Pressure Dew Point Probe 0636.9840 / 0636.9841 Application Information



Similar documents
Instruction Manual. T3111 T3111L T3111P T3111Ex

testo 6721 Dew point monitor P2A software for testo 6721 Instruction manual

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Kompressoren. Adsorption Dryer AD

Relative Humidity Calibration Kit

How is Dew Point Measured Reliably?

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DISSOLVED OXYGEN METER Model : DO-5509

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

ThermoSorb Desiccant Dryers

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

Membrane air dryers MS-LDM1, MS series

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

CYMAQ Marking System AS200 + DS7050 N-14

Mounting Instructions. Torque Transducer. A en

Dew-Point Measurement Solutions

Milwaukee USER MANUAL

Microwave Meter. Instruction Manual

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

Duct Humidity Transmitter

Rense Product Range. Customized Humidity Solutions. Rense Product Range

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Trace Dissolved Oxygen Sensor

Solar energy Solar technology in endurance testing

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Dissolved Oxygen Sensors

Adsorption air dryers ADS 1 215

RS DIGITAL THERMOMETER

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Portable digital microprocessor thermometers with interchangeable probes

testo 6651 Humidity transmitters testo 6600 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual Volume 2

Measurement data monitoring system

CG PTFE Diaphragm Liquid Transfer Pump

Professional Thermohygrometer

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

BB-18 Black Body High Vacuum System Technical Description

T0118 T2118 T3118. Instruction Manual

Extract of the White paper Reduce energy costs in compressed air systems by up to 60%

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

testo 6383 differential pressure transmitter testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software

Measurement data monitoring system testo Saveris.

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

testo 6383 Ethernet differential pressure transmitter testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software

Owner s Manual

testo 6681 Humidity transmitters testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual Volume 2

On request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant.

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

Committing to the future. Everything under control: With testo Saveris TM, measurement data are under control everywhere.

A/C refrigerant system, overview

Overflow valve with thread connection

Operations Manual Blast Chiller

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Multifunction HVAC and IAQ Meter

Engine test rig 4. SN: /008 Tuning AG Munich. Sports car 911. Cleanroom QS / m/s C hpa

Thermistor Thermometer MODEL NO

804 Ti Stand. Manual EN

Capteur température et humidité pour HVAC

Operation Manual For NDJ-8S Digital Rotary Viscometer

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL

Titrette. class A precision. The next generation Digital Burette!

Refrigerated Air Dryers. Catalogue

4/2-Way Pneumatic Solenoid Valve

Compressor Service & Maintenance Manual

KNC Model 3666 Automatic Pressure Calibration System

testo 6381 differential pressure transmitter testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software

COMBIMASS. Technical Data COMBIMASS eco-bio +

USER'S GUIDE. Vaisala HUMICAP Humidity Transmitter Series HMP140A U175EN15

Test equipment for temperature and its reduction

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Hygro-Thermometer + InfraRed Thermometer Model RH101

Rotary screw compressors kw 5,5 7, , bar MODULO

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

Pressure regulating valve with modulating kit, type DRV

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Bedienungsanleitung Instruction manual Mode d emploi Manual de instrucciones Manuale di istruzioni Handleiding Руководство пользователя

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Refrigeration Compressed Air Dryer Buran Ultrapulse

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Refrigeration Air Dryers. Catalogue

Highly efficient flue gas analyzer

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

Battery Powered Thermal Mass Flow Meters for Gases

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

SHOWERS SHOWERS

Care and use guide. Contents. a handy solution made easy. page

DRYPOINT RA REFRIGERATION DRYER RANGE

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 4 v2.2 / Modification rights reserved EE210

How To Use A Ds340 (Dsp)

Screw Compressors ESM Fixed Speed & VS Variable Speed

Operator Quick Guide EC SENSOR

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Pocket Tach 99 (PT99) Non-Contact Tachometer

Transcription:

Pressure Dew Point Probe 0636.9840 / 0636.9841 Application Information en

Contents Instrument description...3 User instructions...4 Safety instructions...5 Folding ferrite...5 Operating instructions...6 The pressure dew point probe...6 Measuring...7 Maintenance...8 Control and calibration options...9 Technical data...12 Warranty...12 Ordering data...13 Appendix A...14 Necessary pressure dew point values t pd...14 Appendix B...15 Dew point graph for compressed air...15 The conformity certificate confirms that this product fulfills the guidelines in accordance with 2004/108/EEC.

