Cables, Springs and Pulleys

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007

Intelligent Cable Management Systems

DOUBLE DRUM TRACTION WINCH SYSTEMS FOR OCEANOGRAPHIC RESEARCH 1.0 TRACTION WINCH SYSTEM ADVANTAGES 11-2

What is a Fabric innerduct and why even use one? Archie Booker MaxCell Southwest Territory Manager

ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

BELFLOW SERIESS FIBER DISTRIBUTION FIBER DISTRIBUTION BELFLOW IS A BOF (BLOWING OF FIBER) SYSTEM DEVELOPED FROM BELCONN.

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

Terminating 25-Pair Cable and 4-Pair Cross Connects

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

CABLE TERMINATION BEST PRACTICES A guide to improved cable performance through proper termination and installation.

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

FIBER OPTIC CABLE PLANT DOCUMENTATION

SECTION SIGNAL WIRE AND CABLE

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES OUTCOME 2 ENGINEERING COMPONENTS TUTORIAL 1 STRUCTURAL MEMBERS

SnoTrace KSR Surface Snow and Ice Melting INSTALLATION PROCEDURES

Buried Cable Installation

Installation and Application Guide. for 600V Conductors

Plastics for Longer Life. The NEW Multi-Axis Energy Chain for Robots. Triflex

Mechanical Reasoning Review

Network Standard Advice No. 1420C 9/6/2011

Specifying an IT Cabling System

MaxCell Technical Manual Design Parameters

4. Handling and Installation

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES AND APPLICATIONS NQF LEVEL 3 OUTCOME 1 - LOADING SYSTEMS TUTORIAL 3 LOADED COMPONENTS

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

KNOW YOUR OPTIONS: 230 KV POWER CABLES

Fiber Optic Cable Installation and Handling Instructions

Design of Ultra-High-Density 2000-Optical Fiber Cable with Pliable 8-fiber Ribbons for Underground Deployment

PRODUCTS PRODUCTS ABOUT US.

Cable Preparation Best Practices for Fiber Optic Indoor/Outdoor Stranded Loose Tube Cable

AIR COOLER. fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES

CATIA Electrical Harness Design TABLE OF CONTENTS

288 Fiber Ultra-High Fiber Density Micro-Duct Cable with Extreme Operating Performance

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

Section kv Power Cables

I BEAM TRACK INSTALLATION

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

For business. Wiring your business for broadband. What happens when copper is required?

Total Service Solutions

home site map help ECMS Project: Standard / Federal Oversight Advertised

FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER

Mechanical Principles

COMPETENCY ANALYSIS PROFILE. Rodworker 452A. (All unshaded skill sets must be demonstrated/ completed) Lift equipment and materials

4 in 1 Strength Station

TELUS Residential Service Conduit Requirements for Stand Alone Homes and Duplexes in Fibre Only Communities

Sheet Metal Shearing & Bending

Contents. 1. Foreword Common accidents in lifting operations Legislative requirements and code of practice of lifting operations 2

Key Design Criteria for High Flex Cable Constructions By Mike Levesque, Dale S. Long, and Ron Crouch of C&M Corporation

Cable management for rack-mounted systems

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

Effect of Temperature on Wireline Cables Technical Bulletin Ten

Reasons for reissue of this instruction sheet are provided in Section 5, REVISION SUMMARY.

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

144Fibre SM (G.652) Loose Tube Micro Lite Duct Optical Fibre Cable PRODUCT INFORMATION

Guidelines for Installation of Fiber Optic Cables

SECTION FIBER OPTIC CABLE AND ACCESSORIES

FTTx Optical Fiber Cable for Easy Mid-Span Access ( EZremove )

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

FOK MACHINES FIBRE OPTIC CABLE BLOWING MACHINE USER S BOOK. fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES

STANDARD PRACTICE INSTRUCTION

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

MESSENGERS FOR AERIAL CABLE

SECTION COMMUNICATIONS OPTICAL FIBER OSP CABLING

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Specification Standards Communications Underground Ducts, Raceways and Structures

