Environmental Analysis Using the ICS-3000 Ion Chromatography System



Similar documents
Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

What is Eluent Generation?

Determination of Calcium and Magnesium in Brine

Using the AS Automated Sampler in the Simultaneous, Sequential, and Concentrate Modes

for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC)

Dionex IonPac AS19-4µm

Optimize Your Process Operations by Improving Process Monitoring

columns IonPac CS18 Cation-Exchange Column

IC Food Packs. Complete packs for food analysis. Free with every IC Food Pack: MagIC Net software Ultrafiltration

A Complete Solution for Method Linearity in HPLC and UHPLC

Automation of Sample Preparation in Ion Chromatography

IC-MS and LC-MS Determination of Ionic Liquids, Counterions, and Impurities

The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

INTRODUCTION. The principles of which are to:

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Anion chromatography using on-line recycled eluents

Standard methods in water analysis

Thermo Scientific Dionex ICS-1100 Ion Chromatography System

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Ion Chromatography in Environmental Analysis. Peter E. Jackson

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Assay for Citrate and Phosphate in Pharmaceutical Formulations Using Ion Chromatography

Dionex ICS-1100 Ion Chromatography System

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Flow Injection Analysis

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Determination of Benzenesulfonic Acid Counterion in Amlodipine Besylate by Ion Chromatography

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

ORGANIC SAMPLE PREPARATION

Transforming a ChromLab Software 2-D Purification Template into an Automated Multidimensional (Multi-D) Purification Workflow An Instructional Guide

The Sievers 900 Series TOC Analyzers

Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers. Automation, sample preparation. Autosamplers for Ion Chromatography

Pesticide Analysis by Mass Spectrometry

Thermo Scientific ConFlo IV Universal Interface

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

Elemental Analyses by ICP-AES

Sensitive and Rapid Determination of Polycyclic Aromatic Hydrocarbons in Tap Water

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Introduction. The following definitions may help you better understand the components of the data report.

WATERS QUANTITATIVE ANALYSIS solutions

How To Test For Contamination In Large Volume Water

S olid Ph ase Extraction (SP E) Method:

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Therapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Determination of Anions and Cations Content in Romanian Drinking Waters by HPIC Method

Agilent 4338B Milliohm Meter

Measurement by Ion Selective Electrodes

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Technical Spotlight. The Use of Ion Chromatography in the Printed Circuit Board Industry

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

6 Reactions in Aqueous Solutions

Carbohydrate in Coffee: AOAC Method vs a New Fast Ion Chromatography Method

Agilent 4339B/4349B High Resistance Meters

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Phoenix Apollo Laboratory TOC Analyzers and Services Designed To Meet Your Needs

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Determination of Total Nitrogen and Phosphorus in Wastewaters by Alkaline Persulfate Digestion Followed by IC

Dissolved and precipitated oxalate

DEIONIZATION IN A "NUT SHELL"

[ Care and Use Manual ]

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Third Party Instrument Control with Chromeleon Chromatography Data System (CDS) Software

Amino Acid Analyzer L-8900

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

MILESTONE H E L P I N G C H E M I S T S

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

QUANTITATIVE AMINO ACID ANALYSIS. Aurélie Lolia Applications Manager, Biochrom Ltd

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

The Theory of HPLC. Gradient HPLC

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Ion Exchange Design Hand calculation. Brian Windsor (Purolite International Ltd)

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Polyatomic ions can form ionic compounds just as monatomic ions.

LACHAT METHOD NUMBER D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately g CN/L g CN/L. 09e

[ Care and Use Manual ]

Transcription:

Environmental Analysis Using the ICS- Ion Chromatography System Ion chromatography (IC) is well established as a routine method for the analysis of ionic analytes in environmental samples. IC has been incorporated into environmental regulatory methods, worldwide, for quantifying contaminants in drinking water, wastewater, surface and ground water, rain water, soil extracts, and other environmental sample matrixes. Official methods from organizations provide detailed instructions on the application of IC methods to determine the concentration of regulated ionic contaminants. Examples of such organizations include the U.S. Environmental Protection Agency (EPA), American Society for Testing and Materials (ASTM), International Standardization Organization (ISO), Deutsches Institut für Normung (DIN), Association Française de Normalisation (AFNOR), and Japanese Institute for Standards (JIS). The ICS- delivers a new level of performance for environmental IC analysis. Equipped with either single or dual eluent pumps, ultrastable detectors (conductivity, amperometry, UV-Vis, MS) and a versatile valving system allows the ICS- to execute even the most complex IC methods with ease, precision and accuracy. The ICS- can easily perform all the traditional IC methodologies using, for example, carbonate eluents. In addition, it can also perform the more advanced methodologies using Reagent-Free IC (RFIC ) systems. RFIC systems bring a new level of precision and accuracy, as well as outstanding ease of operation, to IC analysis. When configured in the dual IC mode, the ICS- can easily deliver simultaneous anion and cation analyses, simultaneous multi method analyses, as well as two-dimensional (-D) methods that significantly enhance analysis sensitivity and selectivity. Furthermore, the ICS- is the ideal RFIC system to couple with mass spectrometry (MS) detection, to deliver the ultimate in sensitivity and selectivity for ion analysis. Passion. Power. Productivity.

IC Analysis Examples The following figures illustrate the performance of the ICS- for a broad range of environmental analytical applications. Figure shows the use of the ICS- RFIC system with hydroxide eluent generation and IonPac columns for the accurate and precise determination of common anions in environmental water samples. This combination has approval for drinking water and interim approval for wastewater compliance monitoring, using U.S. EPA Method.(A) and.(a). Figure shows the use of the ICS- RFIC system mode with the hydroxide-selective IonPac AG9 and AS9 ion-exchange columns, for the accurate and precise determination of common anions and oxyhalides, such as bromate, chlorite, and chlorate, in environmental water samples. This combination is approved for compliance monitoring using U.S EPA Method. (A and B) and. (A and B). Using this combination, bromate can be determined in municipal drinking water and bottled drinking water, with a detection limit (DL) of. µg/l (ppb). The high sensitivity performance of this method is more than adequate to do compliance monitoring of bromate in ozonated drinking water, where the maximum contaminant limit (MCL) is µg/l. Figure shows the use of the ICS- with a large loop injection (5 µl) for the determination of subppb level bromate in drinking water. The high capacity of the AS9 column, combined with the good separation of bromate from chloride, and the superior stability of the ICS- pump and conductivity detector, ensures excellent lowlevel bromate analysis, even when analyzing high TDS drinking water samples. 9 5 6 8 6 8 Figure. Determination of inorganic anions in drinking water..5.5 5 5 5 5 6 Column: IonPac AG8, AS8, mm Eluent: mm KOH for 7 minutes mm KOH for minutes Temperature: C Flow Rate:. ml/min Inj. Volume: 5 µl Detection: Suppressed conductivity, ASRS ULTRA II, mm recycled water mode Peaks:. Fluoride. mg/l. Chloride 75. Carbonate. Sulfate 5. Nitrate. 6. Phosphate.5 Figure. Determination of oxyhalides and bromide at trace-level concentrations in drinking water...5 5 5 Figure. Determination of bromate at concentrations below ppb in drinking water. Column: IonPac AG9, AS9, mm Eluent: 5 mm KOH in 5 minutes Temperature: C Flow Rate:. ml/min Inj. Volume: µl Detection: Suppressed conductivity, ASRS ULTRA II, mm recycled water mode Peaks:. Chlorite.5 µg/l. Bromate.98. Nitrite. Chlorate 55.5 5. Bromide.5 8 Column: IonPac AG9, AS9, mm Eluent: 5 mm KOH in 5 minutes Temperature: C Flow Rate:. ml/min Inj. Volume: 5 µl Detection: Suppressed conductivity, ASRS ULTRA II, mm recycled water mode Peaks:. Chlorite 6.5 µg/l. Bromate.68. Chlorate 57.. Bromide.5 9

