HOTCHKISS AIR SUPPLY Heating, Ventilating & Air Movement Equipment



Similar documents
Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

HVAC Duct Construction. Bob Wasilewski Project Manager, Technical Resources SMACNA

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB

How To Design A 3D Print In Metal

General Allowances for Insulation & Cladding

Excerpts from the Canadian National Building Code (NBC)

Flue Installation. High Efficiency Condensing Boilers

Flash Butt Welding Machines

Pipeline design. concrete for life

AZB 800. Vertical Flue Gas Ducting Ø60/100mm

Services Enclosures and Protected Shafts - Maintaining Compartmentation

CHAPTER 29 VOLUMES AND SURFACE AREAS OF COMMON SOLIDS

Grooved gaskets. Types of gaskets

Hose and Tube Fittings Series 1-3

HEAVY DUTY STORAGE GAS

Assembly instructions VOSS quick connect system 246 NX


HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

VCE VET ENGINEERING STUDIES

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Wisconsin Building Products Evaluation

Plunger Cylinder. 1 Description. 2 Technical data

How To Use A Corona Mdi 110

Residential Deck Safety, Construction, and Repair

HANDRAIL STANDARDS HANDRAILS AXESS LADDER SYSTEM KICK FLAT SYSTEM OPEN FLOORING

Introduction to Data Centre Design

LarsLap model C for cutting, milling grinding and lapping seats and flanges on globe, safety and control valves

AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels

BETONYP building boards. The modern way of living.

Post and Beam Construction

4 Installation Requirements

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

Operating Instructions Drill rig DRU160

Transformer Bushings for GIS

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Installation Detailed installation instructions are provided which should be strictly followed.

VOLUME AND SURFACE AREAS OF SOLIDS

Speed-Mat Rectangle Cutter

Manual piston sampler...m 11

Chapter 16. Mensuration of Cylinder

Technical Drawing Specifications Resource A guide to support VCE Visual Communication Design study design

Point K2. D ouble D ynamic T ransport. Vitap.com

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

How To Install A Perfect 16 Id Series Filter System

FIRE DAMPER APPLICATION GUIDE

The WANZ Guide to Window Installation

PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE

MATHEMATICS FOR ENGINEERING BASIC ALGEBRA

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

JIS G3472 Electric Resistance Welded Carbon Steel Tubes for Automobile Structural Purposes

GENERAL RUBBER LINING PRINCIPLES

Part H DIFFUSERS section 2 SEPT Publication. Air Diffusers. supply and exhaust ventilation systems. plenum boxes

DSM 1 (800)

Installation Instructions ERV/PRV Downdraft Vent

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

PROTECH ELECTRICAL CONNECTORS AND CABLE TIES

The WANZ Guide to Window Installation

Mark Cramer Inspection Services, Inc.

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Incorporating V2.3. Product spec >>> > Series ECG - Egg Crate Grilles. > Series ECG45-45 Egg Crate Grilles

How To Order A Direct Flow Air Cleaner

Spiroflex spiral-wound gaskets

SITEMA PowerStroke. Technical Information TI-P12. 1 Function. 2 Applications. Mould Closing Devices series FSKP. Contents

Gulf Cable & Electrical Ind. Co.

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

Type 1 dryers: Domestic dryers to be used primarily in a family living environment. Residences Individual apartments or condominiums

METHOD STATEMENT FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER

TARIFF CODE and updates standard

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

CONTROL DESK SOLUTIONS

Fixed Vertical Access Ladders

Self-operated Temperature Regulators Temperature Regulator Type 1u

COMMONLY USED RESIDENTIAL BUILDING CODES

CURRENT RATINGS MORE THAN A CABLE

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

SECTION PIPE HANGERS AND SUPPORTS

Detailing of Reinforcment in Concrete Structures

Decree of the Ministry of the Environment on fire safety of ventilation systems

Fire Barrier Duct Wrap 15A

Quality Regulations for Profiles

lindab duct suspension & support system Duct suspensions & Support systems

Installation Manuals Version n. 01 of 14/06/2013

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

Metal Pressfitting Pipe Systems

Partitioning & Ceiling Product Information

Sikaflex Sealant Installation. Sika Corporation

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

SECTION STANDING SEAM METAL ROOFING

This attractive cover system has been designed to complement the Pipe Cover and Skirting Cover product ranges.

