20,000 Barrel Per Day Crude Oil Refinery



Similar documents
Introduction to Process Engineering Economics. based on size of major equipment items allow to decide whether to invest in a detailed study

Refinery Equipment of Texas. Mini - Refinery Feasibility Overview

TABLE OF CONTENT

Design Guidelines for Using Distillation Simulation Software in the Field

Oil Refinery Processes A Brief Overview

10% or 500,000 gallons/year of Crude Glycerine. Shutdown: 2009 B100 BioDiesel or Crude Glycerine Soybean Oil or Animal Tallow, Methanol

Design Procedure. Step 2: The simulation is performed next. Usually the column is not difficult to converge, as the liquid reflux ratio is large.

TITLE PAGE: Feasibility Study for a Petroleum Refinery for The Jicarilla Apache Tribe.

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Gas Detection for Refining. HA University

Air Eliminators and Combination Air Eliminators Strainers

Vacuum ejector system design, operation and performance

TABLE OF CONTENT

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Unsteady State Relief Valve Evaluation. External Pool Fire Scenario

Some Criteria for Choosing a Steam Boiler for a Microbrewery

CRG CONSERVE RESOURCES GROUP ECO ENVIRONMENTAL ENGINEERING TECHNOLOGIES. NEW State of the Art. Advanced OIL REFINERY TECHNOLOGY & PROCESSES

Factory owners must ensure the boiler is:

GUIDANCE FOR DEVELOPMENT OF SPILL AND SLUG PREVENTION CONTROL PLANS AND FACILITIES FOR THE CITY OF ATTLEBORO SEWER USERS

TABLE OF CONTENT

Suncor Denver Refinery Overview

ASimple Guide to Oil Refining

FLEXICOKING technology for upgrading heavy oil and utilization of by-products

WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )

Subject: Technology Collaboration for Fired Heaters (FH)

Refining of Crude Oil - Process

No. Name Description Main input Data Main Output Data. cooling duty, process in/out temperature, inlet air temperature

5.2. Vaporizers - Types and Usage

How To Make A High Co 2 Gas Blend

ECONOMICAL OPTIONS FOR RECOVERING NGL / LPG AT LNG RECEIVING TERMINALS

Neutralization of Spent Caustic from LPG Plant at Preem AB Göteborg

Course available 24/7 for up to six months from the date of purchase or until completion

Emergency Isolation Valves at Pump Suction: Application for Flammable Liquids

Upgrading of Heavy Oils with FLEXICOKING. ExxonMobil Research & Engineering Company Tim Hilbert

Saudi Aramco Project Development

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

C. starting positive displacement pumps with the discharge valve closed.

12 November 2008 *** I:\CIRC\MEPC\01\642.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

HOW DOES A NUCLEAR POWER PLANT WORK?

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Sustained growth in the demand

Residential Heating Oil Prices: What Consumers Should know

Maximize Conversion and Flexibility

The Single Absorption Scrubbing Sulfuric Acid Process

Boiler & Pressure Vessel Inspection discrepancies and failures

Heat Integration Complicates Heat Pump Troubleshooting

The. Brendan P. Sheehan, Honeywell Process Solutions, USA, and Xin Zhu, UOP, a Honeywell Company, USA, explore energy optimisation in plant processes.

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

NFPA31FuelOilPiping 1 Revised

Design Guidelines for Chemical Treatments in Distillation Columns

Boiler Blowdown. Boiler Blowdown Benefits. Best Operating Practices for Boiler Blowdown

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.

steam vacuum refrigeration old concept / modern application

Facility Operations Physical Safety Guidance Document

Routinely surveying tower overhead vacuum systems can

Laundry Hot Water Systems

TOPIC: KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?

Coker Furnace On-Line Spalling

How To Make A Mine Guard Fosil Process

05 Heat Transfer & its Applications

Open Cycle Refrigeration System

Petroleum refining water/wastewater use and management

Sulphur in Nigerian Diesel

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

REQUEST FOR QUOTATIONS

Application of Simulation Models in Operations A Success Story

SIOUX HYBRID WATER HEATER

Dehydration. Dehydration UNIT. operations. bioprocess plants

EJECTOR AIR REMOVAL SYSTEMS ENGINEERING DATA BULLETIN # PVS ARS PAGE 1 OF 5

5.2 Transportation And Marketing Of Petroleum Liquids General

Balance of Fuel Cell Power Plant (BOP)

AM Cost Effective Solutions for Reduction of Benzene in Gasoline

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

Mini Oil Refinery Review. Rifka Aisyah

Fact Sheet Technology. Bergius-Pier Process (1)

Thermal Coupling Of Cooling and Heating Systems

COMPLETE MANUFACTURING FACILITY

TRAINING, EXAMINATION AND CERTIFICATION

TABLE OF CONTENT

Guidelines for Preparing for a Temporary Steam Plant

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineering solutions.

