Laboratory Manual for Air Quality Sampling and Analysis



Similar documents
Stack Sampling Stack sampling or source sampling

Portable Air Conditioner

Environmental Monitoring

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

Transferring a Broth Culture to Fresh Broth

Quantifying Bacterial Concentration using a Calibrated Growth Curve

3M Personal Safety Division 3M Center, Building W-75 St. Paul, MN, USA

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

Lab Exercise 3: Media, incubation, and aseptic technique

Course Title: Safety Issues in Electronics Engineering Technology Number of Credits: 3 B.A. B.S. B.A.S A.A. A.S. Degree Type

SAFETY DATA SHEET EVO-STIK GRIPFILL SOLVENT FREE (Irl)

Air Pollution Sampling and Analysis

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Air Pollution Control Division. Technical Services Program

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

NSW Air Quality Monitoring Network: Quality Assurance Procedures

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Validation of process gas systems

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9

ESS Method 130.1: General Auto Analyzer Procedures

Accurate Air Flow Measurement in Electronics Cooling

PREPARATION FOR CHEMISTRY LAB: COMBUSTION

WEATHER STATION FOR SOLAR FARM MONITORING

National- Spencer Inc.

The Ambient Air Monitoring System

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

WSD130 SOLDERING STATION

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

UV100A Ultraviolet Air Treatment System

PORTABLE AIR CONDITIONER

Environment-Laboratory Ambient Conditions

Private Water Supplies Sampling Manual. A Field Guide

Welcome to chapter 10. The following chapter is called Equipment maintenance and monitoring. The author is Ronny Janssens.

Steam Sterilization Cycles for Lab Applications

Dewchecker 2.0. Operating instructions. messen steuern automatisieren - messen steuern automatisieren - messen steuern - automatisieren

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML, 20 MG/0.4 ML AND 10 MG/0.2 ML SINGLE-USE PREFILLED SYRINGE

The photoionization detector (PID) utilizes ultraviolet

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

BACTERIAL ENUMERATION

Contamination Control and Environmental Monitoring Systems

(a) Method 1 Sample and Velocity Traverses for Stationary Sources.

PortaSens ll G AS DETECTOR

Instruction manual for Firstline FCS12000CH

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Environmental Monitoring of Clean Rooms

Why is my air conditioner dripping on my customers?

Cooling Rewarming QUICK REFERENCE GUIDE. First change Target Temp. Always operate in Automatic Mode. Then change Warming Rate

INSTALLING A/C ADAPTER

Why Measure Carbon Dioxide Inside Buildings? By Rich Prill, Washington State University Extension Energy Program

Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P Thermodynamic cycle Heat pump

INSPECTION BEFORE RIDING

Liabilities of Vented Crawl Spaces And Their Impacts on Indoor Air Quality in Southeastern U.S. Homes

Service Manual. Model PM4150 Series. Precision Medical, Inc. 300 Held Drive Northampton, PA USA

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Operating Instructions Split System Air Conditioner

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

T U R B I N E G A S M E T E R

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

What is Dry Ice? Dry Ice Company Safety Rules: DRY ICE: SAFETY DATA SHEET & RISK ASSESSMENT

Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system

i n d o o r a i r q u a l i t y I AQ EN 13779:2007 European standard Camfil Farr clean air solutions

Relative Humidity Calibration Kit

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

Troubleshooting Salt Generators

Microbiological Testing of the Sawyer Mini Filter. 16 December Summary

ASBESTOS AND THE HOME RENOVATOR. A basic guide on what you need to know about asbestos

TR SUPPLEMENTARY REQUIREMENTS FOR THE ACCREDITATION OF CONTINUOUS AMBIENT AIR QUALITY MONITORING STATIONS

Elgin Fire Department

INFRARED QUARTZ WALL HEATER

Technical Cleaning Ó

Environmental Monitoring

TIG INVERTER INSTRUCTION MANUAL

Attachment N o F.2. Please find attached the following procedure: EP-907 Handling Hazardous spills

