Fläkt Woods Building Future



Similar documents
PFT Two stage axial fan The high pressure fan for modern boiler plants

Green Buildings. Energy Efficient Air Climate Solutions ENERGY EXPERTISE ENVIRONMENT

Solutions for Building Air Comfort and Fire Safety

Precise Air Management Product Range > Car Park Ventilation

ECODESIGN by FLÄKT WOODS EU REGULATION 1253 AND 1254/2014 FOR RESIDENTIAL AND NON-RESIDENTIAL VENTILATION UNITS

HEATING, VENTILATION & AIR CONDITIONING

HVAC Systems: Overview

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

eq Top/TopMaster Air Magic by Fläkt Woods

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings

- White Paper - Data Centre Cooling. Best Practice

HVAC Processes. Lecture 7

THE ErP DIRECTIVE 2009/125/EC KEY FACTS» REGULATIONS 327/ /2009. ErP. - Version 2.0

Delivering exceptional performance and Ecovalue. Ecocent

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

Preliminary Final Proposal

Drives and motors. A guide to using variable-speed drives and motors in retail environments

Energy Efficient HVAC-system and Building Design

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Energy Efficiency HOSPITALITY.

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

How To Design A Building In New Delhi

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

Heating, ventilation and air conditioning equipment. A guide to equipment eligible for Enhanced Capital Allowances

LG Electronics AE Company, Commercial Air Conditioning

imagine SOLAR AIR CONDITIONING MADE EASY

ASTACEA4 Inspect complex/central air conditioning systems

Active & Passive Beams

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

State of the Art Energy Efficient Data Centre Air Conditioning

Direct Fresh Air Free Cooling of Data Centres

Lesson 36 Selection Of Air Conditioning Systems

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Heating, ventilation and air conditioning (HVAC) equipment. A guide to equipment eligible for Enhanced Capital Allowances

System solution for data centres

Combi Unit Genius. The energy efficient Building Service Centre

Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone.

Data Centres A complete solution to noise control and acoustic packages

Analysis of data centre cooling energy efficiency

Small-Scale Solar Heating and Cooling Systems

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction

Integrated Solar Radiant Systems

Subtropical Cities September Design for Energy Efficiency in Commercial Buildings in Queensland

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

Building Energy Systems. - HVAC: Heating, Distribution -

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

We have been working in an ideal climate for thirty years.

Defining Quality. Building Comfort. Precision. Air Conditioning

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

Energy Efficiency. Bars & RestauRants.

Element D Services Heating, Ventilating, and Air Conditioning

Acoustic Design Practices for Sustainable Buildings

Heating Systems for Low Energy Buildings

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology

Head: The new space race

Drives and motors. A guide to using variable-speed drives and motors in data centres

Glossary of HVAC Terms

ALBUQUERQUE PUBLIC SCHOOLS Facility Design & Construction / Maintenance & Operations

Radiant Panels and Chilled Sails.

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Venice Library Humidity Study. for Williams Building Diagnostics, LLC th Street West Bradenton, FL Report April 13, 2015

How To Get A Passive House

CAN DEMAND CONTROLLED VENTILATION REPLACE SPACE HEATING IN OFFICE BUILDINGS WITH LOW HEATING DEMAND?

All the best brands all under one roof

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

Screw Compressors ESM Fixed Speed & VS Variable Speed

Crowne Plaza Copenhagen Towers The world s greenest hotel

Technology Guide. Air conditioning. Maximising comfort, minimising energy consumption

University of St Andrews. Energy Efficient Data Centre Cooling

Example of audit of an air conditioning system

Life cycle cost comparison of TAB vs. other HVAC (UK) TECHNICAL BROCHURE

newsletter engineers energy-saving strategies for Water-Source Heat Pump Systems volume 36 2 providing insights for today s hvac system designer

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

Commissioning - Construction Documents (Page 1 of 6)

How to Build a Data Centre Cooling Budget. Ian Cathcart

The Different Types of Air Conditioning Equipment for IT Environments

APC APPLICATION NOTE #112

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects

Challenges and Failures in Green Building Design Using Under-Floor Air Distribution. Ken Urbanek, PE, HBDP, LEED AP Director of Engineering

Air Conditioning in Green Office Buildings?

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

News in Data Center Cooling

How To Make Your House Breathe

Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM

SAM HOUSTON STATE UNIVERSITY

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Can old buildings be just as energy-efficient as new ones?

