Installation/ Operation Maintenance



Similar documents
General Information... 2

PNEUMATIC CONTROLS Selection and Description

Powers Controls TH 192 S Single Temperature Room Thermostat

RC 195 Multiple Input Receiver-Controller

T-4000 Series Room Thermostat Adjusting Instructions*

Installation Manual. TITUS I, II, and IIA Pneumatic Controls Installation, Operation, and Maintenance Manual. (See Figure 3) (Label, See Figure 3)

KRUEGER Single-Duct and Retro Fit Terminal Units

POWERS CONTROL RC 195 Single Input Receiver-Controller

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

GENERAL PRODUCT OVERVIEW

REGULATORS 175/153 Series

Model 43AP Pneumatic Controller, Style B

Product/Technical Bulletin

PIEZOMETER AIRFLOW MEASURING RING

T-4000 Series Pneumatic Room Thermostats

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

PNEUMATIC CONTROLS Dual Duct Sequence Descriptions

Fan-Powered Parallel

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

POWERS Controls No. 4 Pneumatic Damper Actuator

vav retrofit terminals

HERZ-Thermal Actuators

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

PRODUCT PROFILE FEATURES

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Baumann Flexsleev Sanitary Control Valve

Commercial Gas Cooking Thermostats

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Sanitary Type Electronic Flow Switches

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

! WARNING. Before using product, read and understand instructions.

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

PRESSURE REDUCING CONTROL VALVE


TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Brueninghaus Hydromatik. Variable Displacement Pump A11VO RE / for open circuits

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

REAL OPERATING COST SAVINGS FROM RETRO- COMMISSIONING OPPORTUNITIES FOR SAVINGS IN ACADEMIC MEDICAL CENTERS

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Data sheet Thermostatic sensors type RA 2000

Centrifugal Fans and Pumps are sized to meet the maximum

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Frequently Asked Questions

VAD. Variable Area Desuperheaters

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D

DOUBLE SEAT BRONZE BODY HIGH CAPACITY

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

Installing a Probe. Typical Installation

Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters

Elektromotoren und Gerätebau Barleben GmbH

Adjustable room thermostat for heating only or cooling only systems

Radiant Temperature Sensor TY7321

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Stainless Steel Single and Dual Circulation Kits

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Section 5: Machine Overview

Example. Fluid Power. Circuits

Why and How we Use Capacity Control

Chilled Water Fan Coil Unit

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Exhaust Calculation Booklet

How To Control Humidity With A Humidifier

Demand Based Static Pressure Reset Control for Laboratories

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

Fisher 657 and 667 Diaphragm Actuators

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Float and Thermostatic Traps Series H, C and X

Oil and Coolant Circulating Heating System. Model - OCSM

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Fundamentals of HVAC Control Systems

TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9)

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

T and T Single Input Receiver-Controllers Installation and Calibration

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

HVAC CONTROLS INTRODUCTION

TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work

Submersion/Insertion Toroidal Sensor

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

SELECTION, APPLICATION & MAINTENANCE

SIMPLIFIED VALVE CIRCUIT GUIDE

Easy Tool Retracting System CMC-SR2159ER36

UNIFIED FACILITIES GUIDE SPECIFICATIONS

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

SELECTION, APPLICATION AND MAINTENANCE

Chilled Water HVAC Systems

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Air Conditioning Clinic

Transcription:

Installation/ Operation aintenance VariTrane Pneumatic Controls arch 02

Thermostat Thermostat election and Location In general, both one- and two-pipe thermostats have a gain of 2.5 psi per degree Fahrenheit, unless special thermostats are used that provide a different gain. The major difference between them is that a one-pipe thermostat is considered a lowcapacity thermostat and a two-pipe thermostat is considered a highcapacity thermostat. When selecting between one-pipe and two-pipe thermostats consider the following: Use one-pipe thermostat when: tubing runs are less than 50 feet from thermostat to controller. a single thermostat will control no more than three controllers. slower response is desired from the thermostat. Use two-pipe thermostat when: tubing runs exceed 50 feet from thermostat to controller. a single thermostat will control four or more controllers. high capacity air is required due to restrictions in the air line. Thermostat Piping The two-pipe thermostat (Figure 1) includes a restrictor (internally). Attach supply air line and output pressure (branch) line to the thermostat. The one-pipe thermostat (Figure 2) requires an external restrictor tee. Connect main air supply to restricted leg of restrictor tee. Connect branch line from restrictor tee to the thermostat. Figure 1 Two-Pipe Remote Thermostat (Reverse-Acting) Figure 2 Typical One-Pipe Thermostat (Reverse-Acting) Tee Fan P.E. witch 1 (N.O.) 9 PI (62.06 kpa) Tee 15 (103.4) (137.9) Restrictor Tee (137.9) Restricted Leg Two-Pipe Remote-ounted T-tat (Reverse-Acting) One-Pipe Remote-ounted T-tat (Reverse-Acting) 2

Thermostat pecifications TP970 eries Pneumatic T-stats aximum afe Air Pressure: 25psi (172 kpa) aximum afe Air Temperature: 150 F (66 C) Throttling Range: 2 10 F (1 5 C) Gain: 2.5 psi/ F Adjustable Operation Pneumatic thermostats modulate output air pressure in response to room air temperature. Pneumatic thermostats fall into two categories: directacting or reverse-acting. This section describes how thermostat output pressure responds to changes in room temperature. Figure 3 graphically illustrates the relationship between room temperature and output pressure of a direct-acting thermostat. The graph in Figure 3 shows that as the room temperature increases, so does the output pressure of the thermostat. Figure 3 Direct-Acting Thermostat Response Output Pressure Figure 4 illustrates the pressure/ temperature characteristics for a reverse-acting thermostat. As room temperature increases, the thermostat output pressure decreases. Figure 4 Reverse-Acting Thermostat Response Output Pressure Input Temperature A thermostat in proper working order will be able to output a pressure ranging from approximately.5 psi to supply air pressure depending on distance from indicated setpoint. Input Temperature 3

Reversing Relay Installation and Operation The reversing relay is a proportional, non-bleeding device for use in pneumatic control systems where a proportional signal from a controlling device must be reversed (see Figure 5). The most common use of the reversing relay is to change the action of a pneumatic thermostat. Figure 5 Pneumatic Reversing Relay Trane Part No. RLY-755 Figure 6 Reversing Relay Connections (137.9) Output Branch B Reversing Relay 9 PI In (62.06 kpa) 9 PI Out (62.06 kpa) Input Branch The reversing relay requires three piping connections: main/supply air, input signal air, and output branch air (see Figure 6). The branch line pressure decreases in direct proportion to an increase in the input signal pressure and vice-versa. The input signal is also amplified, thereby minimizing any pneumatic line transmission lag (see Figure 7). Input pressure to the relay and output pressure to the PR should always add up to a constant, which is usually set between 16 and 25 psi. For example, with a constant of 18, six-pound input signal will result in a 12 pound branch signal. A bias adjustment screw is provided to retard or advance the out signal. Figure 7 Reversing Relay Characteristics Output Branch Pressure Inc. 15 12 3 3 6 15 Inc. Input Pressure ignal 4

Reversing Relay Calibration By using the bias adjustment on the relay, the factory-set 8.0 9.0 crossover can be changed. To recalibrate, the relay should be connected as illustrated in Figure 8. Figure 8 Recalibrating Reversing Relay Gage 1 Pressure Regulator C 3 Bias Adjustment crew If the new desired cross-over pressure is 11.0 psi, this must be applied to port #3 by adjusting the pressure regulator. The bias adjustment is then turned until 11.0 psi is obtained on the output gage. Turning the bias adjustment CW increases the output; CCW decreases it. This 11.0 psi cross-over would yield the following operational chart: Chart New Cross-over pressure Input: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Output: 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 pecifications aximum Pressure: 30 psig Connections: 3/16" (4.& mm) nipples for ¼" (6.4 mm) OD polyethylene tubing Air Consumption: 0.5 CFH (.236 L/) @ psig aterial: AB Weight: 3 ½ oz Ambient Limits: +40 F/+1 F operating (+4 C/+49 C) ounting: In-line via air connections Factory ettings: 9 psig in./9 psig out and 8 psig in./8 psig out Bias Adjustment: +/-15 psi 5