Figures a and 5 show the use of the ICS- dual IC system to deliver greater sensitivity and selectivity for selected ion analysis (e.g., bromate) using -D IC. Figure a is a schematic diagram showing how the ICS- is configured in a -D mode for analysis of low-level bromate in environmental water samples. Two distinct separation channels or columns are set up in the DC Detector Chromatography module of the ICS- and used to automate this -D IC application. In this case, the first IC channel is used to separate bromate from other potentially interfering ions (e.g., chloride), using a high capacity -mm AS9 column, and to transfer it to a concentrator column. The concentrator column contents are then transferred to a lower capacity -mm AS9 column for independent separation and detection in the second IC channel. This mode of operation is best accomplished using RFIC hydroxide selective, high-capacity column chemistry to: Enhance sensitivity, since the large, 5 µl sample is ultimately chromatographed using a -mm column. Enhance selectivity, since the selected ion (e.g., bromate) is chromatographed a second time with fewer matrix ions, which significantly improves peak shape and minimizes potential interferences. The suppressed hydroxide eluent is water, which provides an ideal medium for trapping, focusing, and concentrating the ions of interest eluted from the first dimension (-D) separation onto the concentrator column in the second dimension. For complex applications (Figure a), the ICS- delivers a solution: the AM Automation Manager, shown in Figure b. Typically, adding extra valves, plumbing and determining void volumes is cumbersome and tedious. With the AM, complex plumbing configurations, such as that used in the -D preconcentration for bromate (Figure a) are easier to implement. Preconcentration is controlled independently with Injection Valve Large Loop Suppressor mm Column Pump EG Load Inject Autosampler Injection Valve Cell Injection Valve Concentrator Column Pump Transfer to -D Load Concentrator mm Column EG Cell Suppressor Figure a. Configuration of the ICS- for -D IC determination of tracelevel bromate and perchlorate in environmental water samples (see Figures 5c, 5d, and 9). Figure b. The AM Automation Manager mounts inside the Detector Chromatography compartment (DC) and integrates up to two high-pressure valves, two solenoid valves, and a postcolumn heater. The entire AM mounts on a moveable slide for easy configuration for any application. All components are completely controlled through Chromeleon. in the AM while injection is controlled by in Injection Valve within the DC. This allows the entire process sample preparation, injection, separation, and analysis to occur in the temperaturecontrolled DC compartment. The result is greater reproducibility for complex applications. By placing the AM within the DC, samples are preequilibrated for the precise temperature of the separation. This provides greater consistency from run to run. Control all valves with Chromeleon software, simplifying programming and eliminating the use of TTL contact closures. Each valve is individually named so that it is easy to synchronize fluidic pathways and to simplify troubleshooting. Use the AM as a separate injection system. With a dual-heated zone, you can run applications at different temperatures. For example, channel one can have the injection valve and column in the lower chamber at one temperature, while channel two can have the injection valve and column in the upper chamber at a different temperature. Applications with typical loop injection or preconcentra-

tion and matrix elimination can be accomplished on any channel. Figure 5a shows the result of a -D separation on a -mm column of a 5-µL injected sample containing 5 µg/l bromate in a low salt matrix. Here the bromate peak is small but quantifiable. Figure 5b shows the result of a -D separation from a 5-µL injected sample also containing 5 µg/l bromate in a high salt matrix. Here the bromate peak is not distinguishable from baseline variation. Figure 5c shows the result of a -D separation of bromate from the low salt matrix that was trapped on a concentrator column and transferred to -D column (-mm) for further separation and detection. The bromate peak from the secondary column is larger than from the -D column. Figure 5d shows the result of a -D separation of bromate from the high salt matrix sample that was trapped on a concentrator column and transferred to a second column (-mm) for further separation and detection. The bromate peak from the second column is now clearly distinguishable as compared to the -D column results. Furthermore, this bromate peak is the same size as that obtained from the low salt sample. Thus, this mode of operation yields greater sensitivity and minimizes interference from the high salt matrix. This mode of operation is sometimes called heart-cutting. This technique is used to isolate unresolved solutes from one separation and place the mixture on another column that resolves the solutes. In this example, the technique is used as a form of enrichment process where the solute of interest, e.g., bromate, is nondetectable due to the presence of large amounts of chloride......... (A) 5 ppb BrO in Low Salt Water (B) 5 ppb BrO Sample Spiked with 5 ppm each Cl and SO (C) 5 ppb BrO in Low Salt Matrix (D) 5 ppb BrO Sample Spiked with 5 ppm each Cl and SO 5 5 5 5 Column: AG9, AS9, mm Eluent Source: EGC KOH Flow Rate:. ml/min Suppressor: ASRS ULTRA II, mm Current: ma Loop: 5 ml Oven: C Gradient: Time mm 5 5 5. 5 Peaks A B. Bromate.5 mg/l. Chloride. 5 mg/l. Sulfate.5 5 Primary Secondary Column: AG9, AS9, mm AG9, AS9, mm Eluent Source: EGC KOH EGC KOH Flow Rate:. ml/min.5 ml/min Suppressor: ASRS ULTRA II, mm ASRS ULTRA II, mm Current: ma 9 ma Loop: 5 ml Concentrator: TAC-ULP Oven: C C Gradient: Time mm mm 9.5 5 5 5..5 5 5 5 Peaks: C D. Bromate.5 mg/l.5 mg/l. Chloride. 5. Sulfate.5 5 - Figure 5. The ICS- dual IC system delivers greater sensitivity and selectivity for selected ion analysis (e.g., bromate).

