Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES



Similar documents
RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

Diesel Engine Driven Generators Page 1 of 6

Magnum Mobile Generator MMG55 Specifications

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

DIESEL GENERATOR SETS

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

1000 kva POWER MODULE UTILITY SWITCHGEAR C32 ACERT TECHNOLOGY 50 / 60 Hz CONVERTIBLE SOUND ATTENUATED ISO 20 FT. CSC CERTIFIED

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

C18 ACERT Fire Pump Tier bkw/ rpm

C18 Diesel Oilfield Generator Set

Spark-ignited generator set

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

How To Use A Cat Diesel Engine

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Diesel Generating Set

APS100 Rental Generator Set Specification

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

3516 Industrial Engine

Power Generation. Power Control PCL System Generator Set Control

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

Annex-A TECHNICAL SPECIFICATION

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

STANDBY 3200 ekw 4000 kva 50 Hz 1500 rpm Volts

SWITCHGEAR. EGP Switchgear

X G R E N T A L

Marine Generating Sets 3.7 to 50 kva

The kva RAnge

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Thyristor-controlled power supplies and battery chargers

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

How To Control A Power Command Powerplant

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Atlas Copco Generators

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

GTEC transfer switch open transition

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Technical Specification. Generating Set with Waukesha engine burning natural gas

Diesel Generator Set Model DGDK 60 Hz

SECTION LOW VOLTAGE LIGHTING CONTROLS

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Back-UPS Pro 1300/1500 Installation and Operation

FIREDEX Conventional Fire Panels

USER S MANUAL HSC-24A

WHOLESALE DIRECT INC WEST 65TH STREET

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Diesel Generator Set Model DFHC 60 Hz

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

FOXAIR 60/50 ALL MODELS

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Diesel Generator Set Model DFMB 60 Hz

Industrial Generator Set Accessories

Oil and Coolant Circulating Heating System. Model - OCSM

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

, User s Manual

PI734D - Technical Data Sheet

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

PI734B - Technical Data Sheet

EKOS Cart. Instructions for Use

301.7D. Mini Hydraulic Excavator

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Installation and Operation Back-UPS 1250, 1300, 1500

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

SECTION VARIABLE FREQUENCY DRIVES

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Fire Pump Plan Review March 2010

Integrated Power Systems for Data Centers

PowerCommand 3201 digital generator set control

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

PowerWizard 1.0 & 2.0 Control Systems. Technical Manual

*.ppt 11/2/ :48 PM 1

PM734F - Technical Data Sheet Winding 28

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Transcription:

C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES Factory designed, certified prototype tested with torsional analysis. Production tested and delivered in a package that is ready to be connected to your fuel and power lines. Electric Power Design Pro computer sizing available. Supported 100% by your Caterpillar dealer with warranty on parts and labor. Extended warranty available in some areas. The generator set is designed and manufactured in an ISO 9001:2000 compliant facility. Generator set and components meet or exceed the following specifications: BS5000 Part 99, IEC60034-1, VDE0530, NEMA MG1.22, BS4999, BS5514, ISO3046/1, DIN6271, ISO8528, and EGSA101P CATERPILLAR C18 GENERATOR Single bearing, wye-connected, static regulated, brushless generator designed to match the performance and output characteristics of the Caterpillar diesel engine that drives it. CATERPILLAR COOLING SYSTEM Sized compatible to rating with energy efficient fan and core. LINK BOARD ASSEMBLY Set mounted generator multi-voltage adjust plate. Voltage nodes 208V, 240V and 480V Wye configuration. ENVIRONMENTALLY FRIENDLY 110% full spill containment of all onboard fluids. SOUND ATTENUATED CONTAINER For ease of transportation and protection. Meets 75 db(a) at 7m or below per ISO3744 measurement procedure. RELIABLE, FUEL EFFICIENT DIESEL ENGINE The compact, four-stroke-cycle diesel engine combines durability with minimum weight while providing dependability and economy. The fuel system operates on a variety of fuels.