odel 3011 Pneumatic Volume Regulator odel 3011 The model 3011 Pneumatic Volume Regulator (PVR) is capable of operating with normally-open or normally-closed air valves and can operate with either direct-acting (DA) or reverse-acting (RA) thermostats. Installation 1. Attach bracket either vertically or horizontally to the illustration surface. Horizontal is preferred, vertical is acceptable, any other position is not acceptable (see Figure 9). 2. Insert controller into its bracket. Controller may be face up, face down, face left, or face right. The controller LO and HI stat delta P must be calibrated in the same position that it is mounted. Figure 9 Acceptable Installation Positions Connections Figure 10 illustrates a typical piping diagram of a normally-open or normallyclosed unit. Figure 10 Typical Piping Diagram of Normally-Open or Normally-Closed Unit Normally-Open Unit or Normally-Closed Unit LO HI H Volume Regulator T Restrictor Tee One-Pipe Remote-Installed T-tat Actuator B LO TAT P NC I N C CR I N CR CR HI TAT P DAPER REET PAN Restricted Leg G Airflow ensor electing Direct- or Reverse-Acting Thermostat (3011) The model 3011 PVR must be calibrated to operate with either a direct-acting or reverse-acting thermostat. The control must also be changed when used with a normally-open or normally-closed air valve. 6

NC R odel 3011 Pneumatic Volume Regulator Use the following procedure to set-up the PVR: 1. elect damper action (NO or NC). Loosen damper selection switch screw and align to either the NO or NC pointer with damper pointer and tighten screw. 2. Now determine the type of thermostat that will be used. If a direct-acting thermostat is used, the reset start pressure is typically 8 psi. If a reverse-acting thermostat is used, the reset start pressure is typically 3 psi (see Figure 11). 3. With an accurate gage (0-10 psi) connected to port G, regulate the thermostat pressure to port T to desired start point pressure. 4. Adjust reset start to indicate 0 psi on port G and continuing adjusting to indicate a pressure slightly higher than 0 psi, (i.e., 0.1 psi). Figure 11 Adjusting Reset tart Adjust to obtain 0 0.1 psi at port G Connect Hand Pump Input desired LO stat pressure at t-stat port B REET TART LO TAT P 0 psi Handpump NO I N C R I N C R HI TAT P psi DAPER REET PAN 0 10 Connect 0 10 psi Gage G Factory-set at 5 psi Adjustable (0 10 psi) NOTE: The arrows on the damper selector must be aligned exactly or the range of the controller will be limited.0 psi Adjusting the Reset pan (3011) The reset span is factory-set at 5 psi. This is the thermostat pressure difference from which the PVR delivers flow from minimum to maximum setpoints. This range is not normally changed unless a special control scheme is used where control operation must be changed. To field adjust a different reset span, follow these steps: 1. Connect an accurate gage to port G. 2. Apply psi to port T. 3. Adjust reset span to indicate the desired span on port G (see Figure 12). 4. LO-stat and HI-stat delta P must now be readjusted (see following calibration procedure) Figure 12 Adjusting Reset pan Apply psi B H T REET TART LO TAT P NC HI TAT P NO DAPER I N C N C C CR I N C N C CR REET PAN G 0 PI 10 Adjust to obtain desired reset span 7

