Capacitor Voltage Transformer. Answers for energy.

Similar documents
SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under:

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

HV outdoor capacitor voltage transformers and coupling capacitors Robust design and proven performance

Instrument Transformers Application Guide

World Leader in HV Testing Technology

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

Circulating Current Relay. Type IRXm

MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

Presentation of the France Transfo factories

This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB

Trip circuit supervision relay. Type RXTCS

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

Transformers. Special transformers Reactors products

Power transformers. Special transformers Railway

Wireless Power Transfer System Design. Julius Saitz ANSYS

High Voltage Power Supplies for Analytical Instrumentation

Solar Inverters. Ferrites in Renewable Energies: Solar Inverters. customer requirements. Support and flexibility to design custom product to fulfill

DS 600. A contact free flux gate based current measurement sensor 600A rms

How To Build A Low Voltage Capacitor Lvcp

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Power Capacitor Units for improved power quality

The design and performance of Static Var Compensators for particle accelerators

75 Ω Transmission System

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

TOPOLOGIES FOR SWITCHED MODE POWER SUPPLIES

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

Current Transformers Ratio / Polarity / Types

4 Posiflow Proportional Solenoid Valves

ACCURACY OF POTENTIALTRANSFORMERS

The Do s and Don ts of Pressure Transducers

Transformer Bushings for GIS

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Distributed Temperature Monitoring of Energy Transmission and Distribution Systems

ECEN 1400, Introduction to Analog and Digital Electronics

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

Distribution Voltage Regulators

The benefits of inhibited transformer oils using gas-to-liquids based technology

Voltage Regulator SPAU 341 C. Product Guide

Power System review W I L L I A M V. T O R R E A P R I L 1 0,

Shaft grounding. Carbon brushes for shaft grounding are used in turbo-generators, in distinct AC- and DC motors and as a special application in Ships.

HVDC 2000 a new generation of high-voltage DC converter stations

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

SUCCESS EPCOS Capacitors

COMPARISON OF AIR-CORE AND IRON-CORE REACTORS FOR MEDIUM-VOLTAGE POWER-QUALITY APPLICATIONS

CURRENT TRANSFORMERS FOR ELECTRONIC WATTHOUR METERS ADVANCED MATERIALS THE KEY TO PROGRESS

Lab 14: 3-phase alternator.

Earth Fault Detection Basics in Theory

Low Voltage Transformers Sealed, General Purpose, Dry Type

Understanding Power Impedance Supply for Optimum Decoupling

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Secondary Unit Substations

OLI. Oil level indicator

Online Transformer Insulation Monitoring System BushingGard Product Focus. Maximizing Transformer Uptime and Reliability

EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID

Fundamentals of Mass Flow Control

understanding medium frequency induction melting furnace and its components

Medium voltage product. Instrument transformers for indoor applications Product overview

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

Current and voltage measuring relays

Power Quality Issues, Impacts, and Mitigation for Industrial Customers

Case Studies in On-Line Measurement of PD in Motors Fed by Voltage Source PWM Drives

EFFICIENT ELECTRICAL ENERGY TRANSMISSION AND DISTRIBUTION INTERNATIONAL ELECTROTECHNICAL COMMISSION

High-Voltage GIS yesterday - today - tomorrow

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Bourns Resistive Products


Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

POWER FACTOR CORRECTION

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

THERMAL ENERGY METER MC 108/ET

IRON-CORE REACTORS FOR DETUNING POWER CAPACITORS IN MEDIUM AND LOW VOLTAGE NETWORKS

Proximity Switches RS (Reed Switch)

PM734F - Technical Data Sheet Winding 28

Equipment: Power Supply, DAI, Transformer (8341), Variable resistance (8311), Variable inductance (8321), Variable capacitance (8331)

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

POWERING IN-FLIGHT ENTERTAINMENT EQUIPMENT FOR COMMERCIAL AIRCRAFT

Application Note, Rev.1.0, September 2008 TLE8366. Application Information. Automotive Power

FACT SHEET. BSES, Delhi - Distribution Network. Power Systems Consultancy from ABB

Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World

Problem / Solution. The problem:

Table of Contents. TransformerIQ FAQs 1

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Together we create reliable products, thus ensuring development of power industry of continents.

289 SERIES FLOW METER TRANSMITTERS

Chapter 4. LLC Resonant Converter

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

CAPACITOR BANK TESTING SWP

Transcription:

Capacitor Voltage Transformer Answers for energy.