AN APPLICATION MANUAL FOR BUILDING ENERGY AND ENVIRONMENTAL MODELLING

ENHANCED LABORATORY HVAC SYSTEM

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

Blade Server & Data Room Cooling Specialists

Comparing Energy Savings of Different VAV Systems

Transcription:

Energy, Expertise and Environment with Fläkt Woods Fläkt Woods Building Future Saving energy in building ventilation

You must save 20% on energy before 2020. Following the Kyoto protocol the European Union has set a target to reduce energy consumption. For buildings the target is set at a 20% reduction by 2020. The 160 million buildings in the EU use over 40% of Europe s energy and create over 40% of its carbon dioxide emissions. And unfortunately that proportion is increasing. Therefore the Commission of the European Union has issued The Energy Performance of Buildings Directive (EPBD). The directive has been in force since January 2003. Local legislation and time-tables in membership states are being developed. Reducing the energy use of buildings without compromising the indoor environment and services is the key challenge for Europe. EPBD Facts Issued by the Commission of the European Union Directive in force since 2003 Local legislation to ratify directive under way 20% reduction by 2020 Viable for all buildings, domestic and non-domestic

Fläkt Woods e 3 Concept makes it come true. To address the needs created by the EPBD directive, Fläkt Woods has poured a lot of effort into creating the e 3 Concept. Our solution is a broad approach leaving no stone unturned to achieve optimum results. High-performing components are an obvious starting point. With over one hundred years of experience that is what our customers have come to expect from us over the years. Utilizing the latest technology to create smart solutions is achieved through experience coupled with massive R&D investments. Being a large global player we have got what it takes. But it is by combining products into a system, utilizing smart controls, one can achieve the best energy solutions. This strategy requires that the systems and individual components are designed together. It takes thorough knowledge of the individual products impact on each other and the ultimate combined effect. Luckily Fläkt Woods develop and produce components as well as design systems. That's why we can combine the parts into harmonic overall solutions. ENERGY EXPERTISE ENVIRONMENT

Problem: Energy consumption in buildings We spend approximately 80% of our time indoors. The indoor environment is becoming more and more important. A lot of energy resources are consumed to maintain the right temperature and air quality. Normally we say that 30% of the energy is spent on ventilation, another 30% for cooling and 30% for heating. (The last 10% is for the ligthing and technical installations.) With ventilation representing a third of the consumption we have a lot to work with. But we can also affect both heating and cooling through the ventilation system. Together that means that you can make an impact on somewhere about half of the total energy consumption of a building Lighting and technical installations 10% Heating 30% Cooling 30% something worth considering! Ventilation 30%

Solution: Energy efficient systems Reducing the energy consumption in a building through ventilation can be achieved following some principal routes: Avoid wasting energy As a start you might take a look at what you are presently using and consider if that is necessary. A good example is the ventilation of spaces like cafeterias and conference rooms. They are typically ventilated according to peak demand. But in real life only fully occupied for short periods of time. We have solutions that addresses this waste. We call it Demand Control Ventilation. Reusing energy An obvious energy approach is also to reuse the heat and cooling. This can be achieved for instance with our Econet solution with recovery rates up to 70%. Intelligent design Different situations call for different requirements. Cooling down the building on a hot day requires large volumes of air to be transported. Heating the same premises on a slightly chilly day is achieved with a fraction of that effort. Traditional ventilation systems have a constant airflow. We use variable air velocity (VAV) that varies with demand. That means considerable savings in fan drive energy. Downsizing Using compact integrated system design one can achieve the required effect with reduced energy consumption. The combination of the chilled beam, chiller and our Econet units reuses cooling refrigrerant and reduces the amount of liquid. Smaller pipe dimensioning and size of pumps can in some cases reduce the chiller load with up to 50%. LCC sums it all up Within the industry we use an analysis designing ventilation systems. It balances the cost of better components and smarter system control with savings in maintenance and energy costs over the systems life time. Not surprisingly a smarter system comes out on top. About 85% of the life time cost is typically energy costs, 10% initial investment and 5% maintenance. COST Energy 85% Investment 10% Maintenance 5% SAVING TIME

