BURNERMATE UNIVERSAL INDUSTRIAL BOILER CONTROLLER System Overview. Fresh Air FGR FGR. Oxygen. Windbox

Similar documents
C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Tips for burner modulation, air/fuel cross-limiting, excess-air regulation, oxygen trim and total heat control

HC900 for Boiler Control Applications

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

OROT RABIN POWER STATION UNITS x 350 MW

Boiler Preparation, Start-Up and Shutdown

500 to 1600 HP with Preferred Burnermate Universal Industrial Combustion Control

HC900 Boiler Control. Background. Solution. Application Brief Industry: Manufacturing

Guidelines for Preparing for a Temporary Steam Plant

CT556 Boiler Efficiency Modern Controls for Package Boiler Operations

HVAC Processes. Lecture 7

GPD 506/P5 Start-up Procedure and Checklist

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Energy Saving Solutions. Bob Montgomery Technical Solutions Specialist Waterloo Manufacturing

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

PRODUCT PROFILE FEATURES

Y-200 Multi-Stage Sequencer

Operational Overview and Controls Guide

Boiler Tune-up Guide

IPB-IB ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL INDUSTRIAL STEAM BOILERS. BECK VIDEO Scan w/ Smartphone

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS

Fossil fuel heating equipment

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

*.ppt 11/2/ :48 PM 1

ABB PSPS Erich Steinmann; Generator control-2013

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Chapter 9 N.C. C. N.O. Single-Pole Double-Throw

UNIFIED FACILITIES GUIDE SPECIFICATIONS

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

7800 SERIES Relay Modules

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

Electronic Flow Switches

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Specifying a Variable Frequency Drive s

Online Infrared Flue Gas Analyzer Gasboard 3000

Diesel Engine Driven Generators Page 1 of 6

Commercial Boiler Systems and Controls

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

Department of Veterans Affairs VHA DIRECTIVE Veterans Health Administration Washington, DC October 15, 2008 BOILER PLANT OPERATIONS

SECTION VARIABLE FREQUENCY DRIVES

MP-4000 Alarm List (Software version or later)

7800 SERIES RM7838B,C Relay Module

Signature and ISX CM870 Electronics

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

AIS750 Series Alarm Annunciator

Section: R100 Bulletin: R Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System

32VFD Variable Frequency Drives for Centrifugal Chillers

Combined Cycle Control Overview

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Controller Automation, Model II+

Air conditioning, electrical testing

PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator

Trouble Shooting Guide

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Factory owners must ensure the boiler is:

Telefon (+45) Telefax (+45) Installation and operating manual

Features and Benefits

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Originators of the Flexible Water Tube design

Procidia Control Solutions Dedicated Backup in a Single Variable Control Loop

PART 11: START-UP PROCEDURES FOR THE INSTALLER

GE Energy Industrial Solutions. New. AF-6 Series Drives. Built-in features Built-in simplicity. GE imagination at work

Thermo Top - Troubleshooting Tree

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications

Medical Vacuum Systems-PXMI

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

DUCT SMOKE DETECTOR D4120

Boiler NOx Emissions and Energy Efficiency

Table of Contents. TransformerIQ FAQs 1

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

Variable Air Volume - VAV

Industrial Steam System Process Control Schemes

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Commercial Semi-Instantaneous Water Heaters

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

Safety Requirements Specification Guideline

A Practical Guide to Free Energy Devices

Some Criteria for Choosing a Steam Boiler for a Microbrewery

Autoflame PC Software Guide

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Alarms Trips: The Ups and Downs

Oil and Coolant Circulating Heating System. Model - OCSM

Transcription:

