These pumps provide a well proven solution in many cases.



Similar documents
Laing industrial pumps

MEMBRANE VACUUM MINI PUMPS

Installation and instruction manual for Laing DDC pumps

Vertical selfpriming Side-Channel Pumps Type WPV

Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + Water removal

SunMaxx Solar Filling Station Operating Instructions

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

Design and Modeling of Fluid Power Systems ME 597/ABE 591 Lecture 5

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Fire Pump Plan Review March 2010

4" SUBMERSIBLE PUMPS

Rickmeier Solutions. Gear pumps for superior Lubrication

A/C refrigerant system, overview

Bringing it all together

Universal Adjustable Fuel Pressure Regulator

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Operation manual and Spare parts list EL PUMP. November

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

N/NH Truck-mounted fire pump series

STAR Linear Bushings and Shafts Supplement RE / Linear Motion and Assembly Technologies

Electric Coolant Pumps. Always at the Correct Temperature

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Electronic Diesel Control EDC 16

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

Rules for Classification and Construction Additional Rules and Guidelines

WASTE OIL DRAINERS 99. Waste oil drainers

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

MANTA Piston Distributor for Oil and Fluid Grease

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

AL-System 6 AQUALOOP System 6. Installation and operating instructions WATER IS OUR ELEMENT.

Hydraulic Control Solutions

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

HP IN-LINE BILLET FUEL PUMPS

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Heating, air-conditioning, cooling

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS

Bedienungsanleitung Diesel-Set 1 (Niederdruck)

The Professional Choice. LDC With DC motor. OLAER LDC optimized for mobile use

Fire Protection Pumps

Series description: Wilo-Yonos MAXO

SJT / SJM / SJP Large Vertical Pumps

Oil and Coolant Circulating Heating System. Model - OCSM

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

Section IV VACUUM PUMPS. Vacuum Pumps: Basic Operation

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Removing chips is a method for producing plastic threads of small diameters and high batches, which cause frequent failures of thread punches.

BOWIE PUMPS OPERATION - MAINTENANCE

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

912. The engine for construction equipment.

GoTo Europe Focused Delivery Program. Product overview industrial and mobile hydraulics

SEPAR FILTER SEPAR 2000 SEPAR 2000

WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS

PS1800 Centrifugal Pumping Systems

Series description: Wilo-Yonos MAXO-D

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

ROTARY SCREW COMPRESSOR. RMD kw

Fixed displacement vane pumps

Diagram of components 2. Reducer..3

Technical Specification. Generating Set with Waukesha engine burning natural gas

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

Rotary screw compressors kw 5,5 7, , bar MODULO

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

Valve systems Base plates, according to standard ISO Brochure

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

FUEL-16, Troubleshooting Fuel Supply Problems

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

Cold milling machine W 1000 F. Technical specification

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

Multistage high-pressure multistage centrifugal pumps

S KID S TEER L OADER SK818-5 SK818-5 SK NET POWER SAE J ,7 kw. OPERATING WEIGHT kg. OPERATING CAPACITY 870 kg

Thermostatic valve Type AVTA

A Practical Guide to Free Energy Devices

Technical Information

Mechanical shaft seal types and sealing systems

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Why and How we Use Capacity Control

The conditions below apply to the curves shown on the following pages.

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS

Jeep Renegade Technical specifications

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Self-operated Temperature Regulators Temperature Regulator Type 1u

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

NORD GEARED MOTORS F Getriebebau NORD. D R I V E S Y S T E M S

Instruction Manual Differential Pressure Transmitter

SPP Pumps Inc. Atlanta

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

Original ATE wheel cylinders. Reduced in weight and resistant to brake fluid

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

MACHINE TOOL DRIVES. Learning Objectives:

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Product catalogue, pipe and sewer cleaning systems

Engine Power Plant 5,2 MW Stationary Dual Fuel (Diesel / Gas ) Engine (12 VDS 48/42 )

Transcription:

Page 1/8 electric fuel pumps Product overview for universal applications PrODuCT INFORMATION Vehicle/application Product PIerburg No. see catalogue/tecdoc CD Electric fuel pump (E1F) 7.21440.51.0/.53.0/.63.0/.68.0/.78.0 (E1S) 7.21088.62.0 (E2T) 7.21287.53.0; 7.21538.50.0; 7.21565.70.0/.71.0 (E3T) 7.21659.53.0/.70.0/.72.0 (E3L) 7.00228.51.0; 7.22156.50.0/.60.0; 7.50051.60.0; 7.28242.01.0 Many customer inquiries reaching our engineering hotline are concerned with the technical data of our fuel pumps for small series or custom applications. In order to provide some decision guidance with respect to a fuel pump suited for your purposes, please find on the following pages a number of universal pumps from our product line. These pumps provide a well proven solution in many cases. For example: as a replacement for mechanical fuel pumps where the original pump is no longer available as a replacement (old-/ young-timers) as a fuel pre-pump for Diesel or Otto engines as a temporary solution for repairs where a special replacement is not available as an additional pump which is additionally switched on depending on demand (failure of the main fuel pump) as a refilling or supply pump in refilling systems, additional tanks or heating systems as an additional pump for tuning and racing applications The right of changes and deviating pictures is reserved. Assignment and usage, refer to the each case current catalogues, TecDoc CD respectively systems based on TecDoc.

Page 2/8 Models In the case of today s modern designs of electric fuel pumps, the pumping stage is seated directly on the shaft of the electric motor. The fuel passes through the fuel pump thereby simultaneously cooling and lubricating it. Advantages: Fewer moving parts Compact design Small outside dimensions Depending on the way in which the fuel pump is accommodated in the vehicle a difference is made between in-tank and in-line pumps. Electric fuel pump For the pumping stage there exist different designs. A rough differentiation is made between flow pumps and positive displacement pumps. Flow pumps In the case of flow pumps the fuel is moved due to the centrifugal force of a rotor. Such pumps are capable of producing lower pressures only (0.2 to 3 bar) and are used either as the pre-stage in a two-stage pump, respectively as a prestage pump. The fuel passes through the flow pump without the need for flaps and valves. For this reason, during standstill of the pump, the fuel may potentially flow backwards through the flow pump. E3TS Flow pumps are not self-priming, i.e. they must always be placed below the liquid level within the fuel tank (maximum suction height 0 mm). Side channel pumps belong to the category of the flow pumps. Positive displacement pumps In positive displacement pumps the fuel is pumped through sealed-off volumes. Such pumps are used in the case of higher system pressures (up to approximately 6.5 bar) as they prevail in conventional injection systems, for example. Except for design related leaks, the fuel cannot flow through the positive displacement pump in the reverse direction even when the pump is at standstill. Toothed ring pumps, sliding vane pumps, roller vane pumps and screw pumps belong to the category of positive displacement pumps. Positive displacement pumps are selfpriming to a very limited extent, i.e. they should be mounted below the liquid level of the fuel tank (maximum suction height 500 mm). Motor model (pumps in mm) 1 = 38 mm 2 = 43 mm 3 = 43 mm performance boosted T F L S Toothed ring pumping stage Sliding vane pumping stage PIERBURG codes for electric fuel pumps Main stage Screw pumping stage Pre-stage Side channel pumping stage Please note: The curves provided in the following are typical pump characteristics and serve only the purpose of providing a rough overview. The pumping characteristic of a pump must not precisely correspond to this curve. Typical pump characteristics will only be attained after a sufficient running-in time has elapsed.!for safety reasons, all work on the fuel system must only be done by suitably qualified personnel.

Page 3/8 e1f (Sliding vane pump) Sliding vane pumping stage Electrical connection Pre-filter Suction side Delivery side DC motor e1s (Side channel pump) Side channel pumping stage Electrical connection Suction side Delivery side DC motor Pressure holding valve 1 e3l (Screw pump) Suction side Pre-filter Coupling Pressure holding valve 1 Delivery side Screw pumping stage DC motor Electrical connection e2t/e3t (Toothed ring pump) Toothed ring pumping stage Electrical connection Pre-filter Suction side Delivery side Pressure limiting valve 2 DC motor Pressure holding valve 1 1 The pressure holding valve maintains a holding pressure 2 The pressure limiting valve opens when the pressure within within the fuel system even with the ignition switched off. the fuel pump increases to unacceptably high levels.

