Gas Sample Probe Series SP

Similar documents
S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

2.12. page Products for Explosion hazardous Environment

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

BB-18 Black Body High Vacuum System Technical Description

Assisted lift operated 2/2-way solenoid valves Type EV250B

S300 Series Dust Monitors

Plastic tube flowmeters Series PT/PS

ThermoSorb Desiccant Dryers

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Kompressoren. Adsorption Dryer AD

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Solenoid valves 2/2-way direct-operated Type EV210A

FlowPak TM General Application Valve 1/2-4, Class 150

API Marine. BMS Presentation. Ballast Measurement Systems

Compact pressure switch Flameproof enclosure Ex d Model PCA

Control- and feedback head for integrated mounting on Robolux valves Type 2036

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Thermatel Model TA1 Mass Flow Transmitter

Combi switchbox with integrated 3/2 way pilot valve

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

Adsorption air dryers ADS 1 215

Digital inductive conductivity transmitter

Micro Motion 3098 Gas Specific Gravity Meter

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

COMBIMASS. Technical Data COMBIMASS eco-bio +

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

How To Use A Flowmeter

Typical Aluminum GFM Mass Flow Meter

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

Terminal Box. Specifications TNCN

How To Use A Ds340 (Dsp)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

SEISMIC VELOCITY TRANSDUCER T1-40

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

type V46, solenoid or pneumatic operated

S1VF Sonde à visser avec tête de raccordement Threaded probe with terminal head

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for Gases

Instruction Manual. T3111 T3111L T3111P T3111Ex

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Under sill units. Type FSL-B-ZAS

Type 3353 Angle Seat Valve

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

Confidential. Proportional reducer D386 ATEX. Male base connector View from weld side

Bypass level indicator With magnetic display Model BNA

Explosion proof enclosures

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Solenoid valves Type EVU

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Micro Motion Model D and DL Coriolis Flow and Density Meters

Bulk Flow Meter LB 442 P R O C E S S C O N T R O L

2/2 & 3/2 Solenoid operated valves

Solenoid Valve Island Type 3965

Rotary screw compressors kw 5,5 7, , bar MODULO

Capteur température et humidité pour HVAC

CAPACITIVE LEVEL METERS CLM 36

Pressure calibration equipment

DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0.

Variable Area Flowmeters

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Centro-Matic Automatic Lubrication Systems System Controls

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Duct Humidity Transmitter

DUST EMISSION MONITORING SYSTEM

Self-operated Temperature Regulators Temperature Regulator Type 1u

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

SITRANS F flowmeters SITRANS F M

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Self Purging Liquid Trap (SPLT ) User s Manual

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

System 8. ü ( System 8

Variable V Area Flowmeter Rotameter The Original

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

3/2-way Solenoid Valve, direct-acting, NC or NO

swimming pool accessories

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Battery Powered Thermal Mass Flow Meters for Gases

Hose and Tube Fittings Series 1-3

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Installing a Probe. Typical Installation

Butter y valves Plastic and Metal

3/2-way Mini Solenoid Valve

Technical data sheet TDS0070

4/2-Way Pneumatic Solenoid Valve

Rotary Actuators, NAMUR interface VDI/VDE 3845 & ISO 5211 (ATEX certified) Series ARP

Transcription:

Embracing Challenge Gas Sample Probe Series SP Version SP3110V and SP3110 for sampling from zones with explosive gas with different options for calibration gas feeding, back purging and shut-off SP3110V/RS/HEX4-135 resp. 180 Special Features Approval according to ATEX for sampling from Ex-zone 1 and 2 Approval according to ATEX for mounting in Ex-zone 1, 2 or 21, 22 Different options for test gas feeding, back purging and shut-off Optimum operational reliability Universal applicability Adaption to nearly all process conditions due to its compact and modular design Easy mounting and maintanance Small volume, fast response time Application The M&C sample probes version SP3110V and SP3110 are used for continuous extraction of explosive gases (Ex-zone 1 and 2) from dust loaden, high temperature and/or humid processes. The probes can be mounted in Ex-zone 1, 2 or 21, 22. Both versions differentiate only in the sealing material of the filter housing. Version SP3110V has got a sealing out of FPM for types which are heated up to max.185 C and version SP3110 has got a sealing out of graphite for all versions heated up to more than 185 C. Description The sample probes are designed for easy installation, reliable operation and troublefree maintenance. They are versatile in application and depending on the task to be performed, various pre-filters series V12 or V20 with integrated volume displacer, optional with extension tubes, not included in the scale of delivery, can be simply screwed into the mounting flange of the basic probe. For error control the sample gas flow rate has to be monitored externally. This M&C stainless steel or ceramic filter element with a large surface and high capacity is located in the external housing. The design offers little or no stagnant space outside the process. The probe housing is covered with a protection shield which is part of the Ex-approval. The probes are designed in such a way that changing the filter element is possible without the use of tools. In this operation, neither the sample probe tube nor the sample line need to be removed, thus avoiding contamination of the clean gas path and maintaining the integrity of the system. The special design of the optional heating of the M&C-probes version SP3110(V) permits controlled heating of the complete filter housing, including the mounting flange. This ensures reliable operation external to the process preventing the temperature falling below the dew-point. The temperature control of the M&C-probes version SP3110(V) can be done by three different heater types. The first possibility is a self-regulating heater version HEX4-135 or HEX4-180 (see data sheet 2-3.2) for Ex-zone 1 or 21, for gas sampling from zone 1 or 2. In dependence on the ambient temperature and the heater type, the min. temperature in the probe is 90 C resp. 120 C, the max. temperature is 120 C resp. 160 C. The second possibility is a controlled heating version HEX1-3 for Ex-zone 1, adjustable up to 180 C and for sampling from Ex-zone 1 or 2. The controller has to be mounted outside the Ex-zone. The third possibility is a controlled heating version HEX1-1 for Ex-zone 1, adjustable up to 180 C and for sampling from Ex-zone 1 or 2. The controller can be mounted inside the Ex-zone. For calibration gas feeding or back-purging different options are possible. For example the option RS with mounted buffer vessel triggered by an explosion-proof solenoid valve is available. With the mounted option for back-purging type RS, gas can be sampled from zone 1 and 2. The back-purge pressure has to be monitored externally and has to be min. 1 bar higher than the process pressure. For the pressure control while back-purging, a corresponding special valve is mounted in the sample gas outlet. Thus an additional solenoid valve to shut off the sample gas outlet is not necessary. The back purge inlet is shut off by a check valve. When sampling from Ex-zones, back purging is only allowed with a gas suitable for the sampling point.

Technical Data Gas sample probe type SP3110V (up to 185 C) SP3110 (more than 185 C) 20S5615 20S5610 Weather protection shield yes Filter housing material Stainless steel 316 / 316Ti Sealing materials Graphite, FPM Graphite Probe flange sealing material Graphite Pre-filter / sample tubes optional, see data sheet 2.14 and 2.17 Sample pressure max. 0,5- Ambient temperature -20 C to +60 C Permissible process gas temperature depending on the temperature class, however max. 200 C at the probe entry Filter chamber volume 120 cm 3 Filter element, porosity F-3SS150= stainless steel*, 3 micron S-2K150= ceramic**, 2 micron let connection 1x 1/4 NPTi for max. 8mm-tube connectors gas outlet at option RS 6 mm Swagelok connector Mounting flange DN65 PN6, FormB, SS316Ti* >DN or ANSI possible** Weight 7 kg II 2G/2GD -20 C Ta +60 C EXAM BVS 04 ATEX H 045X Option heating type HEX4 HEX4-135 HEX4-180 20S5510 20S5520 Mounting controller in the Ex-zone 1, 2, 21 and 22 Control self-regulating 115V - 230V 50/60Hz Electrical connection cable gland, terminal range 7-12mm, terminals max. 4mm 2 II 2 G EEx em T3..T4 / II 2 D IP66 135 C...180 C EXAM BVS 04 ATEX E 253 Case protection IP66; EN60529 Power 400W Max. temperature 120 C 160 C Min. temperature 90 C 120 C Ambient temperature -20 C to +60 C Low temperature alarm contact <60 C, 1 contact MC-NO, 230V 1,5A AC, 0,5ADC <100 C, 1 contact MC-NO, 230V 1,5A AC, 0,5ADC Option heating type HEX1 HEX1-3 20S9037 (a) Mounting controller outside the Ex-zone Control electronic 230V 50/60Hz or 115V 50/60Hz (a) Electrical connection 3 x 1,5mm 2 II 2 G EEx d ib IIC T3*, others on request Power 400W Case protection IP54; EN60529 Temperature 0-180 C T3 or 0-135 C T4 Ambient temperature -20 C to +40 C Low temperature alarm contact <120 C, 1 change-over contact, 230V 1,5AAC, 0,5ADC Option heating type HEX1 HEX1-1 20S9038 (a) Mounting controller inside the Ex-zone 1, 2 Control electronic 230V 50Hz or 115V 60Hz (a) Electrical connection 3 x 1,5mm 2 II 2 G EEx d e ib IIC T3*, others on request Power 400W Case protection IP54; EN60529 Temperature 0-180 C T3 Ambient temperature -20 C to +40 C Low temperature alarm contact <120 C, 1 change-over contact, 230V 1,5AAC, 0,5ADC * Standard, ** optional

