DIF O.T. Ceiling filtration system for operating theatres



Similar documents
CLEAN ROOM MONITORING REGULATORY STANDARDS

Environmental Monitoring

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Environmental Monitoring of Clean Rooms

Essam E. Khalil

FVA/A1 saturated-steam sterilizer

Under sill units. Type FSL-B-ZAS

Air Shower Biosafety Changing Station with Pass-Through Box Pass-Through Box Automatic atomizer for no-contact hand disinfection

ASALAIR BIOHAZARD CABINET MODEL ATLANTIC CYTOCABINET 1200 CLASS II TYPE A2 COD MICROBIOLOGICAL SAFETY CABINET CLASS II TYPE A2

Laminar Flow Cabinets and Workstations

Viledon HEPA and ULPA Filters The Patented Solution for Sterile Air and Clean Rooms. Product Overview

LAMINAR FLOW CABINETS

LAMINAR FLOW FOR ALL YOUR NEEDS

CLASSIFICATION OF CLEANROOMS

Laminar Flow Cabinets

Grilles & Diffusers Series LFP Incorporating

MEDICLEAN. Perfect Hygiene Air-Conditioning Solutions for all Hospital Departments. Weiss Klimatechnik GmbH Geräte- und Anlagenbau

WIBObarrier OCS - Open Containment Systems WIBObarrier CCS - Closed Containment Systems

Cleanroom. For. Sterile Manufacturing Facilities

Particle Monitoring Requirements in Pharmaceutical Cleanrooms

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

Downflo workstation DuSt ColleCtorS

Protection, safety, reliability. And more. LAMINAR FLOW CABINETS AND SYSTEMS

stainless steel pre-assembled manifolds

Medical Waste Autoclaves. Medical Waste Autoclaves

Air and Water Balancing - Sound and Vibration Testing - Cleanroom Services - Building Commissioning Building Envelope Testing Thermal Imaging

Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves

Laminar Flow Hoods and Booths

lindab we simplify construction Air Handling Units Product Overview

Spetec. Laminar Flow Box. Portable Clean Room Technology

CONTAMINATION CONTROL IN HOSPITALS. Isabelle Pautrel Ingénieur Clean Concept Patriarche & Co i.pautrel@patriarche.fr

GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS

Procedures for the Effective Use of Biological Safety Cabinets

MC² Market & Competitive Convergence Air Filters: New Facilities, New Standard

Laminar Flow Panel. Type LFP 2/2.4/B/2. Telephone +44(0) Telefax +44(0)

ENVIRONMENTAL MONITORING

DSRQ - DSRSQ - DSRSQ-THERM

applications laminar flow Laminar Flow Diffusers CRITICAL ENVIRONMENT LAMINAR FLOW: GENERAL

FS209E and ISO Cleanroom Standards

Risk Assessment: Biosafety Cabinet

Unbeatable energy efficient glass curtain wall system

3M Purification Inc. 3M Air Management Products for Your Commercial HVAC Needs. Create. Air. Confidence

Clinic Washer-Disinfectors. Washer-Disinfector Line

Environmental Monitoring

SPECIAL APPLICATIONS

Everything you want to know about USP 797

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

RPV - RP - RA air handling units

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

CLEANROOMS IN PHARMACEUTICAL PRODUCTION

MERO Floor Systems - CleanRoom

Displacement ventilation

Sterile operation scenarios at GSK-Parma

Cartridge Filter Application Notes

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

Introduction FRIGERIO ETTORE spa Lecco (Italy) Rev.09 1 / 19

Compact. Efficient. TROX.

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

Element D Services Heating, Ventilating, and Air Conditioning

CAN DEMAND CONTROLLED VENTILATION REPLACE SPACE HEATING IN OFFICE BUILDINGS WITH LOW HEATING DEMAND?