Calibration Procedures Calibration Procedure (teps 1 4 apply to all thermostat models) 1. Be sure the PVR is installed correctly and that all connections are hooked up to the proper ports. ee Figure 9 for unit application. 2. Remove the caps on the tees which are connected to the lines to the flow sensor. Connect a 0 2" magnehelic gage to monitor flow sensor delta P. The higher-pressure port is further upstream on the air valve inlet. 3. Remove the thermostat line and connect a hand pump with a 0 psi gage to port T. 4. Tee a 0 psi gage in the line from port B on the volume regulator to the air valve actuator. Direct-Acting Thermostat (ee Figure 13 for proper connections) 5. et port T at 0 psi. 6. onitor the delta P and adjust the LO-stat minimum) adjustment to desired minimum. 7. et port T input at 16 psi or greater with the hand pump. 8. onitor the delta P and adjust the HI-stat (maximum) adjustment to desired maximum flow. If the actuator pressure is less than 3 psi, the air valve is wide open and duct pressure must increase to increase flow. 9. et port T at 0 psi. 10. onitor the minimum flow delta P. If it is not correct, adjust the LO-stat adjustment knob. Normally-Open Valve Reverse-Acting Thermostat (ee Figure 13 for proper connections): 5. et port T at 0 psi. 6. onitor the delta P and adjust the LO-stat delta P (maximum) adjustment to desired maximum. If the actuator pressure is less than 3 psi, the air valve is wide open and duct pressure must increase to increase flow. 7. et prot T to 16 psi or greater with the hand pump. 8. onitor the delta P and adjust the HI-stat (minimum) adjustment to desired minimum flow. 9. et port T at 0 psi. 10.onitor the maximum flow delta P. If it is not correct, adjust the LO-stat adjustment knob. Figure 13 Connections of Direct/Reverse-Acting Thermostat with Normally-Open Valve Normally-Open Valve Direct-Acting Thermostat (ee Figure 14 for proper connections): 5. et port T at 0 psi. 6. onitor the delta P and adjust the LO-stat (minimum) adjustment to desired minimum. 7. et port T input at 16 psi or greater with the hand pump. 8. onitor the delta P and adjust the HI-stat (maximum) adjustment to desired maximum flow. If the actuator pressure is greater than 13 psi, the air valve is wide open and duct pressure must increase to increase flow. 9. et port T at 0 psi. 10.onitor the minimum flow delta P. If it is not correct, adjust the LO-stat adjustment knob. Reverse-Acting Thermostat (ee Figure 14 for proper connections): 5. et port T at 0 psi. 6. onitor the delta P and adjust the LO-stat delta P (maximum) adjustment to desired maximum flow. If the actuator pressure is greater than 13 psi, the air valve is wide open and duct pressure must increase to increase flow. 7. et prot T to 16 psi or greater with the hand pump. 8. onitor the delta P and adjust the HI-stat (minimum) adjustment to desired minimum flow. 9. et port T at 0 psi. 10.onitor the maximum flow delta P. If it is not correct, adjust the LO-stat adjustment knob. Figure 14 Connections of Direct/Reverse-Acting Thermostat with Normally-Closed Valve 0 2' agnahelic Gage 0 2' agnahelic Gage HI LO HI LO Normally-Open Unit Normally-Closed Unit LO Volume Regulator Apply psi LO Volume Regulator Apply psi HI Actuator B H T REET TART LO TAT P HI Actuator B H T REET TART LO TAT P NO DAPER NC I N C N C C CR HI TAT P PI 0 10 Connect 0 psi Gage NO NC DAPER I N C N C C CR I N N CR CR HI TAT P PI 0 10 Connect 0 psi Gage Airflow ensor G Connect Hand Pump 0 2 psi Handpump Airflow ensor G Connect Hand Pump 0 2 psi Handpump 8