Technical Data Gas sample probe type SP3110V (up to 185 C) SP3110 (more than 185 C) Option back purge unit type RS RS 20S5560 (a) 230V 50/60Hz 9W or 115V 50/60Hz 9W (a) Electrical connection cable 3x1mm 2 II 2GD EEx m II 135 C G 1/2 i at the buffer vessel Max. back purge pressure Volume buffer vessel 2 liters Ambient temperature -20 C to 60 C Option 2-way-ball valve in the probe entrance /VA 20S9050 Operating temperature -20 C up to 185 C Option 2/3-way-ball valve in the probe entrance Backflush / Test gas connection Operating temperature Option pneum. drive for ball valve /VA o. /3VA control air Pressure control air /3VA 20S9325-20 C up to +185 C MS1 20S9055 G1/4 i 5-10 bar Option valve for blowback or calibration gas 1/4 /R 20S9045 Opening pressure Maximum blow back pressure Maximum operating temperature +185 C Option variable calibration gas feeding /R + /CC and /CCF 20S9045 + 20S9012 Way of test gas /R/CC = via sample gas outlet or /R/CCF = via probe filter element Check valve /R check valve 1/4 Opening pressure Maximum blow back pressure Maximum operating temperature +185 C Option high performance blow back valve /BB /BBF 20S9008 20S9006 Way of blow back gas via filter chamber via probe filter element Check valve high performance check valve 3/8 Opening pressure 8mm tube Maximum blow back pressure Maximum operating temperature 185 C Option test gas valve / shut-off valve /C + /I 20S9011 + 20S9009 Way of test gas via sample gas outlet with shut-off to the process Check valve check valve 1/4 Opening pessure Shut-off valve bellow-type valve with pneumatic drive Pressure control air 3-10 bar control air 1/8 NPT i Option second sample gas outlet /2X 20S9015 1/4 NPT i Option spun glass cartridge /FW 20S9047 20S9046 Material SS316Ti, Novapress SS316Ti, Graphite * Standard, ** Option

Combinations of options Option No. 1 2 3 4 5 6 7a 7b 8 9 10 /RS /VA /3VA /MS1 /R /R/CC(/CCF) /BB /BBF /C/I /2X /FW /RS X X X /VA X X X X X X X X /3VA X X X /MS1 X X /R X /R/CC(CCF) X X X /BB X X X X /BBF X X X /C/I X X X X X X /2X X X X X X X X = possible combinations X = recommended combinations Differential pressure and T 90 -time P and T90 at flow of: 100 200 500 1000 1500 Nl/hr P with new filter element F-3SS150 0,006 0,012 0,040 0,110 0,215 bar P with new filter element S-2K150 0,003 0,005 0,02 0,058 0,135 bar T90-time for SP3110 without tube 6 3,5 1 <0,5 <0,5 s Dimensions SP3110(V) basic version with option back purging type RS and heating type HEX4 270 40 RS HEX4 140 340 360 440 200 207 133 407 540 Dimensions in mm

Dimensions Option heating HEX1-1 Controller Scale Limiter Reset X1 L1 1 4 1 2 4 3 2 3 N N 2 1 X1.1 6 3 4 5 PA/PE X2 2 1 190 470 210 Dimensions in mm Option heating HEX1-3 130 160 TA- Übertemperatur X2: H2 EExi Betrieb H1 230 N1 (N2) Heizkreis AUS EIN S1 V1 230 X1: Netz AUS EIN EExe X1 Q1 X2 450 Ex-area Zone 1 Non-hazardous area Dimensions in mm

Functional diagram of the options 1 to 9 1 Standard Option /RS back purging I-air Option /MS1 4 I-air Option /MS1 4 2 3 Option /VA Option /3VA back purging/test gas 5 6 Option /R test gas/back purging Option/CC test gas Option /CCF test gas 7a 7b Option /BB back purging Option /BBF back purging I-air 8 9 Option /2 x Option /C/I test gas/shut-off valve Possible combinations of options see table page 3.