Howorth Air Technology. Healthcare Air Management Services

Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice

ThermoStar Refrigeration Air Dryers

Air Ceiling Unidirectional Filtering Ceiling

TRIMMING TECH 150. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech150

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

CUNO TM Series NB Bags for Liquid Filtration

STERILE FILTER UNIT MODEL 1200 COD

FlowFAST V. Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Pall in the Brewery (more value per hectolitre) DE Free Clarification FB1795

ENVIRONMENTAL MONITORING / TESTING TO CONFORM WITH ISO14644 & TGA GMP REQUIREMENTS

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

Rotary screw compressors kw 5,5 7, , bar MODULO

Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval

BENCH TECH 150. IVD In vitro diagnostic-medical device. General information Type of instrument: Bench chemical hood. Technical datasheet BenchTech150

Automatic Back-Flushing Filter AutoFilt RF9.

Linear Motion & Assembly Technologies - Guarding System

Company Presentation

Atlas Copco Quality Air Solutions. Compressed Air Filters

Excellent textile care, water and energy savings in one.

Both health-care facility classification and area classification, as per CSA, determine the design requirements.

Ultipleat High Flow Filter System

Confort 160. Sliding Systems. Sapa Building System

SECTION ELECTRIC HAND DRYERS

Dental Solutions. Mach LED 2SC Hybrid Mach LED 3SC with video system Mach LED 130 Dental Mach LED 150

G U I D E L CERTIFICATION EDUCATION TRAINING. Procurement Guideline. National Air Filtration Association Recommended Practice

OPERATING MANUAL LAMINAR FLOW WORKSTATION MODELS M50545 M50546 M50547 M50548 M (TM060-O&M-001 Revision 3)

Particle Counting and Environmental Monitoring In Pharmaceutical / Life Sciences

Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested

DRAINAGE SYSTEMS FOR BEVERAGE INDUSTRIES

Authorized Dealers Access Floors Limited The Studio 15 Huntsmead Northampton NN3 5HT

krones AirCo The air conveyor for PET bottles

Lecture 30: Cleanroom design and contamination control

Manufacturing. Environmental Monitoring Particle Counts Are Easy B IOP ROCESSTECHNICAL. Scott E. Mackler

BSL3 and BSL4 Autoclaves. Laboratory Line

Qualification of Cleanrooms and Environmental Monitoring - Practical Approaches in Europe

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Transcription:

DIF O.T. Ceiling filtration system for operating theatres

Air filtration and distribution for operating theatres The operating rooms are the hospital areas where it is required the most accurate control of the environmental sterility. As the highest source of bacteria is coming from the medical staff during the operation, the highest concentration of contaminants is located around the surgery table, increasing the risk of wound infections. The concentration of microrganisms is taken as an index of sterility of the environment and it is expressed in number of particles carrying microrganisms. The choice of the air filtration and distribution system for surgery rooms plays a decisive role in creating and maintaining the necessary level of sterility on the operating table, protecting the wound from airborne particles that could contaminate it directly or indirectly, via contamination of the equipment. To this end it is necessary not only to provide an absolute filtration of the supply air but also to guarantee that it has the right velocity (minimum 0.24 m/s) to ensure the removal of bacteria. At the same time it is mandatory to provide adequate comfort conditions (in terms of temperature, air velocity and noise level) for the surgical team. In operating rooms for critical surgery, where it is necessary to ensure the highest standards of sterility, studies and research on field have shown that the air should be supplied through a low turbulence unidirectional flow which requires very high air flow rate, up to 50 vol/h. The filtering ceiling developed by SagiCofim is able to handle these high flow rates ensuring air quality and comfort conditions. Main requirements for operating rooms International Standards Airborne particles control with protection of the operating table Good thermal comfort conditions for the surgical staff Efficient anaesthetic gas removal Fast particle decontamination rate Easy integration with lighting systems Assembling flexibility Ease of installation Italian Standard Draft E02058560 Italian ISPESL Guidelines, 2009 Italian Legislation DPR n.37, 14/1/1997 European Union: ISO 14644-1 France: NF S 90 351 Germany: DIN 1946-4 Switzerland: SWKI 99-3 Austria: ONORM H 6020-1 Russia: GOST R 52539 United Kingdom: HTM 2025 DIF O.T. Ceiling filtration system for operating theatres 2