BURNERMATE UNIVERAL INDUTRIAL BOILER CONTROLLER ystem Overview INDUTRIAL ystem Overview Fully Metered combustion control is now available off the shelf in an economical, pre-engineered, parameter-driven control package. The BurnerMate Universal Industrial includes the following features: Patented Predictive Full Metering fuel-air ratio control Cross-limited Actuator, Position Pacing ingle PID fuel-air, ratio tuning Air flow temperature compensation flow pressure compensation Windbox O 2 Trim + Flue O 2 Air Flow Trim The BurnerMate Universal Industrial also includes all of the features in the Basic and Expanded versions of BMU: Precise high torque ervo Actuators ( 3 ft-lb -> 720 ft-lb, 8 sizes), ID & Fan and BFW Pump V drive control NFPA 85 compliant Burner Management ystem (BM) Fresh Air Individual Interlock Annunciation with advanced Lockout Data storage Low Fire, Fuel Changeover Firing Rate, Feedwater and Draft control Oil Atomizing Pressure control with etpoint Curve Large 10 color Touch creen OIT with pre-programmed graphics (Note: 15 also available on custom applications) Modbus communications Oil team Digester pulser FE PT** Oil Fuel3 V Motor Atomize PT** or dp Oxygen AT Windbox TE Draft Oxygen Boiler Draft Typical Fully Metered BurnerMate Universal Industrial P & ID. PT AE TE LT Drum Drum Level Feedwater 181

BURNERMATE UNIVERAL INDUTRIAL BOILER CONTROLLER ystem Overview The BurnerMate Universal Industrial is available off-theshelf for immediate delivery, requires only wiring and parameter setup to be operational and is NFPA 85 compliant and U.L. recognized. Predictive Metering Combustion Control The BurnerMate Universal Industrial offers a patented metering fuel-air ratio combustion control technique using a unique control strategy referred to as predictive metering. The ideal combustion control strategy maintains a preset fuel-air ratio over the entire load range of a boiler despite changes in fuel supply, combustion air and draft conditions, and also provides rapid load change response. Traditional fully metered combustion control systems have the following weaknesses: Two PID loops are required, making tuning difficult Cross Limiting Lead-Lag causes Air Rich operation during Load changes luggish response to load changes caused by PID and Cross Limiting Lead-Lag interactions Air Flow meter inaccuracies at low flow rates limit Burner turndown capabilities Flow meter malfunctions disable the burner, or require manual operation until repaired Until now, Fully Metered control systems were custom so their benefits were not available off-the-shelf Preferred s patented predictive metering combustion control strategy combines multiple fuel, air, and ascommissioned feedforward curves (which predict ervo/ VD changes during a load change), with measured flow rate based PID fuel-air ratio control that incorporates a robust cross-limited position pacing algorithm. Predictive metering uses as-commissioned measured fuel flow rate and air flow rate curves to ensure that the PID fuel-air ratio remains at the as-commissioned fuel-air ratio setpoint for every firing rate. Predictive metering, combined with position pacing logic, assures much more precise actuator positioning and assures that each servo remains on curve during load changes. This allows the controller to increase or decrease firing rate more quickly, without concern for fuel rich or fuel lean burner operation. These strategies are of particular importance when applied to sensitive low NOx burners with narrow limits of flammability. Because predictive metering combustion control uses both the servo actuator position feedback and fuel and air flow meter inputs, metering combustion control can be selectively turned off at low firing rates where air flow meters may not be as accurate. Most importantly, if a flow meter malfunctions, by simple parameter selection the BMU Industrial controller can be directed to operate as a parallel positioning combustion control system with oxygen trim until the flow meter is repaired or replaced. Traditional fully metered systems can only be run in manual when there is a flow meter malfunction. Air Flow Fuel Flow Firing Rate Demand A/B O 2 Trim Commission Mode Curves Low Flow PID Disable PID Air Flow P Fuel-Air Ratio etpoint calculator Fuel Flow Air Flow + Fuel Valve FB VD C ro s s L imited P os ition P acing BMU ervos: Fuel Valve VD BurnerMate Universal Industrial Predictive Metering Control chematic 182

