http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html



Similar documents

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

INTELLI-VENT CONTROL INFORMATION When Used On Gas, Residential, Power Vented Water Heaters

Fossil fuel heating equipment

37E73A-903 & 906 INTELLI-VENT

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

G670 Intermittent Pilot Ignition Controls

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

80UHG. Service Literature

Thermo Top - Troubleshooting Tree

Luna 3 Comfort Troubleshooting Guide June 2008

Tankless Gas Water Heaters Second Generation Indoor, Outdoor and Direct Vent Up to 199,000 BTU

Service Handbook Commercial / Residential gas water heater

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

WARNING CAUTION 21V51U-843 DESCRIPTION PRECAUTIONS

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)


prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Heating Basics Gas Valve Systems

ENERGY SMART TROUBLESHOOTING GUIDE TABLE OF CONTENTS:

SERVICE MANUAL (To be performed ONLY by qualified service providers)

SERVICE MANUAL (To be performed ONLY by qualified service providers)

Model Description / Applications. Intermittent Pilot Gas Ignition Control

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Air Conditioning Sign-Off Sheet

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

SERVICE INSTRUCTIONS

Commercial Gas Water Heater

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

Energy Saver SERVICE MANUAL COMMERCIAL 24 VOLT FLUE DAMPER SERIES WATER HEATER ATMOSPHERIC GAS WATER HEATERS

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Water Priming Mode Purge air from plumbing system. How do I solve ER-3 WATER PRIME: TIPS ON FILLING SPA IMPORTANT NOTE WARNING

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

PRODUCT DESIGN. 5. Furnace awaits call from thermostat.

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

GeniSys 12V. Model Description / Applications. Advanced 12 Vdc Burner Control

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

*.ppt 11/2/ :48 PM 1

CARING FOR YOUR WATER HEATER

Rinnai Tankless. Water Heater. Troubleshooting Manual

HeatSource HS1800 Heater

7800 SERIES Relay Modules

HEAT SIPHON ANSWERBOOK

Installation Questions

DVI 980/982 (Honeywell Nr. S4865) Gas Burner Safety Control

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Tankless. Water Heater. Troubleshooting Manual

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

Technical Information

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

Cooling Capacity CFM in. w.c. (125 Pa)

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

S8910U Universal Hot Surface Ignition Module

SERVICE TIPS. Dometic REFRIGERATORS. Models. OS1927 4/96 Copyright 1996 The Dometic Corporation

DKG 972 Gas Burner Safety Control

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner

AVR Pellet Control Board Installation/Service Instructions

12288 Side Road 22, Wainfleet, Ontario Canada L0S 1V0 Phone: Fax:

OPERATIONAL CHECKS & SAFETY CIRCUIT DESCRIPTION

Service Manual REU - 16 FUA - E. Infinity 16 i. Continuous Flow Water Heater. Important.

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)


Service Manual Models:

SERVICE MANUAL. Flammable Vapor Ignition Resistant Water Heaters. Gas Water Heaters. Troubleshooting Guide and Instructions for Service

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Communicating Controls Service Manual

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Gas Oven Repair Guide

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30

Factory owners must ensure the boiler is:

Munchkin Heat Exchanger Maintenance

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

ECM. Service Guide.

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Transmission electronic controls outline. Inputs- processing- outputs

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

DIGITAL WARMING CABINETS

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Residential Gas and Electric Water Heaters

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

Time Propane Pressure Drop Test Sign-Off Sheet

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Norcold Repair Guide Models 442, 443, 452, 453, 462, 463, 482, 483

E-gas Instant Gas Water Heaters

THE CARE AND FEEDING OF YOUR RV IIl

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

Operator: Save these instructions for future use!

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN

Transcription:

http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html APPLY POWER TO APPLIANCE FIELD WIRING CORRECT? DPLAY ERROR CODE 1 OR 2 Intelli-Vent TM Sequence of Operation REQUEST FOR HEAT PRESENT? PRESSURE SWITCH PROVEN OPEN WITHIN 5 SECONDS? WAIT FOR PRESSURE SWITCH TO OPEN DPLAY ERROR NUMBER3 PRESSURE SWITCH PROVEN OPEN WITHIN 5 SECONDS? WAIT FOR PRESSURE SWITCH TO OPEN DPLAY ERROR NUMBER3 COMBUSTION BLOWER ON COMBUSTION BLOWER ON ONE HOUR AUTO LOCKOUT RESET DELAY PRESSURE SWITCH PROVEN CLOSED WITHIN 5 SECONDS? WAIT FOR PRESSURE SWITCH TO CLOSE DPLAY ERROR NUMBER 4 PRESSURE SWITCH PROVEN CLOSED WITHIN 5 SECONDS? WAIT FOR PRESSURE SWITCH TO CLOSE DPLAY ERROR NUMBER 4 PREPURGE IGNITOR OKAY? TURN OFF INDUCER DPLAY ERROR CODE NUMBER 5 IGNITOR ON FOR WARM-UP TIME COMBUSTION BLOWER OFF TURN OFF INDUCER AFTER POST-PURGE DPLAY ERROR 6 MAIN VALVE OPENS INTERPURGE MAIN BURNER LIGHTS AND SENSED DURING TRIAL FOR IGNITION MAIN VALVE CLOSES LESS THAN 3 TRIES FOR IGNITION? IGNITOR TURNS OFF FLAME SENSE LOST? MAIN VALVE CLOSES LOST LESS THAN 3 TIMES? REQUEST FOR HEAT SATFIED? Please Note: MAIN VALVE OFF The control continually monitors internal circuits and external sens ors. COMBUSTION BLOWER OFF AFTER POST-PURGE DELAY