Instrument description PTFE sintered cap Temperature sensor Humidity sensor Plug-in head connection cable Internal thread Standard plug-in nipple Valve Humidity/temperature probe Measuring chamber Protective sleeve Plug-in head 3

User instructions The two pressure dew point probes guarantee quick and accurate dew point measurement. The probe was developed in cooperation with a world market leader in the compressed air engineering sector. The standard probe 0636.9840 is sufficient for most measurements in compressed-air piping (e.g. refrigeration dryers in the range from 0 to 2 C t pd ). The precision probe 0636.9841 is the ideal probe for highly accurate measurements in the remaining humidity range (e.g. in adsorption dryers to -50 C t pd ). The pressure dew point t pd is the temperature at which compressed air reaches the saturation state (100% RH). This value is an important criteria for the perfect running of the compressed air plant. The probe is connected to the compressed air system via a standard plug-in connector (G1/4ý internal thread to ISO 228-1) or via a screw-on adapter for measurements at test points. If required other standard plug-in connectors with thread G 1/4ý can be screwed into measuring chamber. The sensor is positioned in the flow of compressed air being measured, for the duration of the measurement. The probes can be used, without a measuring chamber, in accordance with the Instruction Manual for the testo testo 645, 445 instruments. By connecting the probe to testo testo 645, 445 the user has a portable, mains independent measuring system. The large display enables the display of the relative humidity or the dew point with the temperature. 4

Safety instructions Read before using the instrument Please read the Instruction Manual belonging to the measuring instrument. Do not exceed the permissible pressure range. Observe the measuring range of the sensor. Overheating can destroy the probe. Observe the permissible storage and transport temperature as well as the permissible operating temperature (e.g. protect the measuring instrument from direct sunlight). If the instrument is opened, improperly handled of if force is applied, the warranty will no longer be valid. Folding ferrite Placeholder: Klapp-Ferrit Heavy electromagnetic load (interfering irradiation from external sources) can lead to incorrect measurements. With the enclosed folding ferrite the probe complies with the guidelines in accor dance with 2004/108/EEC. Attach the folding-ferrite 300mm to the connection Instrument cable: plug The cable can also be used for other Testo probes. 5

Operating instructions The pressure dew point probe Valve to control the air flow rate Place the measuring chamber on the humidity probe adapter and screw on tightly by hand. The humidity probe can also be used without the Make sure that the measuring chamber and the valve are not dirty. Using the valve you are able to control the air flow rate which flows off to get an optimized response time with the humidity sensor PTFE sintered cap, in which case the response times are shorter. However, the probes can become dirty or damaged during assembly or application. If possible always use a sintered cap with the probe. A metal protection cage (Order no. 0554.0755) can be used with absolute oil-free compressed air. Connect the probe to the instrument In order to obtain a real measuring value, let compressed air escape from the outlet for about 10 seconds. Connect the humidity probe to the compressed air plant. Compressed air flows out of the capillary wire (shortening of the response times). ssssssssssssssssss The reduction of pressure at the outlet leads to a physical reduction in the pressure dew point value. See the table in appendix B. 6

Measuring Please read the instrument instruction manual before the switching on the instrument, in order to avoid incorrect measuring results and damage to the instrument. The storage of the humidity probe in areas with temperature and humidity values which differ considerably from those of the compressed air being measured, and dirty sensors or sintered caps increase the response times. Display testo 645/445 The response time is 1 to 5 minutes (typically 2 minutes). Wait until the measured values are stable (approx. 60 s without a change in the measured values). MEASURING LOCATION 41,3 25,1 11,1 %rf C td C HOLD AVERAGE MAX/MIN -22.9td C 7

