7 Lighting Technology



Similar documents
Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices SolConeX 16 A Series 8570

Series 8146/5-V37 and Series 8150/5-V37

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

LUT Luminescence scanners: Seeing what no-one else can

Linear Luminaire with LED Series EXLUX 6402/2

Emergency Light Fittings

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

A good connection. International approvals.

Wolflite Safety Handlamp H-251E

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Terminal Boxes Series 8146

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

ACS-30-EU-EMDR-10-MOD

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

Control and Distribution Boxes made of Stainless Steel Series 8150

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

W150: Miniature photoelectric switch series with completely integrated electronics

Thermal-Magnetic Circuit Breaker M1-..

9 Control Equipment. Control Button Series 8082

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

HERZ-Thermal Actuators

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

BroadBand PowerShield. User Manual

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

Infrarot-Bewegungsmelder IP44

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

2.12. page Products for Explosion hazardous Environment

Section D..General Auto Electrical Corporation

Flameproof Audible Signal 115 db (A) Series YA90

Battery charger. Art.no Model CB5-5L-BS1 ENGLISH SVENSKA NORSK SUOMI. Ver Original instructions

Operating Instructions

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Electronic Pressure Switch EDS 3000

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

DALI RC BASIC SO. Control unit Operating instructions

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Drayton Digistat +2RF/+3RF

Pluggable interface relays CR-P Pcb relays

is then retained absolutely without interruption.

3x cinch/s-video socket Order no.: xx. USB/3.5 mm audio socket Order no.: xx. VGA socket Order no.: xx

Cable Plug acc. to DIN EN , Form A

Cross-beam scanning system to detect slim objects. 100 mm in

Redundancy Module QUINT-DIODE/40

type V46, solenoid or pneumatic operated

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

5SV Residual Current Protective Devices

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

TT TOYS TOYS - OWNER S MANUAL. We are delighted that you have decided to purchase this TT Toys Toys children s car.

RY2 miniature industrial relays

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Floodlight Range Installation Guide

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

3/2-way pneumatic cartridge solenoid valve

Air damper actuators

Thyristor-controlled power supplies and battery chargers

Control- and feedback head for integrated mounting on Robolux valves Type 2036

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Product and functional description

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Digital input modules

Video surveillance camera Installation Guide

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

8146/5 Series Breaker Panelboards

The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

38 Series - Relay interface modules A

9Section. contents. TE Controls. Safety Relays 9.2. Signal Towers 9.5. Hazardous Area Equipment 9.6 Safety Products. Pilz Omron...9.

Operating Instructions

Emergency lighting units EM powerled

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

How To Read A Pipe From A Sensor

EKOS Cart. Instructions for Use

UM-X Field display for continous level sensors

Transcription:

7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light intensity 15.000 cd after 4 hours use NiCd battery, gas-tight Charging unit available for stationary installation installation into vehicles Series HSL145 Industrial design without explosion protection 09901E00 The electronics of portable lamps Series 6145 and Series L145 are resistant to electromagnetic fields, enabling the lamps to be used with radio equipment. Zones 1 & 2, Industrial Design 7/1

7 Selection Table Version Description Order number Weight Explosion protected portable lamp with integrated monitoring electronics 6145/1 1.900 with integrated charging unit and monitoring electronics 6145/2 2.500 kg 02911E00 Charging unit* (N-Ex) Industrial type portable lamps (N-Ex) 230 V, without emergency light 6145/91* 2.080 230 V, with emergency light 6145/92* 2.090 12 V / 24 V, without emergency light ; for installation into vehicles 6145/93* 1.800 with integrated monitoring electronics L145/1 1.900 without electronics L145/3 1.600 02910E00 Charging unit* (N-Ex) 230 V, without emergency light L145/91* 2.000 230 V, with emergency light L145/92* 1.800 12 V / 24 V, without emergency light ; for installation into vehicles 230 V, without emergency light (Simple version, halve charging current) * Attention: Not for use in hazardous areas. Battery charging outside of hazardous area. L145/93* 1.000 L145/96* 2.000 7/2