pecifications (3011) pecifications (3011) Differential Pressure Range: 0 to 1.0 in. wg inimum etpoint Range: 0 to 1.0" H 2 O aximum etpoint Range: minimum to 1.0 in. wg Operating tatic Range: 0.25 6.0 in. wg Normal upply Air Pressure:.0 psi inimum upply air Pressure: 15.0 psi aximum upply Air Pressure: 30.0 psi Average upply Air Consumption: 28.8 scim at psi Thermostat Pressure Input Range: Adjustable 0 10 psi band from 0 psi Reset tart Point Range: 0 10 psi Reset pan Range: 0 10 psi aximum afe Thermostat Input: 30 psi (closed chamber) Operating Temperature: +40/+1 F torage Temperature: -40/+140 F ain, Thermostat, Actuator and tatic Pick-up Connections:.250 O.D. 9

odel 3501 Pneumatic Volume Regulator odel 3501 The model 3501 Pneumatic Volume Regulator (PVR) is capable of operating with normally-open or normally-closed air valves and can operate with either direct-acting (DA) or reverse-acting (RA) thermostats. Installation 1. Attach bracket either vertically or horizontally to the installation surface. Horizontal is preferred, vertical is acceptable, any other position is not acceptable. 2. Insert controller into its bracket. Controller may be face up, face down, face left, or face right. The controller LO and HI stat delta P must be calibrated in the same position that it is installed. electing Direct- or Reverse-Acting Thermostat (3501) The model 3501 PVR must be calibrated to operate with either a direct-acting or reverse-acting thermostat. The control must also be changed when used with a normally-open or normally-closed air valve. Use the following procedure to set-up the PVR: 1. elect damper action (NO or NC). Loosen damper selection switch screw and align to either the NO or NC pointer with damper pointer and tighten screw. 2. Now determine the type of thermostat that will be used. If a direct-acting thermostat is used, the reset start pressure is typically 8 psi. If a reverseacting thermostat is used, the reset start pressure is typically 3 psi. 3. With an accurate gage (0 30 psi) connected to port G, regulate the thermostat pressure to port T to 10.5 psi. 4. Adjust reset start to indicate 2.5 psi on port G Adjusting the Reset pan (3501) The reset span is factory-set at 5 psi. This is the thermostat pressure difference from which the PVR delivers flow from minimum to maximum setpoints. This range is not normally changed unless a special control scheme is used where control operation must be changed. To field adjust a different reset span, follow these steps: 1. Connect an accurate gage to port G. 2. Apply psi to port T. 3. Adjust reset span to indicate the desired span on port G. 4. LO-stat and HI-stat delta P must now be readjusted (see following calibration procedure). 10

Calibration Procedures Calibration Procedure (teps 1 4 apply to all thermostat models) 1. Be sure the PVR is installed correctly and that all connections are hooked up to the proper ports. 2. Remove the caps on the tees, which are connected to the lines to the flow sensor. Connect a 0 2" magnehelic gage to monitor flow sensor delta P. The higher-pressure port is further upstream on the air valve inlet. 3. Remove the thermostat line and connect a hand pump with a 0 psi gage to port T. 4. Tee a 0 psi gage in the line from port B on the volume regulator to the air valve actuator. Direct-Acting Thermostat 5. et port T at 0 psi. 6. onitor the delta P and adjust the LO-stat (minimum) adjustment to desired minimum. 7. et port T input at 16 psi or greater with the hand pump. 8. onitor the delta P and adjust the HI-stat (maximum) adjustment to desired maximum flow. If the actuator pressure is less than 3 psi, the air valve is wide open and duct pressure must increase to increase flow. 9. et port T at 0 psi. 10. onitor the minimum flow delta P. If it is not correct, adjust the LO-stat adjustment knob. Normally-Open Valve Reverse-Acting Thermostat 5. et port T at 0 psi. 6. onitor the delta P and adjust the LO-stat delta P (maximum) adjustment to desired maximum. If the actuator pressure is less than 3 psi, the air valve is wide open and duct pressure must increase to increase flow. 7. et prot T to 16 psi or greater with the hand pump. 8. onitor the delta P and adjust the HI-stat (minimum) adjustment to desired minimum flow. 9. et port T at 0 psi. 10. onitor the maximum flow delta P. If it is not correct, adjust the LO-stat adjustment knob. Direct-Acting Thermostat 5. et port T at 0 psi. 6. onitor the delta P and adjust the LO-stat (minimum) adjustment to desired minimum. 7. et port T input at 16 psi or greater with the hand pump. 8. onitor the delta P and adjust the HI-stat (maximum) adjustment to desired maximum flow. If the actuator pressure is greater than 13 psi, the air valve is wide open and duct pressure must increase to increase flow. 9. et port T at 0 psi. 10. onitor the minimum flow delta P. If it is not correct, adjust the LO-stat adjustment knob. Normally-Closed Reverse-Acting Thermostat 5. et port T at 0 psi. 6. onitor the delta P and adjust the LO-stat delta P (maximum) adjustment to desired maximum. If the actuator pressure is greater than 13 psi, the air valve is wide open and duct pressure must increase to increase flow. 7. et prot T to 16 psi or greater with the hand pump. 8. onitor the delta P and adjust the HI-stat (minimum) adjustment to desired minimum flow. 9. et port T at 0 psi. 10.onitor the maximum flow delta P. If it is not correct, adjust the LO-stat adjustment knob. 11

