10 Multimeter. Users Manual



Similar documents
1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Model UT201/202: OPERATING MANUAL. Table of Contents

HVAC Clamp Meter. Users Manual

UT202A Operating Manual. Contents

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

AutoRanging Digital MultiMeter

Model UT33A: OPERATING MANUAL Table of Contents (1)

Manual Ranging MultiMeter

User's Guide. True RMS Industrial Multimeter

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

i410/i1010 AC/DC Current Clamp

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Model 77 Series IV Digital Multimeter

115C and 117C. True-rms Multimeters. Users Manual

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

1587/1577. Insulation Multimeters. Users Manual

ABCs of DMMs Multimeter features and functions explained Application Note

Fluke 3000 FC Series Test Tools Technical Data

Table of Contents. Page

How To Use A Cdm250 Digital Multimeter

Fluke 3000 FC Series Test Tools Technical Data

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

323/324/325. Calibration Manual. Clamp Meter

Model UT60A: OPERATING MANUAL. Table of Contents. Page

7 FUNCTION DIGITAL MULTIMETER

Model UT58A/B/C: OPERATING MANUAL

User Guide. 4 wire Earth Resistance Tester Model GRT300

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

User Guide. Model Insulation Tester / Megohmmeter

Intelligent Digital Multimeters

Instruction Manual IDM 71/72/73 Digital Multimeter EN FR IT DE

Model UT713 OPERATING MANUAL

Fluke 1650B Series Multifunction Installation Testers

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

Ground Resistance Clamp On Tester

Multifunction Process Calibrator

Model UT71A/B OPERATING MANUAL

AVO410. Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter

Temperature Humidity Meter

DIGITAL MULTIMETER OPERATION MANUAL ITEM DIGITAL MULTIMETER CONTENTS

Owner s Manual & Safety Instructions

1. SAFETY INFORMATION

Loop Calibration and Maintenance

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Essential Electrical Concepts

Dual Display Digital Multimeter

Ground Resistance Clamp-On Tester

Owner s Manual & Safety Instructions

Seven function digital multimeter

Multimeter measurements on variable frequency drives using the new Fluke 289 DMM

Instructions A Amp AC/DC Current Probe

AMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Integrating Sound Level Meter and Datalogger

INTRODUCTION SAFETY PRECAUTIONS/

Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Current Probes. User Manual

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

What is a multimeter?

Digital Clamp-on DMMs with uncompromising performance

Thermistor Thermometer MODEL NO

Electrical Safety Tester Verification

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Handheld portable appliance testers

Thermocouple Thermometer Models

MEGGER Insulation & Low Resistance Tester

Table of Contents. Page No.

CO-220 Carbon Monoxide Meter

62 Max/62 Max + Infrared Thermometer

Model 1756 Test Lead Kit

INSTRUCTION MANUAL. NC-500 NETcat Pro Wiring Tester

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

Insulation resistance testing. A complete solution for every person.

Mini Power Bank and Charger

Antenna Splitter ASA 1. Instruction manual

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

Table of Contents. Title

How To Use The Visifault Visual Fault Locator

aseries A13B Mini Bullet Camera User Manual

User Manual. CFG253 3 MHz Function Generator

RS DIGITAL THERMOMETER

The Basics of Digital Multimeters

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

INSTRUCTION MANUAL IPM Phase Power Analyser EN FR IT DE ES

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

Broadband Telecommunications Drop Amplifier

This document lists specifications for the NI PXIe-4139 (NI 4139) precision system sourcemeasure

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Transcription:

10 Multimeter Users Manual 1991-2001 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies.

10 MULTIMETER m m Mk SELECT RANGE OFF VDC VAC COM 600V acz06f.eps

10 Users Manual Contents Page Read First -- Safety Information... 2 Contacting Fluke for Service, Accessories, or Parts... 3 Standby Mode... 4 Operating Features... 5 Using Accessories... 6 Symbols... 6 Using the Autorange and Manual Range Modes... 7 Measuring Voltage... 8 Testing Continuity And Measuring Resistance... 10 Turning the Beeper Off... 10 Testing Diodes... 12 Maintenance... 14 Replacing the Battery... 14 Specifications... 15 1

10 Users Manual Read First -- Safety Information W Warnings and Cautions To ensure that the meter is used safely and to avoid damage to the meter: Use the meter only as described in this manual, or the protection provided by the meter might be impaired. Verify the meter s operation by measuring a known voltage. Do not use the meter if the meter or test leads look damaged, or if you suspect that the meter is not operating properly. If in doubt have the meter serviced. Replace the battery as soon as the low battery indicator (N) appears to avoid false readings that can lead to shock and injury. Turn off power to the circuit under test before cutting, unsoldering, or breaking the circuit. Small amounts of current can be dangerous. Do not apply more than 600 V rms between a terminal and earth ground. Use caution when working above 60 V dc or 30 V ac rms. Such voltages pose a shock hazard. Keep your fingers behind the finger guards on the probes when using the probes. Disconnect the live test lead before disconnecting the common test lead. 2

