EtherNet/IP Scanner Configuration for the Moxa MGate 5105-MB-EIP

Similar documents
1 Application Description System Topology Hardware and Software Requirements... 3

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

1 Application Description Objective Goals... 3

NPort. Copyright 2008 Moxa Inc. Released on July 15, 2008

How to use KEPServerEX OPC Server (Kepware) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)

Using KEPServerEX OPC Server (Kepware)with the iologik E2210

How to use Citect (SCADA) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

The Secrets of RS-485 Half-duplex Communication

EZ-View Network Communications Guide

NPort s Ethernet Modem Mode

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Adding a Modbus TCP Device to the Network. Setting Up Your Network

Technical Information Sheet Page 1 of 8

Immotec Systems, Inc. SQL Server 2005 Installation Document

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

19 LCD / 8 CHANNEL DVR COMBO WITH 160GB HDD & 4 CAMERAS

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

The Shift to Wireless Data Communication

How to Program a Commander or Scout to Connect to Pilot Software

Kurz MODBUS Client User s Guide

General Tips: Page 1 of 20. By Khaled Elshaer.

EZ-ZONE RMA & EtherNet/IP Configuration & Startup Using an Allen-Bradley CompactLogix PLC EtherNet/IP Fundamentals

Host Installation on a Terminal Server

The Secrets of Flow Control in Serial Communication

MGate-4101-MB-PBS Modbus Serial-to-PROFIBUS Slave Gateway User s Manual

Projetex 9 Workstation Setup Quick Start Guide 2012 Advanced International Translations

How to Setup PPTP VPN Between a Windows PPTP Client and the DIR-130.

Biznet GIO Cloud Connecting VM via Windows Remote Desktop

Remote Monitoring of Woodward easygen-3000

ICONICS Using the Azure Cloud Connector

Notification messages

BECKHOFF. Application Notes. BC9000: Getting Started Guide. For additional documentation, please visit.

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

ACTi NVR Config Converter User s Manual. Version /06/07

APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700

Network/Floating License Installation Instructions

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

PART 1 CONFIGURATION 1.1 Installing Dashboard Software Dashboardxxx.exe Administration Rights Prerequisite Wizard

Ethernet/IP Explicit Messaging Using Unity Software

DPS Telecom Your Partners in Network Alarm Management

Installing SQL Express. For CribMaster 9.2 and Later

Configuring Network Load Balancing with Cerberus FTP Server

Important Notes for WinConnect Server VS Software Installation:

How to install and use CrossTec Remote Control or SchoolVue in a Virtual and or Terminal Service environment

S-SupremaConfigurationGuide-DOC 7/23/2014. Suprema Biometrics Configuration Guide ACS OnSite Aparato

Central Management System

Setting up an MS SQL Server for IGSS

FieldIT Limited FieldIT CRM. Installation Manual v1.3.i3 (Enterprise Install)

Version 0.1 June Xerox WorkCentre 7120 Fax over Internet Protocol (FoIP)

How To Set Up A Modbus Cda On A Pc Or Maca (Powerline) With A Powerline (Powergen) And A Powergen (Powerbee) (Powernet) (Operating System) (Control Microsci

Pcounter Mobile Guide

SQL EXPRESS INSTALLATION...

Outlook Profile Setup Guide Exchange 2010 Quick Start and Detailed Instructions

Virtual Owl. Guide for Windows. University Information Technology Services. Training, Outreach, Learning Technologies & Video Production

AXIS Camera Station Quick Installation Guide

Outlook 2010 Setup Guide (POP3)

Install MS SQL Server 2012 Express Edition

Quick installation guide for the Vista Quantum QNVR Network Video Recorder

FLX VoIP Registering with Avaya IP Office 500

Retalix Store Next ISS45 & StorePoint - POS Setup Guide

Application Notes for Configuring Yealink T-22 SIP Phones to interoperate with Avaya IP Office - Issue 1.0

Schneider OS-Loader usage via Ethernet or USB.

Chapter7 Setting the Receiving PC for Direct Upload. Setting the Receiving PC for Direct Upload For Windows For Macintosh...

Instructions for transferring the SINUMERIK HMI to an external screen

Technical Note. Configuring an Omron PLC with Omron FINS Ethernet Driver. 1. Introduction

Demo of Data transferring (.CSV Files) from EGX300 to Our local PC/Laptop using- FTP

Self Help Guide IMPORTANT! F5D Setting Up An Ad Hoc Connection. Please read the following carefully;

Using a Modbus TCP to Profibus PA Gateway by IFAK system

The Answer to the 14 Most Frequently Asked Modbus Questions

Configuring Check Point VPN-1/FireWall-1 and SecuRemote Client with Avaya IP Softphone via NAT - Issue 1.0

How To Create An Easybelle History Database On A Microsoft Powerbook (Windows)

Deploying Windows Streaming Media Servers NLB Cluster and metasan

Wireless G Broadband quick install

CIMHT_006 How to Configure the Database Logger Proficy HMI/SCADA CIMPLICITY

Additional Setup Instructions for Modbus: RTU, ASCII, TCP, Omni & Enron

ScanWin Installation and Windows 7-64 bit operating system

LH110 Series DVR: Frequently Asked Questions

Important Notes for WinConnect Server ES Software Installation:

SNMP Manager User s Manual

Port Forwarding your Router for Use with a Network DVR

How do I set up a branch office VPN tunnel with the Management Server?