Figure 6a shows the use of the ICS- in the RFIC mode with the CG6 and CS6 cation-exchange columns, for accurate and precise determination of common cations and ammonium using ASTM Method D699-. This method has been proposed by the U.S. EPA for compliance monitoring of drinking water and wastewater..5 A 5 6 Column: IonPac CG6, CS6, 5 mm Eluent: 6 mm MSA Eluent Source: EGC KOH Temperature: C Flow Rate:.5 ml/min Inj. Volume: µl Detection: Suppressed conductivity, CSRS, VLTRA II mm recycled water mode Peaks:. Lithium. mg/l. Sodium 9. Ammonium.. Potassium. 5. Magnesium.9 6. Calcium.76 Figure 6b shows how the CS6 column gives sufficient resolution of sodium and ammonium to allow quantification of ammonium at the µg/l level, even in the presence of high mg/l levels of sodium. Figure 7 shows the use of the ICS- dual RFIC IC system to deliver simultaneous anion and cation analyses of the same sample, using only one autosampler. In this case, the autosampler loads the injection loop of each IC channel with the same sample, so that anions and cations can be analyzed simultaneously, without crosscontamination of eluents. By providing simultaneous analysis of anions and cations, the dual ICS- increases IC sample throughput without taking more benchspace than a single system. The Chromeleon data system manages detection and quantitation and delivers a report which coordinates the anion and cation results for each sample in a convenient, easy to read format. Note that this simultaneous mode of dual channel IC operation can also be used for simultaneous small loop and large loop anion or cation analysis. This mode of operation is especially beneficial when analyzing samples of unknown ionic concentration levels, where some are suspected to be of low concentration and others of high concentration. For example, one IC channel with a µl loop can be calibrated from ppb to ppb ( ppm), while the other IC channel with a µl loop can be calibrated from ppm to ppm.. B 5 6. 5 5 5 Figure 6. Determination of common alkali and alkaline earth cations and ammonium using an RFIC system. Series Analysis ICS- Simultaneous Analysis ANIONS ANIONS CATIONS CATIONS 8 Injections Hours Chloride Sulfate Bromate Fluoride Nitrite Bromide Chlorite Chlorate Nitrate Carbonate 5 5 5 Lithium Sodium Ammonium Potassium Magnesium Calcium 5 5 6 Phosphate 6 Injections Hours 7 minute gradient equilibration Figure 7. The AS Autosampler with simultaneous analyses provides nearly twice the throughput compared to traditional IC systems. 7 69 5

