Server Technology, Inc.



From this document you will learn the answers to the following questions:

What do you do about the implications of not using safety - approved branch circuit protection?

What part of the PDU is more likely to be damaged by a branch circuit?

What type of branch circuit is more desirable in a data center?

Similar documents
Rack-mount Power Distribution Units and UL

Server Technology Inc.

Data Center Power Overload Protection: Circuit breakers and branch circuit protection for data centers

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Alternating Phase Power Distribution at the Data Center Rack PDU

Mission Critical Data Center Systems

Server Technology, Inc.

Server Technology, Inc.

ELECTRICAL INSPECTION BULLETIN (Effective )

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

Circuit Breakers Supplementary Protectors Manual Motor Controllers

Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability

Arc Flash Mitigation & Selective Co-ordination

Circuit Breakers in Data Centers: The Hidden Danger

misconceptions about arc-flash hazard assessments

Low Voltage Fuses For Motor Protection

Arc Fault Circuit Interrupters Frequently Asked Questions

Data Center Power Distribution at the Cabinet Level: The top 12 questions you need to ask to improve data center energy effciency

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

UL 508A Industrial Control Panels Power Distribution and Control. Lunch & Learn Training Eaton Corporation. All rights reserved.

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Short-circuit current rating (SCCR) of. industrial control panels. NEC Article 409 and UL 508A

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

Who do the biggest names in servers, search, healthcare, cloud & financial services trust to provide power management solutions?

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

Efficiency and Other Benefits of 208 Volt Over 120 Volt Input for IT Equipment

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Understanding Emergency Power Off (EPO)

Understanding HUD s UPCS Protocol for Inspecting Electrical Devices Revised Oct. 2010

8146/5 Series Breaker Panelboards

Bypass transfer switch mechanisms

Distributing Power to Blade Servers

Engineering Series Ratings: Is It Practical?

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

Construction Electrical Terminology. Electricians

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

City of San Diego Residential Photovoltaic Systems Inspection Guidelines

Server Technology Inc.

Includes customer case study. February 28, 2013

Mike Holt s Illustrated Guide to. Rule , Articles 445, 700, 701, and 702. Based on the 2011 NEC

Power Distribution Considerations for Data Center Racks

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Crawford Inspection Services C.C.B. #

Rack Power Distribution. Worldwide

Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation

How SafePlug Smart Receptacles Can Save Money in Commercial Buildings

Server Technology, Inc.

One unbelievable solution for rack-level data center power management. Sentry Power Manager. Solutions for the Data Center Equipment Cabinet

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

Low Voltage Transformer Through-Fault Protection: A System Approach

Commercial/Industrial Electricity

Harmonics in your electrical system

Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes

CONDUCTOR SHORT-CIRCUIT PROTECTION

NEC Class 2 Power Circuits and Power Supplies

High Efficiency Motor Protection. Industry White Paper

CONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 2

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

2011 National Electrical Code Questions & Answers

How do I... POPS Smart & Switched CDU. If you manage a datacenter, we have a solution for you.

How To Power A Bladecenter H Servers

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Top 8. Considerations for Choosing the Right Rack Power Distribution Unit to Fit Your Needs

Questions and Answers for Heating and A/C Contractors

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ

Fundamentals of Power

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

EMERGENCY LIGHTING AND CONTROL

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

Overload Protection in a Dual-Corded Data Center Environment

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Sentron Series Circuit Breakers

SELECTION OF FINAL CIRCUIT PROTECTION

PORTABLE GENERATORS AND OSHA CONSTRUCTION REGULATIONS

APC Step-Down Transformer. User s Manual

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

How To Protect A Motor From Overcurrent

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

SINGLE FAMILY DWELLING ELECTRICAL SERVICES RATED 225 TO 600 AMPS

Power to the adaptable data center

Motor Protection Voltage Unbalance and Single-Phasing

Using Murrelektronik MICO Modules to Create Low Voltage Limited Energy Circuits in Industrial Control Panels according to UL508A.