Composite Panel Firewall Systems

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Chapter 6 ROOF-CEILING SYSTEMS

Duct Leakage Testing. Ken Helfers, TSI Inc. 2011, TSI Incorporated

ABB Robotics, June IRB 1200 Overview. ABB Group August 21, 2014 Slide 1

Transcription:

HOTCHKISS AIR SUPPLY Heating, Ventilating & Air Movement Equipment F l a t O v a l T u b e a n d F i t t i n g s

Introduction Hotchkiss Flat Oval ductwork offers all the advantages of rectangular ducts with a standard of air tightness associated with spirally wound ducts. The range of Flat Oval sizes is particularly useful where designers have space limitations in ceiling voids or riser applications. It has the additional advantage of fewer site joints and supports compared with rectangular ductwork. Site joints may be sealed with conventional sealants, Hardcast or heat shrink products. The Hotchkiss range of Flat Oval ducts comply fully with the HVCA DW/144 specifications for sheet metal ducts. These ducts are suitable for Low, Medium and High pressure systems and the following tables illustrate: 1. Design Equivalents (ISO R20 Sizes) This table gives the size(s) of Flat Oval duct that will provide the equivalent volume to an ISO R20 standard circular duct diameter. 2. Available Sizes and Sheet Thickness This table illustrates the standard sizes in bold type together with the supplementary sizes in italics and indicates the duct surface area and metal thickness. 3. Flat Oval Ducts Low, Medium Pressure Stiffening Requirements This table illustrates the stiffening provisions for Flat Oval ducts in these pressure ranges. 4. Flat Oval Ducts High Pressure Stiffening Requirements This table illustrates the stiffening provisions for Flat Oval ducts in the high pressure range. 5. Flat Oval Fittings A wide range of matching fittings is available for all sizes of Flat Oval ductwork in all pressure classes. The illustrations indicate the format of the fittings. Important Notes All dimensions given in the tables are nominal and must not be used for the production of matching fittings, supports etc.

Design Equivalents (ISO R20 sizes) Table 1 ISO R20 Series Circular - Flat Oval Design Equivalents Standard Spiral Duct Size Range Depth of Duct - Nominal B mm Diameter mm 76 102 127 152 203 254 305 356 406 457 8 160 320 180 401 200 521 386 224 467 371 2 452 399 280 478 315 638 355 800 610 400 1039 770 582 4 932 742 632 0 1171 902 792 560 1143 955 846 737 630 1626 1196 1006 897 787 710 19 1598 1326 1138 1029 919 800 1727 1539 1270 1161 900 1941 1671 1483 1000 1885 Width of Duct A mm For intermediate design sizes consult our technical department B A L Max Lengths 3000mm up to 478 x 152 30mm up to 1885 x 8

Sizes & Sheet Thicknesses Table 2 Nominal Surface Depth of Duct - Nominal Sheet Area per B mm Thickness Metre Length 76 102 127 152 203 254 305 356 406 457 8 600 1 2 3 mm sq m mm mm mm mm mm mm mm mm mm mm mm mm 0.718 320 0.798 361 345 333 318 0.878 401 386 371 358 0.8 0.958 442 427 411 399 1.037 480 467 452 437 1.117 521 8 493 478 1.197 546 533 518 1.277 559 531 1.436 638 610 582 1.596 719 691 663 632 1.756 800 770 742 714 686 655 1.915 879 851 823 792 765 737 709 678 2.075 960 932 902 874 846 818 787 759 2.238 1039 1011 983 955 925 897 869 841 2.394 1120 1092 1064 1034 1006 978 9 919 900 2.553 1201 1171 1143 1115 1087 1057 1029 1001 2.713 1224 1196 1166 1138 1110 1080 1000 1.0 2.873 1335 1303 1275 1247 1219 1189 1161 3.033 1384 1356 1326 1298 1270 1242 3.192 1466 1435 1407 1379 1351 1321 3.511 1626 1598 1567 1539 1511 1483 3.671 10 3.830 1786 1758 1727 1699 1671 1643 4.1 19 1920 1800 4.310 1969 1941 1913 1885 Width of Duct A mm Note: Standard sizes appear in bold type, supplementary sizes in italics