Using simultaneous dual channel IC operation samples can be accurately analyzed over four orders of magnitude, i.e., ppb to ppm, without any advanced estimate of analyte concentrations. This virtually eliminates sample dilution and time consuming sample reruns. Figure 8 shows the use of the ICS- system for the determination of sub-ppb levels of perchlorate in drinking water by EPA Method.. Typical levels of TDS in the drinking water range from to 7 ppm each for chloride and sulfate, as well as residual ppm levels of carbonate. These anions can interfere with the accurate determination of ppb levels of perchlorate. Figure 8 chromatograms are shown with and without the use of the new Dionex Carbonate Removal Device (CRD). The CRD removes residual amounts of carbonate from the sample and facilitates enhanced detection and quantitation of sub-ppb perchlorate in drinking water samples. Benefits of using the ICS- for perchorate analysis by Method. include the following: Using this instrument/column combination, and sodium hydroxide eluent generation,.5 µg/l detection limits for perchlorate are achieved, even with a common anion concentration of up to mg/l, each, of chloride, bicarbonate, and sulfate. EPA Method. documents this method and details the use of a primary column set (AG6 and AS6) and a confirmatory column set (AG and AS) to provide the Concentration:.5 mm 65. A: With CRD 5 5 5 5 Figure 8. Chromatogram showing.5 ppb (µg/l) perchlorate in Sunnyvale drinking water. opportunity to confirm that the peak quantified is actually perchlorate. The ICS dual RFIC IC system allows the simultaneous determination of perchlorate, using both the primary and confirmatory columns, simultaneously from only one injection and one autosampler. Sequential analysis increases flexibility by using a diverter valve with the AS autosampler to deliver any sample to any channel, one at a time on a first come, first served basis. With this capability, you can introduce the same sample or two different samples to two independent eluent streams.. B: Without CRD Column: IonPac AG, AS mm Eluent:.5 mm NaOH min 65 mm.8 mm, mm 8.5 min Eluent Source: EGC NaOH with CR-ATC Temperature: 5 C Flow Rate:.5 ml/min Inj. Volume: ml Rinse Volume: ml ( mm NaOH) Concentration: IonPac Cryptand C ( 5 mm) Detection: ASRS ULTRA II, mm AutoSuppression external water mode Peaks:. Perchlorate.5 µg/l (ppb). Unknown 685 Whether you choose simultaneous or sequential injection, one autosampler is shared between two independent systems. Combine detectors for conductivity, electrochemical, or UV detection on the same sample or different samples. Virtually any analysis combination is possible anions/cations, anions/trace metals, etc. 6

As shown previously in Figure, the ICS- can be configured to perform -D IC for enhanced detection sensitivity of low-level environmental contaminants such as perchlorate. Figure 9 demonstrates the effectiveness of the ICS- setup in the -D mode with an IonPac AS -mm column in the first dimension and a -mm AS column in the second dimension. Chromatogram 9A shows the analysis of.5 µg/l perchlorate in a simulated high TDS matrix of ppm each of chloride, carbonate, and sulfate. Figure 9B shows the same analysis in reagent water. The perchlorate peak areas in these two analyses are virtually identical. Further, interference and tailing from the other high-concentration matrix anions is significantly reduced. This demonstrates the power of -D IC on the ICS- for detecting and quantifying sub-ppb levels of perchlorate in challenging matrices.. A:.5 ppb ClO spiked with matrix ions ( ppm Cl, HCO, SO ).5 5 5 5. B:.5 ppb ClO in Reagent Water.5 5 5 5 Primary Secondary IonPac Column: AG, AS mm AG, AS mm Flow Rate:. ml/min.5 ml/min Concentration: 5 mm KOH 6 mm KOH Suppressor: ASRS ULTRA II mm ASRS ULTRA II mm Current: 87 ma 8 ma Loop: ml Concentrator: TAC-ULP Temperature: C Matrix A B Chloride ppm Bicarbonate Sulfate Peaks:. Perchlorate:.5 µg/l (ppb) Figure 9. Two-dimensional perchlorate analysis with the IonPac AS column. 69 What the ICS- Means to You The ICS- brings a new level of precision, accuracy, versatility, and ease of operation to environmental ion analysis. Dual pump and dual IC configurations add new capability to IC methodology. Heart-cutting methods, simultaneous method analysis and postcolumn reagent addition methods are easily and reliably performed using the new ICS-. The robust ICS- delivers a whole new level of productivity, power, and sensitivity to the environmental analysis laboratory. 7

Passion. Power. Productivity. Reagent-Free and RFIC are trademarks and ASRS, Chromeleon, CSRS, and IonPac are registered trademarks of Dionex Corporation. Dionex Corporation 8 Titan Way P.O. Box 6 Sunnyvale, CA 988-6 (8) 77-7 North America Sunnyvale, CA (8) 77-85 Westmont, IL (6) 789-66 Houston, TX (8) 87-565 Atlanta, GA (77) -8 Marlton, NJ (856) 596-6 Canada (95) 8-965 www.dionex.com Europe Austria () 66 5 5 Belgium () -5 9 Denmark 6 6 9 9 France 9 Germany 66-99- Italy (6) 66 5 5 5 The Netherlands (6) Switzerland (6) 5 99 66 United Kingdom (76) 697 Asia Pacific Australia (6) 9 5 China (85) 8 8 India 9--8755 Japan (6) 6885- Korea () 65 58 LPN 78 8M /6 6 Dionex Corporation