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

ELECTRIC CONVECTION BUILT-IN OVEN

Transcription:

Server Technology, Inc. Branch Circuit Protection: Power Distribution for IT Equipment in the Data Center Server Technology, Inc. 1040 Sandhill Drive Reno, NV 89521 +1 (775) 284-2000 www.servertech.com

White Paper: Branch Circuits Corporate data centers account for some of the most expensive and sought after real estate in the world today. Enterprises invest huge amounts of capital to design, construct, and secure their investment in IT Equipment (ITE) in the data center. New requirements in the data center require all Information Technology Equipment placed in the data center to meet new UL 60950-1 standards. A key component of this certification for both UL and the National Electric Code (NEC) is Branch Circuit Protection. Without branch circuit protection, enterprises expose themselves to risks and severe consequences. sider these important points and weigh the implications of not utilizing safety-agency approved branch circuit protection in your data center: 1. Building inspectors following local civic codes or the NEC may fault the data center for being in violation of branch circuit protection requirements. 2. Fire or damage to the data center caused by or contributed to a PDU that is not safety-agency certified may not be covered by property & casualty insurance. 3. Additionally, any organization that uses PDUs without safety-agency certification for branch circuit protection in a finished product, or distributes these products, may face a reduction, limitation or exclusion of their product liability coverage, or find that they are not covered in the general liability insurance coverage. What is a Branch Circuit? In a rack Power Distribution Unit (PDU), the power input is often broken into multiple segments. A division of the circuit with current limited by a fuse or circuit breaker is referred to as a branch circuit. In a data center IT environment, a PDU with more than one branch circuit is more desirable than a PDU with a single branch circuit because of the protection it provides by limiting the number of outlets associated with each branch circuit. In the event of an overload to a single outlet on the PDU, the overload will be carried back to the fuse or circuit breaker for the branch circuit. If the PDU has only one branch circuit, all the outlets on the PDU will be affected lost as the PDU has only one (1) fuse or circuit breaker (or the branch circuit protection is provided at the main utility PDU). If the PDU has multiple branch circuits, then only the outlets associated within that branch circuit would be lost; the remaining outlets on the PDU s other branch circuit(s) would not be affected. (See Figure 1). Figure 1 Short- Circuit Utility Source Branch Circuits 1

About New Branch Circuit Protection Requirements PDUs designed for data center equipment cabinets fall into UL s listing for Information Technology Equipment (ITE); UL requires that all new IT equipment submitted for certification be evaluated using the requirements of UL 60950-1. As a key component of this certification, all PDUs safety-agency certified in North America to the new UL 60950-1 standard (CSA/UL/TUV) & the National Electrical Code (NEC) are required to have branch circuit protection for receptacles. This certification states that all standard outlets and receptacles shall be protected by an overcurrent protection device () in the branch circuit, rated or set at not more than the rating of the outlet or receptacle. Furthermore, the requirement states that the shall be of a type that is suitable for branch circuit protection in accordance with the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code, Part 1, CSA 22.1. Additionally, the only option for new Information Technology Equipment (ITE) submitted for certification will be UL60950-1, which does not permit the use of supplementary overcurrent protection for branch circuits. What Does this Mean How does it Differ than Previous Versions? On any given rack-level PDU, each branch circuit must be protected by a fuse or circuit breaker equal to the individual rating of each outlet. For instance, a PDU with 20 Amprated (20A) outlets must have branch circuit protection of 20A, and a PDU with multiple branch circuits must have 20A overcurrent protection (fuse or circuit breaker) for each branch circuit. For a 20A rated PDU, branch circuit protection can be provided by one of two options: On a PDU with a single branch circuit, either an approved must reside within the PDU, or branch circuit protection for the entire PDU can be provided upstream at the main utility PDU or fuse panel. On a PDU with multiple branch circuits, an approved must reside within the PDU for each branch circuit. For a PDU with 30A power input feed(s) and 20A outlets, branch circuit protection on the PDU is an absolute requirement: Each branch circuit of a 30A power feed must have an equal to the rating of each outlet. The prevents cordage attached to the PDU s outlets from exceeding its current rating and causing a potential safety hazard. Additionally, the type of overcurrent device must be of a specific type; circuit breakers must meet UL standard # 489. Most circuit breaker types do not meet the stringent requirements of UL # 489, which includes fault-free overcurrent operation with line faults reaching 5,000 amps. Fuses providing overcurrent protection must meet UL # 248 standards and meet JDDZ designation. 2