Integrated advantages Econet Chillers Econet is an integrated Air Handling Unit. It integrates heating, cooling and energy recovery into one component. Due to better heat recovery from the exhaust air the need to heat the supply air can be reduced by up to 40%. Econet can also control a liquid based cooling system with considerable savings in overall energy consumption range of chillers are designed to minimise the overall annual energy consumption in all types of buildings. Demand controlled ventilation Demand controlled ventilation provides desired ventilation based on the actual occupancy of the room. It increases indoor air quality and saves energy normally wasted in ventilating unoccupied spaces. This can be applied to areas where there are frequent changes in occupancy, such as conference rooms, board rooms, cafeterias etc. Field experience indicates that actual occupancy levels are at least 25% lower and perhaps as much as 60% lower. In normal office building the offices are not occupied more than 60% of the time during a normal working day. This means that demand controlled ventilation can reduce ventilation as well as heating and cooling loads by 10% 30%. ENERGY CONSUMPTION Energy consumption air transportation ReCooler - Energy efficient cooling unit for eq air handling units CONSTANT AIR VOLUME VARIABLE AIR VOLUME DEMAND CONTROLLED VENTILATION grated in the air handling unit with exceptionally low energy consumption. ReCooler offers the added feature of a built-in rotary heat exchanger, designed to provide sensible and latent cooling recovery, which reduces the energy consumption for cooling by 20%.

Chilled beams In systems with Chilled Beams, the indoor air is cooled by means of cold water. Chilled beams create a stable and comfortable environment by supplying draught free cooling. By using Chilled Beams up to 75% of the total cooling capacity will be handled by the water. Apart from the energy saving it also means less ductwork for air, smaller air handling units and lower noise. Air Volume Control Flow variators are products for the control and adaptation of airflows in VAV (Variable Air Volume) systems. The system saves costs and energy because the flow and cooling effects are adapted to the actual demand in the room, with the result that the total flow for the air treatment units is reduced. Integrated Controls These are areas where savings typically can be made. The savings potential must however be analysed considering existing installations and specific circumstances on a case-by-case basis. The heart of the Demand Control Ventilation adapted the thinking into our control package. This strategy provides a way to create maximum indoor air quality to minimum energy cost. FWG offers integrated control solutions based on open communication protocols enabling further integratation with other systems in the building. Integrated control systems reduce installation cost and maximize functionality turning products into energy efficient systems.

We Bring Air to Life Fläkt Woods is a global leader in air management. We specialise in the design and manufacture of a wide range of air climate and air movement solutions. And our collective experience is unrivalled. Our constant aim is to provide systems that precisely deliver required function and performance, as well as maximise energy efficiency. Solutions for all your air climate and air movement needs Fläkt Woods is providing solutions for ventilation and air climate for buildings as well as fan solutions for Industry and Infrastructure. Air Handling Units (AHUs) Modular, compact and small AHU units. Designed to ensure optimisation of indoor air quality, operational performance and service life. Air Terminal Devices and Ducts Supply and exhaust diffusers and valves for installation on walls, ceiling or floor are all included in our large range and fit all types of applications. Chilled Beams Active induction beams for ventilation, cooling and heating, and passive convection beams for cooling. For suspended or flush-mounted ceiling installation and multi-service configuration. With unique Comfort Control and Flow Pattern Control features. Residential ventilation A complete range of products for residential ventilation. Consists of ventilation units, exhaust air fans and cooker hoods designed to optimise indoor comfort and save energy. Energy recovery Dessicant-based product and systems that recover energy, increase ventilation and control humidity. Fans Advanced axial, centrifugal and boxed fans for general and specialist applications. Comprehensive range including high temperature and ATEX compliant options. Engineered for energy efficiency and minimised life cycle cost. Chillers Air-cooled and water-cooled chillers with cooling capacity up to 1800kW. Designed to minimise annual energy consumption in all types of buildings. Controls and drives Variable speed drives and control systems, all tested to ensure total compatibility with our products. Specialist team can advise on energy saving and overall system integration. Acoustical Products A complete line of sound attenuating products, including rectangular and round silencers, Media Free silencers, custom silencers and acoustic enclosure panels. FWG-EPBD Sales Brochure- GB-11-8536 CCJ Kommunikation Fläkt Woods Group SA 18, avenue Louis Casaï, CH-1209 Geneva, Switzerland Tel. +41 22 309 3800 email info@flaktwoods.com www.flaktwoods.com See global website for international sales offices www.flaktwoods.com