Capacitor Voltage Transformer Siemens Capacitor Voltage Transformers are based on technology from Trench, a recognized world leader in the design and manufacture of high voltage equipment for application on electric utility and high energy industrial systems. Capacitor Voltage Transformers convert transmission class voltages to standardized low and easily measurable values, which are used for metering, protection and control of the high voltage system. As such, the need for accurate and reliable voltage transformation is essential. Additionally, Capacitor Voltage Transformers serve as coupling capacitors for coupling high frequency power line carrier signals to the transmission line. Today, Siemens is a world-wide leader with an entire range of instrument transformers from 72.5 kv to 800 kv covering: Current Transformers Capacitor Voltage Transformers Voltage (Potential) Transformers Combined Units (Combined Current & Voltage Transformers) The Siemens factory in Aurangabad fulfils the demand of our customers for highly reliable Capacitor Voltage Transformers.

Features Meets all IEC and IS metering and protection classes (other Standards on request) Applications from 72.5 kv 800 kv Quality Assurance in accordance with ISO 900 Capable of carrier coupling PLC signals to the network Optimized insulation system design utilizing stateof-the-art processing techniques with mineral oil & synthetic insulating fluids Stability of capacitance and accuracy over a long period of time due to superior clamping system design Oil expansion by way of hermetically sealed stainless steel bellows assures the integrity of the insulation system over time Maintenance-free oil filled cast aluminum base box Superior transient response characteristics Passive ferro-resonance suppression circuit provides superior damping while not degrading transient response Potential grounding switch to measure capacitance and tan delta

Construction Siemens CVT's consist of two primary assemblies; the high voltage capacitor sections and the base box, housing the electro-magnetic components. Series connected capacitor elements, housed in porcelain shells, each hermetically sealed, are referred to as capacitor sections. The dielectric of the capacitor elements is made up of high quality polypropylene film/paper and impregnated with highly processed synthetic fluid. Each capacitor section is equipped with a stainless steel bellow which will allow the synthetic fluid to expand and contract with changes in ambient operating temperature while maintaining the hermetic sealing. It is over these capacitor sections that most of the high voltage will be dropped. A tap voltage (approximately 5-2 kv depending on type) is taken from the lowest capacitor section and fed to an electromagnetic circuit in the cast aluminum base box. The base box contains the intermediate transformer which will provide the final output voltages via multiple tapped secondary windings, series compensating reactor and ferroresonance control circuitry. The base box is filled with dried mineral oil, protecting the components from environmental deterioration. Ferro-resonance is simply and effectively controlled by utilization of low flux density designed magnetic circuitry and a saturable reactor controlled damping circuit connected across the secondary winding. The ferro-resonance suppression circuit does not adversely affect transient response.

H C TO HV POWER CIRCUIT 2 5 3 6 Notes F a Series Reactor C2 L0 F2 F3 an 2a 2an 3a 2 3 5 6 Intermediate Transformer Filter Protective Gap Faraday Shield Fuses 3an N CAR Note: Connection between internal terminals are made at the factory as required for each unit. Nomenclature H - HV Terminal N - HF Terminal C - Primary Capacitance C2 - Secondary Capacitance Typical schematic diagram of a Capacitor Voltage Transformer Nos. Description Material H. V. Terminal (Ø 30X00mm) 2 2 Porcelain Insulator Porcelain 3 Base Box 6 3 5 5 6 Top Cover Terminal Box Lifting Hole - General arrangement of capacitor voltage transformer Electrical Performance Highest System Voltage (kv rms) One minute power frequency withstand voltage (kv rms) Impulse withstand voltage (.2/50µs) (KV ) p Switching Impulse withstand voltage (250/2500 µs) (KV ) p 72.5 0 325 23 230 550 5 275 650 25 60 050 20 630 25 050 765 975 200 550

For more information, please contact: Western Region: Eastern Region: Northern Region: Southern Region: Mumbai office: Thane Belapur Road, Thane - 00 60 Tel.: (022) 2762 3990 Fax: (022) 2762 8002 Vadodara office: Ohm Business Park Ellora Park, Subhanpura Vadodara - 390 023 Tel.: 0265-6692 00 Fax: 0265-6692 90 Kolkata office: 3, Shanti Palli Rasbihari Bypass Connector Kolkata - 700 02 Tel.: (033) 2 9302 Fax: (033) 2 902 Delhi office: Plot No. 6-A, Sector 8 Maruti Industrial Area HUDA, Gurgaon - 22 05 Tel.: (02) 28 6000 Fax: (02) 28 606 Chennai office:, Mahatma Gandhi Road P. O. Box No. 3323 Chennai - 600 03 Tel.: (0) 2833 Fax: (0) 2833 50 Siemens Ltd. Energy Sector - Energy Transmission Aurangabad Works: E76 MIDC Waluj, Aurangabad, India. 3 36 Tel: +9 20 2565 9 Fax: +9 20 255 70 Order No.: PTD-03-52-02 Product development is a continuous process. Consequently the data indicated in this leaflet is subject to change without prior notice. For latest issue contact our Sales Office.