Sound Pressure Measurement



Similar documents
Noise. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH. Johns Hopkins University

Noise. CIH Review PDC March 2012

FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER

Acoustic Terms, Definitions and General Information

MICROPHONE SPECIFICATIONS EXPLAINED

The Sonometer The Resonant String and Timbre Change after plucking

Resonance in a Closed End Pipe

Basic Concepts of Sound. Contents: Definitions db Conversion Sound Fields db ± db

APPLICATION NOTE AP050830

The Effects of Ultrasonic Sound Generated by Ultrasonic Cleaning Systems on Human Hearing and Physiology

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Sound absorption and acoustic surface impedance

Voltage. Oscillator. Voltage. Oscillator

ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1

AN-007 APPLICATION NOTE MEASURING MAXIMUM SUBWOOFER OUTPUT ACCORDING ANSI/CEA-2010 STANDARD INTRODUCTION CEA-2010 (ANSI) TEST PROCEDURE

Transmitter Interface Program

Spectrum Level and Band Level

Manual Analysis Software AFD 1201

User's Guide. Integrating Sound Level Datalogger. Model Introduction

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Sound Power Measurement

Relationship between Sound Pressure and Sound Power Levels

Experiment 5. Strain Gage Measurements

A Tutorial on the Decibel

What is sound? Why do we measure sound? What units do we use? How do we hear? What instruments do we use for measurement? What is a weighting network?

A-145 LFO. 1. Introduction. doepfer System A LFO A-145

User's Guide Integrating Sound Level Datalogger Model

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

10EaZy SW White Paper Choosing the right hardware

The Calculation of G rms

Building Design for Advanced Technology Instruments Sensitive to Acoustical Noise

Copyright 2008 Pearson Education, Inc., publishing as Pearson Addison-Wesley.

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

Electrical Resonance

Dash 18X / Dash 18 Data Acquisition Recorder

General Thoughts on Generator Set - Acoustic Solutions & Noise Control

Dash 8Xe / Dash 8X Data Acquisition Recorder

CHAPTER 6 Frequency Response, Bode Plots, and Resonance

Aircraft cabin noise synthesis for noise subjective analysis

Computer Networks and Internets, 5e Chapter 6 Information Sources and Signals. Introduction

Experiment 1: SOUND. The equation used to describe a simple sinusoidal function that propagates in space is given by Y = A o sin(k(x v t))

Schindler 3300 / Schindler 5300 Information on noise and vibration.

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

The Role of Acoustics in Curtain Wall Design:

Yerkes Summer Institute 2002

Acceleration of Gravity Lab Basic Version

SPEECH INTELLIGIBILITY and Fire Alarm Voice Communication Systems

Lab 3: Introduction to Data Acquisition Cards

Integrating Sound Level Meter and Datalogger

SE05: Getting Started with Cognex DataMan Bar Code Readers - Hands On Lab Werner Solution Expo April 8 & 9

Trigonometric functions and sound

Kit Watt Audio Amplifier

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p

Workshop Perceptual Effects of Filtering and Masking Introduction to Filtering and Masking

Linear Parameter Measurement (LPM)

Airborne Sound Insulation

Author: Dr. Society of Electrophysio. Reference: Electrodes. should include: electrode shape size use. direction.

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

application note Directional Microphone Applications Introduction Directional Hearing Aids

Step-by-Step RECD Guide

Welcome to the United States Patent and TradeMark Office

Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B

AP1 Waves. (A) frequency (B) wavelength (C) speed (D) intensity. Answer: (A) and (D) frequency and intensity.

What Audio Engineers Should Know About Human Sound Perception. Part 2. Binaural Effects and Spatial Hearing

Lab 1: The Digital Oscilloscope

RC Circuits and The Oscilloscope Physics Lab X

Reading assignment: All students should read the Appendix about using oscilloscopes.

Pulse Width Modulation (PWM) LED Dimmer Circuit. Using a 555 Timer Chip

RLC Series Resonance

Audio Editing. Using Audacity Matthew P. Fritz, DMA Associate Professor of Music Elizabethtown College

The front end of the receiver performs the frequency translation, channel selection and amplification of the signal.