Page 4/8 Model e1f A frequently used pump is the model E1F. This is an in-line positive displacement pump with a sliding vane pumping stage and it is suited for system pressures of 0.1 to 1.0 bar. This pump is available for 12 and 24 Volt operation and is inserted into the line. For 6 Volt operation (in the case of oldtimers, for example) we recommended the E1F No. 7.21440.53.0. In the case of 6 Volt operation, pressure and volume flow are reduced approximately to the half.!maximum suction height: 500 mm (in the case of filled lines) When installing an electric fuel pump (12 Volt) instead of a mechanical fuel pump, we recommend, for safety reasons, the installation of a safety shutdown facility (4.05288.50.0)! See Service information SI 0016A. PIerburg No. Curve Nominal voltage Stat. pressure at Q=0 l/h Volume fl o w System pressure Installation, resp. connection dimensions (see Fig. below) Current consump- at Ø A b C Ø D Ø e tion [V] [bar/(psi)] [l/h] [bar/(psi)] [mm] [A] 7.21440.51.0 1 12 0,27 0,38 (4 5,5) 7.21440.53.0 2 12* 0,44 0,57 (6,3 8,3) 7.21440.63.0 2 24 0,44 0,57 (6,3 8,3) 95 0,10 (1,5) 38 133,5 84,5 8 8 2,0 100 0,15 (2,2) 38 133,5 84,5 8 8 2,05 100 0,15 (2,2) 38 134,2 84,5 8 8 1,35 7.21440.68.0 3 24 > 1,85 (> 26,8) 95 1,00 (14,5) 38 139,5 90,5 8 8 3,0 7.21440.78.0 3 12 > 1,85 (> 26,8) 95 1,00 (14.5) 38 141,5 91,0 8 12 4,3 * also is suited for 6 Volt operation D B C A E

Page 5/8 Model e1s The E1S is offered for installation within a fuel tank. This pump is a flow type pump with a side channel pumping stage for 12 Volt operation. This pump is preferably used as a prepump. Pre-pumps pump the medium at low pressure in the direction of the main pump.!maximum suction height: 0 mm. The pump must be placed within the medium which is being pumped. Model E1S pumps can be used up to a volume flow of approximately 220 l/h as a pre-pump. This prevents the generation of a lowpressure on the suction side of the main pump which might damage the main pump due to cavitation. PIerburg No. Nominal voltage Stat. pressure at Q=0 l/h Volume fl o w System pressure Installation, resp. connection dimensions (see Fig. below) Current consumption Max. suction height at Ø A b C Ø D Ø e [V] [bar/(psi)] [l/h] [bar/(psi)] [mm] [A] [mm] 7.21088.62.0 12 75 0,24 (3,5) 38 100 75,3 8 19 3 0 A B D C E Ø 54,5

Page 6/8 Model e3l Model E3L pumps are in-line pumps with a screw pumping stage. They perform especially well, are quiet and their current consumption at high pressures is comparatively low.!maximum suction height: 500 mm (with filled lines) PIerburg No. Curve Nominal voltage Volume fl o w System pressure Installation, resp. connection dimensions (see Fig. below) Current consumption at Ø A b C Ø D Ø e [V] [l/h] [bar/(psi)] [mm] [A] 7.00228.51.0 1 13,5 300 360 5 (72,5) 43,2 235 175 8 15 16 7.22156.50.0 2 13,5 150 190 4 ( 58) 43,2 214 156 8 15 9,4 7.22156.60.0 1 2 13,5 150 190 4 ( 58) 52 2 214 159 2 8 15 9,4 7.50051.60.0 3 12 205 275 1,8 (26) 43,5 199,5 156 8 8 2,8 6,8 7.28242.01.0 4 13,5 180 260 0,5 (7) 43,2 211 156 8 8 4,5 1 corresponds to 7.22156.050.0 with rubber jacket, 2 dimensions including rubber jacket D C B A E