BURNERMATE UNIVERAL INDUTRIAL BOILER CONTROLLER ystem Overview Because predictive metering is pre-programmed and only application-specific parameter setup is required to make the controller function, BurnerMate Universal Industrial is much easier to commission and operate than traditional fully metered combustion control systems. The single PID block (rather than the two required for traditional systems) requires that only one set of PID values need to be tuned during commissioning. Inputs for predictive metering combustion control include: Combustion air flow Combustion air temperature Fuel 1 Oil flow (pulser or 4-20 ma) Fuel 2 (natural) gas flow Fuel 2 (natural) gas pressure** Fuel 3 (digester or other) gas flow** 0.5 sec travel Position Pacing Damper VD 0.5 sec travel Fuel Valve Two ervo Example of Position Pacing **Note: The fuel 3 flow, gas pressure compensation, and atomizing pressure control transmitters all share a single BMU Industrial input. Only one of the three can be enabled (field selectable). Fuel and steam flows are also totalized. Each of these flow rates and flow totals has a Modbus address for display on the local OIT Touch creen or remotely via Modbus on Plant DC system OITs. BMU Industrial Fuel-Air- Cross Limited Position Pacing Position pacing is a unique feature of the BurnerMate Universal Industrial that assures the positions of all fuel, air, and ervos and related VD speeds remain on curve during load swings. Position pacing helps avoid: Periods of lean combustion that can cause rumbling, vibration, or flame-outs during firing rate increases Fuel rich conditions that can cause smoking, burn-back, and excessive CO or unburned hydrocarbons during firing rate decreases With traditional fully metered control systems, the solution to these problems is to slow down the response to firing rate changes, and to tighten cross limiting lead-lag to assure that the fuel and air flows remain on curve. For such systems, it is not unusual for low to high fire response times to be 4-8 minutes. BMU Industrial position pacing assures that all servo actuators remain on curve in the following manner: All fuel, air, servos and VDs move together and on curve --there is no fuel or air lead or lag. Each ervo and VD has precise position or speed feedback to insure that all devices are cross limited. The BMU Industrial knows how far each servo actuator and VD can move in 0.5 seconds and uses selfadaptive position pacing to ensure that load changes never cause any servo or VD to lag behind the others. Εvery 0.5 seconds, the BMU Industrial examines all curves to find the servo or VD worst case 0.5 second move caused by a requested firing rate change. Based on the curves, all other servos or VDs target positions are scaled back to ensure that ALL devices arrive on curve at the end of the next 0.5 second move. BMU Industrial position pacing is fully automatic, provides for safer combustion control, drastically improved firing rate response times, and requires no user adjustments. Description Catalog Number BurnerMate Universal Industrial chassis. Includes oxygen compensation inputs, and expanded processor with draft and feedwater control. LCD Keypad shipped loose for enclosure-mounting. BMU-2ZN1 Note: BMU Industrial servos, scanners, oxygen analyzers and flow transmitters are required for a complete system. 183