Rules for Safe Operation

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Failure code manual. content

2014 Aamjiwnaang Air Monitoring Station Results. Ministry of the Environment and Climate Change April 19, 2016

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML SINGLE-USE PEN

Soil Suction. Total Suction

Frequently Asked Questions Generators

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

Standard Operating Procedure for Cleaning Nylon Filters Used for the Collection of PM 2. 5 Material

Online Infrared Flue Gas Analyzer Gasboard 3000

Bottom Loading Water Dispenser

Coating and Extraction of Honeycomb Denuders

Standard operating procedure for Biomass boiler demonstration rig (F12c)

Service Guide. Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines. ORDER No: UN-SVG001A-EN DATE: October 9, 2007

Federal Wage System Job Grading Standard For Laboratory Working, Table of Contents

Pressure Dew Point Probe / Application Information

PREPARATION AND PROPERTIES OF A SOAP

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

GENANO 4500 MEDICAL AIR PURIFICATION DEVICE

READING DEVICE US-05

Transcription:

Laboratory Manual for Air Quality Sampling and Analysis Department of Civil Engineering Indian Institute of Technology Delhi New Delhi-110016

MONITORING OF RESPIRABLE PARTICULATE MATTER 1. Objective Sampling of respirable particulate matter in the ambient and indoor environment air and the demonstration of its concentration in various sizes. 2. Instrument Environmental dust monitor with weather house (automatic sampler) for PM 10, PM 2.5 and PM 1.0. 3. Working principle The dust particles are measured by the physical principle of orthogonal light scattering. Here particles are illuminated by a laser light in an angle of 90 degree. All units of environmental dust monitor use light-scattering technology for single-particle counts. The scattered signal from the particle passing through the laser beam is collected at approximately 90 by a mirror and transferred to a recipient-diode. The signal of the diode is feed, after a corresponding reinforcement, to a multi-channel size classifier. This pulse height analyzer then classifies the signal high of each channel. These counts of each channel are converted each minute in a mass distribution from which the different PM values derive. Measurement principle 4. Sampling location guidelines Sampling location should be located depending upon the objective of measurement campaign and be kept at an altitude depending upon the type of study region (roadways, industrial area, disposal sites, residential area, etc). Generally it is kept at a height of about 3m to 10m from the ground level and sufficiently away from the disturbance of direct obstacles from the source under consideration. 5. Sampling frequency guidelines Sampling is carried out for various purposes. The regular monitoring campaign of national ambient air quality includes measurement of particulate matter typically for 24 hours at least twice a week making about 104 samples a year.

6. Steps for sampling a. Prepare a sampling assembly. b. Set the time constant depending upon the required averaging period. c. Instrument can be switch on and it will display concentration values in µg/m 3. d. Simultaneously instrument will start recording the concentration values in the memory card. 7. References a. CPCB (2011), Guidelines for the Measurement of Ambient Air Pollutants, Volume-1, Delhi. b. IS 5182 (part 23), 2006, Indian standards Methods for measurement of air pollution, Part-23 Respirable suspended particulate matter (PM 10 ), cyclonic technique. c. GRIMM, environmental dust monitor (model 1.107) manual. d. IS 5182 (Part 14)-2000 (reaffirmed 2005) : Indian standards, Method of measurement of air pollution: Guidelines for planning the sampling for atmosphere. e. Rao, M.N., and Rao, H.V.N., Air pollution. Tata McGraw-Hill Publishing Co. Ltd., New Delhi 1989.