Maintenance A robust, long-term stable humidity sensor is located in the probe head. Depending on the application and dirt which has gathered, we recommend a quarterly to yearly control with our 0554.0660 control and calibration set. See the instructions on page 10. Clean dirty sensors with alcohol (isopropanol) or distilled water. Unscrew the measuring chamber and the PTFE sintered cap. Dip the sensor in the alcohol, rinse in distilled water and then leave to dry in the air. Do not touch or knock the sensor. Put the PTFE sintered cap back on and screw tightly. Faulty sensors can be replaced, please contact our service department. Dirty PTFE sintered caps can also be cleaned in alcohol or in distilled water. Impurities can be blown out with compressed air. Always blow out the cap from the inside. Dirty measuring chambers can also be cleaned in alcohol or in distilled water, or purged with compressed air Should the measuring chamber be faulty, please contact our service department. 8

Control and calibration options The control and calibration set (Order no.: 0554.0660) is used to control and calibrate humidity probes. The set consists of two special containers. With the aid of different saline solutions, air mixtures with defined relative humidities are produced (for additional information see the Instruction Manual Control and calibration set for humidity sensors ). As part of the accreditation as a calibration laboratory for the parameters Relative humidity and Dew point the values for the relative humidity over the saturated lithium chloride (LiCl) and sodium chloride (NaCl) solutions were newly specified at testo. LiCl 11.3%RH, NaCl 75.3%RH at rated temperature +25 C These improved values also apply to all of the control and calibration sets already delivered. Ignore the values specified up to now. Temperature dependencies Lithium chloride Temperature LiCl Average Tolerance 10 C 11.29 % ± 0.41 % 15 C 11.30 % ± 0.35 % 20 C 11.31 % ± 0.31 % 25 C 11.30 % ± 0.27 % Sodium chloride Temperature NaCl Average Tolerance 10 C 75.67 % ± 0.22 % 15 C 75.61 % ± 0.18 % 20 C 75.47 % ± 0.14 % 25 C 75.29 % ± 0.12 % 30 C 75.09 % ± 0.11 % 9

Control and calibration options General information The humdity probes 0636.9840 and 0636.9841 undergo a comprehensive calibration procedure at testo. Before control and calibration, the probes must be stored at a constant temperature (+20 to +30 C) for approximately 12 hours. The minimum adjustment time is 15 minutes in the test container with screwed in probes. Control and/or calibration Standard probe 0636.9840 P1 P2 - Carefully screw off the PTFE sintered cap - Screw off the protective sleeve - Screw the probe into the test container LiCl (11.3%) - 15 minute adjustment time - Control on the hand-held instrument display - Calibrate, if necessary, by pressing P1 = 11.3%RH ± 2%RH - Screw out the probe from the LiCl test container - Screw the probe into the NaCl (75.3%) test container - 15 minute adjustment time - Control on the hand-held instrument display - Calibrate, if necessary, by pressing P2 = 75.3%RH ± 2%RH - Screw out the probe from the NaCl test container - Carefully screw on the PTFE sintered cap - Screw on the protective sleeve tightly Precision probe 0636.9841 Protective sleeve In addition to the standard calibration the precision probe is subjected to a fine calibration in the factory at -40 C pressure dew point. A control with the control and calibration set is possible. The salt containers are not suitable for calibrating the precision probe. A precision calibration can only be carried out at testo or with corresponding highly accurate reference systems (dew point mirror measuring instruments for compressed air). 10

Control and calibration options Fine calibration With the probes 0636.9840 and 0636.9841 you have the option of a fine calibration on any pressure dew point in the range -50 to +25 C t pd at +25 C (one point calibration). Note A fine calibration is practical only if used with highly accurate reference systems and if the appropriate adjustment times are taken into consideration (at least 15 minutes). The probe 0636.9841 is already optimized in the factory for humidity measurement in compressed air systems. m/s Off Off On How to carry out a fine calibration - Screw off the protective sleeve - Turn the switch right to Offset - Mark down the measured values via P1 (Down) - Mark up the measured values via P2 (Up) The values set last on the hand-held instrument display are saved. Offset Abgleich Calibration Etalonnage 11,3% (DOWN) 75,3% (UP) Factory setting The set fine correction is inactive if the switch is turned to the left (switch position Calibration ). 11