The best solution: DIF-O.T. The DIF-O.T. ceiling filtration system is the result of the know-how developed by SagiCofim in the techniques of air filtration and distribution for operating rooms. This system, thanks to H14 efficiency absolute filters, allows a controlled air distribution above the operating theatre and represents the best choice to control the contamination levels. Its peculiarity is the capability to guarantee the sterility levels in ISO Class 5 Operational Simulated, i.e. during the intervention, with the surgical team fully operative. This result is achieved thanks to a sophisticated supply air concept based on unidirectional airflow with differential velocities. The system is designed to provide differential airflow velocities decreasing from the centre towards the perimeter. In this way, thanks to a constant, effective and precise washing of the most critical area above the surgery bed, it is possible to guarantee the most aseptic conditions. The lower perimetrical velocity avoid air induction and prevents contaminated air from entering the operating area, also providing high comfort level to the surgical team. One of the unique features of this system is the possibility to obtain the requested ISO class with fast particle decontamination time (Recovery Time), also by reducing the airflow rates and, therefore, the energy consumption. These results are obtained without the use of potentially restrictive physical barriers or air curtains to control the flow: this makes the installation easier and the use of electromedical equipment simpler. The ceiling is fitted with a reverse liquid seal system around the edge of the filters to provide an effective and reliable airtight seal, without any risk of by-pass between filters and housing, which is the critical point to ensure high classes of sterility. Furthermore, this kind of sealing allows a fast and easy filter replacement. Thanks to these exclusive features, the DIF-O.T. system keeps being used in the major health facilities in Italy and abroad. References City Hospital - Policoro Policlinico San Donato (Milano) Fidenza Hospital (Parma) San Gerardo Hospital, Monza Santa Chiara Hospital, Trento Mellino Mellini Hospital, Chiari (Brescia) Health Care Facility Santa Rita, Milano Health Care Facility Bernardini, Taranto Health Care Facility Villa Fiorita, Prato City Hospital - Prato (Firenze) City Hospital - Taranto City Hospital - Courgnè (Torino) City Hospital - Cannizzaro, Catania City Hospital - S. Giuseppe Vesuviano (Napoli) City Hospital - Barcelona (Spain) Hospital Pontresina (Switzerland) Hospital Neuchâtel (Switzerland) Profilo dei flussi d aria differenziati Si identificano 3 aree funzionali a criticità decrescente: 1. Area a maggior criticità: tavolo operatorio. 2. Area occupata dall equipe chirurgica. 3. Area di transito. 3

Key Success Factors Unidirectional airflow from the ceiling with differential velocities Air filtration through absolute HEPA filters No physical guides or air curtains are required. No uncomfortable drafts in the occupied zone No contaminated air induction in the critical zone Class ISO 5 Operational simulated guaranteed, during the surgical room operation, certified according to the Swiss Standard SWKI 99-3. Perfect tightness by means of a reverse liquid seal around the edge of the filters Air return grilles are located in the four corners of the room in two locations: at the floor and at the ceiling level. Modular version also available for easy transport and site assembling DIF O.T. Ceiling filtration system for operating theatres 4

Ceiling structure Complete system for ceiling air filtration and distribution, factory assembled and tested. Standard dimensions: 3,2 m x 3,2 m x 0,4 m, nominal air flow 9.500 m 3 /h * Holding structure, filter frames and top plenum made of AISI 304 stainless steel. HEPA filters, H14 efficiency, with different performance and colours (V1, V2, LV) designed to obtain a decreasing air velocity from the centre towards the perimeter of the surgical theatre. Patented flow equaliser to achieve uniform and constant air distribution over the whole surface even with low velocities. Perfect tightness guaranteed by a reverse liquid seal around the edge of the filters * Models with different dimensions and air flows are available following specific design requests. V1 V1 V1 V1 V1 V1 V2 LV V2 V1 V1 V2 LV V2 V1 V1 V2 LV V2 V1 V1 V1 V1 V1 V1 Filters HEPA filter model MAB rls LV (H14 efficiency, individually scan tested, according to EN 1822). Uniform air flow over the whole surface (±5% relative to the average flow velocity). No additional flow stabilisers are necessary. Very low pressure drop through the clean air distributor No micro-turbulence in the laminar flow area as with conventional filter outlets or perforated plates 5