Contacting Fluke for Service, Accessories, or Parts This meter should be serviced only by a qualified service technician. To order the 10 Series Service Manual (PN 900824), accessories, parts, or to get other information, contact Fluke at one the phone numbers listed below: 1-888- 993-5853 in USA and Canada 31 402-678-200 in Europe 81-3-3434-0181 Japan 65-738-5655 Singapore 1-425-446-5500 in other countries Visit Fluke s web site at www.fluke.com. Address correspondence to Fluke at: Fluke Corporation Fluke Europe B.V PO Box 9090 PO Box 1186 Everett, Washington 98206-9090 5602 BD Einhoven USA The Netherlands 3

10 Users Manual Replace Battery Digital Reading Manual Range m m Mk Measurement Units Continuity Beeper Enabled Diode Test Note: Before using, peel off plastic lens protector, starting at any corner. Figure 1. Display acz01f.eps Standby Mode In Standby mode, the display goes blank to preserve battery life. The meter beeps and enters Standby if it is LEFT ON BUT IS INACTIVE for more than 45 minutes. Press any button to resume operation. 4

Operating Features Operating Features Toggle Between Volts DC and AC, or Continuity and Ohms SELECT Ranging Operations RANGE 3-Position Slide-Switch Volts DC/AC Position OFF VDC VAC Continuity/Diode Test, and Ohms Common (Return) Jack COM 600V Input Jack Figure 2. Operating Features acz02f.eps 5

10 Users Manual Using Accessories When using accessories, put the slide-switch in the volts position. For ease of reading, manually select the 4000 mv range. In the 4000 mv range, 1 mv corresponds to 1 unit being measured by the accessory. Symbols W Important Information; see manual G Diode B AC (Alternating Current) J F DC (Direct Current) T t Underwriters Laboratories, Inc # N Battery. Low Battery on Display. R Earth Ground Double Insulation VDE (Verband Deutscher Electroniker) Continuity Beeper 6

Using the Autorange and Manual Range Modes Using the Autorange and Manual Range Modes The range for each function determines the highest value the meter can measure. If the range is too low, the meter displays OL (overload) and beeps. If the range is too high, the display shows fewer digits of resolution. The meter has an autorange and manual range mode. In autorange, the meter selects the range automatically. The meter defaults to autorange when you turn it on. In manual range, you lock the meter in a range. To manually select a range: 1. Press [Z] RANGE to lock the meter in the present range. Z is displayed. 2. Press [Z] RANGE to step through the ranges. NOTE: The 4000 mv range, which can only be entered in manual range, is convenient when using accessories. 3. To return to autorange, press [Z] RANGE for 2 seconds (until Z is no longer displayed), or change the measurement function. 7

10 Users Manual Measuring Voltage 1. Insert the test leads in the jacks. 2. To select a voltage function, put the slide-switch in the middle position. (Figure 3.) Press the [g] SELECT button to toggle between dc and ac. 3. Touch the probes to the test points, and read the display. The meter beeps when OL (overload) is displayed. 8

Measuring Voltage Volts DC Volts AC 10 MULTIMETER 4 10 MULTIMETER 4 SELECT SELECT RANGE 2 RANGE OFF 2 OFF VDC VDC VAC VAC 600V COM 1 600V COM 1 _ 3 3 Figure 3. Measuring Voltage acz03f.eps 9

10 Users Manual Testing Continuity And Measuring Resistance 1. Insert the test leads in the jacks, and turn off power to the circuit under test. External voltage across the components causes invalid readings. 2. Put the slide-switch in the continuity / ohms position (Figure 4). The meter selects the continuity/diode or ohms function. Press [g] SELECT to toggle between the continuity / diode ( R G ) and ohms (e) functions. 3. Touch the probes to the test points. In ohms, read the resistance on the display. In continuity test, the beeper sounds continuously if continuity exists (resistance <25 Ω). Opens and shorts longer than 250 µs are detected. Turning the Beeper Off To disable beeper functions, press and hold down [Z] for 2 seconds while turning the meter on. 10

Turning the Beeper Off Resistance Continuity Test 10 MULTIMETER k 4 10 MULTIMETER 4 10 MULTIMETER SELECT SELECT SELECT 2 RANGE 2 RANGE RANGE OFF OFF OFF VDC VDC VDC VAC VAC VAC 600V COM 1 600V COM 1 600V COM 3 3 Short Open Figure 4. Continuity Test and Resistance Measurement acz04f.eps 11

10 Users Manual Testing Diodes 1. Insert the test leads in the jacks. 2. Put the slide-switch in the continuity / ohms position. The meter selects either the continuity / diode ( R G ) or ohms (e) function. If ohms is selected, press [g] SELECT to toggle to the continuity/diode function. To toggle the beeper on or off in continuity/diode test, press [Z} RANGE. When the beeper is enabled, R is displayed. 3. Touch probes to the diode (Figure 5A). A forward-voltage drop of about 0.6 V (typical for a silicon diode) causes the meter to beep once. 4. Reverse probes (Figure 5B). If the diode is good, OL is displayed. If the diode is shorted (Figure 5C), the beeper sounds continuously in at least one direction. If the diode is open, OL is displayed in both directions. 12