Technical data Sensor:... testo ceramic sensor Measuring range:... 0 to 100 %RH, Pressure dew point t pd :... -60 to +50 C t pd Pressure range:... Overpressure to 15 bar Accuracy, temperature:*... ±0.4 C Resolution:... 0.1 %RH / 0.1 C Temperature range:... Probe: -20 to +50 C Instrument: 0 to +40 C Control point:... 11.3 to 75.3%RH Measuring air flow rate at 6.0 bar overpressure:... 1,0 l/min factory set at... delivery (relating to 0 bar,... +20 C) Response time:... 1 to 5 min typically 2 min Storage/transport temperature:... -20 to +70 C Accuracy: Pressure dew point in C 5 0-5 -10-20 -30-40 ±0.9 Accuracy in C t pd 0636.9840 0636.9841 ±1 ±2 ±3 ±4 - - ±0.8 ±0.8 ±0.9 ±1 ±2 ±3 ±4 * Accuracy referred to a rated temperature of +25 C. The Technical data applies in connection with the testo 600 / 601/650/400 measuring instrument. Pressure dew point probe... 1 year Warranty Measuring chamber... 1 year 12 If the instrument is opened, improperly handled or if force is applied, the warranty will be no longer valid.

Ordering data Description... Order no. Standard probe... 0636.9880... Measuring chamber, Instruction Manual Precision probe... 0636.9881 Measuring chamber, Instruction Manual Plug-in head connection cable (1.5 mtr.) for testo 445/645... 0430.0143 Plug-in head connection cable (5 mtr.) for testo 445/645... 0430.0145 Measuring chamber... 0554.3303... Humidity sensor... 0420.0023 Temperature sensor... 0420.1242 Humidity control and calibration set... 0554.0660 11.3%RH, 75.3%RH, Instruction Manual PTFE sintered cap... 0554.0756 Metal protection cage... 0554.0755 Calibration certificate... 0520.0306 13

Appendix A Necessary pressure dew point values t pd Depending on the type of application, different requirements can be made on the air quality. As the speed of corrosion on steel surfaces increases rapidly above approx. 50%RH, this value should never be exceeded. Field of application Necessary pressure dew point values t pd Factory air, internal pipes 10 C to -10 C Paint spraying 10 C to -25 C Instrument air 10 C to -40 C Sand blasting machine 5 C to 0 C Pneumatic tools 5 C to -25 C Pneumatic conveyor belt 5 C to -60 C Transport vehicles (bus, etc.) -13 C to -33 C Cleaning of optical systems -17 C to -33 C Drying of electronic components -20 C to -40 C Factory air, external pipes -20 C to -40 C Chem. and pharmaceutical plants -25 C to -40 C The pressure dew point t pd is the temperature at which the compressed air is fully saturated (100 %RH). 14

Appendix B Dew point graph for compessed air Grammes of water vapour per m Gramm Wasserdampf je 3 3 of humidity-saturated compressed air g feuchtigkeitsgesättigter Druckluft ( ) m 3 100 70 50 40 30 20 10 7 5 4 3 2 1,0 0,7 0,5 0,4 0,3 0,2 45 40 35 30 25 20 15 10 This graph gives information on the change in the pressure dew point at pressure loss. A drop in working pressure from 8 bar to 6 bar is used as an example here. In this case the pressure 70 65 60 55 50 6 2 0-5 -10-15 -20 dew point is reduced from 10 C to 5 C. The water content falls from 9 g/m 3 to 7g/m 3. The values refer to an ambient temperature of +25 C. 70 65 60 55 50 45 40 35 30 25 20 15 10 6 2 0-5 Pressure Drucktaupunkt dew point ( Ctd) ( Ctd) -30 0,1-10 AIR PRESSURE (bar) LUFTDRUCK (bar) 1 2 3 4 5 7 10 14 20 Working pressure Betriebsüberdruck 0 1 2 3 4 6 9 13 19-25 15

testo AG Postfach 11 40, 79849 Lenzkirch Testo-Straße 1, 79853 Lenzkirch Telefon: (07653) 681-0 Fax: (07653) 681-100 E-Mail: info@testo.de Internet: http://www.testo.com 0973 0609 en 06