servo-controlled 3-WaY vacuum solenoid valves WiTH



Similar documents
MEMBRANE VACUUM MINI PUMPS

SOLENOID VALVES AND PNEUMATIC VALVES

System 8. ü ( System 8

Solenoid valves 2/2-way direct-operated Type EV210A

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Assisted lift operated 2/2-way solenoid valves Type EV250B

3/2-way Mini Solenoid Valve

4/2-Way Pneumatic Solenoid Valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Electro-pneumatic control valves

type V46, solenoid or pneumatic operated

4 Posiflow Proportional Solenoid Valves

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

2.12. page Products for Explosion hazardous Environment

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

3/2- and 2/2-way cartridge valve type BVE

Cable Plug acc. to DIN EN , Form A

VDL 53 - Vacuum drying oven for flammable solvents

G1/4 Q8. Standard with biased position

3/2-way pneumatic cartridge solenoid valve

Vacuum Gate Valve DN 100 and DN 150

High Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override

Pressure transmitter For general industrial applications Model A-10

Sporlan V-Series Ruby Seat Solenoid Valves

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Thermometer in stainless steel with capillary and switch contacts

Solenoid valves Type EVU

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

STC 3S A Series Solenoid Valves

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Unit 24: Applications of Pneumatics and Hydraulics

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Type 3353 Angle Seat Valve

Single sub-base valve

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

Directional seated valves type VP 1

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Proportional pressure regulators VPPE

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Electronic Pressure Switch EDS 300

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

ORLANDO srl. M P R OPTIMA Radial pressure gauges for swimming-pools 0-2,5 Bar

SOLENOID VALVE FOR REFRIGERATING SYSTEMS

VSO MAX HP High Flow Proportional Valve

Coils - Connectors. Coils Connectors. Summary. RE / /10 Replaces: RE / Description

Actuators and Sensors. Products

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

SOLENOID VALVES 3-4 WAY

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

RI27-J CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

Control blocks for two-hand start ZSB

Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve

Threaded Resistance Thermometers Model TR10-D, Miniature Design

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Automatic Bypass Control AVDO

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

zamak nitrile rubber self-extinguishing technopolymer aluminum

Instruction Manual Differential Pressure Transmitter

MFP14, MFP14S and MFP14SS Automatic Pumps

Linear Luminaire with LED Series EXLUX 6402/2

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Series description: Wilo-Star-Z

How To Build A Low Voltage Capacitor Lvcp

C 50 μm filtered air, with or without lubrication spool 10 bar G/18 G1/4 6,5 8,5 890

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

10 mm Solenoid Valves. 0,6 W Power Consumption. 10,5 mm wide. 230 l/min air-flow. Service friendly design. High quality solenoid system

Flow divider (flow distributor), type TQ

Bimetal thermometer Model 52, industrial series

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

RI27 CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Hydraulic Flow Control Valves

Fast closing valve Series 75

Refrigeration Compressed Air Dryer Buran Ultrapulse

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Reaction Torque Sensor

Transcription:

servo-controlled 3-WaY vacuum solenoid s WiTH low absorption electric coil The 3-way vacuum solenoid s in this series feature two positions with pneumatically pilot-operated conical shutters. They can normally be used either open or closed. They are composed of an anodised aluminium body where the connections are located, two shutters in vulkollan assembled onto a stainless steel stem, a special compound membrane for the servo-control and a spring for the shutter return. A activated by a built-in electric coil, manages the compressed air supply. The particular execution of these s allows reducing frictions and internal dynamic stresses to the minimum, which results in a high response speed and a guarantee of long lasting operation. The electric coil of the is fully plasticised plasticised with synthetic resin, tight execution, insulation class F (up to 155 C) compliant with VDE standards, with 3 mm 2-terminal electrical connections in compliance with EN 175301-803 (ex DIN 43650)-C. Protection degree IP 54; IP 65 for inserted. Available for voltages of 12-24V/50-60Hz and 12-24V/CC. Allowed tolerance on the voltage nominal value: ±10%. Maximum electric power: 2 W The can be rotated by 180 on the coil and can be supplied, upon request, with Led lights, anti-interference circuit and/or with protection devices against overvoltage and polarity reversal. A push-button device, built-in the, allows ly opening and closing the solenoid. 3-way vacuum solenoid s are usually used for intercepting the vacuum in vacuum cup feeders and paletisers, robots, bag openers and in all those cases which require a exchange between the vacuum pump suction and the air inlet in the circuit, for a restoration of the atmospheric pressure. Technical features Working pressure: from 0.5 to 3000 mbar abs. Servo-control pressure: see table Temperature of the sucked fluid: from -5 to +60 C X = Compressed X air = supply Compressed air X = supply Compressed air supply X = Compressed air supply X = P Compressed = Pump air supply P = A Pump = Service A = R Service = Passage X = Compressed X air = supply Compressed air X = supply Compressed air supply X = P Compressed = Passage air supply P = A Passage = Service A = R Service = Pump Ø cum/h min max exc. deexc. orifice mm 2 bar (g) kg 07 01 13 g1/4 6 1000 0.5 16 27 8.5 56.8 4 7 0.44 07 02 13 g3/8 10 1000 0.5 16 27 11.5 103.8 4 7 0.43 Note: Please specify the electric coil voltage in the order (E.g.: 07 01 13 V24-CC) The is not integral part of the solenoid and, therefore, must be ordered separately (See solenoid accessories). 4.36 Conversion ratio: inch = mm g ; pounds = = Kg GAS-NPT thread adapters available at page 1.117