High performance system Fast recovery time A DIF-O.T. fitted in SagiCofim mock-up room was tested by specialised personnel using an OPC (Optical Particle Counter) and a biological concentration counter. The diagrams show the test results in terms of 0,5 micron diameter particles and CFU (Colony Forming Units). These data were confirmed during the tests carried out on site and certified by independent laboratories. N particelle 0,5 micron 1.000.000 100.000 10.000 1.000 100 10 1 0 1 2 3 4 5 6 7 8 9 10 tempo - minuti Colony Forming Unit CFU/m 3 100 90 80 70 60 50 40 30 20 10 0 0 1 2 3 4 5 6 7 8 9 10 tempo - minuti Low Particle Concentration The diagram shows the results of the particle count above the operation table. The test has been conducted using an OPC following the ISO 14644-1 procedures. The results refer to tests in at rest situation in operating theatres for real operating conditions. The particle count concentration values fall between ISO Class 3 and 4. numero particelle/m 3 3.000 2.500 2.000 1.500 1.000 500 ISO 3 conta ISO 4 0 0,10 0,20 0,30 0,50 1,00 5,00 diametro particelle (micron) DIF O.T. Ceiling filtration system for operating theatres 6

Design description Standard size 3,2 m x 3,2 m x 0,4 m Rated data Nominal airflow: 9.500 m 3 /h Initial pressure drop: 80 Pa Final pressure drop: 350 Pa Performance ISO 5 Operational simulated according to the Standards SWKI 99-3 (2004), VDI2167(2004) e DIN 1946-4 (2008) Ceiling filtration system for operating theatres with unidirectional airflow with differential velocities, decreasing from the centre towards the perimeter, to provide a dynamic barrier between the operating table and the outer zone. Class ISO 5 according to ISO 14644-1 Operational simulated during the surgical room operation, certified according to the Swiss Standard SWKI 99-3. Holding structure, filter frames and top plenum made of AISI 304 stainless steel. Air filtration with absolute HEPA filters, H14 efficiency, with patented flow equaliser allowing to achieve uniform and constant air distribution over the whole surface even with low velocities. Perfect tightness provided by a reverse liquid seal around the edge of the filters Aerosol sample point before the filter section in order to conduct the integrity test of filtration system according to ISO 14644-3. 7

A complete range Following an approach based on sustainability, SagiCofim is committed to developing and offer the market a full range of product and solutions for comfort and process applications, to meet our customers needs, without compromising the current and the future environment and to allow next generations to meet their own needs. Through the years our mission has always been the same: provide health, comfort and energy saving, by developing integrated high tech solutions for air filtration, treatment and distribution. For us, sustainability is a powerful energy management concept to improve the financial and environmental performance of the Company s practices, products and services. Our commitment means a 360 approach: environmentally friends product design, Life Cycle Cost improvement, manufacturing, packaging and technical advice to our customers, helping them to choose the right solution. For them and for our Planer. Our Company s environmental management system has been certified according to ISO 14001. Air filtration is the most effective way to guarantee Indoor Air Quality both for the people and for the preservation of materials and equipment. SagiCofim filters include a complete range of product with every level of efficiency for all kind of civil and industrial applications. Filter panels, bag filters and compact filters, Class G - F Mini pleated and deep pleated high efficiency or absolute filters, Class F - E - H - U Gas-phase filtration Industrial filtration Hospital applications All solutions are developed in order to obtain the best performance in terms of: High efficiency Low pressure drop High dust holding capacity for a longer filter life Use of recyclable and incinerable materials Reliability and certified performance SagiCofim spa Comfort Filtration Engineering via Firenze 1 20063 Cernusco sul Naviglio tel +39 02 929021 r.a. fax +39 02 92902300 info@sagicofim.com www.sagicofim.com