Scenario 1: One-pair VPN Trunk

Stratix 5700 Switch Configuration

DDNS Management System User Manual V1.0

Flexi Soft Ethernet IP: Implicit Messaging with a Omron PLC

Quick Start Guide. DVR DS-7200HWI-SH Series DVR. First Choice For Security Professionals

HC900 Hybrid Controller When you need more than just discrete control

Dynamic DNS How-To Guide

Sage Pay User Guide for Sage 200

Configuring the WT-4 for Upload to a Computer (Ad-hoc Mode)

Cisco QuickVPN Installation Tips for Windows Operating Systems

Preparing the Computers for TCP/IP Networking

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Scan to Quick Setup Guide

Setting up the Swann HD IP cameras

Modbus and ION Technology

How To Configure L2TP VPN Connection for MAC OS X client

This techno knowledge paper can help you if: You need to setup a WAN connection between a Patton Router and a NetGuardian.

M-series Virtual I/O Module 2

Transcription:

the Moxa MGate 5105-MB-EIP Contents Moxa Technical Support Team support@moxa.com 1. Introduction... 2 2. Applicable Products... 2 3. System Requirements... 2 4. System Overview... 2 5. Configuring a Moxa PROFIBUS Device Using MGate Manager... 3 6. Communication Test: Monitoring I/O Data... 7 Copyright 2014 Moxa Inc. Released on December 01, 2014 About Moxa Moxa is a leading manufacturer of industrial networking, computing, and automation solutions. With over 25 years of industry experience, Moxa has connected more than 30 million devices worldwide and has a distribution and service network that reaches customers in more than 70 countries. Moxa delivers lasting business value by empowering industry with reliable networks and sincere service for automation systems. Information about Moxa s solutions is available at www.moxa.com. You may also contact Moxa by email at info@moxa.com. How to Contact Moxa Tel: +886-2-8919-1230 Fax: +886-2-8919-1231

1. Introduction This document describes the configuration of a Moxa MGate gateway as an EtherNet/IP Scanner and the EDS-405A as an EtherNet/IP adapter. For the Modbus TCP setup, connect a Modscan32 simulator as a Modbus TCP master with 20 digital inputs. 2. Applicable Products Product Line MGate 5000 series Model Names MGate 5105-MB-EIP, MGate 5105-MB-EIP-T 3. System Requirements Description Model Names Version Moxa EtherNet/IP to Modbus gateway MGate 5105-MB-EIP 1.1 5-port entry-level managed Ethernet switch EDS-405A 1.1 Software utility to configure Moxa devices MGate Manager 1.9 Modscan32 7.A00 4. System Overview In this document, the MGate 5105-MB-EIP is used as an example. The system architecture is shown in the following figure. Copyright 2014 Moxa Inc. Page 2 of 9

5. Configuring a Moxa PROFIBUS Device Using MGate Manager 1. Start MGate Manager and click Search to find. 2. Select the target device and click Configuration. 3. MGate Manager may prompt you for a password. In the Password screen, enter a password (the default is moxa ). Copyright 2014 Moxa Inc. Page 3 of 9

4. Select the Network tab to configure the IP address of the MGate 5105-MB-EIP. In this example, the IP address setting for the MGate 5105-MB-EIP is 192.168.32.2/255.255.255.0. 5. Select the Protocol tab to configure the protocol conversion settings. a. In the Protocol Conversion screen, select the protocol to be converted from the Protocol selection drop-down list. In this example, EtherNett/IP <-> Modbus TCP is selected. Copyright 2014 Moxa Inc. Page 4 of 9

b. In the EtherNet/IP screen, configure the EtherNet/IP settings. In this example, since the EDS-405A is the EtherNet/IP Adapter, select Scanner from the Mode selection drop-down list for the MGate 5105-MB-EIP and click Add to add connection settings. For this example, Input (T O) refers to data (such as information and status report to the originator for monitoring) that is produced by the switch. Output (O T) refers to the data that is generated by the originator (remote host) and is used by the switch. The following figure shows an example for the EDS-405A assembly object. Based on the assembly object, set the following fields: O T (Output) Parameters: Enter 1 in the Instance Number field and 8 in the Data size field. T O (Input) Parameters: Enter 2 in the Instance Number field and 20 in the Data size field. Then, click OK to add the connection. Copyright 2014 Moxa Inc. Page 5 of 9

c. In this example, since ModScan is a Modbus TCP Master, configure Modbus settings in the Modbus TCP tab as shown in the following figure. Mode selection: Select Slave from the drop-down list. Slave ID: Enter 1 for MGate 5105-MB-EIP. TCP port: Enter 502. d. Click OK to save the changes. The MGate 5105-MB-EIP automatically restarts to use the new settings. Copyright 2014 Moxa Inc. Page 6 of 9

6. Communication Test: Monitoring I/O Data 1. Execute the Modsca function on the PC to simulate data exchange from the Modbus TCP master to the MGate 5105-MB-EIP. Copyright 2014 Moxa Inc. Page 7 of 9

The test reads data from the EIP Adapter and monitors the power status. The following figure shows the attribute list for the EDS-405A. The values of bits 6 and 7 become 1 when input power fails. The values of bits 13 and 14 become 1 when there is a power supply. 2. At first, both power supplies are used by the EDS-405A. Copyright 2014 Moxa Inc. Page 8 of 9

The ModSca test screen shows the value 1 in bits 13 and 14. 3. Power supply 1 is turned off on the EDS-405A. In the ModSca test screen, the value of bit 13 becomes 0, bit 6 becomes 1 (to indicate power input failure), and the alarm bit is 1. Copyright 2014 Moxa Inc. Page 9 of 9