CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH



Similar documents
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

How To Test A Power Switch On A Power Supply

ASCO SERIES 185 Power Transfer Switches

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

ATC-300 Automatic Transfer Switch Controller

RM4TG20 three-phase network control relay RM4-T - range V

SWITCHGEAR. EGP Switchgear

CTS SERIES AUTOMATIC TRANSFER SWITCH

Continuous Power... Continuous Protection

Arc Terminator Active Arc-Resistant Switchgear

Transfer switch BTPC open, closed or delayed transition

STRATO LED Drivers 70W, Single output

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Bulletin 150 SMC Flex Smart Motor Controller Specifications

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Secondary Unit Substations

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

GTEC transfer switch open transition

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Sample - No Commercial Use

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Rotary Disconnect Switch Specifications

Three-phase monitoring relay CM-PFE

7.5 Watt AC-DC Switch Power Supply

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

SMC -3 Specifications

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Foxboro Evo Process Automation System

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

EVlink Electric Car Charging Stations Powering the Future of Sustainable Mobility

Telephone- and leased line modem for industrial applications TD-36

D1U54P-W HxxC Series 54mm 1U Front End AC-DC Power Supply Converter PRODUCT OVERVIEW FEATURES

Diesel Engine Driven Generators Page 1 of 6

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

SURGE PROTECTIVE DEVICES

SECTION DETECTION AND ALARM

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

SUGGESTED SPECIFICATION for Service Entrance Automatic Transfer Switches

Power Management Module 2. Installation

Electronic overload relay EF65, EF96 and EF146

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

15 Series - Electronic step relay and dimmer. Features SERIE

Switchgear Capabilities. NexGear is a Division of PowerSecure NASDAQ: POWR

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Voltage Regulator SPAU 341 C. Product Guide

MAJORSINE Power Inverter

Bimetallic Overload Relay Specifications

Rack mounted telephone- and leased line modem for industrial applications

Medium Voltage Motor Control Assemblies

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Power Supplies 3. SDN-P DIN Rail Series

Eaton Automatic Transfer Switches

Tmax MCCBs. Molded case circuit breakers. Tmax

DIESEL GENERATOR SETS

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

Electronic overload relay EF19 and EF45

Analog signal converters CC-E I/I Current / current isolators

Redundancy Module QUINT-DIODE/40

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

MCC Ratings. Voltage Rating

Distribution Dry Type Transformers

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Bolted contact switches. Pringle switches

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

12V Dimmable Driver EL-TMDRVR

R.C.C.B. s two-pole LEXIC

Engineers Edge, LLC PDH & Professional Training

Bulletin 1489 Circuit Breakers. Selection Guide

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

ANSI Watthour Meter Testing & Certification Programs

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

3500/62 Process Variable Monitor

Transcription:

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a compact package. The open transition power case switch-based Automatic Transfer Switch (ATS) will provide fully functioning transfer in applications where a momentary loss of power is acceptable on retransfer from emergency to normal power supply. The Cat power case switch-based ATS also permits periodic testing of the emergency source without interrupting power to the loads and are available from 200 to 5000 amperes. FEATURES ATC-800 microprocessor-based controller Voltage and frequency sensing Fastest switching times available (<3 cycles). Full 60-cycle short time withstand capability Multiple field programmable time delays Switch position indication Source availability indication Safe manual transfer under load. Source 1 and 2 auxiliary contacts Programmable plant exerciser System test pushbutton Load shed from emergency Mimic diagram True RMS three phase voltage sensing on Source 1, Source 2 and Load Frequency sensing on Source 1 and Source 2 Mechanical (cable) and electrical interlocking to prevent paralleling of sources. Safe manual operation under full load with permanently affixed operating handle Ambient temperature range: -40 C to 40 C (-40 F to 104 F). Operating temperature range: -20 C to 70 C (-4 F to 158 F). Operating humidity: up to 90%. Relative humidity (non-condensing) Source paralleling duration is limited to 100 msec or less Source availability indication LEHE0065-03