FACTORY INSTALLED STANDARD EQUIPMENT System Standard Equipment EPA approved Tier II C-18 ATAAC Caterpillar diesel engine Air cleaner with service indicator Engine 45-Amp charging alternator Fuel filters - primary and duplex secondary with integral water separator and change-over valve Jacket water heater, fuel cooler, priming pump and pressure gauge Electronic ADEM A4 controls Generator Multi-Voltage, brushless, IE exciter, three-phase with automatic voltage regulator, space heater, 12-lead design, Class H insulation operating at Class F temperature for extended life. 20 ISO high cube container, CSC certified 2-axle 20 ISO container chassis Sound attenuated air intake louver at rear of container with cooling air discharged vertically from roof. 2 lockable personnel doors with panic release, one lockable double door for control access. Bus bar access door, external access load connection bus bars Shore power connection via distribution block Containerized Module Standard lighting 2 AC / 2 DC, one (1) single duplex service receptacle, 2 external break-glass emergency stop push buttons Fuel tank UL listed, double wall, 14hr runtime @ 75% load Sound Attenuated 75 db(a) @ 7m, spill containment 110% of all onboard fluids i.e.: fuel, coolant, and oil Oversized maintenance-free battery, battery rack and 10-Amp battery charger Critical grade internally insulated exhaust silencer Vibration isolators, corrosion resistance hardware and hinges, External drain access to standard fluids (coolant and oil) Standard CAT decals and painted standard CAT power module white. Cooling Standard cooling provides 43 C ambient capability at prime plus 10% overload rating Engine mounted, vertical radiator, vertical air discharge, and exhaust discharge, hand operated fill. Set-mounted control panel with EMCP 3.3 controller Automatic start/stop with cool down timer 2,500A circuit breaker, UL listed, electrically operated Control Panel Meters: kw, kva, kvar, PF, kwh Protection: 27, 59,810, 81U Event log, standard lights display (status and alarms) Auxiliary power connections for jacket water heater, space heater, battery charger 2,500A reconnectable link board for 208/240/480V Wye configuration. Quality Standard genset and package factory tested UL, NEMA, ISO and IEEE standards O&M manuals

CAT C18 GENERATOR Frame Size............................... 7024J Excitation..................................AREP Constructions........... Single Bearing, close coupled Insulation.................................Class H Enclosure..............Drip proof IP22 Alignment................... Pilot shaft Overspeed capability.......125% of rated Voltage regulator...... R448 Voltage regulation....... Less than +/- ½% steady state Wave form................2% deviation Telephone Influence Factor (TIF) Less than 50 Harmonic Distortion (THD).............. Less than 5% CAT C18 DIESEL ENGINE C18, I-6, 4-Stroke-cycle diesel Bore -........................... 145mm (5.71 in) Stroke -.......................... 183 mm (7.2 in) Displacement -................... 18.13 (1106.36 3 ) Compression ratio......................... 14.5:1 Aspiration...................... Air to Air Aftercooled Fuel system................................meui Governor Type........ Caterpillar ADEM Control System Power Rating Prime 60 Hz ekw (kva) 545 (681) Engine and Container Information Engine Model C18 Container Size m (ft) 6 (20) Container Dimensions mm (in) Length 6096 (240.00) mm (in) Width 2438 (96.00) mm (in) Height 2896 (114.00) Fuel Capacity L (Gal) 1620 (428) Operation at 75% Load Hours 14 (approx.) Approximate Weight with Genset and Switchgear Dry Including Container kg (lb) 13608/(30000) (approx.) With Optional Undercarriage kg (lb) 16330/(36000) (approx.)

STANDARD CONTROLS 6 m (20 ft) CONTAINER 480V/60 HZ PRIME POWER OPERATION The generator is set to RUN and the start sequence is initiated. If the engine fails to start after 3 attempts, the start sequence is disabled. STANDBY OPERATION Upon receipt of a standby start signal (provided locally or remotely by the customer via automatic transfer switch), the generator automatically starts, attains rated speed and voltage, and feeds the connected emergency load. Generator circuit breaker is normally closed when in standby mode. The customer must ensure that the load is less than the genset is capable of block loading, and ensure that the load bus is disconnected from a utility source. When signaled to shutdown, the engine is placed in the cool-down mode. At that time, the utility may be reconnected to a load bus. GENERATOR SET EMCP 3.3 LOCAL CONTROL PANEL Generator mounted EMCP 3.3 local control panel Provides MODBUS datalink to engine and generator Convenient service access for Caterpillar service tools (not included) The Caterpillar EMCP 3.3 places fully featured power metering, protective relaying and engine and generator control and monitoring at your fingertips. Integration with the voltage regulator provides enhanced system performance. Ability to view and reset diagnostics in all controls networked on J1939 datalink. Network modules via the control panel, removes the need for a separate service tool for troubleshooting. Fully featured power metering, protective relaying, engine and generator parameter viewing, and expanded AC metering are all integrated into this controller. Fuel level monitoring and control Real-time clock allows for date and time stamping of diagnostics and events. OPERATOR INTERFACE -Graphical display with positive image, transflective LCD, adjustable white backlight/contrast. -Two LED status indicators (1 red, 1 amber). -Three Engine Control Keys and Status Indicators (Run/Auto/Stop). -Lamp Test Key -Alarm Acknowledgement Key. -Display Navigation Keys -Two Shortcut Keys: Engine Operating Parameters and Generator Operating Parameters. PROGRAMMING AND DIAGNOSTICS Includes field programmable set-points for engine control and monitoring variables and self diagnosis of the EMCP-3 system component and wiring failures. ALARM MODULE Flashing LED warnings for: low coolant temperature, high coolant temperature (pre-alarm), low oil pressure (pre-alarm), engine control switch not in automatic and low DC voltage. Includes an alarm horn and acknowledge pushbutton. ENGINE CONTROL KEYS RUN Key, AUTO Key and STOP Key with LED Indicators. CIRCUIT BREAKER CONTROL SWITCH Heavy duty, three (3) position spring return to center with momentary trip and close position and slip contacts for automatic closing. Pull to lock feature in trip position.