servo-controlled 3-WaY vacuum solenoid s WiTH low absorption electric coil 4 solenoid pilot X = Compressed air supply X = Compressed air supply Ø cum/h min max exc. deexc. orifice mm 2 *bar (g) kg 07 03 13 g1/2 20 1000 0.5 16 40 15.0 176 6 7 0.52 * Add the letters LP to the article for servo-control pressure 4 6 bar (g). Note: Please specify the electric coil voltage in the order (E.g.: 07 03 13 V24-CC) The is not integral part of the solenoid and, therefore, must be ordered separately (See solenoid accessories). Conversion ratio: inch = mm ; pounds = g = Kg GAS-NPT thread adapters available at page 1.117 4.37

servo-controlled 3-WaY vacuum solenoid s WiTH low absorption electric coil X = Compressed air supply X = Compressed air supply Ø cum/h min max exc. deexc. orifice mm 2 *bar (g) kg 07 04 13 g3/4 40 1000 0.5 16 40 20 314 6 7 1.00 07 05 13 g1 90 1000 0.5 18 42 25 490 6 7 0.94 * Add the letters LP to the article for servo-control pressure 4 6 bar (g). Note: Please specify the electric coil voltage in the order (E.g.: 07 04 13 V24-CC) The is not integral part of the solenoid and, therefore, must be ordered separately (See solenoid accessories). 4.38 Conversion ratio: inch = mm g ; pounds = = Kg GAS-NPT thread adapters available at page 1.117

servo-controlled 3-WaY vacuum solenoid s WiTH low absorption electric coil 4 interface interface interface interface X = Compressed X = air Compressed supply X = air Compressed supply air supply X = Compressed X = air Compressed supply X = air Compressed supply air supply Ø cum/h min max exc. deexc. orifice mm 2 *bar (g) kg 07 06 13 g1 1/2 180 1000 0.5 60 38 40 1256 6 7 4.50 * Add the letters LP to the article for servo-control pressure 4 6 bar (g). Note: Please specify the electric coil voltage in the order (E.g.: 07 06 13 V24-CC) The is not integral part of the solenoid and, therefore, must be ordered separately (See solenoid accessories). Conversion ratio: inch = mm ; pounds = g = Kg GAS-NPT thread adapters available at page 1.117 4.39

servo-controlled 3-WaY vacuum solenoid s WiTH BisTaBle impulse solenoid PiloT and WiTH low absorption electric coil These solenoid s have the same functions and structure as the previously described ones. Their distinctive feature is a bistable impulse solenoid activated by a built-in low absorption electric coil which, at a simple electric impulse, exchanges the shutter position even in absence of electricity, until it receives a new impulse of opposite polarity. For this reason, they can only be supplied with DC electric coils. They are particularly recommended in all those cases that require a safe connection to the vacuum source, even in absence of electricity. The electric coil of the is fully plasticised plasticised with synthetic resin, tight execution, insulation class F (up to 155 C) compliant with VDE standards, with 3 mm 2-terminal electrical connections in compliance with EN 175301-803 (ex DIN 43650)-C. Protection degree IP 54; IP 65 for inserted. Available for voltages of 12-24V/CC. Allowed tolerance on the voltage nominal value: ±10%. Maximum electric power: 1 W The can be rotated by 180 on the coil and can be supplied, upon request, with Led lights, anti-interference circuit and/or with protection devices against overvoltage and polarity reversal. The push-button device for their cannot be installed on these solenoid s. Technical features Working pressure: from 0.5 to 3000 mbar abs. Servo-control pressure: see table Temperature of the sucked fluid: from -5 to +60 C solenoid pilot X = Compressed air supply X = Compressed air supply Ø cum/h min max exc. deexc. orifice mm 2 bar (g) kg 07 01 53 g1/4 6 1000 0.5 16 27 8.5 56.8 4 7 0.44 07 02 53 g3/8 10 1000 0.5 16 27 11.5 103.8 4 7 0.43 Note: Please specify the electric coil voltage in the order (E.g.: 07 01 53 V24-CC) The is not integral part of the solenoid and, therefore, must be ordered separately (See solenoid accessories). 4.40 Conversion ratio: inch = mm g ; pounds = = Kg GAS-NPT thread adapters available at page 1.117