Attenuation: Bending Loss

Discontinued. Volition. Fiber Optic Cable. 3Innovation

Installation of Corning Cable Systems Self-supporting (Figure-8) Aerial Cable

HYDROFOK MACHINES. HYDRAULIC CABLE & TUBE BLOWING MACHINE with HYDRAULIC POWER UNIT) fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES

1 Campus Cabling Systems Introduction

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

EVALUAT ING ACADEMIC READINESS FOR APPRENTICESHIP TRAINING Revised for ACCESS TO APPRENTICESHIP

Camber, The unkind Curve

SECTION O FIBER OPTICS

Utilities and existing services

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

Pipe Bursting. Case Study at Zeeland, MI Collections Seminar September 6, Presentation Agenda. What is Pipe Bursting? What is Pipe Bursting?

Sewing Methods Chicago Style Stitch

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Reasons for reissue are in Section 6, REVISION SUMMARY.

B.TECH. (AEROSPACE ENGINEERING) PROGRAMME (BTAE) Term-End Examination December, 2011 BAS-010 : MACHINE DESIGN

SPECIALTY FIBER OPTIC CABLE. Downhole Sensing Subsea

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

Transcription:

Underground Installation of Optical Fiber Cable by Pulling Authors Prasanna Pardeshi and Sudipta Bhaumik Issued July 2015 Abstract This application note discusses underground fiber optic cable installation by pulling technique, the factors effecting pulling performance & best practices. Keywords Fiber optic cable, Underground installation, Cable pulling

Introduction Optical fiber cables for telecommunication application have been installed in pipes/ducts for many years. The installation process is influenced by local conditions, local climate, customer s existing procedures, and customer requirements. There are two basic methods of cable installation in a preinstalled duct Pulling method and Blowing method. The cable installation method is selected based on site conditions and availability of machinery & resources. Table 1 shows a comparison between the two installation methods. Table 1 Comparison between Pulling and Blowing methods Pulling Method Pulling rope pre-installed Equipment and manpower at two sides High sidewall forces on cables and ducts may lead to cable damage Mainly manual pulling is practiced. Machine pulling needs one hydraulic power pack Mainly used for straight duct route Suitable for short distance (few 100 meters) installation Blowing Method No pulling rope to install Equipment and manpower at one side Forces on cable and duct can be monitored and controlled and minimal chance of cable damage Large compressor and/or hydraulic power pack at one side Preferred for duct route with multiple bends and undulations Preferred for long distance (over 2 km) installation Pulling procedure is necessary and unavoidable in certain areas such as the small areas, small patches where blowing set up is not able to be accommodated. In this application note, cable installation by pulling method and its best practices are explained. Pulling Method Cable installation into a pre-installed underground ducts/pipes by manual pulling or by puller machine is called as Pulling Method. In this method, cable is pulled through duct/pipes with the help of pre-installed rope inside the duct/pipes. Optical fiber Cable pulling in underground horizontal duct routes requires some special considerations. These considerations are familiar to the installers who are specialize in optical fiber cabling installation, but may be unknown to the contractor who has dealt primarily with copper cabling. Failing to follow such a procedure can result in fiber/cable damages or high optical power losses after installation. Optical fiber cable pulling is generally preferred in access networks where underground ducts/pipes are not continuous for more than 200 to 300 meters and cable needs to be stored in coil form at each manhole/handhole available at every 200 to 300 meters. If cables are pulled into conduit or inner duct, the Duct Fill Ratio to be maintained below 65%. The ratio between cross sectional area of the cable and inner space of the duct is known as Duct Fill Ratio (DFR) or Fill Ratio.