BURNERMATE UNIVERAL INDUTRIAL BOILER CONTROLLER uggested pecifications 1. Quality Assurance The boiler control system shall be manufactured and supported in the United tates by Preferred Instruments. The burner fuelair- ratio control system and the burner flame safeguard system shall be manufactured and labelled in accordance with U.L. 372, U.L. 1998, and CA C22.2 #199. imply supplying UL recognized individual components is not sufficient. The assembled control cabinet as a whole must be inspected for proper wiring methods, fusing, etc., and must be labeled as conforming to UL508A and CA C22.1 #14. Inspection and labeling shall be supervised an OHA approved Nationally Recognized Test Lab (NRTL). The system shall comply with NFPA 85 Requirement for Independence, the flame safeguard system shall be provided with independent hardware, and shall be physically separated from the combustion control logic. 2. Predictive Metering Combustion Control A fully metered combustion control system with oxygen compensation and (optional) VD control shall be provided for each boiler. Each system shall be designed to provide continuous boiler operation within boiler design limits with a high level of safety and energy efficiency. Fuel flow, air flow, and servo position for up to eight servos will be continually monitored and held on curve during boiler load changes. For convenient setup and faster response to load changes, the fully metered combustion control logic shall contain only one PID loop. As required the system shall provide continuous monitoring and control of steam pressure (or water temperature), and water level. If a flow meter is out of range or inoperative, the control strategy can be switched to parallel positioning, by parameter selection. The system shall be fully integrated to the burner management system to provide fully automatic, safe and reliable startup and shutdown. 3. Oxygen Compensation ystem Provide a boiler breeching mounted in-situ, zirconium oxide oxygen analyzer for each boiler. Extractive type oxygen analyzers are not acceptable for combustion control. The probe shall be of a suitable length to sense the oxygen level in the middle third of the breeching. All wetted parts shall be stainless steel. The oxygen analyzer shall: Include continuous self-diagnostics with diagnostic codes for at least 10 common faults. Automatically send the trim control to the null position and trigger the alarm dry contacts in the if an oxygen analyzer faults. The detector shall be field replaceable without removing the probe from the stack and shall not require special tools. The analyzer shall automatically perform periodic detector cell impedance tests to be used by the operator as an indication of calibration shift. Analyzer calibration shall be pushbutton semi-automatic (no trim pots) with English language prompts and diagnostic messages. Analyzer output shall be field selectable as 0-10% or 0-21% without field re-calibration. 4. Windbox Oxygen Control The controller shall accept an analog input for burner windbox oxygen to be used as a measure of flue gas recirculation rate. During commissioning, a windbox oxygen vs. firing rate curve shall be established. The controller shall modulate the flue gas recirculation valve (or flue gas blower motor VD) to maintain windbox oxygen on the pre-established curve despite changes in ambient conditions. 5. Atomizing Media Pressure Control The controller shall accept an input for atomizing steam pressure or atomizing steam/ oil differential pressure. During commissioning, an atomizing steam pressure (or atomizing steam/oil differential pressure) curve shall be established. The controller will modulate an atomizing steam flow control valve to keep the atomizing steam pressure on curve at all firing rates. 6. Flame afeguard ystem (FG) Integral to the control system furnished shall be a Burner Management ystem (BM)/ Flame afeguard ystem (FG) controller. The system shall be designed to ensure the safe startup, on-line operation, and shutdown of fuel firing equipment. Burner management system components shall be located in the combustion control cabinet and shall be fully integrated for automatic sequencing of light off and shutdown. For safety the BM microprocessor and BM VD shall be on a physically separate circuit board. Microprocessor-based FG shall provide: safety interlocks, flame monitoring protection, and timed sequences. equences shall include forced draft fan start and stop, furnace purge, burner light off and shutdown and post-purge. The FG shall be capable of firing up to three fuels (two gas fuels, one oil fuel), one fuel at a time. Fuel changeover shall be from oil to gas, or gas to oil firing shall be accomplished at low fire without boiler shutdown per NFPA. A front-mounted panel with English language, four line, twenty character LCD message display shall be provided to display flame signal strength, startup and shutdown sequence status, alarm, system diagnostic, first-out messages and burner historical information. Historical information shall include the status of all limits and servos for the last ten lockouts. To ensure boiler low water cutouts are working correctly, the controller shall be capable of performing a daily automatic water column blow-down test. The user shall select the time of day and duration of the water column blow-down test. The controller shall ensure the low water cutoff switches are functioning correctly, and alarm the operator or lockout the boiler if it detects a switch malfunction. To prevent nuisance trips, the flame safeguard system shall accommodate two flame scanners with one required to prove flame. The controller shall provide 120 VAC or 24 VDC scanner power, and accept two analog inputs for flame strength indications. Flame safeguard system shall include oil gun post purge for oil firing. Reliable low fire cutoff shall be provided. For additional nuisance trip protection, field adjustable time delays shall be provided for F.D. fan start, fresh air damper, minimum air flow, low draft cut out, and fuel pressure limits. Five field selectable auxiliary relays shall be included for common alarm, auxiliary fan start, blow-down, flame on, fuel valve open, hot water pump or valve. To protect against dry firing, an option shall be available for high flue gas temperature lockout. To ensure air switches are functioning, minimum air flow pressure switch and purge air flow pressure switch shall be tested for safe starting. 184