Apply Power to the Water Heater Is the field wiring correct? Polarity correct Must have earth ground GFI Circuits are OK 1 Apply Power to the Water Heater Verify 120 VAC line voltage to control between 1 & 2 2 Request for Heat Control conducts self check for ECO Thermistor Ignitor resistance FV sensor Self diagnostics Verifies venting is free and clear via the pressure switch 3 1

Turn on Inducer Verify 120V to inducer on yellow line between 1 & 3 You should hear blower on 4 Inducer comes on Is the inducer running? Pushes exhaust gas thru venting Add dilution air to cool gas to work in PVC pipe 5 Verify Pressure Switch/ Temp Probe Works Verify power to over temp switch on blue line (you should hear inducer running) between 1 & 4 6 2

Verify Pressure Switch/ Temp Probe Works Verify 120V from pressure switch on red line between 1 & 5 7 Verifies venting is free and clear because switch operates properly Proving the Inducer & Pressure Switch Works Vent tubing is not kinked Vent over-temp switch is not activated 0.75 inches w.c. on tube Pressure switch will not open Pressure switch will not close 8 Try for Ignition Is the hot surface ignitor present? Is the ignitor circuit with resistance limits? (11.5 to 18.8 ohms) Does the hot surface ignitor glow? Three attempts for flame rectification Then lock out on Max Ignition Attempts 9 3

Ignitor Current Verify voltage to the ignitor here Should be between 70-90 VAC 10 Main Burner Gas valve opens Main burner comes on Remember there is no pilot of any kind with the White Rodgers system! Measure for @ 105 volts DC to verify power to the gas valve solenoid 11 Main Burner Flame Performance Water is heated to thermostat setting Flame probe monitors flame presence Flame is rectified at @ 4 micro amps DC 12 Clean flame probe with steel wool if needed 4

Monitoring Safety Performance Blower motor over temp switch is monitoring venting temperatures Flammable Vapor sensor is constantly monitoring ambient air for flammable vapors ECO is monitoring water temp 13 Thermostat is Satisfied Thermostat is satisfied Suspends power to the ignition circuit Blower motor conducts post purge Water heater in stand by FV Sensor is constantly monitoring ambient air even when the burner is OFF! 14 Agenda Invensys to White Rodgers Control Appearance and connections Control Specifications Sequence of Operations Troubleshooting Flash Codes Removal, Replacement, Conversions 15 5

Lockout and Resets Timed lockout resets after 1 hour 3 auto resets max; then hard lockout Hard lockout must cycle power to the control to reset (human intervention) Permanent lockout Flammable vapor sensor or control failure 7 of 15 errors caused by Internal Diagnostics failures 16 Diagnostic Code Map 15 error codes 11 of 15 are self diagnosing You will need to work on (3) Pressure Switch stuck closed (4) Pressure Switch stuck open (6) Max Ignition Attempts (10) Unsupervised Flame 17 Error 1 Open Ground 18 6

Error 2 Polarity Reversed 19 Error 3 Pressure Switch will not Open (normally open switch) Verify continuity of pressure switch. If continuity present, then replace switch. May also be caused by a jumpered switch 20 Error 4 Pressure Switch will not Close (inducer will close switch) 1. Verify plastic tubing to pressure switch 2. Recycle heater 3. If heater starts, t then the venting is the problem 4. If the heater goes back into error code, replace blower and pressure switch May be caused by a blocked or restricted vent; pinched rubber hose to the pressure switch or a disconnected pressure switch. 21 7

Error 5 Hot Surface Ignitor Circuit Error (Silicon Nitride Ignitor) Unplug water heater from wall. 22 Error 6 Max Ignition Attempts (3 strikes and your out) A broken or damaged hot surface ignitor will present it s own unique fault code. 23 Error 7 Gas Valve Circuit Problem No counter test is available. Self diagnostic test takes precedent. 24 8

Error 8 Gas Valve Internal Problem No counter test is available. Self diagnostic test takes precedent. 25 Error 9 Failed Self Diagnostic Check No counter test is available. Self diagnostic test takes precedent. 26 Error 10 Unsupervised Flame Recycle heater and observe combustion chamber for premature flame or flame once the thermostat is satisfied. 27 9

Error 11 ECO is tripped 28 Automatic High Temperature Cutoff Single-Use Type, 195 F (90 C) Error 12 Temp Adjustment buttons stuck closed No counter test is available. Self diagnostic test takes precedent. 29 Error 13 Water Temp Thermistor Problem No counter test is available. Self diagnostic test takes precedent. 30 10

Error 14 FV Sensor Wiring Problem 31 1. Check all FV sensor wiring harness connections; and the connections to the back of the sensor. 2. Cycle power to the water heater off for 10 seconds and then back on. 3. If no wiring problems are found, the Flammable Vapor Sensor must be checked. a. Disconnect the FV sensor Molex and measure the resistance of the sensor between the two black wires 1 and 2. If the resistance is less than 9k OHMS or greater than 45k OHMS, then replace the sensor. b. If the FV sensor is between 9K and 45K and the code will not clear, replace the INTELLI-VENT control. Error 15 FV Sensor Detected Flammable Vapors 1. Verify FV sensor is less than 45k Ohms between the two black wires #2 and #3 2. Replace sensor if greater than 45k Ohms 3. Apply reset code to valve 32 11