Lab 4 - Data Acquisition

Mass Loaded Vinyl A review of the performance and cost in acoustical applications

Understanding the DriveRack PA. The diagram below shows the DriveRack PA in the signal chain of a typical sound system.

Introduction to acoustic imaging

Active noise control in practice: transformer station

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

Estimation of Loudness by Zwicker's Method

RANDOM VIBRATION AN OVERVIEW by Barry Controls, Hopkinton, MA

Noise at work a guide for health and safety representatives

ACOUSTICAL CONSIDERATIONS FOR EFFECTIVE EMERGENCY ALARM SYSTEMS IN AN INDUSTRIAL SETTING

Video Baby Monitor System. User Guide

DT3: RF On/Off Remote Control Technology. Rodney Singleton Joe Larsen Luis Garcia Rafael Ocampo Mike Moulton Eric Hatch

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Music technology. Draft GCE A level and AS subject content

1. Learn about the 555 timer integrated circuit and applications 2. Apply the 555 timer to build an infrared (IR) transmitter and receiver

Overview of the Telecommunications Network

The Design and Implementation of Multimedia Software

Tuning Subwoofers - Calibrating Subwoofers

FREE FALL. Introduction. Reference Young and Freedman, University Physics, 12 th Edition: Chapter 2, section 2.5

A wave lab inside a coaxial cable

Experiment 5. Lasers and laser mode structure

Ultrasonic Wave Propagation Review

Filter Comparison. Match #1: Analog vs. Digital Filters

ReSound Unite TV FREQUENTLY ASKED QUESTIONS. Setup & Configuration. Use & Operation. Troubleshooting

Generic - Hearing Loop - (AFILS) U.S. System Specification

MUSC 1327 Audio Engineering I Syllabus Addendum McLennan Community College, Waco, TX

SOUND MEASURING INSTRUMENTS

Transcription:

Objectives: Sound Pressure Measurement 1. Become familiar with hardware and techniques to measure sound pressure 2. Measure the sound level of various sizes of fan modules 3. Calculate the signal-to-noise ratio of acoustic measurements 4. Investigate the noise of the fan modules as a function of size and operating speed Background Sound can be described as a tiny variation in air pressure, detected by some receiver. Typical sound pressure amplitudes range from a few micropascals to a few hundred Pascals that fluctuate around atmospheric pressure (~101,000 Pascals). This variation in air pressure travels as a longitudinal wave, i.e. a compression wave, which propagates throughout the medium (air) at a velocity called the sound speed. In air at 20 C, the speed of sound is about 344 m/s. In general, the tiny variation of pressure oscillates very rapidly in time around the atmospheric pressure. In the audio-range, these oscillations occur between 20 and 20,000 times per second. In other words, audible sound is made up of frequencies between 20 and 20,000 Hz. The frequency components in this wave are perceived as different tones and pitches by the human ear. 20 Hz corresponds to a very low pitch while 20,000 Hz corresponds to a very high pitch. Most noises are composed of many different frequencies. The Brüel and Kjær Type 2236 Precision Integrating Sound Level Meter, as shown in Figure 1, can be used to measure the magnitude of sound pressure levels (SPL s). Common reasons that sound pressure level is measured include: 1. The evaluation of noise emanating from a product to determine how the product could be made less annoying to customers. For example, automotive companies perform these measurements to determine the sound that a car engine produces when it is running. The Department of Transportation takes SPL readings to measure noise coming from interstate highways. 2. The measurement of noise to evaluate if an environment is damaging to human ears. For example, a factory must evaluate the noise level that the workers are exposed to while working. This involves comparison of the levels measured to published standards by regulating agencies such as OSHA (Federal Occupational Safety and Health Administration). One of the most important components of a sound level meter is the microphone Most of the high quality sound level meters have a condenser microphone. This type of microphone is constructed with a thin metal foil stretched like a drumhead over a frame. It is always protected by a guard because it is fragile. When the slight changes in pressure, caused by a sound wave, reach this diaphragm, the diaphragm moves relative to a rigid metal backplate. The capacitance (the ability of two closely spaced metal plates to store energy in an electric field) changes with the movement of the diaphragm. This change in capacitance is converted to a milli-volt signal, which goes on to a preamplifier. The preamplifier in a microphone-sound measurement system is always positioned as close as possible to the microphone to reduce the magnitude of the electrical noise in the signal. The signal then goes to other amplifier stages and then to an analog- 1