servo-controlled 3-WaY vacuum solenoid s WiTH BisTaBle impulse solenoid PiloT and WiTH low absorption electric coil 4 X = Compressed air supply X = Compressed air supply Ø cum/h min max exc. deexc. orifice mm 2 *bar (g) kg 07 03 53 g1/2 20 1000 0.5 16 40 15.0 176 6 8 0.52 * Add the letters LP to the article for servo-control pressure 4 6 bar (g). Note: Please specify the electric coil voltage in the order (E.g.: 07 03 53 V24-CC) The is not integral part of the solenoid and, therefore, must be ordered separately (See solenoid accessories). Conversion ratio: inch = mm ; pounds = g = Kg GAS-NPT thread adapters available at page 1.117 4.41

servo-controlled 3-WaY vacuum solenoid s WiTH BisTaBle impulse solenoid PiloT and WiTH low absorption electric coil solenoid pilot solenoid pilot solenoid pilot solenoid pilot X = Compressed air X supply = Compressed air supply X = Compressed air X supply = Compressed air supply Ø cum/h min max exc. deexc. orifice mm 2 *bar (g) kg 07 04 53 g3/4 40 1000 0.5 16 40 20 314 6 8 1.00 07 05 53 g1 90 1000 0.5 18 42 25 490 6 8 0.94 * Add the letters LP to the article for servo-control pressure 4 6 bar (g). Note: Please specify the electric coil voltage in the order (E.g.: 07 04 53 V24-CC) The is not integral part of the solenoid and, therefore, must be ordered separately (See solenoid accessories). 4.42 Conversion ratio: inch = mm g ; pounds = = Kg GAS-NPT thread adapters available at page 1.117

SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES WITH BISTABLE IMPULSE SOLENOID PILOT VALVE AND WITH LOW ABSORPTION ELECTRIC COIL 4 solenoid pilot interface interface interface interface X = Compressed X air = Compressed supply air supply X = Compressed X air = Compressed supply air supply Ø cum/h min max exc. deexc. orifice mm 2 *bar (g) Kg 07 06 53 G1 1/2 320 1000 0.5 60 38 40 1256 6 8 4.5 * Add the letters LP to the article for servo-control pressure 4 6 bar (g). Note: Please specify the electric coil voltage in the order (E.g.: 07 06 53 V24-CC) The is not integral part of the solenoid and, therefore, must be ordered separately (See solenoid accessories). A = Service Conversion ratio: inch = mm ; pounds = g = Kg GAS-NPT thread adapters available at page 1.117 4.43

direct drive 3-WaY vacuum solenoid s WiTH low absorption electric coil The direct drive 3-way vacuum solenoid s of this series feature two positions with conical shutters servo-controlled by the vacuum. As a standard they are normally supplied closed, but upon request they can also be provided as normally open. They are composed of an anodised aluminium body where the connections are located, two silicon shutters assembled onto a stainless steel stem and a membrane in special reinforced compound. A activated by a built-in electric coil manages the servo-control vacuum. The operating principle of these solenoid s is based upon the pressure differential between the vacuum pump or generator and the pressure of the sucked air. By directing this differential pressure to the servo-control via the solenoid pilot, it is possible to control the shutters with no need for compressed air or springs. Due to their operating principle, these solenoid s are not recommended for low vacuum level plants (below 850 mbar abs., equal to 15 % of vacuum). The absence of springs, frictions and internal dynamic stresses favours a high response speed and guarantees a long lasting operation. The electric coil of the is fully plasticised plasticised with synthetic resin, tight execution, insulation class F (up to 155 C) compliant with VDE standards, with 3 mm 2-terminal electrical connections in compliance with EN 175301-803 (ex DIN 43650) -C. Protection degree IP 54; IP 65 for inserted. Available for voltages of 12-24V/50-60Hz and 12-24V/CC. Allowed tolerance on the voltage nominal value: ±10%. Maximum electric power: 2 W The can be rotated by 180 on the coil and can be supplied, upon request, with Led lights, anti-interference circuit and/or with protection devices against overvoltage and polarity reversal. A push-button device built-in the allows the opening and closing of the solenoid. The solenoid s of this series can be used in almost all the cases described for the 07.. 11 series, and also on plants with no compressed air. The solenoid must always be chosen according to the capacity and, therefore, to the vacuum pump or generator suction connection. Working pressure: from 0.5 to 850 mbar abs. Temperature of the sucked fluid: from -5 to +60 C R= Passage A Max. capacity Vacuum level Reaction time Ø F Weight mbar abs. msec section Ø cum/h min max exc. deexc. orifice mm 2 Ø kg 07 03 43 NC g1/2 20 850 0.5 33 17 15 176 6.5 1.35 07 03 43 NO 22 20 07 04 43 NC g3/4 40 850 0.5 33 17 20 314 6.5 1.30 07 04 43 NO 22 20 Note: Please specify the electric coil voltage in the order (E.g.: 07 03 43 NC V24-CC) The is not integral part of the solenoid and, therefore, must be ordered separately (See solenoid accessories). R= Passage R= R= Passage A = = Service P = = Pump Pump 4.44 Conversion ratio: inch = mm g ; pounds = = Kg GAS-NPT thread adapters available at page 1.117