MONITORING OF GASES AND PARTICULATES IN AMBIENT AIR 1. Objective To measure the ambient concentrations of gases and particulate matter by using High Volume Sampler (HVS). 2. Instruments a. High volume sampler (HVS) b. Whatman filter paper c. Impingers 3. Principle PM10 and TSPM are measured by passing air at flow rate of about 1 lpm through high efficiency cyclone which retains the dust particles greater than 10 micron size and allow only fines (less than 10 micron particles) to reach the glass microfibre filter where these particles are retained. The instrument provides instantaneous flow rate and the period of operation (ontime) for calculation of air volume passed through the filter. Amount of particulates collected is determined by measuring the change in weight of the cyclone cup and filter paper. 4. Reagents for gaseous pollutants a. 0.1 N Sodium tetra-chloratemercurate (SO 2 ) b. Sodium hydroxide and sodium arsanite (NO 2 ) 5. Procedure i. For particulates a. Perform leak check of the instrument before starting the sample. b. Filter paper need to be inspected for pin holes. c. Filter conditioning need to be done at 20-25ºC temperature and less than 50% Relative Humidity. d. Never fold filter completely. e. Do not touch filters by dirty hands always use disposable hand gloves. f. Under take regular cleaning of key components of the machine. g. Ensure stable power supply to the machine. Do not leave loose contact of supply wire to the machine. h. Always fill up distilled water in manometer assembly. i. Do not switch on and off machine using Timer Switch. j. Clean impinge and rotameter regularly and also clean manifold once in two months. k. Do not take flow reading immediately after switching on the machine. Give 5 minute for flow stabilization and for heat up the blower components. l. Always attach a new weighed cyclone cup with every filter change. m. Do not switch on machine without filter paper.

n. If machine is not expected to be operated within 48 hrs drain out the manometer water and store machine with water in the manometer tank. o. Do not run machine during rain in open atmosphere. ii. For gaseous The increasing general awareness of atmospheric pollution and its hazards to the health and well-being of industrial workers, educational buildings, offices etc., is bound to result in greater stress on accurate, reliable and frequent assessment of work place pollution and worker-exposure. Use additionally impinge tray with HVS sampler simultaneously sample gaseous pollutants. 6. Calculation for particulates a. Initial Manometer Reading = b. Final Manometer Reading = c. Initial Filter Paper Weight = d. Final Filter Paper Weight = e. Initial Cyclone Cup Weight = f. Final Cyclone Cup Weight = g. Total Suspended Particulate Matter Concentration = 7. References a. CPCB (2011), Guidelines for the Measurement of Ambient Air Pollutants, Volume-1, Delhi. b. IS 5182 Part 2 Method of measurement of air pollution: Sulphur dioxide. c. IS 5182 (Part 6)-2006: Indian standards, Method of measurement of air pollution: Nitrogen dioxide. d. IS 5182 (Part 14)-2000 (reaffirmed 2005): Indian standards, Method of measurement of air pollution: Guidelines for planning the sampling for atmosphere. e. Rao, M.N., and Rao, H.V.N., Air pollution. Tata McGraw-Hill Publishing Co. Ltd., New Delhi 1989.

INDOOR AIR QUALITY MONITORS 1. Objective To understand how to operate the instrument and also know the basic knowledge of indoor air quality (IAQ) monitor. 2. Apparatus Indoor air quality monitor (automatic sampler) for carbon monoxide (CO), carbon dioxide (CO 2 ), temperature and humidity. 3. Indoor Air Quality monitor With 90% of our time spent indoors, determining the quality of the air we breathe indoors is essential for good health and productivity. The IAQ monitor key indoor air quality indicators including CO 2, humidity, temperature and CO. Should these measurements fall outside recognized guidelines; further tests can be made to suggest an appropriate course of action. For example, ventilation studies show that as room temperatures rise above 75 F(24 C) the ability of occupants to concentrate can drop by up to 50% and high levels of carbon dioxide will indicate poor ventilation that results in drowsiness and perceived stuffiness. Both situations are very common and seriously affect productivity. Over-ventilation wastes energy and results in increased building running costs. The Surveyor range has been designed with the user in mind. Minimal training is required to use the instruments as the intuitive menu system and display provide step-by-step guides for each operation that are updated when smart probes are plugged in. 4. Steps for sampling a. Prepare a sampling assembly. b. Set the time constant depending upon the required averaging period. c. Instrument can be switch on and it will display concentration. d. Simultaneously instrument will start recording the concentration values in the memory card. e. Using data transfer cable (ie. RS232 cable) can download data from instrument to personal computers. 5. References a. AQ-5000, indoor air quality monitor manual, QUEST technology, USA.