OPTIONS Closed transition Open transition Suitable for service entrance Integral overcurrent protection 2 or 4-position test switch Multi meter options available Selectable Automatic or Non-Automatic operation Space heaters (recommended for use in NEMA 3R enclosures) Load sequencing contacts Surge suppression Remote communications Controller availability: ATC-100, ATC-300+, and ATC-800 Field selectable, multi ratio, control voltage transformer 50/60 Hz OPTIONAL DELAYED TRANSITION INCLUDES: Time Delay Neutral In-Phase Transition Pre-Transfer Signal with 1 N.O. and 1 N.C. contacts RATINGS Fixed Mount 200-3200A 2, 3, or 4 Pole Drawout 200-5000A 2-, 3-, 4-pole 120 600 Vac 50/60 Hz 100,000 amps withstand/closing/ interrupting at 600 Vac 100% rated Short Time Withstand 85,000 for 30 cycles UL 1008 listed CSA C22.2 No. 178 certified IBC 2006, CBC 2007 and OSHPD CONTROLS AND WIRING All control relays and industrial-grade relays are totally encapsulated to minimize exposure to dust and dirt. Lugs are 90ºC rated and all control wire is #16 AWG, type XLPE with a 125 C temperature rating. ENCLOSURE Durable powder-coated steel NEMA 1, 3R, or 12 enclosures with three door hinges to ensure proper support of the door and door mounted devices. The enclosures are Seismic Qualified (BOCA, CBC, IBC, UBC). The hinges have removable hinge pins to facilitate door removal for easy wall mounting or service and are supplied with pad-lockable latches. LEHE0065-03 2

TESTING STANDARDS UL 991 UL standards for safety tests for safety-related controls employing solid-state devices IEC 1000-5 Surge withstand tests NEMA ICS 109.21 Impulse withstand test UL 1008 Dielectric test (endurance, withstand, etc.) CSA conformance C22.2 No. 178-1978 (reaffirmed 1992) IEEE 472 (ANSI C37.90A) Ringing wave immunity/voltage surge test EN55022 (CISPR11): Conducted and radiated emissions EN61000-4-2 Class B Level 4 ESD immunity test EN61000-4-3 (ENV50140) radiated RF, electromagnetic field immunity test EN61000-4-4 Electrical fast transient/burst immunity test EN61000-4-5 IEEE C62.41: Surge immunity test EN61000-4-6 (ENV50141) Conducted immunity test EN61000-4-11 Voltage dips and interruption immunity FCC Part 15 Conducted/radiated emissions (Class A) CISPR 11 Conducted/radiated emissions (Class A) IEC 1000-2 Electrostatic discharge test IEC 1000-3 Radiated susceptibility tests IEC 1000-4 Fast transient tests UL 869A Reference Std for Service Equipment UL 50/508 Enclosures NEMA ICS 1 General standards for industrial control system NEMA ICS 2 Standards for industrial control devices, controllers, and assemblies NEMA ICS 6 Enclosures for industrial controls and systems NEMA ICS 10-1993 AC automatic transfer switches ANSI C33.76 Enclosures NEC 517, 700, 701, and 702 National Electrical Code NFPA 70 National Fire Protection Agency NFPA 99 Health care facilities NFPA 101 Life safety code NFPA 110 Emergency and standby power systems EGSA 100S Standard for transfer switches CSA C22.2 No. 178-1978 Canadian Standards Association UL 1008 ENDURANCE TESTING RATE OF ATS RATING OPERATION WITH WITHOUT (Ampheres) PER MINUTE CURRENT CURRENT TOTAL 0-300 1 6000 --------- 6000 301-400 1 4000 --------- 4000 401-800 1 2000 1000 3000 801-1600 0.5 1500 1500 3000 1601-4000 0.25 1000 2000 3000 LIFE EXPECTANCY IN YEARS MINIMUM WITH WITHOUT ATS RATING OPERATIONS CURRENT CURRENT (Ampheres) PER YEAR APPLIED APPLIED 0-300 52 115 115 301-400 52 76 76 401-800 52 38 57 801-1600 52 28 57 1601-4000 52 19 57 LEHE0065-03 3