BURNERMATE UNIVERAL INDUTRIAL BOILER CONTROLLER uggested pecifications 7. Feedwater Control Provide a boiler water level controller capable of single-, two-, or three-element feedwater control with the ability to automatically switch between control strategies dependent on system demands. 8. Draft Control The controller shall provide two-element draft control using a Preferred Instruments JC-22XMTR draft transmitter. Burner firing rate shall be used as a feed forward for improved response to load changes. The control shall provide both automatic and manual damper control. All adjustments shall be made from the front panel display in engineering units. 9. Flue Recirculation Valve Control The controller shall have a characterizable setpoint curve for damper or variable speed fan output signal. All the logic required to verify that pre-purge, post purge, light-off, and burner modulate cycles are automated shall be provided within the controller. Alternatively, the control will regulate according to a preset windbox oxygen setpoint curve. 10. Additional Control Requirements: Minimum number of curves to be provided per servo: 6 Minimum number of points per curve to be provided: 11 Cold low fire cutback shall be provided when is utilized for NOx reduction. eparate curves shall be provided for fan full speed bypass of VD in case of VD failure. Controller shall include the capability of receiving a remote firing rate input and remote set point input. Controller shall include dual outdoor reset setpoint curves (normal and setback) Controller shall include warm standby start/ stop cycle. Controller shall include low fire hold, and cold start warm up ramping. All external or auxiliary power supplies necessary for electronic transmitters (or final control element) shall be included. Boiler control software shall be U.L. 372/ U.L. 1998 recognized and inaccessible to prevent tampering. Unit commissioning shall be by parameter selection, not requiring ladder logic or blockware programming. The controller shall accept standard 4-20 ma, 1-5 VDC, or RTD inputs for analog inputs. No special sensors shall be required. 11. OIT Color Touch creen Provide as an option a ten (10) inch Operator Interface Terminal (OIT) designed to provide local operation, graphic display of information, alarm message display, historical and real time trending, remote controller tuning, x/y plots of fuel-air curve data for intuitive commissioning, Ethernet connectivity and standard internet browser remote communication. The OIT shall contain a minimum of 75 graphic pages and be networked to the boiler control and burner management systems. The OIT shall provide graphic pages allowing step-by-step commissioning of the controller parameters using English language prompts and selections. The system shall be an industrial hardened operator interface terminal. The terminal shall be web enabled and allow remote monitoring via a standard internet browser and support Modbus TCP/IP Master, TCP/IP lave, R-485 Modbus Master, BacNet IP, and Ethernet communications. 12. High Torque ervo Features: Easy pushbutton set-up, not requiring the adjustment of internal or external potentiometers. ervo zero, span, and direction of travel shall be accomplished by push-button configuration. Totally enclosed, dust tight, and splash-proof covers. Provide a separate direct acting digital servo actuator for the fuel gas and fuel oil. Electrically isolated shaft position feedback potentiometer, integral brake, 90 rotation in 25 seconds. The actuator shall be capable of being stopped, started, or instantly reversed without losing power or overloading. ervo actuator positioning accuracy: 0.1 degrees. ervo full stroke safe start check shall be provided. For high torque applications such as watertube boiler air dampers, servo torque shall be rated minimum 70 ft-lbs with 0.4 degree accuracy. No servo feedback adjustments shall be required with pushbutton zero setup. Adjustable travel limit switches shall be integral, with re-adjustment not requiring new fuel air ratio curve re-entry. ervos shall be cycled during each light-off cycle, and the feedback from each servo shall be monitored to ensure safe actuator operation. ervos shall be Preferred Instruments, model BMU-M or BMU-UM (high torque). 185