ALARM ACKNOWLEDGE/SILENCE KEY Pressing the Alarm Acknowledge/Silence Key will silence the horn and cause any yellow or red alarm/shutdown lights to turn off or become solid depending on the active status of the alarms. LAMP TEST KEY Pressing and holding the Lamp Test Key will cause all LEDs and pixels on the LCD screen to turn on solid until it is released. EMERGENCY STOP PUSHBUTTON Mushroom head, twist to reset, causes engine shutdown and tripping of the generator circuit breaker. Prevents engine starting when depressed. SCROLL KEYS Scroll Up Key Used to navigate up through menus or monitoring screens and for set point entry. Scroll Down Key Used to navigate up through menus or monitoring screens and for set point entry. Scroll Right Key Used for set point adjustment. Scroll Left Key Used for set point adjustment. ENTER/ESCAPE KEYS Enter Key Used during menu navigation to select menu items and during set point programming to save changes. Escape Key - Used during menu navigation to move up through menu items and during set point programming to cancel changes. CIRCUIT BREAKER 2500A, 3 pole, UL Listed, electrically operated, insulated case circuit breaker with solid state trip unit for overload (time overcurrent) and fault (instantaneous) overcurrent protection. DC shunt trip coil activated on any monitored engine or electrical fault. ELECTRONIC GOVERNOR Includes speed adjust potentiometer and idle/rated switch. VOLTAGE REGULATION CIRCUITRY Standard Caterpillar generator mounted automatic voltage regulator with voltage adjust rheostat. CURRENT TRANSFORMERS CT s rated 2500:5 with secondaries wired to shorting terminal strips. BUS BARS Three phase, plus fully rated neutral, bus bars are tin-plated copper with NEMA standard hole pattern for connection of customer load cables and generator cables. Bus bars are sized for full load capacity of the generator set at 0.8 power factor. Also includes ground bus, tin-plated copper, for connection to the generator frame ground and field ground cable. LINKBOARD ASSEMBLY Set mounted generator multi-voltage adjust plate. Voltage nodes 208V, 240Vand 480V-wye configuration. Link board access via door in sidewall of container. AC DISTRIBUTION / SHORE POWER CONNECTIONS Transformer distributes utility voltage to the distribution board providing 120 VAC for all module accessories. Shore power cable connections via cable gland in the side of the container, hardwired to terminal block in distribution board. One (1) 120 VAC shore power connection for jacket water heaters, generator space heater and battery charger. Genset control panel includes fault protection and relays to deenergize jacket water heaters and generator space heater when the engine is running.

LIGHTING 2 internal DC lights with a timer installed at each personnel door. 2 internal AC lights with On/Off switch at each personnel door. 1 single duplex service receptacle. BATTERY CHARGER 24 VDC/10A battery charger with float/equalize modes and charging ammeter. CUSTOMER MONITORING OUTPUTS Form C contact outputs (x2) for customer monitoring, configurable to indicate any two of the following conditions: circuit breaker status, engine running, summary alarm, summary shutdown, and controls not in automatic ENCLOSURE DISTRIBUTION PANEL NEMA 1 for indoor use Information contained in this publication may be considered confidential. Discretion is recommended when distributing. Materials and specifications are subject to change without notice. CAT, CATERPILLAR, their respective logos, "Caterpillar Yellow," and the POWER EDGE trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. 2008 Caterpillar All rights reserved