Options pre-filter and extension tubes Options Version In situ filtre en acier inoxydable avec réducteur de volume interne, longueur 220mm, diamètre ext. 46mm, porosité 2µm, température V20-0 20 S 9105 max. 600 C, matériau SS316/SS316Ti In situ filtre en Hastelloy avec réducteur de volume interne, longueur 220mm, diamètre ext. 46mm, porosité 2µm, température V20-0/HC 20 S 9115 max. 900 C, matériau Hastelloy C In situ filtre en acier inoxydable avec réducteur de volume interne, longueur 520mm, diamètre ext. 60mm, porosité 2µm, température V20-1 20 S 9145 max. 600 C, matériau SS316/SS316Ti In situ filtre en Hastelloy avec réducteur de volume interne, longueur 520mm, diamètre ext. 60mm, porosité 2µm, température V20-1/HC 20 S 9155 max. 900 C, matériau Hastelloy C In situ filtre en Hastelloy avec réducteur de volume interne, longueur 520mm, diamètre ext. 60mm, porosité 0,5µm, température V20-1/HC 20 S 9156 max 900 C, matériau Hastelloy In situ filtre en acier inoxydable avec réducteur de volume interne, longueur 300mm, diamètre ext. 31mm, porosité 2µm, température V20-3 20 S 9300 max 600 C, matériau SS316/SS316Ti Plus value pour sonde SP2000/V20-3, /V20-4. Extension du filtre in situ en inox type V20-3 ou V20-4 pour chaquelongueur de V20-3 20S9310 100mm suivante à partir de la longueur standard 300mm à...mm. *Longueur maximale totale du filtre 1m.* Matériau acier inox 316. In situ filtre préliminaire texturé avec support et rétrosoufflable, longueur 400mm, diamètre ext. 40mm, porosité 15µm, température V20-T 20 S 9315 max. 200 C, matériau PTFE, SS316Ti In situ tube de filtre en céramique, double enveloppe, avec réducteur de volume interne, Longueur 500mm, diamètre 40mm, V12-1A-1 20 S 9559 porosité 1µm, température max. 1000 C, Matériau céramique, SS316Ti, connexion G3/4" Tube de prolongation pour V20.. avec réducteur de volume interne, longueur 500mm, temp, max 600 C, matériau SS316Ti Vm500 20 S 9165 Tube de prolongation pour V20.. avec réducteur de volume interne, longueur 1000mm, temp. max 600 C, matériau SS316Ti Vm1000 20 S 9170 Tube de prolongation pour V20.. avec réducteur de volume interne, longueur 1500mm, temp. max 600 C, matériau SS316Ti Vm1500 20 S 9175 For choosing the adequate pre-filter see data sheet 2-1.1.0.8 as well Options sample tubes Options Version Part-No. Longueur 1m, matériau SS316Ti, température max. 600 C SP2000/SS 20 S 9065 Longueur 1m, avec réducteur de volume, matériau SS316Ti, température max. 600 C SP2000/SS-Vm 20 S 9067 Longueur 1m, matériau Hastelloy C, température max. 900 C SP2000/HC 20 S 9090 Longueur 1m, matériau Kanthal, température max. 1300 C SP2000/KA 20 S 9080 Longueur 1m, matériau Incoloy 956, température max. 1200 C SP2000/IC 20 S 9072 For choosing the adequate sample tube see data sheet 2-1.1.0.6 as well Temperature classes for sampling from zone 1 or 2 Type SP3110V.. SP3110V.. SP3110V.. SP3110.. SP3110.. Possible Optionen* /RS, /HEX4-135 /RS, /HEX.. /RS Temperatue class Max. process gas temp. ( C) at probe entry Max. surface temperature ( C) T6 80 80 T5 95 95 T4 130 135 T3 195 195 T2 200 200 * all further options mentioned on page 2 and 3 can be used additionally in all temperature classes