7 Technical Data Version 6145/1 (explosion protected) 6145/2 (explosion protected) L145/1 (N-Ex) Explosion protection E II 2 G EEx e ib IIC T4 Not explosion protected Certificates PTB 03 ATEX 2150 Certificate for motor vehicles e1*72/245*95/54*3406*00 e1*72/245*95/54*3406*00 Enclosure material Moulded material; non-abrasive, cold shock resistant; antistatic Type of protection IP54 IP54 Functions Head tilting forward: 20 back: 90 Accessories Continuous or flashing light available with main or economy lamp Diffusing lens; coloured lenses; warning light; all fitted into slots on lamp head L145/3 (N-Ex) Moulded material; non-abrasive, cold shock resistant; antistatic Continuous or flashing light available with main or economy lamp forward: 20 back: 90 only continuous light available Diffusing lens; coloured lenses; warning light; all fitted into slots on lamp head Range approx. 100 m bei 1 Lux approx. 100 m bei 1 Lux Light aperture approx. 100 x 100 mm approx. 100 x 100 mm Light intensity approx. 15 000 cd to 4 h approx. 15 000 cd to 4 h Lamps Main lamp 4.8 V / 4 W (BA15d) 4.8 V / 4 W (BA15d) Economy lamp 4.8 V / 1.5 W (BA9s) 4.8 V / 8 W (BA15d) 4.8 V / 8 W (BA15d) Rare-gas Luminance time per charge Main lamp Continuous light approx. 6 h... 8 h approx. 6 h... 7 h approx. 3 h Flashing light approx. 23 h approx. 20 h approx. 9 h Economy lamp Elektronics Continuous light approx. 22 h approx. 19 h approx. 22 h Flashing light approx. 80 h approx. 69 h approx. 80 h Charge state display Deep discharge protection Open circuit monitor Battery The battery charge level is indicated by 2 LEDs When battery voltage is low, automatic switchover to economy lampresidual lighted time 10 min... 20 min If main lamp is faulty, switchover to economy lamp The battery charge level is indicated by 2 LEDs When battery voltage is low, automatic switchover to economy lampresidual lighted time 10 min... 20 min If main lamp is faulty, switchover to economy lamp Type NiCd-battery gas-tight NiCd-battery gas-tight Self - discharge Battery charge level > 75 % > 25 % < 25 % LEDs LED 1: LED 2: Ambient temperature at 20 C at 40 C Discharge 50% after 6 weeks 50% after 2 weeks Rated voltage 4.8 V 4.8 V Battery charge level > 75 % > 25 % < 25 % LEDs LED 1: LED 2: Ambient temperature at 20 C at 40 C If main lamp is faulty, switchover to economy lamp Discharge 50% after 6 weeks 50% after 2 weeks 7/3

7 Technical Data Charging unit Version 6145/92 L145/92 6145/91 L145/91 L145/96 6145/93 L145/93 6145/2 Application Housing installation, with emergency light installation, without emergency light Attention: Not for use in hazardous areas. Battery charging outside of hazardous area. Moulded material, black, acid and caustic resistant, installation, without emergency light (halve charging current) Attention: Not for use in hazardous areas. Battery charging outside of hazardous area. Moulded material, black, acid and caustic resistant, for installation into vehicles without emergency light integrated into light fitting Charging only outside hazardous area Moulded material, black, acid and caustic resistant, Main cable Length: 2 m; Europlug Length: 2 m Length: 2 m; Europlug and coupler Function Charging starts when lamp is fitted into charger LED charge no Emergency light acc. to VDE 0108; if power supply is switched off, lamp fitted in charging unit becomes effective automatically Rated voltage 50 Hz / 60 Hz LED charge no Charging starts when lamp is fitted into charger LED charge Charging starts when main cable is plugged without without possible, together with 9145/92 50 Hz / 60 Hz 12 V / 24 V, DC (selectable) 50 Hz / 60 Hz Protection class II (all - insulated) II (all - insulated) III (Extra-low voltage) II (all - insulated) Charging time 230 V AC: 14 h 230 V AC: 14 h 12 V DC: 14 h; 24 V DC: 25 h Charging current Protection category Installation 230 V AC: 14 h Constant-current Constant-current Constant-current Constantcurrent 230 V AC: 700 ma 230 V AC: 700 ma 230 V AC: 350 ma IOI Interference suppression acc. to VDE 0875 0.51 Ah/day (Charge 1 / 2h at 700 ma, 16 h interval) free installation or wall mounting possible 12 V DC: 700 ma; 24 V DC: 400 ma 230 V AC: 700 ma 7/4

7 Accessories and Spare Parts Designation Illustration Description Order number Weight Auxiliary lens Warning light hood 05619E00 granulated; fits into slots on lamp head clear 107226 0.020 red 107227 0.030 green 107230 0.030 blue 107228 0.100 orange 107229 0.100 fits into slots on lamp head; colour: orange deflect light by 90, for all-round illumination, for use as a warning light where there are obstacles kg 120209 0.093 05618E00 Incandescent lamps Power saving lamp: 4.8 V / 1.5 W BA9s 120221 0.035 Battery 1) Main cable 05623E00 05624E00 05613E00 Main lamp: 4.8 V / 4 W BA15d 120229 0.030 Main lamp: 4.8 V / 8 W BA15d 120235 0.026 Main lamp: 4.8 V / 8 W BA15d (Rare-gas) 120237 0.026 1) with screw and spring terminals NiCd, gas-tight (explosion protected) 120148 0.880 NiCd, gas-tight (N-Ex) 120142 0.945 NiCd, gas-tight with charging unit for 6145/2 120153 0.800 for 6145/2 105504 0.080 05880E00 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 04805E00 04806E00 04811E00 Portable lamp 6145, L145 Charging unit for portable lamp 6145, L145; not useable in hazardous area Wall mounting of charging unit We reserve the right to make alterations to the technical data, weights, dimensions, designs and products available without notice. The illustrations cannot be considered binding. 7/5