pecifications (3501) pecifications (3501) Differential Pressure Range: 0 to 1.0 in. wg inimum etpoint Range: 0 to 1.0" H 2 O aximum etpoint Range: minimum to 1.0 in. wg aximum etpoint Range: 6.0 in. wg Normal upply Air Pressure:.0 psi inimum upply air Pressure: 15.0 psi aximum upply Air Pressure: 30.0 psi Output ensitivity: 5 psi/.02 Average upply Air Consumption: 43.2 scim at psi Reset tart Point Range: 0 10 psi Reset pan Range: 0 7 psi Operating Temperature: +40/+1 F torage Temperature: -40/+140 F 12

CP-3631 Rotary Pneumatic Damper Actuator CP-3631 Rotary Pneumatic Damper Actuator Description: Rotary actuators mounts to a standard ½" diameter shaft by a locking collar and bushing. odels: CP-3631-5000 8 13 psi range (55 90 kpa) Normally-Closed operation CP-3631-8000 3 8 psi range (21 55 kpa) Normally-Open operation Installation ethod: lide collar onto shaft. lide actuator onto shaft noting directional rotation. lide bushing onto shaft into actuator, aligns actuator with damper, lock collar and bushing set screws, and install bracket. aintenance: No routine maintenance is required. pecifications: Effective Area: 8 sq in. (52 sq cm) Normal Rotation: 100 deg upply Pressure: 0 to psig (138 kpa) operating 30 psig (7 kpa) max pring Ranges: Retracted/extended Torque (Based on 0 & psi applied) 8 13 psi (55 90 kpa); 68/59 in. lbs (8/7 Nm) @ 90 deg 3 8 psi (21 55 kpa); 25/102 in. lbs (3/12 Nm) @ 90 deg upply Connection: 3/16" (5 mm) nipple for ¼" (6 mm) OD polyethylene tubing aterial: Body Glass-filled nylon Diaphragm Neoprene Weight: 1.5 lbs (0.68 kg) Ambient Limits: Operating - F 1 F (-29 C 49 C) hipping -40 F 140 F (-40 C 60 C) 13

Constant-Volume Dual-Duct Calibration (3011) Constant Volume Dual-Duct Calibration (3011) This calibration procedure is used when a constant volume of air must be maintained through a unit. On a dualduct unit, a constant-volume discharge sensor is used to measure the air leaving the unit. The PVR controlling to a constant-volume of air leaving the unit uses the discharge sensor to maintain the specified cfm. This PVR does not require a thermostat connected to the PVR. The following procedure must be used when calibrating a constant-volume dual-duct unit. ee Figure 15 for a typical piping diagram. 1. et t-stat to full heat. 2. et LO thermostat (maximum) to the desired maximum flow on the heating deck. 3. et t-stat to full cool. 4. et HI thermostat (minimum) to the desired minimum flow on the heating deck. 5. et LO thermostat adjustment knob on cooling deck (CV deck) to desired constant-volume. 6. Exercise the system to check flows for proper operation. Figure 15 Typical Constant-Volume Dual-Duct Piping Diagram 14