MEASUREMENT OF METEOROLOGICAL PARAMETERS 1. Objective Measurement of meteorological parameters in the ambient air. 2. Instruments Micrometeorological weather station 3. Sampling location guidelines Weather station should be located depending upon the objective of measurement campaign and be kept at an altitude depending upon the type of study region (for specialized research studies) and should be free from any other obstruction. Generally it is kept at a height of about 10m from the ground level. 4. Sampling frequency guidelines Measurements of weather properties are carried out for various purposes. The regular monitoring campaign includes measurements of wind speed, wind direction, temperature and relative humidity typically every hour continuously throughout year or for the period of interests. 5. Steps for sampling a. Select a location safe and free from any obstruction around. It should be ensured that the direct air flow is not obstructed from any direction. b. Prepare and install a stand firmly at the location. c. After installing wind vane, it is oriented with respect to north and finally fixed properly. d. Prepare and install sensors. e. Connect all the sensors and vane to the micro data-logger. f. Set the time constant for displaying the average statistics of the meteorological parameters. g. Use suitable data cable for retrieving data from the micro-data-logger in the personal computer where data to be stored. 6. References a. SP-61: 1994 General guidelines for automatic weather stations. b. Rao, M.N., and Rao, H.V.N., Air pollution. Tata McGraw-Hill Publishing Co. Ltd., New Delhi 1989.

1. Objective BIOAEROSOL SAMPLING To assess the microorganisms present in the indoor environment. 2. Instruments d. Nutrient Agar (28g/1 Lit.) e. Impinger f. Petri dish (Autoclave at 121 0 C, 15 lbs pressure for 15-20 minutes) g. Sampling pump capable of meeting sampler manufacturer s flow specification (e.g., 28.3 L/min), with flexible connecting tubing h. Cotton gauze pad i. Refrigerant packs, if necessary for keeping samples cool during shipment 3. Procedure a. Calibrate each sampling pump with a representative sample in line. b. Before each run, carefully and thoroughly wipe each sampler stage with rubbing alcohol. Allow to dry. Make sure air passages are not blocked. c. Load sampling media into sampler, remove covers from media, and attach sampler to pump with flexible tubing. d. Take special care to prevent contamination of media during loading and unloading. Do not touch agar surface. e. Sample at known preset flow for an accurately known time. (In heavily contaminated areas, a shorter sampling time may be necessary.) f. Keep collected samples and blanks cool (not necessarily ice-cold) and ship as quickly as possible to a laboratory for enumeration and identification. g. Micro-organisms are spread over the solidified agar medium with a sterile L-shaped glass rod. h. The plates should be incubated in an inverted position to prevent collection of condensation on the agar surface. Unless the surface is dry it will be difficult to obtain discrete surface colonies i. During incubation, the isolated microbes multiply, giving rise to individually isolated colonies in the lightest inoculated areas. j. Avoid pressing the loop or needle too firmly against the agar surface as this will damage it. k. Plating of the medium should be done twenty-four hours in advance of performing the exercise. l. To obtain good results with this technique, the agar surface should be smooth, moist, and free of contamination. 4. References a. Bio sampler operating instructions, SKC Inc, USA. b. Buttner, M.P., Willeke, K., Grinshpun, S.A., Sampling and Analysis of Airborne Microorganisms, Manual of Environmental Microbiology, ASM Press, Washington, DC, 1997, pp. 629-640.