Page 7/8 Model e2t/e3t Model E2T / E3T fuel pumps are self-priming toothed ring pumps and have been designed to handle higher flow rates. Located on the delivery side is a pressure holding valve, which depending on the model of the pump is either integrated within the pump or is accommodated in exchangeable screw-in fittings. An integrated pressure limiting valve prevents the occurrence of excessively high pressures and thus possible damage to the fuel system. The pressure limiting valve is a safety valve only and is not suited for pressure control purposes!!maximum suction height: 500 mm The E2T / E3T electric fuel pumps have an outside diameter of 43 mm. In connection with the rubber jacket supplied with some of the pumps from this line, they are suited for the purpose of replacing fuel pumps of other manufacturers having outside diameters of 52 and 60 mm (see table, dimension A ). Additionally, the rubber jacket serves the purpose of silencing the pump. PIerburg No. Curve Nominal voltage Stat. pressure at Q=0 l/h Volume fl o w System pressure Installation, resp. connection dimensions (see Fig. below) Current consumption at system pressure at Ø A b C Ø D Ø e [V] [bar/(psi)] [l/h] [bar/(psi)] [mm] [A] e2t 7.21538.50.0 1 12 2,7-5,7 (39-83) 7.21287.53.0 2 12 4,5-7,5 (68-109) 80 1,2 (17) 43 160 110 8 12 < 4,5 100 3,0 (43,5) 52* 160 115* 8 12 < 6 7.21565.70.0 2 12 4,5-7,5 (68-109) 7.21565.71.0 2 12 4,5-7,5 (68-109) e3t 7.21659.53.0 3 12 8,0-12,0 (116-174) 7.21659.70.0 3 12 8,0-12,0 (116-174) 7.21659.72.0 3 12 8,0-12,0 (116-174) 100 3,0 (43,5) 52* 190 115* A, b 100 3,0 (43,5) 52* 190 115* C, b 110 6,5 (94) 52* 178,5 129* b 110 6,5 (94) 60* 178,5 129* D, e 110 6,5 (94) 60* 178,5 129* e 12 < 6 15 < 6 15 < 12 12 < 12 15 < 12 *dimension including Screw-in fittings M14x1,5 Depending on the model, the fuel pump is equipped on the delivery side with a connection equipped with an inside thread. Supplied with these fuel M12x1,5 pumps is one or several screw-in fittings or these have already been pre-assembled (see Table dimension D and the key provided below). A b C D e M16x1 M12x1,5

Page 8/8 Model E2T/E3T (continued) Q[ l/h] 200 160 3 I 16 I[ A] 120 80 40 0 0 2 1 Q Q 2 4 6 8 3 12 8 Q 4 0 10 p[ bar] 12 D 0 50 100 150 p[ psi ] C B A E Summary for a quick overview Pierburg No. Model Nominal Volume System Current Remark voltage flow pressure consumption at [V] [l/h] [bar/(psi)] [A] 7.21440.51.0 12 95 0,10 (1,5) 2,0 7.21440.53.0 12* 100 0,15 (2,2) 2,05 *also suited for 6 Volt operation 7.21440.63.0 E1F 24 100 0,15 (2,2) 1,35 7.21440.68.0 24 95 1,00 (14,5) 3,0 7.21440.78.0 12 95 1,00 (14.5) 4,3 7.21088.62.0 E1S 12 75 0,24 (3,5) 3 In-tank pump 7.21538.50.0 12 80 1,2 (17) < 4,5 Including rubber jacket 7.21287.53.0 12 100 3,0 (43,5) < 6 E2T 7.21565.70.0 12 100 3,0 (43,5) < 6 Including rubber jacket 7.21565.71.0 12 100 3,0 (43,5) < 6 Including rubber jacket 7.21659.53.0 12 110 6,5 (94) < 12 Including rubber jacket 7.21659.70.0 E3T 12 110 6,5 (94) < 12 Including rubber jacket 7.21659.72.0 12 110 6,5 (94) < 12 Including rubber jacket 7.00228.51.0 13,5 300-360 5 (72,5) < 16 7.22156.50.0 13,5 150-190 4 ( 58) < 9,4 7.22156.60.0 E3L 13,5 150-190 4 ( 58) < 9,4 Including rubber jacket 7.50051.60.0 12 205-275 1,8 (26) 2,8-6,8 7.28242.01.0 13,5 180-260 0,5 (7) < 4,5