to-digital converter where it is quantified digitally. The sound signal can then be filtered, measured and stored by the data acquisition systems introduced earlier in this manual Microphone On/Off switch Figure 1. Bruel & Kjær 2236 Precision Integrating Sound Level Meter. The location of the microphone and on/off button are shown. The LCD display at the bottom shows the sound level reading (Bruel & Kjær, 2003). A condenser microphone can be of two different types. A free-field-response microphone is made to measure sound which is coming from one direction only. This would be the case if the measurement was being made outside or in a place where the sound did not reflect off any walls or other objects, such as an anechoic chamber. An anechoic (an means no, echoic echo) chamber is a room that has been prepared to minimize sound reflections off its walls so that a free-field microphone can be used. A random-incidence microphone is made to measure sound equally from all directions. This type of microphone must be used when reflections or multiple sound sources produce an environment where there is more than one path from the source(s) to the microphone. Sometimes a random-incidence microphone is used to measure sound which is coming from one direction only. In this case, the microphone axis should be turned at 70 to 80 from the line between the source and the microphone to minimize the error from using the wrong type of microphone. The measurements will have reduced accuracy if the proper type of microphone is not used. The Brüel and Kjær Type 2236 Sound Level Meter comes with a type 4188 free-field response microphone. As an additional feature, the sound level meter comes with an adapter that makes the free-field microphone have a similar response to a random-incidence microphone. This is to avoid the cost of having two separate microphones for each measurement situation. 2

Sound pressure level is the measurement of sound strength on a logarithmic scale (this is the base ten logarithm, not the natural logarithm, Ln ). The measurement was derived at Bell Labs in the 1930 s as a way of comparing the power of a sound level to a reference value. The unit of a Bell was first defined there. Because a Bell is a small value, sound level meters read in deci- Bells (db), or more commonly spelled, decibels. The following equations define the sound pressure level of a certain noise. L = SoundPressureLevel = 10 log(signal Power/Reference Power) Because the power of the acoustic signal is related to the square of the RMS pressure, this equation can be rearranged and written as: L = 20 log( P / P ) (2) rms reference where P represents pressure. The reference value for sound in air, P reference, is 20 micropascals. The RMS pressure is the square root of the integral over a certain time period of the square of the pressure divided by the time period. T 1 2 Prms = p ( t) dt T (3) 0 An integrating sound level meter measures p(t) with a microphone and computes duration T) and finally displays the sound pressure level in db. 1 2 P rms (1) (over a set Because the sound pressure level is measured on a logarithmic scale, the sound pressure level resulting from two combined sources is not the algebraic sum of the two separately measured levels. One must convert the individual measurements back to a linear value and then add them together before converting back to a logarithmic scale. If three sources with individually measured sound pressure levels of L1, L2,andL 3 are combined, the total sound pressure level will be as shown in equation 4: L T L T = 10log 10 + 10 + 10 L1 L2 L3 10 10 10 Sound level meters often have the ability to measure noise with four weighting networks. These weighting networks are labeled as dba dbc, dbl and db xxxhz on the Brüel and Kjær Type 2236 meter. The dbl setting measures the loudness of all frequencies with the same sensitivity. The A and C weightings allow the user to measure the lower frequencies of sound with less sensitivity than others.. The purpose of this unequal sensitivity is to model the response of the human ear. The human ear is not as sensitive to the lower frequencies in its range. When the signal is passed through a filter that has a similar frequency response as the human ear, you can obtain a measure of the loudness of the sound that corresponds to the perception of an average human listener. The A network, measured in dba is the most common weighting used today. In addition to weighting networks, bandpass filters are often used to measure the amplitude of sound within a certain range of frequencies. Although this range could be any width, sound is usually separated into octaves. An octave is an interval of frequencies where the highest frequency is twice the lowest frequency. For example, the span of frequencies between 707 Hz and 1414 Hz are one octave because 2 x 707 = 1414. A filter, which rejects all frequencies lower (4) 3