direct drive 3-WaY vacuum solenoid s WiTH low absorption electric coil 4 solenoid pilot A Max. capacity Vacuum level Reaction time Ø Passage F Weight mbar abs. msec section Ø cum/h min max exc. deexc. orifice mm 2 Ø kg 07 05 43 NC g1 90 850 0.5 42 20 25 490 6.5 1.65 07 05 43 NO 28 22 Note: Please specify the electric coil voltage in the order (E.g.: 07 05 43 NC V24-CC) The is not integral part of the solenoid and, therefore, must be ordered separately (See solenoid accessories). Conversion ratio: inch = mm ; pounds = g = Kg GAS-NPT thread adapters available at page 1.117 4.45

3-WaY vacuum solenoid s WiTH BisTaBle impulse solenoid PiloT and WiTH low absorption electric coil These solenoid s have the same functions and structure as the previously described ones. Their distinctive feature is a bistable impulse solenoid activated by a built-in low absorption electric coil which, at a simple electric impulse, exchanges the shutter position even in absence of electricity, until it receives a new impulse of opposite polarity. For this reason, they can only be supplied with DC electric coils. They are particularly recommended in all those cases that require a safe connection to the vacuum source, even in absence of electricity. The electric coil of the is fully plasticised plasticised with synthetic resin, tight execution, insulation class F (up to 155 C) compliant with VDE standards, with 3 mm 2-terminal electrical connections in compliance with EN 175301-803 (ex DIN 43650)-C. Protection degree IP 54; IP 65 for inserted. Available for voltages of 12-24V/CC. Allowed tolerance on the voltage nominal value: ±10%. Maximum electric power: 1 W The can be rotated by 180 on the coil and can be supplied, upon request, with Led lights, anti-interference circuit and/or with protection devices against overvoltage and polarity reversal. The push-button device for their cannot be installed on these solenoid s. Technical features Working pressure: from 0.5 to 850 mbar abs. Temperature of the sucked fluid: from -5 to +60 C A Max. capacity Vacuum level Reaction time Ø Passage F Weight mbar abs. msec section Ø cum/h min max exc. deexc. orifice mm 2 Ø kg 07 03 63 NC g1/2 20 850 0.5 33 17 15 176 6.5 1.35 07 03 63 NO 22 20 07 04 63 NC g3/4 40 850 0.5 33 17 20 314 6.5 1.30 07 04 63 NO 22 20 Note: Please specify the electric coil voltage in the order (E.g.: 07 03 63 NC V24-CC) The is not integral part of the solenoid and, therefore, must be ordered separately (See solenoid accessories). 4.46 Conversion ratio: inch = mm g ; pounds = = Kg GAS-NPT thread adapters available at page 1.117

3-WaY vacuum solenoid s WiTH BisTaBle impulse solenoid PiloT and WiTH low absorption electric coil 4 solenoid pilot A Max. capacity Vacuum level Reaction time Ø Passage F Weight mbar abs. msec section Ø cum/h min max exc. deexc. orifice mm 2 Ø kg 07 05 63 NC g1 90 850 0.5 42 20 25 490 6.5 1.05 07 05 63 NO 28 22 Note: Please specify the electric coil voltage in the order (E.g.: 07 05 63 NC V24-CC) The is not integral part of the solenoid and, therefore, must be ordered separately (See solenoid accessories). Conversion ratio: inch = mm ; pounds = g = Kg GAS-NPT thread adapters available at page 1.117 4.47