Mechanical Engineering Technician- Plant Technician

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

Heating Water by Direct Steam Injection

Overview of Waste Heat Recovery for Power and Heat

Gas Marketplace Work? July 9-13, 2007

HEAT RECOVERY FROM CHILLED WATER SYSTEMS. Applications for Heat Reclaim Chillers

IVISIONS STEAM PLANT DIVISIONS TOTAL TURNKEY SOLUTIONS. INDUSTRIAL BOILER & MECHANICAL

CITY OF LOS ANGELES PERSONNEL DEPARTMENT CAREER OPPORTUNITIES FOR MECHANICAL HELPER

How To Understand Evaporator

BHS CANDLE FILTER APPLICATIONS FOR CLARIFICATION / RECOVERY OF SOLIDS FROM CHEMICAL SLURRIES

4.1 Dry Cleaning General 1,2

Originators of the Flexible Water Tube design

TABLE OF CONTENT

FLASH TANK ECONOMIZER PRODUCT GUIDE

Opportunities for optimization of refineries using. Thermal Conversion technologies

Transcription:

20,000 Barrel Per Day Crude Oil Refinery (For Sale) AT THE EXCEPTIONAL PRICE OF $39,500,000.00 PRICE INCLUDES SHIPPING AND INSTALLATION Includes 2- TEN T B/D DISTILLILATION UNITS (SELLER NEEDS TO SELL TO MAKE ROOM FOR NEW REFINERY) The details of the referenced refinery are as follows 20,000 bpd diesel refinery for sale. Total: $39.5 million C&F Nigerian Port (subject to prior sale) The price includes 1. Refurbishment and 2. Dismantlement. The refinery is designed to produce the majority of product as diesel fuel. Plant mainly produced diesel, depending on API, can also make a % of naphtha and kerosene. PLANT INCLUDES TWO SEPARATE 10,000 BPD ATMOSPHERIC UNITS, AND ONE 600 BPD VACUUM USED AS A REFLUX UNIT. (INVENTORY ATTACHED) NOTE. Two (2) 10,000-12,500 bbl per day each Crude distillation Units. One tower is moly. Manufactured by Horton and Inclusive of the following:

Short List: Inventory 5 crude oil process heaters 18 crude and transfer pumps heat exchangers 2 distillation towers - 10,000 bpd each 1 vacuum unit - 600 bpd capacity - used as a reflux unit 3 stripping towers Associated utilities lab equipment 2 boilers complete spare parts and controls Crude Heaters manufactured by Eclipse with burner systems complete with piping, wiring controls, gas or fuel fired. Inventory attached on Description and price document. HISTORY: Started in 1986 with a small 600 bpd vacuum unit. In 1989 the owners needed to expand, and installed the first 10,000 bpd distillation unit to produce diesel, kerosene, and naphtha. At this time the vacuum unit was converted to a reflux unit. A second 10,000 bpd distillation unit was purchased and in the process of being added when the refinery shut down. All parts are included for this second unit. OPTION: FOR LESS AMOUNT CAN SELL EVERYTHING BUT THE SECOND 10,000 B/D DIS TILLATION UNIT. The Refinery was shut down in 1992 due to low prices and gradual reduction in demand for diesel. Periodically the unit is turned on to run fluids through it. This is a fully operational distillation unit and is always pickled in diesel. Export packaging, turnkey and project management services available on a separate contract agreement. Turnkey Estimate does not include the purchase price of refinery or shipment. Final Turnkey agreement Subject to feasibility study. THE PRICE ABOVE INCLUDES DISMANTLEMENT-REFURBISHMENT AS NEEDED. SEE REFURBISH LIST. The services provided on the 20 000 bpd unit Dismantling/refurb/export packaging supervision / Technical and engineering consulting Site preparation supervision / re erection and start up supervision The refinery is designed to produce the majority of product as diesel fuel Mid 80's vintage Heater -