than 707 Hz and also rejects frequencies above 1414 Hz, is called a single octave bandpass filter. This filter would normally be designated by the frequency in the center of its range, in this case 1000 Hz. The relationship of the center frequency to the upper and lower cutoff frequencies is given in the following equations. This is only for a one-octave bandpass filter 1 f = f f = 2 lower center upper center 2f (5) Therefore, an octave bandpass filter with a center frequency of 1000 Hz, filters out all frequencies from the sound being measured except those between 707 Hz and 1414 Hz. Using several bandpass fitters, one can investigate which frequencies are contributing the most to the total SPL. The B&K 2236 meter has one octave band pass filters with center frequencies of 31.5, 63, 125, 250, 500, 1000, 2000, 4000, and 3000 Hz. INSTRUCTIONS I. Calibration (perform this ONLY if directed to by your instructor!) It is important to calibrate a sound level meter each time it is used, so ask your instructor if the meter needs to be calibrated. 1. While the sound level meter is mounted on a tripod, carefully remove the random incidence adapter if it is installed on the microphone and put it in a safe place. Turn the sound level meter on by pressing the button, which is labeled with a red circle and a short green line. 2. Insert the microphone into the Brüel and Kjær calibrator. Make sure that the microphone is inserted until it bottoms out inside the calibrator. 3. Press the Frequency Wt. buttons to set the weighting to dbl. If the OVL letters are shown on the display, press the reset button (which has a curved line and an arrow). 4. Turn on the calibrator by pressing its On/off button. 5. The display should now show approximately the emitted value of the calibration signal. 6. Press the Show button twice to start the calibration procedure. 7. Press Edit once to continue. 8. Press OK to check the status of the present calibration. (If an error occurs, go back to step 3 and set the weighting to dbl) 9. Press OK after the screen returns with the results of its test 10. Press OK again to exit the calibration routine. 11. Turn off the calibrator and remove it from the microphone. II. Measurement of Sound Pressure Levels. The sound level meter will be used to determine the effect of combining multiple sound sources, transmission loss, and signal-to-noise ratio (SNR). If directed by your instructor, take your measurements inside the anechoic chamber. Keep in mind for this case that the measurements can be considered as free-field. 4

1. Set the parameters of the sound level meter to the following. Power Button On Press the button with the red circle Displayed Parameter SPL Press the Parameter buttons Level 20-100 db Press the Level buttons Time Weighting F (fast) Press the button labeled.f.s.i Frequency Weighting dba Press the Frequency Wt. button The display should appear as. 2. Place the sound source, the fan module Number 1, in the acoustic experiment box. If the acoustic experiment box is used inside the anechoic chamber, leave the lid to the box open. Turn on the fan measure, and measure the sound level in dba using at least three different speeds by varying the voltage level on the power supply. For the lower voltages, if the fan doesn t start by itself, try giving the blade a push to overcome the starting torque. A LabView VI (SPL Data Logger.vi) has been written to help automate the process of gathering data. There is a computer in the soundproof room adjacent to the anechoic chamber. Double-click the icon for the VI to start it. 3. Measure the background noise in acoustic box by quietly watching the display while no sound sources are turned on. This is the background noise level. Take a background measurements before each measurement when the fan is turned on. 4. Repeat step 1 and 2 for fan modules number 2 and 3. 5. Calculate the signal to noise ratio of the SPL levels. III. Measurement of Fan Speed After you have taken SPL measurements, you will measure the fan speeds using a reflective optosensor and an oscilloscope. A small piece of white tape has been placed on one of the fan blades for each fan. When the optosensor is placed near the tape, a voltage pulse can be observed on the oscilloscope once for each revolution of the fan blade. 1. Ask your instructor to verify that the optosensor is wired properly. 2. Set the oscilloscope to make a frequency measurement (which will be in Hz, so you ll need to convert to RPM). 3. Measure the fan speeds at the voltages you used when making the noise measurements. References Bruel & Kjær 2236 Precision Integrating Sound Level Meter data sheet, http://www.bksv.com/pdf/bp1535.pdf, 2003. 5

Data Sheet Acoustics: Measurement of Sound Pressure Level Measurement Data Description of Fan 1: Description of Fan 2: Description of Fan 3: Source (Fan Module #): Voltage Level Fan Speed dba Background Noise SNR Source (Fan Module #): Voltage Level Fan Speed dba Background Noise SNR Source (Fan Module #): Voltage Level Fan Speed dba Background Noise SNR 6