DFR = d 2 x100 D 2 Where, d= cable diameter D= duct inner diameter Cable Pulling Guidelines and Best Practices Duct Route Survey Conduct the duct route survey and inspect the route for manhole, coiling, splicing locations. Ensure there are no sharp bends or slops that exceed the minimum bend radius of the cable (refer cable supplier specification sheet). Identify and attain the potential problems during route survey. Identify the cable reel location/pulling location. Ensure the duct continuity is thorough and clear for the pulling length patch. Pulling Rope Ensure cable pulling rope is available in the duct. If pulling rope is not available inside the ducts then first install the pulling rope with the help of rodder as shown in Figure1. Push the rodder rod through one end of the duct/pipe and as the rodder rod reaches to other end of the duct/pipe, tie the pulling rope with the rodder rod at other end and reel back the rodder rod. Cable Pulling Grip Figure 1 Pulling rope installation by rodder Cable pulling grip shall be fixed at the head of the cable as shown in below figure 2. The function of this grip is to provide effective grip over cable sheath which is very useful during cable pulling. A wrap of plastic tape shall be wrapped around the grip which has been pulled tight over the cable. Figure 2 Wire mesh cable pulling grip

Breakaway Swivel It is strongly recommended to use breakaway swivel during manual pulling installation where pulling tension is not controlled. During manual pulling, applied pulling tension higher than the cable tensile rating can damage the cable and negatively impact its lifetime. Breakaway swivels are available with different tensile rating and can be placed in between cable and pulling rope. The main function of breakaway swivel is to break the swivel device if excess tension applied during cable pulling. For example, if cable rated tensile is 2700N and breakaway swivel having 2500N tensile strength is fixed, when the cable pulling tension goes above 2500N, the swivel will break so that excess pulling tension will not have any impact on cable. Cable reel pay-off This feature is very important in optical fiber cable installation set-up to ensure cable is smoothly reel off. It is always recommended to use cable reel pay off during cable installation. The cable reel should be kept in level to avoid cable rubbing against the reel flanges. The cable reel orientation should be such that the natural payoff direction is towards the pulling direction. To eliminate possible cable contact with the ground, cable payout should be from the top of the reel. Figure 4 shows a cable reel in a cable reel pay-off and figure 5 shows the do s and don ts of cable unwinding. Cable Handling Figure 3 Swivel Figure 4 Cable reel pay-off Figure 5 All optical fiber cables are sensitive to damage during shipping, handling, and installation. Some of the important parameters that need special attention during cable pulling installation are: Cable bending radius: Optical fiber cables are designed with a minimum bending radius. The cable should never be bent below its minimum bending radius. Doing so can result in bending losses and/or fiber breaks in the cable. Generally the minimum bending radius of a fiber cable under load is 20 D, where D is the diameter of cable. Figure 6

Cable Pulling Tension: Optical fiber cables are designed with a maximum tensile strength. The cable should never be pulled beyond its maximum tensile strength. Exceeding the cable s pulling tension provided by Sterlite in the Cable Data Sheet / Specification, can alter cable and fiber performance and shorten its in-service lifetime. Cable Twist: Cable twist can develop stress on the fibers and therefore need to be avoided. Tension on the cable and pulling ropes can cause cable twisting. Use a swivel pulling eye to connect the pulling rope to the cable prevents pulling tension causing twisting forces on the cable as shown in figure 3. Unroll the cable off the reel loaded on pay-off or reel jack instead of manually taking out as shown in figure 4. When reel-off the cable for pulling, stored in figure-8 shape on the ground to prevent twisting. The figure 8 puts a half twist in one side of 8 and takes it out on the other side to prevent generation of twists in cable. Cable Lubricants Figure 7 Cable stored in fig-8 shape Use of cable lubricants to reduce co-efficient of friction between cable outer surface and duct inner surface is recommended to pull cable in a duct route having multiple bends, elevation and undulations. The lubricant material should not react with cable outer sheath (don t use soap water, kerosene, diesel). Apply right quantity of lubricant as suggested by the supplier. For additional information refer Sterlite application note titled Underground Installation of Optic Fiber Cable Placing (issue- November 2014).