Atmospheric tower with 27 trays - Re-heater reflux tower with 17 trays - Coolers Controls with spare parts Various pumps and motors to support system Cooling tower - manufactured by Baltimore Mead The equipment is maintained by the owner and is in good condition. All vessels are filled with diesel. Electrical system is 60 Hz. Will be converted to 50 hz cycle if required. All heaters and towers have ASME stamps Spare parts Controls: pneumatic This is a fully operational distillation unit and is always pickled in diesel. EQUIPMENT INVENTORY LIST This is a list of the major items but not to be limited to the equipment sold: LOTS OF SPARE PARTS 1. Crude Atmospheric Distillation Two (2) 10,000-12,500 bbl per day each Crude distillation Unit. One tower is moly. Manufactured by Horton and Inclusive of the following: H-101 A & B Crude Heaters manufactured by Eclipse with burner systems complete with complete with piping, wiring controls, gas or fuel fired. T-101 Crude Distillation Tower complete with 27 trays. T-102 #2 fuel oil stripper column tray T-103 Kerosene stripper, Consolidated Fabricators T-104 Naptha Stabilizer column V-101 Crude Oil Overhead Accumulator, V-102 Desalter water drum, Fabricators V-103 Desalter V-104 Column overhead Accumulator VV-106 Compressor Suction Drum V-109 & 114 Fuel Gas KO Drum, complete with compressor discharge

V-113 Fuel Day Tank V-125 Atmosphere Gas Oil Stripper V-131 Pressure Vessel, wash oil surge drum, G-101 Vent Gas Compressor, E-101, Exchanger, 16 tube length, ¾ tube size E-102A & B 2 similar exchangers for service to overhead vapor crude E-103 Same, kerosene crude E-107ABCD 5 exchangers, E-108 A & B 2 Crude column overhead condensers, E-111 #2 Fuel Oil cooler E-112ABCD 4 Reduced Crude Coolers, E-113 Desalter Brine Water Exchanger E-114ABC 3 Stabilizers Feed Exchangers E-115 A&B 2 same, Stabilizer Feed Pre-Heater E-116 Stabilizer overhead condenser E-118 Heat Exchanger LPG Vaporizer E-119, 121 2 Air-cooled Exchangers E-136 AGO Cooler, P-101 A & B 2 Pumps, motors to include wiring, piping and controls P-101C Pump, crude charge,

P-102 A & B 2 Ingersall Rand pumps, P103 A & B 2 same, P-105 A & B 2 Same, P-104 A & B 2 Goulds pumps P-107 A & B 2 Pumps P-108 A & B 2 Same, P-109 A & B Same P-110, 111A & B 3 Same Model P-112 A & B 2 Ingersall Rand pumps, P-114 A & B Same P-123 A & B 2. Crude Vacuum Reflux Unit One Hundred Thousand (100,000) tonnes per year capacity Inclusive of: H-102 Vertical cylindrical vacuum heater comprising vacuum heater, air preheat system, burners, platforms, piping and controls. V-103 Desalter, designed to 275 PSIG & 350 F V-123 Vacuum tower V-125 AGO stripper, V-126 90 PSIG steam drum E-135 A & B 2 desalter make up water/desalter brine exchangers, E-139 Condenser E-140 Condenser E-142

Condenser M-346 A & B Cooling towers, vacuum tower system cooling water E-129 HVGO stream generator E-130 Same, vacuum tower bottom E-131 AGO crude exchanger E-133 LVGO product cooler E-134 HVGO product cooler E-136 AGO cooler V-127 Barometric sump V-128 Wash oil surge drum, E-125 A & B 2 LVGO crude exchangers E-126 A & B 2 HVGO product crude exchangers E-128 A & B & C Vacuum tower bottoms, crude exchangers P-125 A & B 2 injector coolant pumps, 40 PSIG, 110 F, 88 ft Head, centrifugal P-127 A & B 2 Pumps, vacuum unit bottoms P-129 A & B 2 wash oil to vacuum tower pumps P-130 A & B 2 HVGO product pumps, P-131 A & B 2 LVGO product pumps P-133 A & B 2 vacuum ejector coolant pumps P-134 A & B 2 barometric water pumps

P-135 A & B 2 barometric slop oil pumps, same model P-143 A & B Pumps, Milton Roy P-262 A & B 2 Pumps, Vacuum cooling tower water, Goulds,