Low, Medium Pressure Stiffening Requirements Table 3 Tie Rods Depth of Duct - Nominal B mm Not required 1000mm centres 7mm centres 0mm centres 76 102 127 152 203 254 305 356 406 457 8 600 1 2 Width of Duct A mm 320 361 345 333 318 401 386 371 358 442 427 411 399 480 467 452 437 521 8 493 478 546 533 518 559 531 638 610 582 719 691 663 632 800 770 742 714 686 655 879 851 823 792 765 737 709 678 960 932 902 874 846 818 787 759 1039 1011 983 955 925 897 869 841 1120 1092 1064 1034 1006 978 9 919 900 1201 1171 1143 1115 1087 1057 1029 1001 1224 1196 1166 1138 1110 1080 1000 1335 1303 1275 1247 1219 1189 1161 1384 1356 1326 1298 1270 1242 1466 1435 1407 1379 1351 1321 1626 1598 1567 1539 1511 1483 1786 1758 1727 1699 1671 1643 19 1920 1800 1969 1941 1913 1885 10 Note: Standard sizes appear in bold type, supplementary sizes in italics

High Pressure Stiffening Requirements Table 4 Tie Rods Depth of Duct - Nominal B mm Not required 1000mm centres 7mm centres 0mm centres 76 102 127 152 203 254 305 356 406 457 8 600 1 2 0 Width of Duct A mm 320 361 345 333 318 401 386 371 358 442 427 411 399 480 467 452 437 521 8 493 478 546 533 518 559 531 638 610 582 719 691 663 632 800 770 742 714 686 655 879 851 823 792 765 737 709 678 960 932 902 874 846 818 787 759 1039 1011 983 955 925 897 869 841 1120 1092 1064 1034 1006 978 9 919 900 1201 1171 1143 1115 1087 1057 1029 1001 1224 1196 1166 1138 1110 1080 1000 1335 1303 1275 1247 1219 1189 1161 1384 1356 1326 1298 1270 1242 1466 1435 1407 1379 1351 1321 1626 1598 1567 1539 1511 1483 1786 1758 1727 1699 1671 1643 19 1920 1800 1969 1941 1913 1885 10 Note: Standard sizes appear in bold type, supplementary sizes in italics

Connectors, Transitions, End Caps 10 75 Tube Connector Order Codes: RC, DRC End Cap Order Code: CE a x b a x b E E 01 Oval-Oval Concentric Reducer Order Code: T Oval-Oval Offset Reducer Order Code: T D Ø D Ø 02 02 E E 01 Oval-Circular Concentric Transition Order Code: OR Oval-Circular Offset Transition Order Code: OR Note: In the case of offset transition pieces, the purchaser should provide the following additional dimensions. From the point of the air flow entering the fitting: 1. The horizontal centre line offset left or right in millimetres. 2. The vertical centre line offset up or down in millimetres. 3. Tube connectors, single swaged connectors supplied with oval ducts with no tie bars, double swaged connectors supplied with oval ducts with tie bars. 4. E dimensions to suit clients requirements. Price list allows for max length of 900mm.

Hard Bends R=0.5A R=0.5A 90 Five Section Bend 45 & 60 Mitred Elbows Order Code: B90H Three Section Bend Order Code: MEH Order Codes: B45H, B60H Minor angles less than 45 Easy Bends R=B R=B 90 Five Section Bend 45 & 60 Mitred Elbows Order Code: B90E Three Section Bend Order Code: MEE Order Codes: B45E, B60E Minor angles less than 45 Mitred Bends (With Turning Vanes) 90 Mitred Bend Hard Order Code: 90MBH 90 Mitred Bend Easy Order Code: 90MBE

Breeches Pieces, Offsets E E G G R R R=0.5A Breeches Piece Offset-Hard Offset-Easy Note: E dimensions to suit clients individual requirements. Price list allows for max length of 900mm. Prices for longer offsets available on request. Head Office: Heath Mill Road, Wombourne, Wolverhampton, West Midlands WV5 8AP Tel: (01902) 895161 Fax: (01902) 892045 www.hotchkissairsupply.co.uk email: sales@hotchkissairsupply.co.uk 04/09 Every effort is made to ensure that the information contained in Hotchkiss Air Supply s literature is accurate, but no warranty is given in this respect and the Company shall not be liable as a result of any inaccuracy. The Company has a policy of continuous product development and reserves the right to alter, at any time, specifications, without prior notice.