How Does this Impact Your Choice of a Rack PDU? 1. To meet the newest safety ratings of the National Electric Code, consider using only PDUs that meet UL 60950-1 standards. 2. For high amperage loads, i.e. 30A per input feed, only a PDU with branch circuit protection will meet the new requirements. 3. PDUs with supplementary circuit breakers will not meet UL 60950-1 criteria. NEC Section 240.10, Supplementary Overcurrent Protection, states: Where supplementary overcurrent protection [i.e., a circuit breaker] is used for [PDUs], it shall not be a substitute for branch-circuit overcurrent devices or in place of the branchcircuit protection. This is the key NEC requirement that mandates the use of listed fuses or circuit breakers when branch circuit protection is needed and is the basis for present requirements in UL 60950-1. For the security and protection of the data center and the enterprise all PDUs, like the Sentry Cabinet Power Distribution Unit (CDU) product family, should be UL 60950-1 certified. Server Technology s Sentry Cabinet Power Distribution Unit (CDU) is the first product family to address the requirements and importance of branch circuit protection in a cabinet or rack PDU. The Sentry CDU products provide branch circuit protection and meet the new UL 60950-1 criteria by providing branch circuit protection with UL-listed Bussman SC fuses for each branch circuit. The Sentry CDU products are available with branch circuit protection for (single-phase) 110V, 208V, 240V and three-phase 208V circuits, and are available in a variety of enclosures all with the UL 60950-1 certification. Sentry CDU products utilize Bussman SC fuses for Overcurrent Branch Circuit Protection 3

Summary: Characteristic Analysis Description/ Reasoning A 20A PDU with no overcurrent protection device; branch circuit protection is provided at the main PDU or circuit/ fuse panel A 20A CDU with an fuse approved for UL60950-1 A 30A PDU with no overcurrent protection device A 30A CDU with an fuse approved for UL 60950-1 A PDU with an circuit breaker approved for UL 60950-1 A PDU with a supplementary circuit breaker Pro Pro While this product does not require branch circuit protection, consider the implications of not having it; if one outlet on the PDU is overloaded, the circuit breaker/fuse for the entire circuit trips/blows and all the connected equipment on that circuit is downed. In the event one outlet is overloaded, the fuse for the corresponding branch circuit will blow, affecting only the outlets on that branch circuit not all outlets on the CDU. Branch circuit protection is an absolute requirement for PDUs with a 30A input feed and individual 20A outlet receptacles. 1.) Branch circuit protection is an absolute requirement for PDUs with a 30A input feed and individual 20A outlet receptacles; and 2.) Fuses provide Fast-acting protection: in the event of a short circuit, the fuse will blow quicker (than a circuit breaker) as a 20A fuse will trip before a 30A breaker; and 3.) Fuses also have an overload time-delay which permits them to pass temporary overloads. 1.) Circuit breakers are mechanical devices, and unlike a fuse, each time they trip or are switched to an off position, it reduces the exact specification is was built to withstand; and 2.) While a circuit breaker can be used as a local power disconnect control, it also has the ability to be accidentally used as a power disconnect. Due to this potential nuisance outage and the importance of maintaining uptime in the data center, we recommend against using circuit breakers; and 3.) The physical size of a UL # 489 rated circuit breaker would not fit within a 1U-wide PDU. A non-ul #489 rated circuit breaker on a PDU is a direct violation of the National Electric Code and UL 60950-1. e 4