Testing Diodes 10 MULTIMETER 10 MULTIMETER 10 MULTIMETER SELECT SELECT SELECT 2 RANGE RANGE RANGE OFF OFF OFF VDC VDC VDC VAC VAC VAC 600V COM 1 600V COM 600V COM 3 4 A B C Figure 5. Testing Diodes acz05f.eps 13

10 Users Manual Maintenance W Warning To avoid electrical shock or damage to the meter, do not get water inside the case, and remove the test leads and any input signals before opening the case. Wipe the case with a damp cloth and detergent. Do not use abrasives or solvents. Replacing the Battery W Warning Replace the battery as soon as the low battery indicator (N) appears to avoid false readings that can lead to shock and injury. To replace the battery: 1. Turn the meter OFF and remove the test leads from the meter. 2. Remove the four screws from the back of the meter and lift off the front. 3. Remove the battery and replace it with a 9 V battery (NEDA 1604 or IEC 6F22). 14

Specifications Specifications This meter complies with Part 15 of FCC Rules. Operation is subject to the following conditions: 1. This meter may not cause harmful interference. 2. This meter must accept any interference received, including interference that may cause undesired operation. Accuracy is specified for a period of one year after calibration, at 18 C to 28 C (64 F to 82 F) with relative humidity to 90 %. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy Specifications are given as: /- ( [ % of reading ] number of least significant digits ] ) 15

10 Users Manual Maximum Voltage Between any 600 V rms Terminal and Earth Ground Display 3 3/4-digits, 4000 counts, updates 4/sec Operating Temperature 10 C to 50 C Storage Temperature 30 C to 60 C indefinitely (to 40 C for 100 hrs) Temperature Coefficient 0.1 x (specified accuracy) / C (<18 C or >28 C) Relative Humidity 0 % to 90 % ( 10 C to 35 C); 0 % to 70 % (35 C to 50 C) Battery Type 9V, NEDA 1604 or IEC 6F22 Battery Life Alkaline, 650 hrs continuous; Carbon-zinc, 450 hrs continuous Shock, Vibration 1 meter shock. Vibration per MIL-T-28800D for a Class 3 Instrument Size (H x W x L) 1.35 x 2.75 x 5.55 inches; (3.46 x 7.05 x 14.23 cm) Weight 10 oz (286 g) Safety Complies with Protection Class II requirement of UL1244, ANSI/ISA-S82, CSA C22.2 No 231, and VDE 0411, and IEC 1010 overvoltage CAT III. CAT III instruments are designed to protect against transients in fixed-equipment installations at the distribution level. EMI Regulations Complies with FCC Part 15, Class B, and VDE 0871B. 16

Specifications Function Range Resolution Accuracy (50 to 400 Hz) VB 4000 mv * 4.000 V 40.00 V 400.0 V 600 V VF 4000 mv * 4.000 V 40.00 V 400.0 V 600 V Ω 400.0 Ω 4.000 kω 40.00 kω 400.0 kω 4.000 MΩ 40.00 MΩ 1 mv 0.001 V 0.01 V 0.1 V 1 V 1 mv 0.001 V 0.01 V 0.1 V 1 V 0.1 Ω 0.001 kω 0.01 kω 0.1 kω 0.001 MΩ 0.01 MΩ /- (2.9 % 3) /- (2.9 % 3) /- (2.9 % 3) /- (2.9 % 3) /- (2.9 % 3) /- (1.5 % 2) /- (1.5 % 2) /- (1.5 % 1) /- (1.5 % 1) /- (1.5 % 1) /- (1.5 % 2) /- (1.5 % 1) /- (1.5 % 1) /- (1.5 % 1) /- (1.5 % 1) /- (1.9 % 3) RG 2.000 V 0.001 V /- (1.5 % 2) ** * The 4000 mv range can only be entered in manual range mode. Use the 4000 mv range with accessories. ** The beeper is guaranteed to come on at <25Ω and turn off at >250Ω. The meter detects opens or shorts of 250 µs or longer. 17

10 Users Manual Function Overload Protection * Input Impedance (Nominal) Common Mode Rejection Ration (1 kq Unbalance) Normal Mode Rejection VF 600 V dc >10 MQ <100 pf 50 Hz or 60 Hz 100 db @ dc @ 50 or 60 Hz >50 db @ 50 or 60 Hz VB 600 V rms >5 MQ <100 pf (ac-coupled) Ω Open Circuit Test Voltage >60 db, dc, 60 Hz NA Full Scale Voltage Short Circuit Current To 4.0 MΩ 40 M Ω 600 V rms < 1.5 V dc <450 mv dc <1.5 V dc <500 µa G 600 V rms 2.4 to 3.0 V dc 2.400 V dc 0.95 ma typical * 3 x 10 6 V Hz Maximum 18