Variable Air Volume Dual-Duct Calibration (3011) Variable-Air-Volume Dual- Duct Calibration (3011) Figure 16 is a typical piping diagram of a VAV dual-duct unit. The unit has a thermostat piped to both pneumatic volume regulators (PVR) which will operate the heating deck from a thermostat signal of 3 8 psi. The cooling deck will operate from a thermostat signal of 8 13 psi. With normal calibration of the PVR, the unit will have both the heating and cooling deck at minimum with a thermostat signal of 8 psi. In order to have a unit minimum cfm and still have 0 cfm minimums on both the heating and cooling deck, special calibration is required. The PVR has a reset start adjustment knob, which allows the unit to be calibrated to a minimum cfm. This is achieved by crossing over the thermostat ranges. Figure 17 illustrates this concept. Figure 16 Typical VAV Dual-Duct Piping Diagram Figure 17 Example N.O. Heating Valve in 0 cfm ax 1000 cfm ax Unit in Valve in 4 7 8 9 12 Unit inimum 400 cfm N.O. Cooling Valve in 0 cfm ax 1000 cfm Thermostat Range: 3 8 psi Heating Valve = 5 psi range Thermostat Range: 8 13 psi Cooling Valve = 5 psi range Approximately 1000 cfm divided by 5 psi = 0 cfm/1b* *Due to the relationship between velocity pressure and cfm; for both the cooling and heating PVR, a linear relationship between cfm and psi does not exist. To obtain a unit minimum cfm of 400 cfm, the heating deck volume regulator must have its thermostat range changed from 3 8 psi to 4 9 psi. This is adjusted by changing the reset start point from 3 psi to approximately 4 psi. The cooling deck volume regulator must have its thermostat range changed from 8 13 psi to 7 12 psi. This is adjusted by changing the reset start point from 8 psi to approximately 7 psi. By overlapping the thermostat spring ranges, we were able to have 0 cfm minimum settings on both the heat and cool deck and still maintain the required unit minimum cfm of 400 cfm. The calibration of the PVR is the same as the normal calibration procedures previously described in this manual. 15

Constant-Volume ingle-duct VAV (VCV 3011) Constant-Volume ingle- Duct VAV ( VCV 3011) This is used when a constant volume of air is required to supply a zone. A thermostat is still often required to modulate a reheat coil to maintain temperature control. The thermostat is never connected to the T port on the volume regulator. The following procedure is used to calibrate this type of unit with a PVR. 1. Be sure there is 0 psi at the T port. 2. et LO thermostat adjustment knob to desired unit cfm. The unit will now modulate to the calibrated cfm setting. ee Figure 18 for typical constant volume single-duct piping diagram. Figure 18 Typical Constant-Volume ingle-duct Piping Diagram HI Flow Ring LO B H L Volume Regulator T Actuator (137.9) Tee (137.9) Two-Pipe Remote-ounted T-tat (Reverse-Acting) 11 (75.8) tage 1 12.5 (86.2) tage 2 14 (96.5) tage 3 Airflow afety witch Electric Heater Terminal Box P.E. tage witch(es) (Normally-Open) Trane An American tandard Company www.trane.com For more information contact your local district office or e-mail us at comfort@trane.com Literature Order Number File Number upersedes tocking Location V-TD-VAV000-VX02B-EN-0302 VAV-VX02A-EN and VAV-IO-6 La Crosse Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. Only qualified technicians should perform installation and servicing of equipment referred to in this publication.