UL 1008 WITHSTAND AND CLOSE-ON RATINGS (ka) Rating When Used with: Upstream Circuit Upstream Fuse Breaker Ampere 3-Cycle 30-Cycle Rating 600 V (ka) 600 V (ka) 800 100 85 1000 100 85 1200 100 85 1600 100 85 2000 100 85 2500 100 85 3200 100 85 4000 100 85 5000 100 85 FIXED MOUNT POWER BREAKER-BASED TRANSFER SWITCH 200 3200A Ampere Number Shipping Rating of Poles Height Width Depth Weight Lbs. (kg) NEMA 1 Enclosed Fixed Mount Transfer Switch 200-2000 2 90 (2286) 32 (813) 48 (1219) 1050 (477) 200-2000 3 90 (2286) 32 (813) 48 (1219) 1050 (477) 200-2000 4 90 (2286) 32 (813) 48 (1219) 1250 (568) 2500-3200 2 90 (2286) 44 (1118) 48 (1219) 1900 (863) 2500-3200 3 90 (2286) 44 (1118) 48 (1219) 1900 (863) 2500-3200 4 90 (2286) 44 (1118) 48 (1219) 2000 (910) NEMA 3R Enclosed Fixed Mount Transfer Switch 200-2000 2 90 (2286) 32 (813) 63 (1600) 1600 (727) 200-2000 3 90 (2286) 32 (813) 63 (1600) 1600 (727) 200-2000 4 90 (2286) 32 (813) 63 (1600) 1800 (818) 2500-3200 2 90 (2286) 32 (813) 63 (1600) 2400 (1091) 2500-3200 3 90 (2286) 32 (813) 63 (1600) 2400 (1091) 2500-3200 4 90 (2286) 32 (813) 63 (1600) 2500 (1136) Dimensions in Inches (mm) & Approximate Shipping lbs (kg) LEHE0065-03 4

DRAWOUT BREAKER-BASED TRANSFER SWITCH 200 5000A Ampere Number Shipping Rating of Poles Height Width Depth Weight Lbs. (kg) NEMA 1 Enclosed Drawout Transfer Switch 200-2000 2 90 (2286) 32 (813) 60 (1524) 1600 (727) 200-2000 3 90 (2286) 32 (813) 60 (1524) 1600 (727) 200-2000 4 90 (2286) 32 (813) 60 (1524) 1900 (864) 2500-3200 2 90 (2286) 44 (1118) 60 (1524) 2500 (1136) 2500-3200 3 90 (2286) 44 (1118) 60 (1524) 2500 (1136) 2500-3200 4 90 (2286) 44 (1118) 60 (1524) 2800 (1273) 4000-5000 2 90 (2286) 86 (2184) 71 (1803) 4150 (1886) 4000-5000 3 90 (2286) 86 (2184) 71 (1803) 4150 (1886) 4000-5000 4 90 (2286) 86 (2184) 71 (1803) 4175 (1898) NEMA 3R Enclosed Drawout Transfer Switch 200-2000 2 90 (2286) 32 (813) 75 (1905) 2100 (955) 200-2000 3 90 (2286) 32 (813) 75 (1905) 2100 (955) 200-2000 4 90 (2286) 32 (813) 75 (1905) 2400 (1089) 2500-3200 2 90 (2286) 44 (1118) 75 (1905) 3000 (1364) 2500-3200 3 90 (2286) 44 (1118) 75 (1905) 3000 (1364) 2500-3200 4 90 (2286) 44 (1118) 75 (1905) 3300 (1500) 4000-5000 2 90 (2286) 86 (2184) 87 (2210) 4250 (1932) 4000-5000 3 90 (2286) 86 (2184) 87 (2210) 4250 (1932) 4000-5000 4 90 (228/6) 86 (2184) 87 (2210) 4275 (1943) Dimensions in inches (mm) and approximate shipping lbs (kg) All dimensions and weights are approximate and subject to change without notice and are not for construction use. Information contained in this publication may be considered confidential. Discretion is recommended when distributing. Materials and specifications are subject to change without notice. CAT, CATERPILLAR, their respective logos, Caterpillar Yellow, the Power Edge trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. www.cat-electricpower.com LEHE0065-03 (04-12) LEHE0065-03 5 2012 Caterpillar All Rights Reserved. Printed in U.S.A.